Roof Fans Ventilation Systems BelAir
Transcript
Roof Fans Ventilation Systems BelAir
Roof Fans Ventilation Systems BelAir Issue 5 EN January 2014 We set benchmarks for the roofs of the world RDA / RDM FDA RGA The premium roof fan line with high value aluminium casing. Easy to fit, easy to maintain. Vertical discharge, The super attenuated unit in a cubic design – for low noise application. Vertical discharge, up to 33,000 m3/h. The advantageous choice with rugged corrosion resistant cowl. Horizontal discharge, up to 35,000 m3/h. up to 57,000 m3/h. The consistent quality strategy of Nicotra Gebhardt has set a benchmark for the world market – but this is just the beginning. Today we offer roof fan systems in a range which always allows a solutions for individual requirements. • Perfect quality for every roof fan line • A consistent accessory system for all ranges • Highest flexibility for individual solutions • Shortest delivery on the fan market The Perfection in Tolerance Class 2 Tolerance classes according to DIN 24166 Deviations per Tolerance Class Performance data 2 3 Flow rate qV ±5 % ±10 % Pressure increase ΔΔp ±5 % ±10 % Power-consumption P ±8 % ±16 % LWA +4 dB +6 dB Noise level Not only do we set standards in reliability and design, but also in the customary high level of data quality of our roof ventilators. This has given us an Tolerance Class 2 according to DIN 24166. In stating this classification we are allowing for a reliable technical comparison of our products. Not that you would expect anything less from us as a premium quality supplier. We will be happy to give you more detailed information about this. The best way is to contact us by telephone. Flow rate Conveying medium Speed control Material d el ste nte Pai ised van Gal stic Pla ium min rter nve e ge driv Vol ta DC r nce ATE X EX- Alu °C °C cha rge sile al i ern Ext ess shl Bru ted gra Inte Dis 120 60 °C h m³/ h m³/ h m³/ h m³/ h m³/ • • • For some sizes • Horizontal sizes • For some types • • • • • • • • • optional • Motor cowl • • Vertical FDA • optional • • • RDM 31-/32-....-.A • ATEX • RDM 32 Horizontaö • • • • • • • • • • • • • • • optional • • • RDA 32 Vertical • For some types RDA RDM Integrated back draught damper 40 000 57. 000 33. 000 13. 00 6.5 00 1.2 RBA Integrated back draught damper • • • • • • • Cowl • • ATEX Horizontaö RGA Simple and reliable fan selection Simple and reliable selection proSELECTA II is a technical selection program that allows you to configure your own individually designed fan. It provides you with the opportunity to choose from the entire range of fan types and their associated options. The result from proSELECTA II is the provision of all the technical data for your fan, including sound level data, dimension specifications and accessories. Apart from that, as a registered user, your purchase prices are provided. Additionally fully dimensioned drawings in dxf format are available, which can be downloaded and transferred straight into your CAD system. So that you can be sure. Models and options that are technically not permissible, are automatically excluded in proSELECTA II. So there is no chance that you will configure a “wrong” device option. During the fan selection process, you can choose any of the standardised ATEX options. Free registration and many advantages You can register as a proSELECTA II user with us, which enables us to offer you faster order processing. What this means for you is: • The complete configuration of your fan with its associated system accessories and belt drive layout. • The possibility to produce fans that operate via a frequency inverter. • The option of saving your own fan configuration on our server. • The opportunity to modify your saved configuration, even over the phone to your Nicotra Gebhardt representative. • Specification • Relative sound power data • Terminal cowl RGA Centrifugal roof extract fan RGA with external rotor motor horizontal discharge cowl made of moulded plastic • Specification • Relative sound power data • Terminal cowl Centrifugal roof extract fan RDM genovent® with IEC standard motor placed out of airstream vertical discharge integrated back draught dampers with silencer lining – RDM 32 • Specification • Relative sound power data • Frequency inverter opperation Centrifugal roof extract fan FDA with external rotor motor vertical discharge low noise execution • Specification • Relative sound power data FDA RDM RDA Centrifugal roof extract fan RDA genovent® with external rotor motor vertical discharge integrated back draught dampers – RDA 31/32 with silencer lining – RDA 32 horizontal discharge – RDA 21 • Specification • Relative sound power data RBA Centrifugal ventilation fanbox RBA with external rotor motor vertical discharge BelAir Ventilation Systems BelAir for living areas on request! • Mechanical accessories • Switches and controllers Accessories