ASALAIR CARBO FUME CUPBOARD

Transcript

ASALAIR CARBO FUME CUPBOARD
ASAL S.R.L. - APPARECCHI SCIENTIFICI ATTREZZATURE LABORATORI
Quality System comply with requirements of UNI EN ISO 9001:2008.
Certificate TÜV Italia n° 50 100 3290 – Rev. 04
ASALAIR CARBO FUME CUPBOARD
1200 F.A. – 1200/R F.A.
1200/F.A.: CODE 29940006
1200/F.B.: CODE 29940007
1200 HEPA: CODE 29940064
1500 F.A. – 1500/R F.A.
1500/F.A.: CODE 29940036
1500/F.B.: CODE 29940037
1500 HEPA: CODE 29940058
1800 F.A. – 1800/R F.A.
1800/F.A.: CODE 29940034
1800/F.B.: CODE 29940035
1800 HEPA: CODE 29940065
TIPO / F.A.: ACTIVATED CARBON FILTER FOR GENERIC SUBSTANCES
TIPO / F.B.: IMPREGNATED CARBON FILTER FOR SPECIAL SUBSTANCES
TIPO / HEPA: HEPA FILTER (HIGH EFFICIENCY PARTICULATE AIR)
ASAL s.r.l. Via Firenze n° 37 - 20063 Cernusco s/N (MI) - Italy
Tel. +39 02/92.10.23.34 - Fax +39 02/92.10.48.66
Http://www.asal.it – e-mail: [email protected]
We reserve for ourselves right to introduce without notice all the modifications necessary for the product improvement
Ed. 12/15
Page 1 of 15
ASAL s.r.l. Via Firenze n° 37 - 20063 Cernusco s/N (MI) - Italy
Tel. +39 02/92.10.23.34 - Fax +39 02/92.10.48.66
Http://www.asal.it – e-mail: [email protected]
We reserve for ourselves right to introduce without notice all the modifications necessary for the product improvement
Ed. 12/15
Page 2 of 15
Model 1200/R F.A. – 1500/R F.A. – 1800/R F.A.
Equipped as standard with air conveyor Ø 150 mm. (Ø 200 mm for 1800/R F.A.) with anti-wind air
grating, for the exhaust outside of filtered air, that the customer is REQUIRED to install.
APPROVALS



2006/95/CE (BT low tension)
CEI EN 61010-1:2001 and UNI EN 14175-1-2-3:2003 certificate n° Z1 11 12 36567 030
directive EMC (Electro-magnetic directive 2004/108/CE) EN 61326-1:2006, certificate n° Z2
11 10 36567 029
This equipment has been designed, built and tested following the European Directive 2006/95/CE (BT low
tension), CEI EN 61010-1:2001 and UNI EN 14175-1-2-3:2003 fume cupboards certificate n° Z1 11 12
36567 030 and directives EMC (Electro-magnetic directive 2004/108/CE) EN 61326-1:2006, certificate n° Z2
11 10 36567 029 with omologation by TUV SUD.
ASAL s.r.l. Via Firenze n° 37 - 20063 Cernusco s/N (MI) - Italy
Tel. +39 02/92.10.23.34 - Fax +39 02/92.10.48.66
Http://www.asal.it – e-mail: [email protected]
We reserve for ourselves right to introduce without notice all the modifications necessary for the product improvement
Ed. 12/15
Page 3 of 15
Model 1200 F.A. – 1500 F.A. – 1800 F.A.
This model does not require any air conveyor
APPROVALS



