tecnical specification - elm srl
Transcript
tecnical specification - elm srl
Tempo frenatura MFC-MFD Torque Working cycle • Applicazioni Segatrici, macchine per legno, vibrovagli, centrifughe, rettificatrici, mole. Motor sp eed Taglia freno consigliata System control automatically the start stop circuit of main motor, and drive the interlock time of auxiliary relay in order to meet proper safety cycle time. It is possibile to select different operating mode with Dip switches for different load applied to the motor. Braking Working cycle it is full controlled by internal logic . At STOP command the main contactor K1 drop, the auxiliary contact (4/5) close and inform the MFC module that the stopping cycle has been initiated. The internal control start the braking cycle. First it is opened the interlock contact (3/1) for prevent operation of motor contactor as long the braking cycle are ultimate. After time T1 the braking contactor K2 (Internal in MFC type or external in MFD) is drive ON and connect the output to the motor. After the time T2 the converter bridge it is activated and inject the Braking current in the motor .The braking action start for the adjiusted Braking time. The braking action depend now from the different braking mode set . BraKing Time and torque are settable by different front access trimmers. Braking Time SW2 (A/M) OFF: Time is settable in the range 1 to 10 second ON: Time is settable in the range 5 to 50 second Start mode JP2 (internal board) OFF: Braking cycle active on mains return ON: Braking cycle active only after a start Cicle • Applications Saw, wood machines, vibratory screeners, centrifugal machine, grinding machine torque With Built-in contactor n pensatio P1 Com Versione con contattore esterno With External contactor Potenza motore 400V KW Corrente nominale motore A Motor power Nominal cuurrent Dimensioni (mm) Dimensions MFC MFC MFC MFC MFC 20 30 50 75 100 7,5 15 22 37 55 14,8 28,5 42 69 100 106 106 106 106 106 170 170 170 170 170 95 95 160 160 160 MFD MFD MFD MFD MFD MFD MFD MFD 50 75 100 150 200 300 400 500 22 37 55 75 110 160 200 250 42 69 100 131 195 285 370 460 106 106 106 166 166 166 206 206 170 170 170 240 240 240 280 280 120 120 120 190 190 190 210 210 me ing ti P3 Brak Fig. 4 frenatura MFR Modulo di frenatura MFR Tempi di decelerazione regolabili Arresto “Ruota libera” Coppia frenante regolabile • Possibilità di impostare con dip switch • Stop automatico della corrente a motore fermo oppure dopo il tempo impostato Braking module • Funzionamento con compensazione per riduzione rumore a bassi giri Deceleration time adjustable Free wheel stop Braking torque adjustable Tarature: tempo frenatura, coppia frenatura, compensazione giri Protezioni: Fusibile interno, sovratensione semiconduttori Braking torque Braking torque depends from braking Current injected in the motor. Stopping time depends from Braking current and load of the motor. It is possible to set different profile of the out current to meet the different load applied to the motor. Versione con contattore integrato Tempo Setting caracteristics Type of Stop SW1 (FS-T) Auto: Current stop when stopped the motor ; Braking time interlock continued just end of setted time. Mano: Current stop at the end of setted Braking time. Brake model P2 Braking modules 20 - 500A 230 / 440V DC injection current Coppia frenante Modo di start JP2 OFF: Il sistema attiva la frenatura al ritorno rete ON: Il sistema attiva la frenatura solo dopo un avviamento Fig. 3 Torque Operating logic Tempo di arresto SW2 OFF: Il tempo impostabile da trimmer è tra 1 e 10 secondi ON: Il tempo impostabile da trimmer è tra 5 e 50 secondi Motor power king tim P3 Bra P2 Il ciclo di lavoro è completamente gestito dalla logica interna. Al comando di STOP il contattore principale K1 di comando del motore si diseccita, chiude il suo contatto ausiliario (4 / 5) che informa il modulo MFC dell’inizio della fase di arresto. Il controllo interno a microprocessore attiva il ciclo di frenatura che inibisce la abilitazione all’avviamento sino a ciclo completato (3/1) Si inserisce dopo il tempo T1 il contattore di frenatura K2, interno nella versione MFC oppure esterno nella versione MFD, che connette il motore al