1. Manual for the emulator EMUFDD

Transcript

1. Manual for the emulator EMUFDD
EMUFDD_HW_MANUAL
1.
♦
Manual for the emulator EMUFDD
Power supply and connecting the flat cable of the devices
Connecting the devices as in the picture, the pin 1 of flat is colour blue or red. The power
of the devices usually is 4 wires , the 5 V are to be connected as in the picture.
♦
Using the devices
1
MILO snc
SW & HW per automazione
Via Ruggiero Grieco 1/C 41011 Campogalliano -MOCodice Fiscale e P.IVA 03373570369
Tel. 059 528512 Fax. 059 520131 E-mail: [email protected] Web: www.milosrl.it
EMUFDD_HW_MANUAL
1
Led SAVE:
Indicates backup from EMUFDD to USB memory stick
2
Led LOAD:
Indicates loading from USB memory stick to EMUFDD
3
Led ACCESS:
Indicates a request to write or read from CN or PC to EMUFDD
4
Led OFF-LINE: Must be turned ON when you save or load on the USB memory
stick
5
Button SAVE: To save file from EMUFDD to USB memory stick
6
Button LOAD: To load file from USB memory stick to EMUFDD
7
Button DOWN: To scroll through different image files on the memory stick (1
image file has the same capacity of a floppy) up to a maximum of 100 image files,
image files must have the following suffix EMUXX144. IMG, the XX indicates the
number of files, so if you wish to create 100 filenames mast be EMU00144. IMG
up to EMU99144.IMG. The number 144 indicates that we are working with a
1.44 Mb floppy.
8
Button UP: To scroll through different image files on the memory stick (1 image
file has the same capacity of a floppy) up to a maximum of 100 image files, image
files must have the following suffix EMUXX144. IMG, the XX indicates the number
of files, so if you wish to create 100 filenames mast be EMU00144. IMG up to
EMU99144.IMG.. The number 144 indicates that we are working with a 1.44 Mb
floppy.
9
Display for the image file to upload and or to see the file uploaded on EMUFDD
10
Connector for USB
After connecting the device to the CNC or PC , need to check that the EMUFDD to be
seen from the machine, to try one write to the device, if the device is not see by the
CNC, must try to configure it in another way.
2
MILO snc
SW & HW per automazione
Via Ruggiero Grieco 1/C 41011 Campogalliano -MOCodice Fiscale e P.IVA 03373570369
Tel. 059 528512 Fax. 059 520131 E-mail: [email protected] Web: www.milosrl.it
EMUFDD_HW_MANUAL
♦
Load the image file from USB memory stick to EMUFDD
Insert a USB memory stick, push the button load or save (this is used to place off-line
EMUFDD) the red led offline is on, the Display shows CH and scans the image files on
your USB memory stick. With the up and down buttons to scroll through all the image
files from 00 to 99, those on the USB memory stick are shown on the display with two
decimal points bright example 0.1. . Select the file you want to upload, press the LOAD
button until the green led is on and start flashing the yellow led ACCESS. During this
phase, the display shows LO (LOAD), when they turn off the green led of LOAD, and
the yellow of ACCESS, and the red led OFFLINE, you can remove the USB memory stick,
the display alternates between the two central segments of the display, and the number
of image files uploaded.
♦
Save image files from EMUFDD to USB memory stick
Insert a USB memory stick, push the button load or save (this is used to place off-line
EMUFDD) the red led offline is on, the Display shows CH and scans the image files on
your USB memory stick, after scanning, the display will show the internal file of EMUFDD,
to save it on USB memory stick you must press and hold the save button until the green
led is on and start flashing the yellow led ACCESS. During this phase, the display
shows SA (SAVE), when they turn off the green led of LOAD, and the yellow of
ACCESS, and the red led OFFLINE, you can remove the USB memory stick, the display
alternates between the two central segments of the display, and the number of image
files uploaded..
If the file you want to save, is not present on the USB memory stick, is created
automatically by EMUFDD
3
MILO snc
SW & HW per automazione
Via Ruggiero Grieco 1/C 41011 Campogalliano -MOCodice Fiscale e P.IVA 03373570369
Tel. 059 528512 Fax. 059 520131 E-mail: [email protected] Web: www.milosrl.it
EMUFDD_HW_MANUAL
♦
How to setup the EMUFDD
Several kinds of configuration:
Configuration Files:
4
MILO snc
SW & HW per automazione
Via Ruggiero Grieco 1/C 41011 Campogalliano -MOCodice Fiscale e P.IVA 03373570369
Tel. 059 528512 Fax. 059 520131 E-mail: [email protected] Web: www.milosrl.it
EMUFDD_HW_MANUAL
When ordering EMUFDD, are prompted the type of CNC or PC where it wil be installed, but
sometimes you require need change the configuration. This procedure is made entirely by
software, just upload the .cfg file you want to on your USB memory stick, put EMUFDD offline
( led red on) push the button SAVE o LOAD, the EMUFDD charge the new configuration,
delete the file .cfg from the key and reset automatically , for more safety recharge the image
file on EMUFDD.
♦
To check the configuration of the EMUFDD
Push the button LOAD or SAVE (without inverting the USB memory stick ), appears in the
display the following sequence:
Parametro
firmware
drive
seektime
uptime
downtime
gap1
gap2
always
trans
Simbolo
Fn
rn
St
Ut
dt
G1
G2
AL
Tr
parametri
2 3 4 5
2 3 4 5 6 7
000 - 255
000 - 255
000 - 255
000 - 999
000 - 999
0-1
0-1
The most important parameters are the first two, the others are default
5
MILO snc
SW & HW per automazione
Via Ruggiero Grieco 1/C 41011 Campogalliano -MOCodice Fiscale e P.IVA 03373570369
Tel. 059 528512 Fax. 059 520131 E-mail: [email protected] Web: www.milosrl.it
EMUFDD_HW_MANUAL
firmware
drive
TIPO
2
2
2
2
3
3
3
3
3
3
4
4
4
4
5
5
5
5
5
5
2
3
4
5
2
3
4
5
6
7
2
3
4
5
2
3
4
5
6
7
"EMUP0720" SIZE_720
"EMUP0144" SIZE_144
"EMUP1720" SIZE_720
"EMUP1144" SIZE_144
"EMUC0720", SIZE_720
"EMUC0144", SIZE_144
"EMUC1720", SIZE_720
"EMUC1144", SIZE_144
"EMUC2720", SIZE_720
"EMUC2144", SIZE_144
"EMUM0720", SIZE_720
"EMUM0144", SIZE_144
"EMUM1720", SIZE_720
"EMUM1144", SIZE_144
"EMUH0720", SIZE_720
"EMUH0144", SIZE_144
"EMUH1720", SIZE_720
"EMUH1144", SIZE_144
"EMUH2720", SIZE_720
"EMUH2144", SIZE_144
6
MILO snc
SW & HW per automazione
Via Ruggiero Grieco 1/C 41011 Campogalliano -MOCodice Fiscale e P.IVA 03373570369
Tel. 059 528512 Fax. 059 520131 E-mail: [email protected] Web: www.milosrl.it