Tabelle di dimensionamento WR-T 2009 Valori di

Transcript

Tabelle di dimensionamento WR-T 2009 Valori di
FasteningSystems
Tabelle di dimensionamento
Timber Work
WR-T
2009
Valori di calcolo
Legno massiccio
Legno lamellare
Legno lamellare
C
GL
GL
24
24c
30
28c
24h
32c
28h
36c
32h
36h
rk (kg/m3) 350
380
410
430
450
Fissaggio con sollecitazione di trazione (mezzo filetto per elemento)
WR-T-9xL
Vite
WR-T-9x250
WR-T-9x300
WR-T-9x350
WR-T-9x400
WR-T-9x450
WR-T-9x500
Rt,u,k
l
lef
mm
mm
250
300
350
400
450
500
125
150
175
200
225
250
WR-T-13xL
Vite
WR-T-13x400
WR-T-13x500
WR-T-13x600
WR-T-13x700
WR-T-13x800
WR-T-13x900
WR-T-13x1000
Rax,k (kN)
angolo con la fibra: 45-90°
h at lef
kN
32.0
32.0
32.0
32.0
32.0
32.0
mm
rk
125
150
175
200
225
250
350
lef
mm
mm
400
500
600
700
800
900
1000
200
250
300
350
400
450
500
50.0
50.0
50.0
50.0
50.0
50.0
50.0
mm
410
14.6
17.5
20.5
23.4
26.3
29.2
17.0
20.4
23.8
27.2
30.6
34.0
430
18.7
22.5
26.2
30.0
33.7
37.4
450
20.5
24.6
28.7
32.8
36.9
41.0
Rax,k (kN)
angolo con la fibra: 45-90°
h at lef
kN
380
12.4
14.9
17.4
19.8
22.3
24.8
Rt,u,k
l
Tabella 1
rk
200
250
300
350
400
450
500
350
25.5
31.9
38.2
44.6
51.0
57.3
63.7
380
410
30.0
37.5
45.1
52.6
60.1
67.6
75.1
35.0
43.7
52.4
61.2
69.9
78.7
87.4
430
38.5
48.1
57.7
67.3
76.9
86.5
96.1
450
42.1
52.7
63.2
73.7
84.2
94.8
105.3
Rax,d = min
Rax,k x kmod / gM1
Rt,u,k / gM2
gM1 = 1,3
gM2 = 1,1
Fissaggio con sollecitazione di scorrimento (mezzo filetto per elemento)
WR-T-9xL
Vite
WR-T-9x250
WR-T-9x300
WR-T-9x350
WR-T-9x400
WR-T-9x450
WR-T-9x500
WR-T-13xL
Vite
WR-T-13x400
WR-T-13x500
WR-T-13x600
WR-T-13x700
WR-T-13x800
WR-T-13x900
WR-T-13x1000
Note
sdo, 12.02.2010
l
mm
250
300
350
400
450
500
lef
mm
125
150
175
200
225
250
Rt,V,k
kN
22.6
22.6
22.6
22.6
22.6
22.6
h at lef
mm
95
113
131
148
166
184
l
lef
Rt,V,k
h at lef
mm
mm
kN
mm
400
500
600
700
800
900
1000
200
250
300
350
400
450
500
35.4
35.4
35.4
35.4
35.4
35.4
35.4
152
188
223
258
294
329
365
Tabella 2
Rax,V,k (kN)
rk
350
8.8
10.5
12.3
14.0
15.8
17.5
380
10.3
12.4
14.5
16.5
18.6
20.7
rk
350
380
410
12.0
14.4
16.8
19.3
21.7
24.1
430
13.2
15.9
18.5
21.2
23.8
26.5
450
14.5
17.4
20.3
23.2
26.1
29.0
430
450
Rax,V,k (kN)
18.0
22.5
27.0
31.5
36.0
40.5
45.0
21.2
26.5
31.9
37.2
42.5
47.8
53.1
410
24.7
30.9
37.1
43.3
49.4
55.6
61.8
27.2
34.0
40.8
47.6
54.4
61.2
68.0
29.8
37.2
44.7
52.1
59.6
67.0
74.5
RV,d = min
Rax,V,k x kmod / gM1
Rt,V,k / gM2
gM1 = 1,3
gM2 = 1,1
- valori basati sulla norma "gutachtliche Stellungnahme"
670_WT_T_WR_T of Univ.-Prof. Dr.-Ing. H. J. Blass dd 30.06.2009
- valori validi per collegamenti quando la vite è stata posizionata
metà-metà su ciascun pezzo di legno
- la geometria del collegamento deve essere conforme al relativo schema
- il calcolo dei valori progettuali deve essere conforme alle indicazioni riportate nei riquadri accanto alle tabelle
- ciascun collegamento deve contenere almeno due piani di taglio
- la capacità della vite è limitata alla resistenza dell'acciaio
- tutti i calcoli devono essere verificati e firmati dall'ingegnere
responsabile del progetto prima di eseguire il lavoro.