2006/95/CE (BT low tension)
CEI EN 61010-1:2001 certificate n° Z1 11 12 36567 027
directive EMC (Electro-magnetic directive 2004/108/CE) EN 61326-1:2006, certificate n° Z2
11 10 36567 029
This equipment has been designed, built and tested following the European Directive 2006/95/CE (BT low
tension), CEI EN 61010-1:2001 n° Z1 11 12 36567 027 and directives EMC (Electro-magnetic directive
2004/108/CE) EN 61326-1:2006, certificate n° Z2 11 10 36567 029 with omologation by TUV SUD.
ASAL s.r.l. Via Firenze n° 37 - 20063 Cernusco s/N (MI) - Italy
Tel. +39 02/92.10.23.34 - Fax +39 02/92.10.48.66
Http://www.asal.it – e-mail: [email protected]
We reserve for ourselves right to introduce without notice all the modifications necessary for the product improvement
Ed. 12/15
Page 4 of 15
DESCRIPTION
Asalair Carbo fume cupboard model 1200-1500-1800 F.A. is a suction hood with molecular filtration,
equipped with activated carbon filter.
It assures an excellent protection both of the operator and the environment, it holds in its activated carbon
filter all harmful molecules to respiration and environment.
It’s not suitable like protection for the products manipulated into it from the external contamination.
It can be used in all cases it is not essential to protect the product from the air present in the laboratory (eg
opening of biological samples for analysis, manipulation of organic and inorganic substances that produce
toxic vapours or smelly, or as protection for centrifugal apparatus risk of aerosols, etc.).
The work area is characterized by a double suction system, allowing the extraction of heavy and light
vapours through a special rear bottom, directing them to the adsorbent filters (the impulse is also achieved
thanks to the front airflow).
Raising the front panel also automatically varies the speed of air suction, allowing you to maintain the
security barrier front.
The activated carbon filter for generic substances (TYPE A) absorbs most of the aliphatic and aromatic
hydrocarbons, solvents, organic vapors, ketones, alcohols, organic acids, esters, halogens, unpleasant
odors, sulfur compounds. Other substances such as ammonia, formaldehyde and derivatives, acid gases,
iodine, mercury, order the hood with carbon filter impregnated for one of these substances (TYPE B).
For the choice of filter order, see ACTIVATED CARBON ADSORPTION CAPACITY TABLE on next pages.
We remind you that in choosing the type of carbon filter for use in hoods, Asal srl gives general indications
resulting from information received from the customer can choose 5 types of carbon filters:
- For organic and inorganic vapors (alcohol, solvents, dyes, etc.)
- For acid gases
- For mercury
- For ammonia
- For iodine
- For aldehyde, formaldehyde
Asal srl disclaims all liability for any accidents due to chemical reactions, explosions or poisoning that may be
caused by incorrect choice of the type of carbon or from improper use of the hood.
Casing realised in powdered painted steel acids resistant, RAL 9010.
It can be installed over any bench. Its working surface consists of a removable tray in stainless steel Aisi
316L 2B glazed which allows the hood location also over tanks or sinks.
NEW
Possibility to order the work benchtop in WHITE POLYPROPYLENE OR MONOLITHIC STONEWARE,
with excellent resistance to acids, alkalis, bases and high temperatures. On request with tank and
drain.
Contact us to choose the filter and the work benchtop most suitable to your needs.
The model certified in accordance with UNI EN 14175-1-2-3:2003 model 1200/R F.A. – 1500/R F.A. 1800/R F.A. is equipped as standard with air conveyor Ø 150 mm. (Ø 200 mm for 1800/R F.A.) with antiwind air grating, for the exhaust outside of filtered air, that the customer is REQUIRED to install.
The model certified in accordance with only EN 61010-1:2001 model 1200 F.A. – 1500 F.A. – 1800 F.A.
does not require any air conveyor.
ASAL s.r.l. Via Firenze n° 37 - 20063 Cernusco s/N (MI) - Italy
Tel. +39 02/92.10.23.34 - Fax +39 02/92.10.48.66
Http://www.asal.it – e-mail: [email protected]
We reserve for ourselves right to introduce without notice all the modifications necessary for the product improvement
Ed. 12/15
Page 5 of 15
FEATURES


1200 F.A.-1500 F.A. Activated carbon filters: 10+10 Kg.
1800 F.A. Activated carbon filters: 10+10+10 Kg.

Prefilters in synthetic material class G3 (82% efficiency) in accord. with EN 779