Accessories Samples Description Descriptions Specifications Service The silent unit There are cases where a fan has to be silent first. It is for cases like this that the FDA 31 has been designed. A casing equipped with highly efficient lining reduces the discharge sound level. The cubic design of the steel casing in addition integrates the unit into any roof surrounding. This is the reason that thousands of these units are doing their job without drawing attention. Perhaps on one of your roofs soon too … FDA Roof fan line FDA 31 Nicotra Gebhardt external rotor motor Flow rate up to 33,000 m³/h Incredibly silent – incredibly performing The FDA 31 is equipped with a Nicotra Gebhardt external rotor motor. The flow rate is up to 33,000 m³/h. This makes the FDA 31 silent and performing – another master piece coming from Nicotra Gebhardt. 104 Many reasons for choosing the silent unit Using an intelligent concept for the FDA 31 a high level of expectations concerning performance, quality, design and noise comfort is met. Jc ubic design with integrated silencer made of galvanised steel sheet. J the high performance backward curved impeller assures a smooth operation at high efficiency level. Ja wide programme of external rotor motors mainly made by Nicotra Gebhardt. Executions: single speed, 2-speed, voltage controlled by transformer or phase cutting. J s imple installation and inspection. FDA J full range of accessories. 105 Roof Extract Fans / FDA / Technical Data FDA 31-2528 Technical Data in Class 2 acc. to DIN 24166 Curves PolesVoltage/ Fre- Speed Connection quency max. power Nominal consumption current FDA 31- kW 2528-MD• 2528-6D• 2528-GD 2528-4E• 2528-6E• V Hz 1/min Starting/Full qVmaxLWA8 Capa- Protection/WeightMedia load current at qVmax citor Temp. class temp. A m³/h [A1|A2] 4/4 400, 3~ /Y 501420/1260 0.13/0.09 0.40/0.16 2.8 [A3] 6 400, 3~ Y 50 950 0.08 0.28 1.6 [A4|A5] 4/8 400, 3~ YY/Y 50 1430/ 720 0.16/0.05 0.37/0.15 3.0 [A6] 4 230, 1~501380 0.16 0.76 1.7 [A7] 6 230, 1~ 50 910 0.08 0.34 1.7 dB AT mF 1730/1570 60/57 - 1160 49 - 1740/ 880 60/42 - 1690 59 3 1120 48 2 kg °C IP44/F68-20...+60 IP44/F 67 -20...+60 IP44/F 68 -20...+60 IP44/F67-20...+55 IP44/F 67 -20...+60 • (also) stepless speed controllable by tension variation AT All indicated sound values are sound power levels. For more calculations when determining the A-sound pressure level at any distances read the statements on part „Sounds“ in chapter „Description“. Curves in Class 2 acc. to DIN 24166 Pa FDA 31-2528-MD LWA = 8 58 dB 200 54 56 51 150 r1=1.15 kg/m³ Pa [A1] 200 dB 0 Pa 200 0 0 qV 400 0.1 [A6] 100 40 0 0 0 qV 400 0.1 800 0.2 1200 0.3 0.4 42 [A7] 45 60 56 150 1000 m³/h m³/s 800 0.2 36 [A5] FDA 31-2528-6E LWA = 8 46 dB 80 53 600 psF psF m³/h m³/s 40 60 = 57 57 A8 [A4] 42 1200 0.3 0.4 50 49 LW 54 46 800 0.2 60 57 400 0.1 LWA = 8 58 dB 100 54 0 0 qV FDA 31-2528-GD 150 50 FDA 31-2528-4E 20 400 0.1 800 0.2 1200 0.3 0.4 m³/h m³/s 48 59 0 0 qV psF 50 psF 43 25 Pa 0 Pa [A3] 50 psF 8 dB 57 100 200 FDA 31-2528-6D 75 [A2] 0 LWA8 = 4 0 200 0 0 qV 400 0.1 600 800 0.2 1000 m³/h m³/s Accessories Isolator Motor protection unit Transformer 7 taps Transformer 5-steps Speed regulator Speed regulator Speed regulator Speed controller electronic electronic micro processor electronic FDA 31- ESM ETO ETH EPH ESH EPA 2528-MD• 21-0030-6504-0040-8D10-0010-8D35-0010-8D– 83-0050-8D 2528-6D• 21-0030-3501-0040-8D10-0010-8D35-0010-8D– – 2528-GD21-0030-65 03-0040-8D6 –––– 2528-4E• 21-0030-22– 10-0018-5E31-0020-5E03-0010-5E83-0060-5E 2528-6E• 21-0030-22– 10-0018-5E31-0020-5E03-0010-5E– 106 m³/h m³/s Roof Extract Fans / FDA / Technical Data FDA 31-2528 410 704 Dimensions in mm, Subject to change. FDA 31-2528-.. M6 Flat roof upstand Upstand silencer ZBU 01-0040-25 [St] 4 kg ø256 Connection plate 378 330 270 6×M6 ø286 115 650 283 1 When using back draught damper ZLK in connection with silencer upstand ZDS a spacer ZKK is required □400 □710 618 ZKE 11-0250 1.4 kg 130 535 150 ZKF 11-0250 0.7 kg Mating flange 6×ø7 ø256 ø286 ø306 150 340 618 M M 10 10 ZBS 09-0040-2 [Al] 5 kg ø12 ø256 ø286 ø306 330 618 M 750 10 Inlet silencer ø256 ø286 ø345 ZLK 21-0250 9 kg 1 Motor drive shutter ø7 6×M6 ø256 ø286 ø306 ZBS 11-0040 [GFK] 11 kg 200 Flanged inlet cone ø286 ZSG 04-0250 0.4 kg Mesh inlet guard 3× ø7 ø256 ø286 ø306 ø422 ZKK 20-0040 [St] 11 kg 1 Spacer M10 ø11.5 275 10 □319 ø7 70 ZKD 01-0250 2 kg □330 M Soaker sheet WDS 207 ø88 ZDR 30-0250 12 kg 150 6×ø7 180 Automatic shutter 175 150 ZLK 01-0250 6 kg 1 240 □378 □330 25 10 6×ø7 ø256 ø286 ø306 □618 Inclined roof upstand Inlet connection (flexible) 270 650 6 A protection for high speed is only active if Dahlander bridge is on place 378 330 Inclined roof upstand silencer 115 □378 □330 340 ZDS 09-0040-2 [Al] 13 kg 1 M Flat roof upstand tall M ZBS 23-0040 [St] 10 kg 10 618 250 Pressure loss at back draught damper 138 ZDS 01-0040 [Al] 13 kg ZDS 20-0040 [St] 18 kg 1 Accessories / Index 2 inclination in 5° steps up to 45° possible 6 ZBS 01-0040 [Al] 4 kg ZBS 20-0040 [St] 8 kg □395 □330 Mains lead 138 a- Nicotra Gebhardt external rotor motor with impeller fitted directly. Casing equipped with sound absorbing lining. 