Istruzioni di montaggio

Transcript

Istruzioni di montaggio
MINIBRIQUE TONDA E QUADRA INCASSO
S.4530
S.4531
S.4540
S.4541
B
100mm
100mm
A
S.4535
S.4568
S.4545
S.4578
8mm
100mm
70mm
100mm
MINIBRIQUE TONDA E QUADRA INCASSO
Art. S.4531 - S.4535
per lampada alogena QT9 MAX 20W G4 12V
Art. S.4530 - S.4568
per lampada alogena QT9 MAX 20W G4 12V
Art. S.4541 - S.4545
per lampada alogena QT9 MAX 20W G4 12V
Art. S.4540 - S.4578
per lampada alogena QT9 MAX 20W G4 12V
(completo di cassaforma S.4612)
(cassaforma S.4612 non inclusa)
(completo di cassaforma S.4613)
(cassaforma S.4613 non inclusa)
Lampada alogena a bassa pressione
Alimentare l'apparecchio con un trasformatore di sicurezza 12V MIN. 20 VA conforme alle norme CEI 61347-1 e CEI 61347-2-2
CASSAFORMA S.4612
CASSAFORMA S.4613
70mm
10mm
70mm
10mm
Ø
98mm
Ø
86mm
98mm
x
98mm
86mm
x
86mm
CARATTERISTICHE TECNICHE
CLASSE III
IP 54
ISTRUZIONI DI MONTAGGIO
Aprire l'apparecchio, svitare la vite (A) e rimuovere la piastra (B) dalla sua sede.
Inserire i cavi unipolari di tipo <HAR> D. 6 ÷ 10 mm nel gommino passafilo ed effettuare il cablaggio elettrico
Rimontare la piastra (B) con la vite (A)
Fissare l'apparecchio alla cassaforma con le viti in dotazione
Inserire la lampada adatta
Richiudere l'apparecchio
NOTE: Per l'installazione ad incasso utilizzare le apposite cassaforme
Non superare la potenza indicata nei dati di targa
Togliere tensione prima di effettuare manutenzioni
L'apparecchio è idoneo al montaggio su superfici normalmente infiammabili
L' installazione deve essere eseguita da personale qualificato secondo
le norme di settore
Il rispetto di queste norme è molto importante per l'efficienza dell'apparecchio
e per la sicurezza delle persone, pertanto esse vanno conservate
ISTRMINIBTON REV.6 08/09
MINIBRIQUE ROUND & SQUARED RECESSED
S.4531
S.4541
B
100mm
100mm
A
S.4535
S.4545
8mm
100mm
70mm
100mm
MINIBRIQUE ROUND AND SQUARED RECESSED
Art. S.4531 - S.4535
for low voltage halogen lamp QT9 MAX 20W G4 12V
Art. S.4530 - S.4568
for low voltage halogen lamp QT9 MAX 20W G4 12V
Art. S.4541 - S.4545
for low voltage halogen lamp QT9 MAX 20W G4 12V
Art. S.4540 - S.4578
for low voltage halogen lamp QT9 MAX 20W G4 12V
(recess box S.4612 supplied)
(recess box S.4612 not supplied)
(recess box S.4613 supplied)
(recess box S.4613 not supplied)
Low pressure halogen lamp
Suplied the fitting with a safety transformer 12V MIN. 20 VA in compliance at the standards CEI 61347-1 e CEI 61347-2-2
RECESS BOX S.4612
RECESS BOX S.4613
70mm
10mm
Ø
98mm
70mm
10mm
Ø
86mm
98mm
x
98mm
86mm
x
86mm
TECHNICAL CHARACTERISTICS:
CLASS III
PROTECTION LEVEL : IP 54
ASSEMBLING INSTRUCTIONS:
Open the fitting, unscrew the (A) screw and remove the plate (B) from its position
Insert the single wires type <HAR> D. 6 ÷ 10 mm into the grommet and connect them to the terminal block
Re-install the plate (B) in its position and screw down the (A) screw
Fix the fitting to tthe recess box with the supplied screw
Insert the correct lamp
Close the fitting
NOTES: Use the appropriate recess box for recess
Do not exceed the maximum allowed wattage
Disconnect the fitting before the maintenance
The fitting is suitable to the mounting on normal inflammable surfaces
Installation should be carried out by a suitably qualified person in accordance
with good electrical practice and the appropiate national wiring regulations
The respect of these instructions is very important for the fitting life
and for the people safety.Therefore, they must be retained
ISTRMINIBTON REV.6 08/09