Stampa
Transcript
Stampa
9184 sc HOCL Chlorine Hypochlorous Chlorine (HOCl) amperometric analyser Numero prodotto: LXV430.99.00001 EUR Prezzo: Contatti Disponibile Smart amperometric Hypochlorous Chlorine Sensor: 9184 sc Single channel industrial analyser. A membrane allows the selective diffusion of HOCl molecules to the sensor. All-inclusive system (except controller) preassembled on a panel. The membranes of the gold cathode and silver anode are pre-mounted on retaining caps to simplify and reduce maintenance time. Reagentless analysis of free chlorine, ion-selective membrane separates electrolyte from sample water The Hach 9184 sc sensor has a minimum detection limit of 5 ppb or 0.005 mg/L hypochlorous acid in the form of HOCl. All-inclusive, pre-assembled panel reduces installation expenses The 9184 sc sensor is particularly useful for drinking water distribution monitoring, chlorination applications, demineralizer systems, wastewater, or cooling water processes due to its 0 to 20 ppm measurement range. Plug & play with digital controller simplifies setup Measurements are made continuously by the sensor and reported to the controller Built-in flow regulation reduces need for additional accessories The 9184sc Analyzer is designed to be used with all Hach sc digital controllers. Set up is fast and easy, and the system is compatible with the full line of Hach digital sensors. Integral temperature sensor provides more accurate readings Specifiche tecniche Accuratezza: 2 % or ±10 ppb HOCl, whichever is greater at pH <8 Compensazione della temperatura: Automatic over sample temperature range Condizioni di stoccaggio: -20 °C - 60 °C Flusso: 0.25 L/h (200 to 250 mL/min) auto-regulated by flow thru cell Garanzia: 2 anni Grado di protezione : IP66 / NEMA 4X Ingresso del campione: 0.25 " outer diameter interferenze: No interference from chloramines. Chlorine dioxide and ozone interfere with measurement. Intervallo di manutenzione: 1 1.5 pH Cell: typical Intervallo di misura: Continuous Intervallo di pressione: 0.1 - 2 bar in flow cell (1.4-28 PSI) Intervallo di taratura: 2 mesi Intervallo pH: 4 - 8 acidification unit available for pH greater than 8 Limite di rilevamento: 0.005 mg/L HOCl lunghezza: 270 mm Metodo di taratura: Zero Calibration: electrically (automatic) or with de-chlorinated water Calibration: Comparison of lab method with process sample pH Calibration: Single- or two-point using standards or comparison of lab method with process sample Montaggio: Flat, vertical surface (panel, stand, etc.) Parametro: Hypochlorous Acid Only Chlorine Peso: 6.5 kg 14.3 lbs Principio di misura: Amperometric/Membrane (electrode, membrane, electrolyte) Standard deviation: 0.7 % Temperatura del campione: 2 - 45 °C (35.6-113 F) Temperatura di lavoro: 0 - 45 °C Tempo di risposta: 90 % in less than 90 seconds Umidità relativa: 0 - 90 % non-condensing Uscita del campione: 0.5 " inner diameter Contenuto della confezione Fully preassembled and panel mounted, includes membranes and electrolyte. Accessori richiesti • • Modulo display SC1000 con schermo touch (Item LXV402.99.00001) SC 200 Centralina digitale a 2 canali, EU cavo (Item LXV404.99.20551) Product details pdf footer