1600 Accessories FDA 31- ø12 115 M6 440 626 28 32 330 6× 330 386 920 107 Roof Extract Fans / FDA / Technical Data FDA 31-2531 Technical Data in Class 2 acc. to DIN 24166 Curves PolesVoltage/ Fre- Speed Connection quency max. power Nominal consumption current FDA 31- kW 2531-MD• 2531-6D• 2531-GD 2531-4E• 2531-6E• V Hz 1/min Starting/Full qVmaxLWA8 Capa- Protection/WeightMedia load current at qVmax citor Temp. class temp. A m³/h [B1|B2] 4/4 400, 3~ /Y 501340/1070 0.19/0.13 0.43/0.22 2.6 [B3] 6 400, 3~ Y 50 940 0.13 0.41 1.8 [B4|B5] 4/8 400, 3~ YY/Y 50 1400/ 710 0.23/0.06 0.50/0.18 3.2 [B6] 4 230, 1~501420 0.23 1.2 2.3 [B7] 6 230, 1~ 50 920 0.12 0.54 1.5 dB AT mF 2440/2010 60/55 - 1690 51 - 2530/1270 61/43 - 2550 61 6 1670 50 3 kg °C IP44/F69-20...+60 IP44/F 69 -20...+60 IP44/F 70 -20...+60 IP44/F69-20...+60 IP44/F 69 -20...+60 • (also) stepless speed controllable by tension variation AT All indicated sound values are sound power levels. For more calculations when determining the A-sound pressure level at any distances read the statements on part „Sounds“ in chapter „Description“. 120 LWA8 = 5 0 dB 50 58 [B6] 1500 0.4 m³/h m³/s 0 [B5] FDA 31-2531-6E 46 [B7] 80 48 59 60 40 50 20 0 500 1000 1500 2000 2500 m³/h 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 m³/s qV 0 50 61 psF 0 0 qV 500 1000 0.1 0.3 0.2 1500 0.4 m³/h m³/s Accessories Isolator Motor protection unit Transformer 7 taps Transformer 5-steps Speed regulator Speed regulator Speed regulator Speed controller electronic electronic micro processor electronic FDA 31- ESM ETO ETH EPH ESH EPA 2531-MD• 21-0030-6504-0040-8D10-0010-8D35-0010-8D– 83-0050-8D 2531-6D• 21-0030-3501-0040-8D10-0010-8D35-0010-8D– 83-0050-8D 2531-GD21-0030-65 03-0040-8D6 –––– 2531-4E• 21-0030-22– 10-0018-5E31-0020-5E03-0020-5E83-0060-5E 2531-6E• 21-0030-22– 10-0018-5E31-0020-5E03-0010-5E83-0060-5E 108 0 500 1000 1500 2000 2500 m³/h 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 m³/s qV LWA = 8 50 dB 100 100 psF psF 120 57 150 0 500 1000 0.1 0.2 0.3 Pa 140 dB 200 0 0 qV 39 61 250 FDA 31-2531-4E = 61 43 50 43 A8 [B4] 100 51 psF 60 55 LW 0 57 150 20 1500 2000 m³/h 0.4 0.5 0.6 m³/s LWA = 8 61 dB 59 52 0 500 1000 0 0.1 0.2 0.3 qV [B3] 40 FDA 31-2531-GD 200 60 50 Pa 46 48 [B2] Pa 250 80 100 0 FDA 31-2531-6D 100 [B1] 150 r1=1.15 kg/m³ Pa 140 psF Curves in Class 2 acc. to DIN 24166 LWA = FDA 31-2531-MD 8 60 dB 56 200 55 Pa Roof Extract Fans / FDA / Technical Data FDA 31-2531 410 725 Dimensions in mm, Subject to change. FDA 31-2531-.. M6 Flat roof upstand Upstand silencer ZBU 01-0040-25 [St] 4 kg ø256 Connection plate 378 330 270 6×M6 ø286 115 650 283 1 When using back draught damper ZLK in connection with silencer upstand ZDS a spacer ZKK is required □400 □710 618 ZKE 11-0250 1.4 kg 130 535 150 ZKF 11-0250 0.7 kg Mating flange 6×ø7 ø256 ø286 ø306 150 340 618 M M 10 10 ZBS 09-0040-2 [Al] 5 kg ø12 ø256 ø286 ø306 330 618 M 750 10 Inlet silencer ø256 ø286 ø345 ZLK 21-0250 9 kg 1 Motor drive shutter ø7 6×M6 ø256 ø286 ø306 ZBS 11-0040 [GFK] 11 kg 200 Flanged inlet cone ø286 ZSG 04-0250 0.4 kg Mesh inlet guard 3× ø7 ø256 ø286 ø306 ø422 ZKK 20-0040 [St] 11 kg 1 Spacer M10 ø11.5 275 10 □319 ø7 70 ZKD 01-0250 2 kg □330 M Soaker sheet WDS 207 ø88 ZDR 30-0250 12 kg 150 6×ø7 180 Automatic shutter 175 150 ZLK 01-0250 6 kg 1 240 □378 □330 25 10 6×ø7 ø256 ø286 ø306 □618 Inclined roof upstand Inlet connection (flexible) 270 650 6 A protection for high speed is only active if Dahlander bridge is on place 378 330 Inclined roof upstand silencer 115 □378 □330 340 ZDS 09-0040-2 [Al] 13 kg 1 M Flat roof upstand tall M ZBS 23-0040 [St] 10 kg 10 618 250 Pressure loss at back draught damper 138 ZDS 01-0040 [Al] 13 kg ZDS 20-0040 [St] 18 kg 1 Accessories / Index 2 inclination in 5° steps up to 45° possible 6 ZBS 01-0040 [Al] 4 kg ZBS 20-0040 [St] 8 kg □395 □330 Mains lead 138 a- Nicotra Gebhardt external rotor motor with impeller fitted directly. Casing equipped with sound absorbing lining. 1600 Accessories FDA 31- ø12 115 M6 440 626 28 32 330 6× 330 386 920 109 Roof Extract Fans / FDA / Technical Data FDA 31-3535 Technical Data in Class 2 acc. to DIN 24166 Curves PolesVoltage/ Fre- Speed Connection quency max. power Nominal consumption current FDA 31- V 1/min kW A m³/h dB AT mF kg °C 3535-MD• 3535-ND• 3535-GD 3535-4E• 3535-6E• 400, 3~ /Y50 400, 3~ /Y 50 400, 3~ YY/Y 50 230, 1~ 50 230, 1~ 50 1340/1080 940/ 820 1280/ 670 1340 930 0.35/0.22 0.17/0.09 0.33/0.06 0.40 0.15 0.75/0.39 2.7 0.50/0.18 2.2 0.56/0.15 2.3 1.9 1.8 0.72 1.7 3470/2910 2400/2160 3340/1730 3470 2380 66/61 56/53 65/48 66 56 - - - 8 4 110 110 111 110 110 -20...+60 -20...+60 -20...+60 -20...