Osmoz / 44-certified housing Passivhaus
Transcript
Osmoz / 44-certified housing Passivhaus
Ca s o s tu d i o : O s m o z / 4 4 -ce r ti fi e d h o u s i n g P a s s i vh a u s S i to we b : h ttp ://www.co n s tr u cti o n 2 1 .o r g /i ta l i a / Osmoz / 44-certified housing Passivhaus PUBBLICATO DA POTIN | 0 1 LUGLIO 16 Tipo lo gia di pro getto : Nuo va co struzio ne Tipo di edificio : Co ndo minio di altezza inferio re a 50 m Anno di co struzio ne : 20 15 Zo na climatica : [Cfb] Marine Mild Winter, warm summer, no dry seaso n. Superficie utile calpestabile : 3 10 6 m 2 Co sto di co struzio ne/ristrutturazio ne : 4 340 0 0 0 € Numero delle unità funzio nali : 44 Appartamenti Co sti/m2 : 1 39 7 €/m 2 Co sti/Appartamenti : 9 8 6 36 €/Appartamenti rue du Gargo t , 440 0 0 Orvault, France // Descrizione T he willingness of the developer and the planner f or this island, f rom the competition phase is to position the project of high environmental quality and to include it in a PassivHaus certif ication. A passive residence is a virtually independent housing f or its heating needs: it can indeed be content with solar gains, the energy released by the occupants and household appliances and good insulation. Requirements "induced" by the lens 'passivhaus' are numerous: controlled cost, design details, collaborative work upstream with all project stakeholders, etc ... T hese objectives can sometimes get in 'conf lict' with urban requirements. Nevertheless, f acing south towards the Garettes Vallon in Orvault, in the Nantes area, the island site is positioned as a "balcony" opening on an open and green view, which is a North gazebo / South almost perf ect 'proposal f or a' passiv'haus'. T he architectural layout is divided into three separate buildings, and supplemented by three semi-underground houses built specif ically in the Park. T his f ragmentation of the buildings can of f er views sequenced f rom the street to the north, and soothes density 'supposed' of the project. T he project f ocuses theref ore a bioclimatic approach: Mixed c o nc ret e and t imber f rame st ruc t ure is f avo red giving t he building inert ia nec essary f o r any building t o st o re heat and redist ribut e it , as well as t o f avo r t he ac o ust ic s bet ween apart ment s, Do uble insulat io n f ro m t he o ut side and inside is pro vided wit h t reat ment o f t hermal bridges Lo o king f o r a c o mpac t and a c ro ss o f t he vo lume o f ho using (f o r nat ural vent ilat io n via o pening o n o ppo sing f ro nt s) Co mf o rt vent ilat io n rec o vering int ernal heat , Co rrido rs and balc o nies in wo o d and met al st ruc t ure det ac hed f ro m t he primary st ruc t ure o f f rames (t o avo id t hermal bridge) T he project emphasizes the concepts of ownership and residence by the will to get closer to individualized access f or maximum housing, and by private extensions f or each dwelling. Also, our project proposes to re-introduce concepts such as the f act to survey an alley, to borrow a gently sloping path to walk along a valley, crossing a bridge, to overhang another place, to go home. For each building, the main access is by the north f acade. T he external walkways detached f rom the main structure, of f er multiple views and promote lif e skills together. T hey generalize apartments crossing, double and triple orientation, without vis-à-vis and preserving the privacy of each. On the ground f loor, housing is accessible f rom the outside by a f ootpath of f the ground, "pontoons" introducing a gradual distancing between the public and the private. T he buildings, corridors and terraces, are wrapped in a skin natural douglas blades purged sapwood, with alternating rhythm. South, Vallon side railings also describe an alternating rhythm: light metal f loors and attic openwork chevrons. In the North, Railing corridors are lighter, perf orated metal, to pass a more homogeneous light. T his allows to reduce the linearity and break the monotony of plain f acades and cutting the f rame in rhythmic sequence. T his epidermis and provides a vibration chromatic f acades and suggested thickness. At t e ndibilit à de i dat i : Certificazio ne di terza parte // Stakeholders Progettista No me : Guinée*Po tin architectes Hervé Po tin architecte dplg Sito web : http://www.guineepo tin.fr T ipo lo gia co nt rat t uale : Lo tti separati Appro ccio de l pro prie t ario alla so st e nibilit à e ne rge t ica : certificatio n Passivhaus and NF HQE ho using. The pro ject o wner is co mmitted to a dual appro ach: De scrizio ne archit e t t o nica : The