Casing realised in powdered painted steel acids resistant, RAL 9010.
Work surface is a removable tray in stainless steel Aisi 316L 2B glazed.
Front sash and lateral panels in Plexiglas.
Front sash motor switch
Front opening from min. 250 mm. to max 650 mm.
Aspired air regulation with electric contact in function of the frontal opening: it allows maintaining
constant the protection frontal barrier.
Polycarbonate membrane control panel with microprocessor.
Outlet service, outside the work room, programmable, with timer hours visualisation max 99 hours,
with overload fuse
Filter and outlet service working hours visualisation, with digital hours counter, max 9999 hours.
Warning signal (flashing display) in case of no tension during the use of the outlet service.
N°2 (N°3 x 1800 F.A.) low background noise electric fans that meet the requirements of the directives
EN 60335-1, EN 50178, EN 60950, approvals by VDE, CE, UL. Possibility to regulate airflow.
N°1 fan for frontal airflow parallel to the work surface to push towards the back wall of heavy vapours.
Two speed fans switch. Double ejection air speed control in function of the front opening.
Emergency button speed aspiration.


1200 F.A. lighting: 1 x 30 W - 800 Lux, outside the work area.
1500 F.A.-1800 F.A. lighting: 1 x 36 W - 800 Lux, outside the work area.

On the right side of the hood, attack with hose union to be grafted, for execution of the carbon filter
saturation test.
Noise ≤ 60 Db.
Possibility to insert another ejection filter (activated carbon or hepa filter).