Con riserva di modifiche tecniche
Tabelle di dimensionamento WR Nov 2009.xls; Valori di calcolo
1/3
FasteningSystems
Tabelle di dimensionamento
Timber Work
WR-T
2009
Valori di calcolo
Legno massiccio
Legno lamellare
Legno lamellare
C
GL
GL
24
24c
30
28c
24h
32c
28h
36c
32h
36h
rk (kg/m3) 350
380
410
430
450
Fissaggio di piastra in acciaio (sollecitazione di taglio)
WR-T-9xL
Vite
l
lef
Rt,V,k
hmin
mm
mm
kN
mm
WR-T-9x250
WR-T-9x300
WR-T-9x350
WR-T-9x400
WR-T-9x450
WR-T-9x500
250
300
350
400
450
500
WR-T-13xL
l
lef
Rt,V,k
hmin
mm
mm
kN
mm
Vite
WR-T-13x400
WR-T-13x500
WR-T-13x600
WR-T-13x700
WR-T-13x800
WR-T-13x900
WR-T-13x1000
400
500
600
700
800
900
1000
230
280
330
380
430
480
385
485
585
685
785
885
985
22.6
22.6
22.6
22.6
22.6
22.6
35.4
35.4
35.4
35.4
35.4
35.4
35.4
dp=
20 mm
Rax,V,k (kN)
rk
170
210
240
280
310
350
350
16.1
19.6
23.2
26.7
30.2
33.7
380
410
19.0
23.2
27.3
31.4
35.6
39.7
22.1
27.0
31.8
36.6
41.4
46.2
430
24.4
29.7
34.9
40.2
45.5
50.8
450
26.7
32.5
38.3
44.1
49.9
55.7
Posiz. di inserimento:
testa della vite a livello
con la piastra di acciaio
Rax,V,k (kN)
rk
280
350
420
490
570
640
710
350
34.7
43.7
52.7
61.7
70.7
79.7
88.7
380
410
430
450
40.9
51.5
62.1
72.7
83.4
94.0
104.6
47.6
60.0
72.3
84.7
97.0
109.4
121.8
52.3
65.9
79.5
93.1
106.7
120.3
133.9
57.3
72.2
87.1
102.0
116.9
131.8
146.7
RV,d = min
Rax,V,k x kmod / gM1
Rt,V,k / gM2
gM1 = 1,3
gM2 = 1,1
Fissaggio di travi principali / secondarie
WR-T-9xL
Vite
WR-T-9x250
WR-T-9x300
WR-T-9x350
WR-T-9x400
WR-T-9x450
WR-T-9x500
WR-T-13xL
l
mm
250
300
350
400
450
500
l
lef
mm
125
150
175
200
225
250
lef
Rt,V,k
h at lef
m
kN
mm
mm
45.3
191
95
45.3
226 113
45.3
261 131
45.3
297 148
45.3
332 166
45.3
368 184
Rki,V,k
Rt,V,k
Vite
WR-T-13x400
mm
400
mm
200
kN
70.7
WR-T-13x500
WR-T-13x600
WR-T-13x700
WR-T-13x800
500
600
700
800
250
300
350
400
70.7
70.7
70.7
70.7
WR-T-13x900
WR-T-13x1000
900
1000
450
500
70.7
70.7
h at lef
350
17.5
21.0
24.6
28.1
31.6
35.1
20.0
m
mm
mm
297 148
Tabella 4
Rax,V,k (kN)
380
410
430
20.7
24.1
26.5
24.8
28.9
31.8
28.9
33.7
37.1
33.1
38.5
42.4
37.2
43.3
47.7
41.4
48.1
53.0
20.4
20.7
20.9
450
29.0
34.8
40.6
46.4
52.2
58.0
21.1
Spaziatura minima (mm)
WR-T- WR-T9xL
13xL
27
39
23
33
Rax,V,k (kN)
350
36.0
380
42.5
410
49.4
430
54.4
450
59.6
45.0
54.1
63.1
72.1
53.1
63.7
74.3
85.0
61.8
74.2
86.5
98.9
68.0
81.6
95.2
108.8
74.5
89.3
104.2
119.1
650 325
81.1
95.6 111.3
721 361
90.1 106.2 123.6
Rki,V,k
51.2
52.1
52.8
-La trave principale deve avere adeguati vincoli torsionali.