+60 -20...+60 [C1|C2] 4/4 [C3|C4] 6/6 [C5|C6] 4/8 [C7] 4 [C8] 6 Hz Starting/Full qVmaxLWA8 Capa- Protection/WeightMedia load current at qVmax citor Temp. class temp. IP44/F IP44/F IP54/F IP44/F IP44/F • (also) stepless speed controllable by tension variation AT All indicated sound values are sound power levels. For more calculations when determining the A-sound pressure level at any distances read the statements on part „Sounds“ in chapter „Description“. r1=1.15 kg/m³ Pa 150 125 psF psF psF 100 45 41 [C6] 0 0 0 qV 1000 2000 0.4 0.6 0.2 4 dB 50 [C8] 53 50 1000 2000 0.4 0.6 0.2 3000 0.8 25 m³/h m³/s 0 56 66 0 0 qV psF 50 psF 150 =5 75 100 [C5] 0 500 1000 1500 2000 2500 m³/h 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 m³/s qV Accessories Isolator Motor protection unit Transformer 7 taps Transformer 5-steps Speed regulator Speed regulator Speed regulator Speed controller electronic electronic micro processor electronic FDA 31- ESM ETO ETH EPH ESH EPA 3535-MD• 21-0030-6504-0040-8D10-0010-8D35-0010-8D– 83-0050-8D 3535-ND• 21-0030-6504-0040-8D10-0010-8D35-0010-8D– 83-0050-8D 3535-GD21-0030-65 03-0040-8D6 –––– 3535-4E• 21-0030-22– 10-0040-5E31-0020-5E03-0020-5E83-0060-5E 3535-6E• 21-0030-22– 10-0018-5E31-0020-5E03-0010-5E83-0060-5E 110 65 A8 100 63 150 58 200 0 500 1000 1500 2000 2500 m³/h 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 m³/s qV 125 [C7] B FDA 31-3535-6E 150 59 2d 62 3 dB =6 50 175 L W 200 0 [C4] Pa =6 250 0 A8 48 300 [C3] 56 53 A8 47 LW 250 25 m³/h m³/s FDA 31-3535-4E 350 LW 50 50 FDA 31-3535-GD 300 53 Pa 3000 0.8 66 61 1000 2000 0.4 0.6 0.2 51 Pa 350 dB 75 63 0 0 qV = 54 A8 50 50 0 LW 100 58 100 FDA 31-3535-ND 175 59 Curves in Class 2 acc. to DIN 24166 Pa FDA 31-3535-MD 350 LWA 8 =6 3 dB 300 59 250 [C1] 200 54 150 [C2] 3000 0.8 m³/h m³/s Roof Extract Fans / FDA / Technical Data FDA 31-3535 600 786 M8 216 ZDS 01-0056 [Al] 29 kg ZDS 20-0056 [St] 40 kg 1 Flat roof upstand Upstand silencer □555 □450 Mains lead ZBU 01-0056-35 [St] 6 kg 538 450 ø361 Connection plate 430 □560 □870 8×M8 ø395 115 800 283 1 When using back draught damper ZLK in connection with silencer upstand ZDS a spacer ZKK is required 778 ZKE 11-0355 2.1 kg 130 685 150 ZKF 11-0355 0.9 kg Mating flange 8×ø9.5 ø361 ø395 ø421 150 500 778 M M 10 10 ZBS 09-0056-2 [Al] 6 kg 250 ø361 ø395 ø421 450 ø12 778 M 750 10 Inlet silencer ø361 ø395 ø500 ZLK 21-0355 11 kg 1 Motor drive shutter 8×M8 ø361 ø395 ø421 ZBS 11-0056 [GFK] 12 kg 200 Flanged inlet cone ø395 ZSG 04-0355 0.6 kg Mesh inlet guard 4× ø9.5 ø361 ø395 ø421 ø515 ZKK 20-0056 [St] 14 kg 1 Spacer M10 ø11.5 275 10 □420 ø9.5 63 ZKD 01-0355 3.5 kg □450 M Soaker sheet WDS 258 ø9.5 ø88 ZDR 30-0355 17 kg 150 8×ø9.5 236 Automatic shutter 205 150 ZLK 01-0355 7 kg 1 240 □538 □450 30 10 8×ø9.5 ø361 ø395 ø421 □778 Inclined roof upstand Inlet connection (flexible) 430 800 6 A protection for high speed is only active if Dahlander bridge is on place 538 450 Inclined roof upstand silencer 115 □538 □450 500 ZDS 09-0056-2 [Al] 29 kg 1 M Flat roof upstand tall M ZBS 23-0056 [St] 14 kg 10 778 a- Pressure loss at back draught damper 192 ZBS 01-0056 [Al] 5 kg ZBS 20-0056 [St] 10 kg Accessories / Index 2 inclination in 5° steps up to 45° possible 39 ø12 1600 Nicotra Gebhardt external rotor motor with impeller fitted directly. Casing equipped with sound absorbing lining. 5 450 32 M8 600 836 Accessories FDA 31- 8× 115 Dimensions in mm, Subject to change. FDA 31-3535-.. 450 546 920 111 Roof Extract Fans / FDA / Technical Data FDA 31-3540 Technical Data in Class 2 acc. to DIN 24166 Curves PolesVoltage/ Fre- Speed Connection quency max. power Nominal consumption current FDA 31- kW A m³/h dB AT 0.58/0.44 0.22/0.13 0.62/0.12 0.52 0.20 1.35/0.74 3.4 0.55/0.23 2.0 1.20/0.38 3.7 2.3 1.8 0.91 1.7 4830/4250 3100/2520 4780/2520 4340 3100 69/66 - IP44/F 115 -20...+60 58/52 - IP44/F 112 -20...+60 69/52 - IP54/F 117 -20...+60 6612IP44/F115 -20...+55 58 5 IP44/F 112 -20...+60 3540-MD• 3540-ND• 3540-GD 3540-4E• 3540-6E• V Hz 1/min [D1|D2]4/4 400, 3~ /Y50 1400/1190 [D3|D4]6/6 400, 3~ /Y 50 890/ 690 [D5|D6]4/8 400, 3~ YY/Y 50 1380/ 700 [D7] 4 230, 1~501220 [D8] 6 230, 1~ 50 890 Starting/Full qVmaxLWA8 Capa- Protection/WeightMedia load current at qVmax citor Temp. class temp. mF kg °C • (also) stepless speed controllable by tension variation AT All indicated sound values are sound power levels. For more calculations when determining the A-sound pressure level at any distances read the statements on part „Sounds“ in chapter „Description“. 