STA Interface:A BTL5-F1.0-M....-A-S115 Micropulse

Transcript

STA Interface:A BTL5-F1.0-M....-A-S115 Micropulse
STA
Interface:A
BTL5-F1.0-M....-A-S115
Micropulse transducer BTL
Technical Data
Transducer interface
Input interface
Output signal
max. current load per output
Repeatability
Sampling rate
Supply voltage
Current draw without load
Operating temperature
Storage temperature
Shock load
Vibration
Dielectric constant
Enclosure rating per IEC 60529
Housing material
flange- and tube material
Mounting
Pressure rating
Connection type
Accessories
Balluff GmbH
Schurwaldstrasse 9
73765 Neuhausen a.d.F.
Phone (07158) 173-0 Fax (07158) 5010
F
digital
4 switchpoints
100mA, max.200mA für 4 Ausgänge
+-0,1mm
F standard = 1kHz = < 1400mm
24 V DC ±20%
<100mA
-40...85°C
-40...100°C
100g / 6ms per IEC60068-2-27
12g, 10...2000 Hz per IEC 60068-2-6
500 V (GND to housing)
IP 67 (with BKS-S...IP 67 connector attached)
Anodized aluminum
1.4571 stainless tube,
1.3952 stainless investment cast flange
thread M18x1,5, Flange without mounting surface
600 bar
Connector
Magnets and Connector please order separately
Datenblatt by CD-ROM - 04/2007

Documenti analoghi

UNS2000 Level Switches UNS2000

UNS2000 Level Switches UNS2000 6 switchpoints (see max. switchpoints) and with a length of max 3000 mm. Besides the float operated reed contacts to detect liquid levels, the UNS 2000 can be supplied also with a temperature senso...

Dettagli