ASAL s.r.l. Via Firenze n° 37 - 20063 Cernusco s/N (MI) - Italy
Tel. +39 02/92.10.23.34 - Fax +39 02/92.10.48.66
Http://www.asal.it – e-mail: [email protected]
We reserve for ourselves right to introduce without notice all the modifications necessary for the product improvement
Ed. 12/15
Page 6 of 15
TECHNICAL SPECIFICATIONS
F.A.
Work area
dimension
WxDxH mm.
Tank capacity
litres
Overall
dimension
WxDxH mm
Overall
dimension
with air
conveyor
WxDxH mm
Filtered air
volume
m³ / h
Air average
speed m/s
Weight Kg.
1200
1150x600x
770
8
1285x780x
1500
1285x780x
1670
820
0.5
200
1500
1450x600x
770
10
1585x780x
1500
1585x780x
1670
900
0.5
250
1800
1750x600x
770
12
1885x780x
1500
1885x780x
1670
1500
0.5
300
ELECTRICAL SPECIFICATIONS
F.A.
Power supply
Electrical Input
Overload fuses
Outlet overload
fuse
Connection outlet
1200
230 V - 50 Hz.
280 W + 440 W
2 x 5 AF (5 x 20)
mm.
1 x 2 AF (5 x 20)
mm.
10 A
1500
230 V - 50 Hz.
350 W + 440 W
2 x 5 AF (5 x 20)
mm.
1 x 2 AF (5 x 20)
mm.
10 A
1800
230 V - 50 Hz.
420 W + 440 W
2 x 5 AF (5 x 20)
mm.
1 x 2 AF (5 x 20)
mm.
10 A
SAFETY: all the electrical components, switches and wirings are kept in the control panel, separated
from the airflow in order to avoid inconveniences when inflammable materials are handled inside the
hood.
ASAL s.r.l. Via Firenze n° 37 - 20063 Cernusco s/N (MI) - Italy
Tel. +39 02/92.10.23.34 - Fax +39 02/92.10.48.66
Http://www.asal.it – e-mail: [email protected]
We reserve for ourselves right to introduce without notice all the modifications necessary for the product improvement
Ed. 12/15
Page 7 of 15
CONTROL PANEL
2
9
6
1
5
7
8
11
FIG. 1
10
1
2
3
4
5
6
7
8
9
10
11
3
4
outlet control switch
emergency control maximum fan speed
lighting switch
low fan speed
fan switch
maximum speed fan
filter-outlet service time display switching
time display
filter working hours visualization, max 9999 hours.
outlet service timer hours visualization, max 99 hours.
outlet service working hours visualization, max 9999 hours.
1
2
3
4
Ventilatore / Motor fan
Staffa / Block stirrup
Filtro a carboni attivi / Activated carbon filter
Prefiltro / Prefilter
1
2
3
4
ASAL s.r.l. Via Firenze n° 37 - 20063 Cernusco s/N (MI) - Italy
Tel. +39 02/92.10.23.34 - Fax +39 02/92.10.48.66
Http://www.asal.it – e-mail: [email protected]
We reserve for ourselves right to introduce without notice all the modifications necessary for the product improvement
Ed. 12/15
Page 8 of 15
ACTIVATED CARBON ADSORPTION CAPACITY TABLE
1) Substances with high adsorption capacity by activated carbon (20-50%)
Acetate methylcellosolve
Acetophenone
Acetic anhydride
Acrylic acid
Acrylonitrile
Adhesives
Aldehyde atrica
Amilacetato
Amyl Alcohol
Amyl acetate
Amyl ether
Aniline
Antiseptics
Argon
Aromas of food
Asphalt fumes
Benzaldehyde
Benzene
Benzyl alcohol
Benzol
Body odors
Bromoform
Bromine
Butanol
Butylcellosolve
Butylacetate
Butylalcohol
Butylchloride
Butylether
Butyricacid
Camphor
Capril acid
Caproaldehyde
Carbolic acid
Carbon disulfide
Carbon tetrachloride
Cellosolve
Cellosolve acetate
Charter deteriorated
Cyclohexane
Cyclohexanol
Cyclohexanone
Cyclohexene
Chlorobenzene
Chlorobutadiene
Chloroform
Cigarette smoke
Cloronitropropane
Chloropicrin
Combustion odors
Cooking smells
Creosol o / m / p
Crotonaldehyde
Dean
Detergents
Dibromoethane
Dichlorobenzene
Dichlorobenzol
Dichlorodifluoromethane
Dichloroethane
Dichloroethylene
Dichloromethane
Dichloromonofluoromethane
Dichloronitroethane
Dichloropropane
Dichlorotetrafluoroethane
Diesel fumes
Diethylketone
Dimethylaniline
Dioxane
Dipropilketone
Ether dichlorethyl
Ethylacetate
Ethylalcohol
Ethylacrylate
Ethylbenzene
Ethylibenzol
Ethylene
Ethylformiate
Ethylsilicate
Ethylsulfide
Ethylene dichloride
Fertilizers
Freon 11
Freon 12
Freon 114
Fruit
Furfural
Gasoline
Heptene
Heptane
Naphtha
Naphthalene