150 [D1] 59 =5 6 dB A8 54 [D4] 100 1000 2000 0.2 0.4 0.6 LW psF psF Pa A8 B 0 52 0 1000 2000 0.2 0.4 0.6 0 qV 3000 4000 m³/h 0.8 1.0 1.2 m³/s FDA 31-3540-6E =5 6 dB 150 59 m³/h m³/s [D6] 51 300 3000 0.8 45 69 5d 0 0 qV 58 FDA 31-3540-4E 52 350 =6 [D5] 50 48 A8 0 62 65 45 66 LW Pa 3000 4000 m³/h 0.8 1.0 1.2 m³/s dB 200 69 0 1000 2000 0.2 0.4 0.6 0 qV = 67 [D3] 63 0 LW FDA 31-3540-GD 300 50 100 Pa 400 50 100 66 [D2] 200 A8 FDA 31-3540-ND 51 300 r1=1.15 kg/m³ LW Pa psF Curves in Class 2 acc. to DIN 24166 Pa FDA 31-3540-MD LW A8 = 6 8 dB 400 6 63 4 250 [D7] 200 64 54 150 50 0 1000 2000 0.2 0.4 0.6 0 qV 3000 4000 m³/h 0.8 1.0 1.2 m³/s 0 58 66 psF 50 psF 100 0 [D8] 100 0 0 qV 1000 2000 0.4 0.6 0.2 3000 0.8 m³/h m³/s Accessories Isolator Motor protection unit Transformer 7 taps Transformer 5-steps Speed regulator Speed regulator Speed regulator Speed controller electronic electronic micro processor electronic FDA 31- ESM ETO ETH EPH ESH EPA 3540-MD• 21-0030-6504-0040-8D10-0020-8D35-0020-8D– 83-0050-8D 3540-ND• 21-0030-6504-0040-8D10-0010-8D35-0010-8D– 83-0050-8D 3540-GD21-0030-65 03-0040-8D6 –––– 3540-4E• 21-0030-2501-0020-5E10-0040-5E35-0040-5E03-0040-5E83-0060-5E 3540-6E• 21-0030-22– 10-0018-5E31-0020-5E03-0010-5E83-0060-5E 112 Roof Extract Fans / FDA / Technical Data FDA 31-3540 600 810 M8 216 ZDS 01-0056 [Al] 29 kg ZDS 20-0056 [St] 40 kg 1 Flat roof upstand Upstand silencer □555 □450 Mains lead ZBU 01-0056-35 [St] 6 kg 538 450 ø361 Connection plate 430 □560 □870 8×M8 ø395 115 800 283 1 When using back draught damper ZLK in connection with silencer upstand ZDS a spacer ZKK is required 778 ZKE 11-0355 2.1 kg 130 685 150 ZKF 11-0355 0.9 kg Mating flange 8×ø9.5 ø361 ø395 ø421 150 500 778 M M 10 10 ZBS 09-0056-2 [Al] 6 kg 250 ø361 ø395 ø421 450 ø12 778 M 750 10 Inlet silencer ø361 ø395 ø500 ZLK 21-0355 11 kg 1 Motor drive shutter 8×M8 ø361 ø395 ø421 ZBS 11-0056 [GFK] 12 kg 200 Flanged inlet cone ø395 ZSG 04-0355 0.6 kg Mesh inlet guard 4× ø9.5 ø361 ø395 ø421 ø515 ZKK 20-0056 [St] 14 kg 1 Spacer M10 ø11.5 275 10 □420 ø9.5 63 ZKD 01-0355 3.5 kg □450 M Soaker sheet WDS 258 ø9.5 ø88 ZDR 30-0355 17 kg 150 8×ø9.5 236 Automatic shutter 205 150 ZLK 01-0355 7 kg 1 240 □538 □450 30 10 8×ø9.5 ø361 ø395 ø421 □778 Inclined roof upstand Inlet connection (flexible) 430 800 6 A protection for high speed is only active if Dahlander bridge is on place 538 450 Inclined roof upstand silencer 115 □538 □450 500 ZDS 09-0056-2 [Al] 29 kg 1 M Flat roof upstand tall M ZBS 23-0056 [St] 14 kg 10 778 a- Pressure loss at back draught damper 192 ZBS 01-0056 [Al] 5 kg ZBS 20-0056 [St] 10 kg Accessories / Index 2 inclination in 5° steps up to 45° possible 39 ø12 1600 Nicotra Gebhardt external rotor motor with impeller fitted directly. Casing equipped with sound absorbing lining. 5 450 32 M8 600 836 Accessories FDA 31- 8× 115 Dimensions in mm, Subject to change. FDA 31-3540-.. 450 546 920 113 Roof Extract Fans / FDA / Technical Data FDA 31-3545 Technical Data in Class 2 acc. to DIN 24166 Curves PolesVoltage/ Fre- Speed Connection quency max. power Nominal consumption current FDA 31- kW A m³/h dB AT 0.95/0.76 0.30/0.17 1.00/0.15 0.95 0.31 2.30/1.30 4.1 0.67/0.32 2.2 2.00/0.54 3.9 4.4 2.1 1.4 1.4 6800/6130 4190/3060 6650/3320 6450 4150 72/69 - IP44/F 119 -20...+60 59/51 - IP44/F 119 -20...+60 72/54 - IP54/F 124 -20...+60 7120IP44/F119 -20...+55 59 8 IP44/F 119 -20...+60 3545-MD• 3545-ND• 3545-GD 3545-4E• 3545-6E• V Hz 1/min [E1|E2] 4/4 400, 3~ /Y50 1420/1250 [E3|E4] 6/6 400, 3~ /Y 50 860/ 600 [E5|E6] 4/8 400, 3~ YY/Y 50 1380/ 690 [E7] 4 230, 1~501330 [E8] 6 230, 1~ 50 850 Starting/Full qVmaxLWA8 Capa- Protection/WeightMedia load current at qVmax citor Temp. class temp. mF kg °C • (also) stepless speed controllable by tension variation AT All indicated sound values are sound power levels. For more calculations when determining the A-sound pressure level at any distances read the statements on part „Sounds“ in chapter „Description“. r1=1.15 kg/m³ Pa A8 63 300 [E1] B 54 50 =7 psF Pa B LW A8 65 3000 4000 m³/h 1.0 m³/s 100 0 53 48 [E6] 54 0 1000 2000 3000 4000 5000 0.5 0 1.0 1.5 qV FDA 31-3545-6E 250 0d 400 2000 0.5 [E5] 200 =5 9d B 54 [E7] 300 150 [E8] 68 200 0 1000 2000 3000 4000 5000 0.5 0 1.0 1.5 qV psF m³/h m³/s 0 59 0 50 71 psF 100 56 100 0 0 qV 1000 2000 0.5 3000 4000 m³/h 1.0 m³/s Accessories Isolator Motor protection unit Transformer 7 taps Transformer 5-steps Speed regulator Speed regulator Speed regulator Speed controller electronic electronic micro processor electronic FDA 31- ESM ETO ETH EPH ESH EPA 3545-MD• 21-0030-6504-0040-8D10-0040-8D36-0040-8D– 83-0050-8D 3545-ND• 21-0030-6504-0040-8D10-0010-8D35-0010-8D– 83-0050-8D 3545-GD21-0030-65 03-0040-8D6 –––– 3545-4E• 21-0030-2501-0020-5E10-0070-5E35-0070-5E– 83-0060-5E 3545-6E• 21-0030-22– 10-0018-5E31-0020-5E03-0020-5E83-0060-5E 114 72 500 FDA 31-3545-4E 1000 59 A8 200 [E4] 48 0 0 qV 66 69 45 51 LW 0 1 dB 300 [E3] 40 m³/h m³/s =7 400 56 72 69 0 1000 2000 3000 4000 5000 0.5 0 1.0 1.5 qV A8 FDA 31-3545-GD 9d 66 psF =5 120 LW 500 80 100 Pa 160 69 [E2] 200 0 200 Pa psF 400 FDA 31-3545-ND 240 LW 69 Curves in Class 2 acc. to DIN 24166 Pa LW FDA 31-3545-MD A8 = 71 d B 500 67 m³/h m³/s Roof Extract Fans / FDA / Technical Data FDA 31-3545 600 853 M8 216 ZDS 01-0056 [Al] 29 kg ZDS 20-0056 [St] 40 kg 