Stampa

Transcript

Stampa
9184 sc HOCL Chlorine Hypochlorous Chlorine (HOCl)
amperometric analyser
Numero
prodotto: LXV430.99.00001
EUR Prezzo: Contatti
Disponibile
Smart amperometric Hypochlorous Chlorine Sensor: 9184 sc
Single channel industrial analyser. A membrane allows the selective diffusion of HOCl molecules to the sensor. All-inclusive system (except
controller) preassembled on a panel.
The membranes of the gold cathode and silver anode are pre-mounted on retaining caps to simplify and reduce maintenance time.
Reagentless analysis of free chlorine, ion-selective membrane separates electrolyte from sample water
The Hach 9184 sc sensor has a minimum detection limit of 5 ppb or 0.005 mg/L hypochlorous acid in the form of HOCl.
All-inclusive, pre-assembled panel reduces installation expenses
The 9184 sc sensor is particularly useful for drinking water distribution monitoring, chlorination applications, demineralizer systems,
wastewater, or cooling water processes due to its 0 to 20 ppm measurement range.
Plug & play with digital controller simplifies setup
Measurements are made continuously by the sensor and reported to the controller
Built-in flow regulation reduces need for additional accessories
The 9184sc Analyzer is designed to be used with all Hach sc digital controllers. Set up is fast and easy, and the system is compatible with the
full line of Hach digital sensors.
Integral temperature sensor provides more accurate readings
Specifiche tecniche
Accuratezza:
2 % or ±10 ppb HOCl, whichever is
greater at pH <8
Compensazione della temperatura:
Automatic over sample temperature
range
Condizioni di stoccaggio:
-20 °C - 60 °C
Flusso:
0.25 L/h (200 to 250 mL/min)
auto-regulated by flow thru cell
Garanzia:
2 anni
Grado di protezione :
IP66 / NEMA 4X
Ingresso del campione:
0.25 " outer diameter
interferenze:
No interference from chloramines.
Chlorine dioxide and ozone interfere with
measurement.
Intervallo di manutenzione:
1 1.5 pH Cell: typical
Intervallo di misura:
Continuous
Intervallo di pressione:
0.1 - 2 bar in flow cell (1.4-28 PSI)
Intervallo di taratura:
2 mesi
Intervallo pH:
4 - 8 acidification unit available for pH
greater than 8
Limite di rilevamento:
0.005 mg/L HOCl
lunghezza:
270 mm
Metodo di taratura:
Zero Calibration: electrically (automatic) or with de-chlorinated water
Calibration: Comparison of lab method with
process sample
pH Calibration: Single- or two-point using standards
or comparison of lab method with
process sample
Montaggio:
Flat, vertical surface (panel, stand, etc.)
Parametro:
Hypochlorous Acid Only Chlorine
Peso:
6.5 kg 14.3 lbs
Principio di misura:
Amperometric/Membrane (electrode,
membrane, electrolyte)
Standard deviation:
0.7 %
Temperatura del campione:
2 - 45 °C (35.6-113 F)
Temperatura di lavoro:
0 - 45 °C
Tempo di risposta:
90 % in less than 90 seconds
Umidità relativa:
0 - 90 % non-condensing
Uscita del campione:
0.5 " inner diameter
Contenuto della confezione
Fully preassembled and panel mounted, includes membranes and electrolyte.
Accessori richiesti
•
•
Modulo display SC1000 con schermo touch (Item LXV402.99.00001)
SC 200 Centralina digitale a 2 canali, EU cavo (Item LXV404.99.20551)
Product details pdf footer