pro ject is in a green enviro nment and explo its the advantages o f the site respecting the architectural identity o f the future district. The pro ject emphasizes therefo re the enviro nmental appro ach and ado pt the principles o f bio climatic architecture, a site “nearly ideal” fo r this: - A mixed co ncrete and timber frame structure is favo ured giving the building inertia necessary fo r any building to sto re heat and redistribute it, as well as to favo ur the aco ustics between apartments, - A do uble insulatio n fro m the o utside and inside with high airtightness. - Research o f co mpactness and a cro ss o f the vo lume o f ho using. - Several Lo cal public bicycles will be pro vided inside buildings - The co rrido rs and balco nies in wo o d and metal structure detached fro m the primary structure o f the frames (to avo id thermal bridging) Therefo re, the pro ject meets the thermal perfo rmance in a PassivHaus certificatio n. // Energia Energy consumption Fabbiso gno di e ne rgia prim aria : 45,0 0 kWh EP/m 2 /an Fabbiso gno di e ne rgia prim aria de l m e de sim o e dif icio co st ruit o se co ndo gli st andard m inim i pre vist i dalla no rm at iva vige nt e : 45,0 0 kWh EP/m 2 /an Me t o do di calco lo : RT 20 12 CEEB : 0 kWh PE / € Performance dell'involucro T rasm it t anza : 0 ,8 0 W.m -2 .K-1 Indicat o re : I4 (I4) m 3 /H.m 2 n50 (Vo l/H) Q4 Indice di t e nut a all'aria de ll'invo lucro e dilizio : 0 ,11 // Fonti Rinnovabili e Impianti Systems Im piant o di riscaldam e nt o : Emissio ne - Radiato re elettrico Im piant o di pro duzio ne di acqua calda sanit aria : Po mpa di calo re So lare termico Im piant o di raf f re scam e nt o : Nessun sistema di raffrescamento Im piant o di ve nt ilazio ne : Scambiato re di calo re a do ppio flusso Sist e m i pe r lo sf rut t am e nt o di f o nt i di e ne rgia rinno vabili : Po mpa di calo re // Prestazioni ambientali // Prodotti aluminum joinery Pro dut t o re : Kline Co nt at t o : Menuisries Kline - 8 50 0 0 Les Herbiers Sit o we b: http://www.k-line.fr Cat e go ria de l pro do t t o : Opere di finitura / Elementi esterni - Po rte e Finestre De scrizio ne : Jo inery aluminum triple glazing Co m m e nt i: This is jo inery very high thermal perfo rmance, adapted fo r Passivhaus. These jo ineries also allo w perfect sealing o f facades. Framing, carpentry and wood siding Pro dut t o re : CMBS Co nt at t o : Z.a. du Creler, 56 19 0 Le Guerno Sit o we b: http://www.acieo .fr/ Cat e go ria de l pro do t t o : Opere strutturali / Tampo namento , Rivestimento , Tenuta De scrizio ne : The pro ject structure is mixed co ncrete shear walls fo r sails, and wo o d fo r devices co ats walls. The frame is wo o d. This ensures o ptimal enviro nmental perfo rmance, co ncrete ensuring the thermal inertia o f the pro ject, wo o d, bio -based materials with the interpo sitio n o f an efficient thermal insulatio n between framing members. Wo o d siding is o f several types: natural do uglas purged sapwo o d (3 natural class) to the attic and exterio r sheds, and Do uglas Treaty "bro wn" fo r co mmo n parts. Co m m e nt i: Wo o d describes the pro ject in its integratio n with the eco -neighbo rho o d, and identifies the building in the near landscape, o pen to the Vallo n and inhabitant 'territo ry. // Costi Co sto di co struzio ne/ristrutturazio ne : 4 340 0 0 0 € Construction and exploitation costs Co st o glo bale : 4 340 0 0 0 ,0 0 € Co st o glo bale /Appart am e nt i : 9 8 6 36 ,36 €/Appartamenti Co st o de l pro ge t t o : 318 8 25,0 0 € // Qualità della pianificazione urbana Am bie nt e urbano : densificatio n. This is the eco -neighbo rho o d o f the Vallo n des Garettes, no rth o f Nantes, Orvault, in full urban Supe rf icie t o t ale de ll\'are a di int e rve nt o : Num e ro di parche ggi : 6 18 1 m 2 8 8 semi buried lo ts, buried and aerial // Qualità ambientale dell'edificio Qualit à am bie nt ale de ll\'e dif icio : Bio diversità Cantiere (inclusa la gestio ne dei rifiuti) Acustica Efficienza energetica Energia da fo nti rinno vabili Integrazio ne ambientale Pro cessi di co struzio ne Pro do tti e materiali // Concorsi All acco mo datio ns (44) have been certified 'passiv'haus' by 'The Passive Ho use'. The pro ject is part o f the Vallo n des Eco quartier Garettes at Orvault.To us ho using are thro ugh, with have a do uble o r triple o rientatio n, and all have an o uter surface (balco nies, terraces o r gardens). The aesthetics o f the pro ject witho ut co mpro mise, invo lves an enviro nmental architecture is syno nymo us with architectural and landscape quality.