1 Flat roof upstand Upstand silencer □555 □450 Mains lead ZBU 01-0056-35 [St] 6 kg 538 450 ø361 Connection plate 430 □560 □870 8×M8 ø395 115 800 283 1 When using back draught damper ZLK in connection with silencer upstand ZDS a spacer ZKK is required 778 ZKE 11-0355 2.1 kg 130 685 150 ZKF 11-0355 0.9 kg Mating flange 8×ø9.5 ø361 ø395 ø421 150 500 778 M M 10 10 ZBS 09-0056-2 [Al] 6 kg 250 ø361 ø395 ø421 450 ø12 778 M 750 10 Inlet silencer ø361 ø395 ø500 ZLK 21-0355 11 kg 1 Motor drive shutter 8×M8 ø361 ø395 ø421 ZBS 11-0056 [GFK] 12 kg 200 Flanged inlet cone ø395 ZSG 04-0355 0.6 kg Mesh inlet guard 4× ø9.5 ø361 ø395 ø421 ø515 ZKK 20-0056 [St] 14 kg 1 Spacer M10 ø11.5 275 10 □420 ø9.5 63 ZKD 01-0355 3.5 kg □450 M Soaker sheet WDS 258 ø9.5 ø88 ZDR 30-0355 17 kg 150 8×ø9.5 236 Automatic shutter 205 150 ZLK 01-0355 7 kg 1 240 □538 □450 30 10 8×ø9.5 ø361 ø395 ø421 □778 Inclined roof upstand Inlet connection (flexible) 430 800 6 A protection for high speed is only active if Dahlander bridge is on place 538 450 Inclined roof upstand silencer 115 □538 □450 500 ZDS 09-0056-2 [Al] 29 kg 1 M Flat roof upstand tall M ZBS 23-0056 [St] 14 kg 10 778 a- Pressure loss at back draught damper 192 ZBS 01-0056 [Al] 5 kg ZBS 20-0056 [St] 10 kg Accessories / Index 2 inclination in 5° steps up to 45° possible 39 ø12 1600 Nicotra Gebhardt external rotor motor with impeller fitted directly. Casing equipped with sound absorbing lining. 5 450 32 M8 600 836 Accessories FDA 31- 8× 115 Dimensions in mm, Subject to change. FDA 31-3545-.. 450 546 920 115 Roof Extract Fans / FDA / Technical Data FDA 31-4550 Technical Data in Class 2 acc. to DIN 24166 Curves PolesVoltage/ Fre- Speed Connection quency max. power Nominal consumption current FDA 31- kW A m³/h dB AT 1.60/1.05 0.52/0.38 0.28 1.62/0.25 1.45 0.54 3.20/1.80 3.8 1.30/0.69 3.3 0.69 2.3 2.90/0.77 3.3 6.3 2.0 2.6 1.8 9150/7740 6250/5430 4500 8960/4530 8660 6100 74/69 - IP44/F 193 -20...+60 64/60 - IP44/F 184 -20...+60 56 - IP54/F 183 -20...+55 74/56 - IP54/F 199 -20...+50 7330IP44/F192 -20...+60 64 12 IP44/F 184 -20...+45 4550-MD• 4550-ND• 4550-8D• 4550-GD 4550-4E• 4550-6E• V Hz 1/min [F1|F2] 4/4 400, 3~ /Y50 1350/1100 [F3|F4] 6/6 400, 3~ /Y 50 930/ 780 [F5] 8 400, 3~ 50 660 [F6|F7] 4/8 400, 3~ YY/Y 50 1320/ 670 [F8] 4 230, 1~501260 [F9] 6 230, 1~ 50 900 Starting/Full qVmaxLWA8 Capa- Protection/WeightMedia load current at qVmax citor Temp. class temp. mF kg °C • (also) stepless speed controllable by tension variation AT All indicated sound values are sound power levels. For more calculations when determining the A-sound pressure level at any distances read the statements on part „Sounds“ in chapter „Description“. 1d B 200 69 psF LW A8 =6 2 dB 57 [F9] 0 0 qV 2000 0.5 4000 6000 8000 m³/h 1.0 1.5 m³/s 2.0 50 0 0 1000 2000 3000 4000 5000 6000 0.5 0 1.0 1.5 qV psF Accessories Isolator Motor protection unit Transformer 7 taps Transformer 5-steps Speed regulator Speed regulator Speed regulator Speed controller electronic electronic micro processor electronic FDA 31- ESM ETO ETH EPH ESH EPA 4550-MD• 21-0030-6504-0040-8D10-0040-8D36-0040-8D– 83-0050-8D 4550-ND• 21-0030-6504-0040-8D10-0020-8D35-0020-8D– 83-0050-8D 4550-8D21-0030-3501-0040-8D10-0010-8D35-0010-8D– 83-0050-8D 4550-GD21-0030-65 03-0040-8D6 –––– 4550-4E• 21-0030-2501-0020-5E10-0070-5E35-0070-5E– 83-0100-5E 4550-6E• 21-0030-2501-0020-5E10-0040-5E31-0040-5E03-0040-5E83-0060-5E 116 4000 m³/h 1.0 m³/s 64 73 4000 6000 8000 m³/h 1.0 1.5 m³/s 2.0 0 3000 100 100 74 2000 0.5 [F7] 56 2000 0.5 60 100 0 0 qV 150 200 49 1000 FDA 31-4550-6E 250 [F8] 70 200 54 0 0 qV Pa 300 66 300 300 psF m³/h m³/s 0 350 400 [F6] 6000 1.5 FDA 31-4550-4E =7 500 67 4000 1.0 psF B 400 psF psF 2d 2000 0.5 56 600 500 0 0 0 qV [F5] 50 50 A8 B 100 [F3] [F4] LW 4d 49 54 Pa =5 58 200 0 FDA 31-4550-8D 49 =7 150 64 A A8 3 dB 60 FDA 31-4550-GD 600 250 4000 6000 8000 m³/h 1.0 1.5 m³/s 2.0 Pa 700 LW 300 LW =6 57 2000 0.5 74 69 0 0 qV A8 100 100 0 350 L W Pa 61 68 200 FDA 31-4550-ND 150 71 [F2] 300 r1=1.15 kg/m³ Pa 59 68 Curves in Class 2 acc. to DIN 24166 Pa FDA 31-4550-MD 700 LWA8 = 73 dB 600 68 500 [F1] 400 63 m³/h m³/s Roof Extract Fans / FDA / Technical Data FDA 31-4550 740 1053 M8 M8 750 1016 Flat roof upstand Upstand silencer ZBU 01-0071-45 [St] 10 kg ø453 Connection plate 688 590 580 6×M8 ø487 115 900 283 1 When using back draught damper ZLK in connection with silencer upstand ZDS a spacer ZKK is required □710 □1020 988 ZKE 11-0450 2.7 kg 130 6×ø9.5 ZKF 11-0450 1.2 kg Mating flange 6×ø9.5 ø453 ø487 ø513 150 650 988 M M 12 12 ZBS 09-0071-2 [Al] 9 kg ø14 ø453 ø487 ø513 590 988 M 12 1000 Inlet silencer ø453 ø487 ø650 ZLK 21-0450 14 kg 1 Motor drive shutter 6×M8 ø453 ø487 ø513 ZBS 11-0071 [GFK] 29 kg 200 Flanged inlet cone ø487 ZSG 04-0450 0.7 kg Mesh inlet guard 3× ø9.5 ø453 ø487 ø513 ø640 ZKK 20-0071 [St] 16 kg 1 Spacer M12 ø14 275 12 □560 ø9.5 120 ZKD 01-0450 5 kg □590 M Soaker sheet