Tabelle di dimensionamento WR-T 2009 Valori di
Transcript
Tabelle di dimensionamento WR-T 2009 Valori di
FasteningSystems Tabelle di dimensionamento Timber Work WR-T 2009 Valori di calcolo Legno massiccio Legno lamellare Legno lamellare C GL GL 24 24c 30 28c 24h 32c 28h 36c 32h 36h rk (kg/m3) 350 380 410 430 450 Fissaggio con sollecitazione di trazione (mezzo filetto per elemento) WR-T-9xL Vite WR-T-9x250 WR-T-9x300 WR-T-9x350 WR-T-9x400 WR-T-9x450 WR-T-9x500 Rt,u,k l lef mm mm 250 300 350 400 450 500 125 150 175 200 225 250 WR-T-13xL Vite WR-T-13x400 WR-T-13x500 WR-T-13x600 WR-T-13x700 WR-T-13x800 WR-T-13x900 WR-T-13x1000 Rax,k (kN) angolo con la fibra: 45-90° h at lef kN 32.0 32.0 32.0 32.0 32.0 32.0 mm rk 125 150 175 200 225 250 350 lef mm mm 400 500 600 700 800 900 1000 200 250 300 350 400 450 500 50.0 50.0 50.0 50.0 50.0 50.0 50.0 mm 410 14.6 17.5 20.5 23.4 26.3 29.2 17.0 20.4 23.8 27.2 30.6 34.0 430 18.7 22.5 26.2 30.0 33.7 37.4 450 20.5 24.6 28.7 32.8 36.9 41.0 Rax,k (kN) angolo con la fibra: 45-90° h at lef kN 380 12.4 14.9 17.4 19.8 22.3 24.8 Rt,u,k l Tabella 1 rk 200 250 300 350 400 450 500 350 25.5 31.9 38.2 44.6 51.0 57.3 63.7 380 410 30.0 37.5 45.1 52.6 60.1 67.6 75.1 35.0 43.7 52.4 61.2 69.9 78.7 87.4 430 38.5 48.1 57.7 67.3 76.9 86.5 96.1 450 42.1 52.7 63.2 73.7 84.2 94.8 105.3 Rax,d = min Rax,k x kmod / gM1 Rt,u,k / gM2 gM1 = 1,3 gM2 = 1,1 Fissaggio con sollecitazione di scorrimento (mezzo filetto per elemento) WR-T-9xL Vite WR-T-9x250 WR-T-9x300 WR-T-9x350 WR-T-9x400 WR-T-9x450 WR-T-9x500 WR-T-13xL Vite WR-T-13x400 WR-T-13x500 WR-T-13x600 WR-T-13x700 WR-T-13x800 WR-T-13x900 WR-T-13x1000 Note sdo, 12.02.2010 l mm 250 300 350 400 450 500 lef mm 125 150 175 200 225 250 Rt,V,k kN 22.6 22.6 22.6 22.6 22.6 22.6 h at lef mm 95 113 131 148 166 184 l lef Rt,V,k h at lef mm mm kN mm 400 500 600 700 800 900 1000 200 250 300 350 400 450 500 35.4 35.4 35.4 35.4 35.4 35.4 35.4 152 188 223 258 294 329 365 Tabella 2 Rax,V,k (kN) rk 350 8.8 10.5 12.3 14.0 15.8 17.5 380 10.3 12.4 14.5 16.5 18.6 20.7 rk 350 380 410 12.0 14.4 16.8 19.3 21.7 24.1 430 13.2 15.9 18.5 21.2 23.8 26.5 450 14.5 17.4 20.3 23.2 26.1 29.0 430 450 Rax,V,k (kN) 18.0 22.5 27.0 31.5 36.0 40.5 45.0 21.2 26.5 31.9 37.2 42.5 47.8 53.1 410 24.7 30.9 37.1 43.3 49.4 55.6 61.8 27.2 34.0 40.8 47.6 54.4 61.2 68.0 29.8 37.2 44.7 52.1 59.6 67.0 74.5 RV,d = min Rax,V,k x kmod / gM1 Rt,V,k / gM2 gM1 = 1,3 gM2 = 1,1 - valori basati sulla norma "gutachtliche Stellungnahme" 670_WT_T_WR_T of Univ.-Prof. Dr.