Nicotine
Nitrobenzene
Nitroethane
Nitroglycerine
Nitromethane
Nitropropane
Nitrotoluene
Nonane
Octane
Odor of putrefaction
Ozone
Paint fumes
Palmitic
Paradichlorobenzene
Pentanone
Perchloroethylene
Pesticides
Phenol
Pyridine
Propylacetate
Propylalcohol
Propylchloride
Propylether
Propylmercaptan
Propyonic acid
Putrescine
Quinoline
Iodoform
Isopropyl acetate
Isopropyl alcohol
Isopropyl ether
Kerosene
Lactic acid
Liquid fuels
Lysol
Lubrificants, greases, oils
Menthol
Mercaptans
Mesityloxide
Methylacetate
Methyl
Methylacrylate
Methylcellosolve
Methylchloroform
Methylcyclohexane
Methylcycloesanolo
Methylcyclohexanone
Methylethylketone (butanone)
Methylformate
Methylmethacrylate
Methylene chloride
Methyloxide
Monochlorobenzene
Monofluorine
Resins
Sewer odors
Smells liquor
Smells of hospitals
Smells of fish
Styrene
Styrene Monomer
Sulphide composites
Tar
Tetrabromoethane
Tetrachloroethane
Tetrachlorothylene
Thiophene
Toluene
Toluidine
Turpentine
Trichloroethane
Trichloroethylene
Urea
Uric acid
Valeraldeide
Valeric acids
Vinegar
Xylene
Xylolo
ASAL s.r.l. Via Firenze n° 37 - 20063 Cernusco s/N (MI) - Italy
Tel. +39 02/92.10.23.34 - Fax +39 02/92.10.48.66
Http://www.asal.it – e-mail: [email protected]
We reserve for ourselves right to introduce without notice all the modifications necessary for the product improvement
Ed. 12/15
Page 9 of 15
2) Substances with good adsorption capacity by activated carbon (10-25%)
Acetone
Acetic acid
Anidirde sulfur
Arsenic
Butadiene
Butiraldehyde
Carbon disulphite
Carbon disulphide
Chlorine
Dichlorodifluoromethane
Dichlorotetrafluoroethane
Diethylamine
Dimethyl
Dimethyl sulphate
Esilene
Ethanol
Ether
Ethyl
Ethylbromide
Ethylchloride
Ethylether
Ethylene glycol
Ethylmercaptan
Mercaptonezene
Methylalcohol - methanol
Methylbromide
Methylacetate
Methylchloride
Methylether
Methylformate
Methylmercaptan
Monofluorine
Fluorinetrichloromethane
Formic acid
Freon
Furan
Pentane
Phosgene
Propionic aldehyde
Pyridine
Pyrrole
Propionaldehyde
Hexane
Hydrocyanic acid
Hydrogen sulphid
Rubber
Iodidcric acid
Isopropanol
Smells of slaughter
Solvents
Lead
Vinyl chloride
3) Substances with little adsorption capacity by activated carbon (< 15%)
Use impregnated carbon:
Aldeyde e derivatives (5/15%)
Mercury (5/15%)
Acid gases (5/15%)
Acetaldehyde (aldehyde and
derivatives)
Acetonitrile (ammonia and
derivatives)
Acrolein (aldehyde and derivatives)
Amines (ammonia and derivatives)
Ammonia (ammonia and derivatives)
Arsine gas (acid gases)
Bromopropane (acid gases)
Butane gas (acid gases)
Butene (acid gases)
Carbon dioxide (acid gases)
Carbon monoxide (acid gases)
Ammonia (5/15%)
Iodine (5/15%)
Diethylamine (ammonia and derivatives)
Dimethylamine (ammonia and
derivatives)
Ethidium bromide (acid gases)
Ethylamine (ammonia and derivatives)
Ethylene oxide (acid gases)
Formaldehyde (formaldehyde and
derivatives)
Hydrobromic acid (acid gases)
Hydrochloric acid (acid gases)
Hydrofluoric acid (acid gases)
Hydrogen selenide (acid gases)
Hydrogen sulfide (acid gases)
Iodine (iodine)
Nitric acid (acid gases)
Nitrogen dioxide (acid gases)
Phosphine gas (acid gases)
Propane gas (acid gases)
Propene (acid gases)
Prophylbromide (acid gases)
Sulfide gas (acid gases)
Sulfuric acid (acid gases)
Sulphur dioxide (acid gases)
Valeric aldehyde (aldehyde and
derivatives)
4) Substances not adsorbed by activated carbon
Acetylene
Carbonic acid
Carbon monoxide
Ethane
Ethylene
Methane
Methylbuthylketone
Hydrogen
Sulfur trioxide
Sulphur dioxide
ASAL s.r.l. Via Firenze n° 37 - 20063 Cernusco s/N (MI) - Italy
Tel. +39 02/92.10.23.34 - Fax +39 02/92.10.48.66
Http://www.asal.it – e-mail: [email protected]
We reserve for ourselves right to introduce without notice all the modifications necessary for the product improvement
Ed. 12/15
Page 10 of 15
ACCESSORIES ON REQUEST