WDS 300 ø9.5 ø88 282 ZDR 30-0450 22 kg 150 6×ø9.5 278 Automatic shutter 175 150 ZLK 01-0450 10 kg 1 240 □688 □590 30 150 785 ø453 ø487 ø513 □988 Inclined roof upstand Inlet connection (flexible) 580 900 6 A protection for high speed is only active if Dahlander bridge is on place 650 688 590 Inclined roof upstand silencer 115 □688 □590 12 ZDS 09-0071-2 [Al] 57 kg 1 M Flat roof upstand tall M ZBS 23-0071 [St] 20 kg 12 988 250 Pressure loss at back draught damper 282 ZDS 01-0071 [Al] 57 kg ZDS 20-0071 [St] 79 kg 1 Accessories / Index 2 inclination in 5° steps up to 45° possible 7 ZBS 01-0071 [Al] 8 kg ZBS 20-0071 [St] 16 kg □705 □590 Mains lead 222 a- Nicotra Gebhardt external rotor motor with impeller fitted directly. Casing equipped with sound absorbing lining. ø14 2000 Accessories FDA 31- 48 32 590 6× 115 Dimensions in mm, Subject to change. FDA 31-4550-.. 590 700 1400 117 Roof Extract Fans / FDA / Technical Data FDA 31-4556 Technical Data in Class 2 acc. to DIN 24166 Curves PolesVoltage/ Fre- Speed Connection quency max. power Nominal consumption current FDA 31- V kW 4556-MD• 4556-ND• 4556-8D• 4556-GD 400, 3~ /Y 50 400, 3~ /Y 50 400, 3~ 50 400, 3~ YY/Y 50 [G1|G2] 4/4 [G3|G4] 6/6 [G5] 8 [G6|G7] 4/8 Hz 1/min 1270/ 960 2.40/1.46 920/ 770 0.90/0.59 610 0.38 1400/ 710 3.00/0.41 Starting/Full qVmaxLWA8 Capa- Protection/WeightMedia load current at qVmax citor Temp. class temp. A m³/h dB AT mF kg °C 4.30/2.4 2.10/1.1 0.93 5.20/1.2 12580/9950 8990/7790 6130 13620/6860 75/69 67/63 56 78/60 - - - - 202 191 202 211 -20...+45 -20...+60 -20...+60 -20...+45 3.4 3.5 1.9 5.0 IP54/F IP44/F IP54/F IP54/F • (also) stepless speed controllable by tension variation AT All indicated sound values are sound power levels. For more calculations when determining the A-sound pressure level at any distances read the statements on part „Sounds“ in chapter „Description“. Curves in Class 2 acc. to DIN 24166 LW Pa FDA 31-4556-MD A8 = 75 700 dB 69 600 LW Pa A8 350 300 = 67 FDA 31-4556-ND LW Pa A8 dB 61 62 150 r1=1.15 kg/m³ = FDA 31-4556-8D 56 dB 68 62 0 0 0 qV 2000 0.5 4000 6000 8000 m³/h 2.0 1.0 m³/s 1.5 0 56 m³/h m³/s 67 psF 50 63 psF 50 0 0 qV 2000 0.5 4000 1.0 FDA 31-4556-GD 72 700 75 69 0 2000 4000 6000 8000 10000 2.0 0 1.0 3.0 qV [G5] 53 LW Pa A8 = 7 7 dB 800 59 66 100 100 0 100 [G4] 150 [G2] 200 [G3] 64 72 300 56 200 psF 400 [G1] 50 250 500 600 [G6] 500 75 400 300 60 54 100 0 [G7] 60 78 psF 200 0 2000 4000 6000 8000 10000 2.0 0q 3.0 V m³/h m³/s Accessories Isolator Motor protection unit Transformer 7 taps Transformer 5-steps Speed regulator Speed regulator Speed regulator Speed controller electronic electronic micro processor electronic FDA 31- ESM ETO ETH EPH ESH EPA 4556-MD• 21-0030-6504-0040-8D10-0065-8D36-0070-8D– 83-0050-8D 4556-ND• 21-0030-6504-0040-8D10-0040-8D36-0040-8D– 83-0050-8D 4556-8D21-0030-3501-0040-8D10-0010-8D35-0010-8D– 83-0050-8D 4556-GD21-0030-65 03-0040-8D6 –––– 118 6000 1.5 m³/h m³/s Roof Extract Fans / FDA / Technical Data FDA 31-4556 740 1096 M8 M8 750 1016 Flat roof upstand Upstand silencer ZBU 01-0071-45 [St] 10 kg ø453 Connection plate 688 590 580 6×M8 ø487 115 900 283 1 When using back draught damper ZLK in connection with silencer upstand ZDS a spacer ZKK is required □710 □1020 988 ZKE 11-0450 2.7 kg 130 6×ø9.5 ZKF 11-0450 1.2 kg Mating flange 6×ø9.5 ø453 ø487 ø513 150 650 988 M M 12 12 ZBS 09-0071-2 [Al] 9 kg ø14 ø453 ø487 ø513 590 988 M 12 1000 Inlet silencer ø453 ø487 ø650 ZLK 21-0450 14 kg 1 Motor drive shutter 6×M8 ø453 ø487 ø513 ZBS 11-0071 [GFK] 29 kg 200 Flanged inlet cone ø487 ZSG 04-0450 0.7 kg Mesh inlet guard 3× ø9.5 ø453 ø487 ø513 ø640 ZKK 20-0071 [St] 16 kg 1 Spacer M12 ø14 275 12 □560 ø9.5 120 ZKD 01-0450 5 kg □590 M Soaker sheet WDS 300 ø9.5 ø88 282 ZDR 30-0450 22 kg 150 6×ø9.5 278 Automatic shutter 175 150 ZLK 01-0450 10 kg 1 240 □688 □590 30 150 785 ø453 ø487 ø513 □988 Inclined roof upstand Inlet connection (flexible) 580 900 6 A protection for high speed is only active if Dahlander bridge is on place 650 688 590 Inclined roof upstand silencer 115 □688 □590 12 ZDS 09-0071-2 [Al] 57 kg 1 M Flat roof upstand tall M ZBS 23-0071 [St] 20 kg 12 988 250 Pressure loss at back draught damper 282 ZDS 01-0071 [Al] 57 kg ZDS 20-0071 [St] 79 kg 1 Accessories / Index 2 inclination in 5° steps up to 45° possible 7 ZBS 01-0071 [Al] 8 kg ZBS 20-0071 [St] 16 kg □705 □590 Mains lead 222 a- Nicotra Gebhardt external rotor motor with impeller fitted directly. Casing equipped with sound absorbing lining. ø14 2000 Accessories FDA 31- 48 32 590 6× 115 Dimensions in mm, Subject to change. FDA 31-4556-.. 590 700 1400 119 Roof Extract Fans / FDA / Technical Data FDA 31-5663 Technical Data in Class 2 acc. to DIN 24166 Curves PolesVoltage/ Fre- Speed Connection quency max. power Nominal consumption current FDA 31- 1/min kW 900/700 700 920/470 1.30/0.88 2.9/1.7 2.6 0.76 1.8 2.8 1.73/0.29 3.1/0.93 3.9 V Hz 5663-ND• [H1|H2]6/6 400, 3~ /Y50 5663-8D• [H3] 8 400, 3~ 50 5663-HD [H4|H5]6/12 400, 3~ YY/Y 50 Starting/Full qVmaxLWA8 Capa- Protection/WeightMedia load current at qVmax citor Temp. class temp. A m³/h mF dB AT 12500/1030070/65 - 9630 64 - 12750/ 6450 71/53 - IP44/F IP54/F IP54/F kg °C 277 279 294 -20...