-Ing. H. J. Blass dd 30.06.2009 - valori validi per collegamenti quando la vite è stata posizionata metà-metà su ciascun pezzo di legno - la geometria del collegamento deve essere conforme al relativo schema - il calcolo dei valori progettuali deve essere conforme alle indicazioni riportate nei riquadri accanto alle tabelle - ciascun collegamento deve contenere almeno due piani di taglio - la capacità della vite è limitata alla resistenza dell'acciaio - tutti i calcoli devono essere verificati e firmati dall'ingegnere responsabile del progetto prima di eseguire il lavoro. Con riserva di modifiche tecniche Tabelle di dimensionamento WR Nov 2009.xls; Valori di calcolo 1/3 FasteningSystems Tabelle di dimensionamento Timber Work WR-T 2009 Valori di calcolo Legno massiccio Legno lamellare Legno lamellare C GL GL 24 24c 30 28c 24h 32c 28h 36c 32h 36h rk (kg/m3) 350 380 410 430 450 Fissaggio di piastra in acciaio (sollecitazione di taglio) WR-T-9xL Vite l lef Rt,V,k hmin mm mm kN mm WR-T-9x250 WR-T-9x300 WR-T-9x350 WR-T-9x400 WR-T-9x450 WR-T-9x500 250 300 350 400 450 500 WR-T-13xL l lef Rt,V,k hmin mm mm kN mm Vite WR-T-13x400 WR-T-13x500 WR-T-13x600 WR-T-13x700 WR-T-13x800 WR-T-13x900 WR-T-13x1000 400 500 600 700 800 900 1000 230 280 330 380 430 480 385 485 585 685 785 885 985 22.6 22.6 22.6 22.6 22.6 22.6 35.4 35.4 35.4 35.4 35.4 35.4 35.4 dp= 20 mm Rax,V,k (kN) rk 170 210 240 280 310 350 350 16.1 19.6 23.2 26.7 30.2 33.7 380 410 19.0 23.2 27.3 31.4 35.6 39.7 22.1 27.0 31.8 36.6 41.4 46.2 430 24.4 29.7 34.9 40.2 45.5 50.8 450 26.7 32.5 38.3 44.1 49.9 55.7 Posiz. di inserimento: testa della vite a livello con la piastra di acciaio Rax,V,k (kN) rk 280 350 420 490 570 640 710 350 34.7 43.7 52.7 61.7 70.7 79.7 88.7 380 410 430 450 40.9 51.5 62.1 72.7 83.4 94.0 104.6 47.6 60.0 72.3 84.7 97.0 109.4 121.8 52.3 65.9 79.5 93.1 106.7 120.3 133.9 57.3 72.2 87.1 102.0 116.9 131.8 146.7 RV,d = min Rax,V,k x kmod / gM1 Rt,V,k / gM2 gM1 = 1,3 gM2 = 1,1 Fissaggio di travi principali / secondarie WR-T-9xL Vite WR-T-9x250 WR-T-9x300 WR-T-9x350 WR-T-9x400 WR-T-9x450 WR-T-9x500 WR-T-13xL l mm 250 300 350 400 450 500 l lef mm 125 150 175 200 225 250 lef Rt,V,k h at lef m kN mm mm 45.3 191 95 45.3 226 113 45.3 261 131 45.3 297 148 45.3 332 166 45.3 368 184 Rki,V,k Rt,V,k Vite WR-T-13x400 mm 400 mm 200 kN 70.7 WR-T-13x500 WR-T-13x600 WR-T-13x700 WR-T-13x800 500 600 700 800 250 300 350 400 70.7 70.7 70.7 70.7 WR-T-13x900 WR-T-13x1000 900 1000 450 500 70.7 70.7 h at lef 350 17.5 21.0 24.6 28.1 31.6 35.1 20.0 m mm mm 297 148 Tabella 4 Rax,V,k (kN) 380 410 430 20.7 24.1 26.5 24.8 28.9 31.8 28.9 33.7 37.1 33.1 38.5 42.4 37.2 43.3 47.7 41.4 48.1 53.0 20.4 20.7 20.9 450 29.0 34.8 40.6 46.4 52.2 58.0 21.1 Spaziatura minima (mm) WR-T- WR-T9xL 13xL 27 39 23 33 Rax,V,k (kN) 350 36.0 380 42.5 410 49.4 430 54.4 450 59.6 45.0 54.1 63.1 72.1 53.1 63.7 74.3 85.0 61.8 74.2 86.5 98.9 68.0 81.6 95.2 108.8 74.5 89.3 104.2 119.1 650 325 81.1 95.6 111.3 721 361 90.1 106.2 123.6 Rki,V,k 51.2 52.1 52.8 -La trave principale deve avere adeguati vincoli torsionali. 