modulo di frenatura. Dopo il tempo T2 si attiva il ponte convertitore di potenza che inietta la corrente di frenatura per il tempo del ciclo di frenatura impostato. A seconda dell’impostazione programmata la coppia frenante avrà l’andamento più adatto al tipo di carico da frenare. Il tempo e la coppia di frenatura sono impostabili separatamente. Modo di Arresto SW1 Auto: La corrente frenante cessa a motore fermo; il ciclo di frenatura continua sino al termine impostato. Mano: La corrente frenante cessa al termine del tempo di frenatura impostato. Potenza motore sation pen P1 Com e Torque Rpm Logica di funzionamento Funzioni e caratteristiche delle tarature P2+P1 P2 La più semplice soluzione per frenare un motore a corrente alternata senza stress meccanici La coppia frenante dipende dalla corrente iniettata nel motore. Il tempo di arresto risultante dipende dalla corrente frenante e dal carico connesso al motore. La scelta del profilo della coppia frenante è possibile per adattare l’azione frenante alle particolari esigenze di carico me Tempo 20 - 500A 230 / 440V ad iniezione di corrente DC Gestione del ciclo torque Braking eed Motor sp Torque Rpm Moduli di frenatura elettronici Il sistema controlla automaticamente il circuito di marcia/arresto del motore imponendo i tempi di arresto e di sicurezza del ciclo. Sono inoltre possibili differenti modi di lavoro selezionabili con DIP Switches interni per differenti tipi di carichi motore da gestire. king ti P3 Bra Fig. 2 Freno tipo Brake type MFR 10 MFR 20 Corrente nominale Nominal cuurrent t.amb. In Servizio normale Servizio pesante Standard use (400) Dimensioni (mm) Dimensions (mm) Heavy duty (400) Peso Weight • Operation mode by dip switch • Current stop automatically when motor stops or after time setting • Programmable DC slope decreasing for reduce mechanical noise at low speed Setting: Braking time, Braking torque, speed compensation Protections: Internal fuse, overvoltage semiconductor A A KW 10 20 8,5 20 4 10 HP A 5,5 6,6 15 15,5 KW 3 7,5 HP L 4 90 10 105 H 105 105 W 75 75 Kg 0,6 0,6 Tempo frenatura MFC-MFD Torque Working cycle • Applicazioni Segatrici, macchine per legno, vibrovagli, centrifughe, rettificatrici, mole. Motor sp eed Taglia freno consigliata System control automatically the start stop circuit of main motor, and drive the interlock time of auxiliary relay in order to meet proper safety cycle time. It is possibile to select different operating mode with Dip switches for different load applied to the motor. Braking Working cycle it is full controlled by internal logic . At STOP command the main contactor K1 drop, the auxiliary contact (4/5) close and inform the MFC module that the stopping cycle has been initiated. The internal control start the braking cycle. First it is opened the interlock contact (3/1) for prevent operation of motor contactor as long the braking cycle are ultimate. After time T1 the braking contactor K2 (Internal in MFC type or external in MFD) is drive ON and connect the output to the motor. After the time T2 the converter bridge it is activated and inject the Braking current in the motor .The braking action start for the adjiusted Braking time. The braking action depend now from the different braking mode set . BraKing Time and torque are settable by different front access trimmers. Braking Time SW2 (A/M) OFF: Time is settable in the range 1 to 10 second ON: Time is settable in the range 5 to 50 second Start mode JP2 (internal board) OFF: Braking cycle active on mains return ON: Braking cycle active only after a start Cicle • Applications Saw, wood machines, vibratory screeners, centrifugal machine, grinding machine torque With Built-in contactor n pensatio P1 Com Versione con contattore esterno With External contactor Potenza motore 400V KW Corrente nominale motore A Motor power Nominal cuurrent Dimensioni (mm) Dimensions MFC MFC MFC MFC MFC 20 30 50 75 100 7,5 15 22 37 55 14,8 28,5 42 69 100 106 106 106 106 106 170 170 170 170 170 95 95 160 160 160 MFD MFD MFD MFD MFD MFD MFD MFD 50 75 100 150 200 300 400 500 22 37 55 75 110 160 200 250 42 69 100 131 195 285 370 460 106 106 106 166 166 166 206 206 170 170 170 240 240 240 280 280 120 120 120 190 190 190 210 210 me ing