Air conveyor connector Ø 150 mm. (Ø 200 mm for 1800 F.A.) with anti-wind air grating. In the cupboard certified
UNI EN 14175, the air conveyor is supplied as standard.




3/8” Water cock
Mixer cock for hot and cold water with extractable shower
3/8” Air/vacuum cock
3/8” cocks, on the right or left side of working zone: Nitrogen / Oxygen / Argon / Inert gas / Formalin / Carbon
dioxide (max pressure 10 bar).


3/8” Gas cock (max pressure 2 bar).
External outlet service 3 positions (schuko and/or Italian)

Work benchtop in white polypropylene or in monolithic stoneware, with excellent resistance to acids, salts, alkalis,
bases and high temperature. On request with tank and discharged.
Stainless steel tanks with discharged:
(dim. WxDxH 240x135x150 mm. - Lt. 4,1)
(dim. WxDxH 300x330x200 mm. - Lt. 19)
(dim. WxDxH 500x300x200 mm. - Lt. 30)

ASAL s.r.l. Via Firenze n° 37 - 20063 Cernusco s/N (MI) - Italy
Tel. +39 02/92.10.23.34 - Fax +39 02/92.10.48.66
Http://www.asal.it – e-mail: [email protected]
We reserve for ourselves right to introduce without notice all the modifications necessary for the product improvement
Ed. 12/15
Page 11 of 15



Polypropylene tank with discharged WxDxH: 250x100x150 mm. – Lt. 3.8
Stainless steel and polypropylene cover WxDxH 265x165 mm. for tanks
Other tanks and covers on request.

Hood‘s support without plan for hood equipped with 3/8” water cock, tank and discharged on the right side, dim.
WxDxH:

1200 F.A.: 1300x700x800 (830 with wheels) mm.

1500 F.A.: 1600x700x800 mm.

1800 F.A.: 1900x700x800 mm.

Drawers set with three draws and wheels WxDxH 410x500x570 mm. to fit under the support.
ONLY FOR 1200 F.A.:




Frontal closing panel in Plexiglas
Frontal closing panel in Plexiglas with prefilter and gloves
Hood‘s support with wood plan dim. WxDxH: 1400x800x830 (860 with wheels) mm
Four wheels kit for support.
OTHER FILTERS BY REQUEST:

Impregated carbon filter for special substances: Iodine, Mercury, Formaldehyde, Ammonia, Acid Gases.

Hepa absolute filter (High efficiency particulate air) tested M.P.P.S in accordance with C.E.N. 1822 global efficiency
99.995% class H14, to insert between work zone and active carbon filters.
ASAL s.r.l. Via Firenze n° 37 - 20063 Cernusco s/N (MI) - Italy
Tel. +39 02/92.10.23.34 - Fax +39 02/92.10.48.66
Http://www.asal.it – e-mail: [email protected]
We reserve for ourselves right to introduce without notice all the modifications necessary for the product improvement
Ed. 12/15
Page 12 of 15
ASAL s.r.l. Via Firenze n° 37 - 20063 Cernusco s/N (MI) - Italy
Tel. +39 02/92.10.23.34 - Fax +39 02/92.10.48.66
Http://www.asal.it – e-mail: [email protected]
We reserve for ourselves right to introduce without notice all the modifications necessary for the product improvement
Ed. 12/15
Page 13 of 15
ASAL s.r.l. Via Firenze n° 37 - 20063 Cernusco s/N (MI) - Italy
Tel. +39 02/92.10.23.34 - Fax +39 02/92.10.48.66
Http://www.asal.it – e-mail: [email protected]
We reserve for ourselves right to introduce without notice all the modifications necessary for the product improvement
Ed. 12/15
Page 14 of 15
ASAL s.r.l. Via Firenze n° 37 - 20063 Cernusco s/N (MI) - Italy
Tel. +39 02/92.10.23.34 - Fax +39 02/92.10.48.66
Http://www.asal.it – e-mail: [email protected]
We reserve for ourselves right to introduce without notice all the modifications necessary for the product improvement
Ed. 12/15
Page 15 of 15