122.4 136.0 53.3 134.0 148.9 53.8 368 438 509 580 184 219 254 290 Fissaggio con sollecitazione di taglio (mezzo filetto per elemento) Vite WR-T-9xL WR-T-13xL Note sdo, 12.02.2010 Tabella 3 kN 6.86 kN 7.57 RV,k kN 8.13 kN 8.33 kN 8.52 13.6 15.0 15.6 16.0 16.3 a2,c a90 RV,d = min Rax,V,k x kmod / gM1 Rt,V,k / gM2 Rki,V,k / gM2 gM1 = 1,3 gM2 = 1,1 Tabella 5 - valori basati sulla norma "gutachtliche Stellungnahme" RV,k x kmod / gM1 RV,d = 670_WT_T_WR_T of Univ.-Prof. Dr.-Ing. H. J. Blass dd 30.06.2009 - valori validi per collegamenti quando la vite è stata posizionata gM1 = 1,1 metà-metà su ciascun pezzo di legno - la geometria del collegamento deve essere conforme al relativo schema - il calcolo dei valori progettuali deve essere conforme alle indicazioni riportate nei riquadri accanto alle tabelle - ciascun collegamento deve contenere almeno due piani di taglio - la capacità della vite è limitata alla resistenza dell'acciaio - tutti i calcoli devono essere verificati e firmati dall'ingegnere responsabile del progetto prima di eseguire il lavoro. Con riserva di modifiche tecniche Tabelle di dimensionamento WR Nov 2009.xls; Valori di calcolo 2/3 FasteningSystems Timber Work Tabelle di dimensionamento WR 2009 Distanze e spaziature WR-T-9xL d mm Assiale 9 II fibra a1 L fibra a2 a2, red. estremità sollecitataa1,t estremità scarica a1,c bordo sollecitato a2,t bordo scarico a2,c d 5 mm 45 5 45 2.5 23 5 45 3 27 Connessione a taglio < 420 kg/m3 con perforazione pilota senza perforazione pilota 0 45 90 0 45 90 d d (3+2cos) 45 40 27 (5+7cos) 108 90 45 3 27 27 27 5 45 45 45 (7+5cos) 108 95 63 (10+5cos) 135 122 90 7 63 63 63 10 90 90 90 (3+4sin) 27 52 63 (5+5sin) 45 77 90 3 27 27 27 5 45 45 45 WR-T-13xL d mm Assiale 13 II fibra a1 L fibra a2 a2, red. estremità sollecitataa1,t estremità scarica a1,c bordo sollecitato a2,t bordo scarico a2,c d 5 mm 65 5 65 2.5 33 5 65 3 39 Connessione a taglio < 420 kg/m3 con perforazione pilota senza perforazione pilota 0 45 90 0 45 90 d d (3+2cos) 65 57 39 (5+7cos) 156 129 65 3 39 39 39 5 65 65 65 (7+5cos) 156 137 91 (10+5cos) 195 176 130 7 91 91 91 10 130 130 130 (3+4sin) 39 76 91 (5+5sin) 65 111 130 3 39 39 39 5 65 65 65 Distanze e spaziature per viti incrociate Assiale WR-T-9xL a1 9 WR-T-13xL 13 Note sdo, 12.02.2010 d mm 90 a = angolo di incrocio mm 75 60 45 30 15 0 5 45 23 26 30 34 38 41 45 a2,red 2.5 23 14 14 15 17 19 21 23 a2 5.0 45 23 26 30 34 38 41 45 a1 5 65 33 38 43 49 54 60 65 a2,red 2.5 33 20 20 22 24 27 30 33 a2 5.0 65 33 38 43 49 54 60 65 - valori basati sulla norma "gutachtliche Stellungnahme" 670_WT_T_WR_T of Univ.-Prof. Dr.-Ing. H. J. Blass dd 30.06.2009 - considerare gli spessori minimi richiesti per ciascun elemento di legno - tutti i calcoli devono essere verificati e firmati dall'ingegnere responsabile del progetto prima di eseguire il lavoro. Con riserva di modifiche tecniche. Tabelle di dimensionamento WR Nov 2009.xls; Distanze 3/3