ti P3 Brak Fig. 4 frenatura MFR Modulo di frenatura MFR Tempi di decelerazione regolabili Arresto “Ruota libera” Coppia frenante regolabile • Possibilità di impostare con dip switch • Stop automatico della corrente a motore fermo oppure dopo il tempo impostato Braking module • Funzionamento con compensazione per riduzione rumore a bassi giri Deceleration time adjustable Free wheel stop Braking torque adjustable Tarature: tempo frenatura, coppia frenatura, compensazione giri Protezioni: Fusibile interno, sovratensione semiconduttori Braking torque Braking torque depends from braking Current injected in the motor. Stopping time depends from Braking current and load of the motor. It is possible to set different profile of the out current to meet the different load applied to the motor. Versione con contattore integrato Tempo Setting caracteristics Type of Stop SW1 (FS-T) Auto: Current stop when stopped the motor ; Braking time interlock continued just end of setted time. Mano: Current stop at the end of setted Braking time. Brake model P2 Braking modules 20 - 500A 230 / 440V DC injection current Coppia frenante Modo di start JP2 OFF: Il sistema attiva la frenatura al ritorno rete ON: Il sistema attiva la frenatura solo dopo un avviamento Fig. 3 Torque Operating logic Tempo di arresto SW2 OFF: Il tempo impostabile da trimmer è tra 1 e 10 secondi ON: Il tempo impostabile da trimmer è tra 5 e 50 secondi Motor power king tim P3 Bra P2 Il ciclo di lavoro è completamente gestito dalla logica interna. Al comando di STOP il contattore principale K1 di comando del motore si diseccita, chiude il suo contatto ausiliario (4 / 5) che informa il modulo MFC dell’inizio della fase di arresto. Il controllo interno a microprocessore attiva il ciclo di frenatura che inibisce la abilitazione all’avviamento sino a ciclo completato (3/1) Si inserisce dopo il tempo T1 il contattore di frenatura K2, interno nella versione MFC oppure esterno nella versione MFD, che connette il motore al modulo di frenatura. Dopo il tempo T2 si attiva il ponte convertitore di potenza che inietta la corrente di frenatura per il tempo del ciclo di frenatura impostato. A seconda dell’impostazione programmata la coppia frenante avrà l’andamento più adatto al tipo di carico da frenare. Il tempo e la coppia di frenatura sono impostabili separatamente. Modo di Arresto SW1 Auto: La corrente frenante cessa a motore fermo; il ciclo di frenatura continua sino al termine impostato. Mano: La corrente frenante cessa al termine del tempo di frenatura impostato. Potenza motore sation pen P1 Com e Torque Rpm Logica di funzionamento Funzioni e caratteristiche delle tarature P2+P1 P2 La più semplice soluzione per frenare un motore a corrente alternata senza stress meccanici La coppia frenante dipende dalla corrente iniettata nel motore. Il tempo di arresto risultante dipende dalla corrente frenante e dal carico connesso al motore. La scelta del profilo della coppia frenante è possibile per adattare l’azione frenante alle particolari esigenze di carico me Tempo 20 - 500A 230 / 440V ad iniezione di corrente DC Gestione del ciclo torque Braking eed Motor sp Torque Rpm Moduli di frenatura elettronici Il sistema controlla automaticamente il circuito di marcia/arresto del motore imponendo i tempi di arresto e di sicurezza del ciclo. Sono inoltre possibili differenti modi di lavoro selezionabili con DIP Switches interni per differenti tipi di carichi motore da gestire. king ti P3 Bra Fig. 2 Freno tipo Brake type MFR 10 MFR 20 Corrente nominale Nominal cuurrent t.amb. In Servizio normale Servizio pesante Standard use (400) Dimensioni (mm) Dimensions (mm) Heavy duty (400) Peso Weight • Operation mode by dip switch • Current stop automatically when motor stops or after time setting • Programmable DC slope decreasing for reduce mechanical noise at low speed Setting: Braking time, Braking torque, speed compensation Protections: Internal fuse, overvoltage semiconductor A A KW 10 20 8,5 20 4 10 HP A 5,5 6,6 15 15,5 KW 3 7,5 HP L 4 90 10 105 H 105 105 W 75 75 Kg 0,6 0,6 ELM S.r.l. Elettronica Industriale via G. da Verrazzano, 44/46 - 10042 Nichelino To - tel. +39 011 627 22 94 - Fax +39 011 680 15 97 - [email protected] - www.elm.it