122.4
136.0
53.3
134.0
148.9
53.8
368
438
509
580
184
219
254
290
Fissaggio con sollecitazione di taglio (mezzo filetto per elemento)
Vite
WR-T-9xL
WR-T-13xL
Note
sdo, 12.02.2010
Tabella 3
kN
6.86
kN
7.57
RV,k
kN
8.13
kN
8.33
kN
8.52
13.6
15.0
15.6
16.0
16.3
a2,c
a90
RV,d = min
Rax,V,k x kmod / gM1
Rt,V,k / gM2
Rki,V,k / gM2
gM1 = 1,3
gM2 = 1,1
Tabella 5
- valori basati sulla norma "gutachtliche Stellungnahme"
RV,k x kmod / gM1
RV,d =
670_WT_T_WR_T of Univ.-Prof. Dr.-Ing. H. J. Blass dd 30.06.2009
- valori validi per collegamenti quando la vite è stata posizionata
gM1 = 1,1
metà-metà su ciascun pezzo di legno
- la geometria del collegamento deve essere conforme al relativo schema
- il calcolo dei valori progettuali deve essere conforme alle indicazioni riportate nei riquadri accanto alle tabelle
- ciascun collegamento deve contenere almeno due piani di taglio
- la capacità della vite è limitata alla resistenza dell'acciaio
- tutti i calcoli devono essere verificati e firmati dall'ingegnere
responsabile del progetto prima di eseguire il lavoro.
Con riserva di modifiche tecniche
Tabelle di dimensionamento WR Nov 2009.xls; Valori di calcolo
2/3
FasteningSystems
Timber Work
Tabelle di dimensionamento WR
2009
Distanze e spaziature
WR-T-9xL
d
mm
Assiale
9
II fibra
a1
L fibra
a2
a2, red.
estremità sollecitataa1,t
estremità scarica a1,c
bordo sollecitato
a2,t
bordo scarico
a2,c
d
5
mm
45
5
45
2.5
23
5
45
3
27
Connessione a taglio
< 420 kg/m3
con perforazione pilota
senza perforazione pilota
0
45
90
0
45
90
d
d
(3+2cos)
45
40
27
(5+7cos)
108
90
45
3
27
27
27
5
45
45
45
(7+5cos)
108
95
63
(10+5cos)
135
122
90
7
63
63
63
10
90
90
90
(3+4sin)
27
52
63
(5+5sin)
45
77
90
3
27
27
27
5
45
45
45
WR-T-13xL
d
mm
Assiale
13
II fibra
a1
L fibra
a2
a2, red.
estremità sollecitataa1,t
estremità scarica a1,c
bordo sollecitato
a2,t
bordo scarico
a2,c
d
5
mm
65
5
65
2.5
33
5
65
3
39
Connessione a taglio
< 420 kg/m3
con perforazione pilota
senza perforazione pilota
0
45
90
0
45
90
d
d
(3+2cos)
65
57
39
(5+7cos)
156
129
65
3
39
39
39
5
65
65
65
(7+5cos)
156
137
91
(10+5cos)
195
176
130
7
91
91
91
10
130
130
130
(3+4sin)
39
76
91
(5+5sin)
65
111
130
3
39
39
39
5
65
65
65
Distanze e spaziature per viti incrociate
Assiale
WR-T-9xL
a1
9
WR-T-13xL
13
Note
sdo, 12.02.2010
d
mm
90
a = angolo di incrocio
mm
75
60
45
30
15
0
5
45
23
26
30
34
38
41
45
a2,red
2.5
23
14
14
15
17
19
21
23
a2
5.0
45
23
26
30
34
38
41
45
a1
5
65
33
38
43
49
54
60
65
a2,red
2.5
33
20
20
22
24
27
30
33
a2
5.0
65
33
38
43
49
54
60
65
- valori basati sulla norma "gutachtliche Stellungnahme"
670_WT_T_WR_T of Univ.-Prof. Dr.-Ing. H. J. Blass dd 30.06.2009
- considerare gli spessori minimi richiesti per ciascun elemento di legno
- tutti i calcoli devono essere verificati e firmati dall'ingegnere responsabile
del progetto prima di eseguire il lavoro.
Con riserva di modifiche tecniche.
Tabelle di dimensionamento WR Nov 2009.xls; Distanze
3/3