+60 -20...+55 -20...+55 • (also) stepless speed controllable by tension variation AT All indicated sound values are sound power levels. For more calculations when determining the A-sound pressure level at any distances read the statements on part „Sounds“ in chapter „Description“. Curves in Class 2 acc. to DIN 24166 Pa FDA 31-5663-ND LW A8 = 7 0 dB 400 dB = 70 dB 300 [H4] 100 [H5] 0 0 qV 2000 0.5 4000 6000 8000 m³/h 2.0 1.0 m³/s 1.5 psF 0 0 2000 4000 6000 8000 10000 2.0 0 1.0 3.0 qV Accessories Isolator Motor protection unit Transformer 7 taps Transformer 5-steps Speed regulator Speed regulator Speed regulator Speed controller electronic electronic micro processor electronic FDA 31- ESM ETO ETH EPH ESH EPA 5663-ND• 21-0030-6504-0040-8D10-0040-8D36-0040-8D– 83-0050-8D 5663-8D• 21-0030-3501-0040-8D10-0020-8D35-0020-8D– 83-0050-8D 5663-HD21-0030-65 03-0040-8D6 –––– 120 71 psF 48 53 70 65 m³/h m³/s 0 53 64 50 68 200 100 0 2000 4000 6000 8000 10000 2.0 0 1.0 3.0 qV A8 FDA 31-5663-HD 65 58 61 [H2] LW 150 67 59 Pa 400 61 psF = 63 [H3] [H1] 100 0 A8 FDA 31-5663-8D 200 300 200 LW 250 65 63 r1=1.15 kg/m³ Pa m³/h m³/s Roof Extract Fans / FDA / Technical Data FDA 31-5663 990 1109 ZDS 01-0090 [Al] 76 kg ZDS 20-0090 [St] 105 kg 1 Flat roof upstand Upstand silencer □895 □750 335 ZBU 01-0090-56 [St] 17 kg ø569 Connection plate 878 750 770 8×M10 ø605 115 900 283 1 When using back draught damper ZLK in connection with silencer upstand ZDS a spacer ZKK is required □900 □1210 1178 ZKE 11-0560 3.6 kg 130 785 150 ZKF 11-0560 1.5 kg Mating flange 8×ø11.5 ø569 ø605 ø639 150 840 1178 M M 12 12 ZBS 09-0090-2 [Al] 13 kg 250 ø569 ø605 ø639 750 ø14 1178 M 12 1000 Inlet silencer ø569 ø605 ø770 ZLK 21-0560 16 kg 1 Motor drive shutter 8×M10 ø569 ø605 ø639 ZBS 11-0090 [GFK] 36 kg 200 Flanged inlet cone □720 ZSG 04-0560 0.8 kg Mesh inlet guard 4× ø11.5 ø569 ø605 ø639 ø785 ZKK 20-0090 [St] 19 kg 1 M12 ø14 275 Spacer 12 ø11.5 ø605 78 ZKD 01-0560 7.5 kg □750 M Soaker sheet WDS 360 ø11.5 ø88 343 ZDR 30-0560 50 kg 150 8×ø11.5 343 Automatic shutter 240 150 ZLK 01-0560 13 kg 1 240 □878 □750 35 12 8×ø11.5 ø569 ø605 ø639 □1178 Inclined roof upstand Inlet connection (flexible) 770 900 6 A protection for high speed is only active if Dahlander bridge is on place 878 750 Inclined roof upstand silencer 115 □878 □750 840 ZDS 09-0090-2 [Al] 76 kg 1 M Flat roof upstand tall M ZBS 23-0090 [St] 32 kg 12 1178 a- Pressure loss at back draught damper Mains lead 317 ZBS 01-0090 [Al] 13 kg ZBS 20-0090 [St] 25 kg Accessories / Index 2 inclination in 5° steps up to 45° possible 60 ø14 2000 Nicotra Gebhardt external rotor motor with impeller fitted directly. Casing equipped with sound absorbing lining. 5 750 40 M10 940 1256 Accessories FDA 31- 0 M1 8× 115 Dimensions in mm, Subject to change. FDA 31-5663-.. 750 886 1400 121 Roof Extract Fans / FDA / Technical Data FDA 31-5671 Technical Data in Class 2 acc. to DIN 24166 Curves PolesVoltage/ Fre- Speed Connection quency max. power Nominal consumption current FDA 31- kW V Hz 1/min Starting/Full qVmaxLWA8 Capa- Protection/WeightMedia load current at qVmax citor Temp. class temp. A m³/h mF dB AT kg °C 5671-ND• [J1|J2] 6/6 400, 3~ /Y50 880/680 2.5/1.5 5.0/2.8 3.6 16850/1364074/68 - IP54/F 297 -20...+45 5671-8D• [J3] 8 400, 3~ 50 6501.22.7 2.61255066 - IP54/F 291 -20...+55 5671-HD [J4|J5] 6/12 400, 3~ YY/Y 50 880/440 2.6/0.39 4.9/1.5 3.4 16850/ 8430 74/56 - IP54/F 302 -20...+50 • (also) stepless speed controllable by tension variation AT All indicated sound values are sound power levels. For more calculations when determining the A-sound pressure level at any distances read the statements on part „Sounds“ in chapter „Description“. Curves in Class 2 acc. to DIN 24166 LW Pa FDA 31-5671-ND A8 = 73 d B 500 300 69 [J4] 300 200 0 2000 4000 6000 8000 10000 2.0 0 1.0 3.0 qV m³/h m³/s 55 100 psF psF 0 3 dB 0 50 [J5] 56 0 0 qV 4000 1.0 8000 2.0 74 psF [J3] 50 m³/h m³/s =7 71 12000 3.0 4.0 FDA 31-5671-HD 400 62 66 8000 2.0 74 68 4000 1.0 A8 B 63 0 0 qV LW 100 65 0 6d 150 71 [J2] 100 =6 Pa 500 200 63 200 A8 250 [J1] 300 FDA 31-5671-8D 350 L W 69 67 400 r1=1.15 kg/m³ Pa 12000 3.0 4.0 Accessories Isolator Motor protection unit Transformer 7 taps Transformer 5-steps Speed regulator Speed regulator Speed regulator Speed controller electronic electronic micro processor electronic FDA 31- ESM ETO ETH EPH ESH EPA 5671-ND• 21-0030-6504-0040-8D10-0065-8D36-0070-8D– 83-0050-8D 5671-8D• 21-0030-3501-0040-8D10-0040-8D36-0040-8D– 83-0050-8D 5671-HD21-0030-65 03-0040-8D6 –––– 122 m³/h m³/s Roof Extract Fans / FDA / Technical Data FDA 31-5671 990 1158 ZDS 01-0090 [Al] 76 kg ZDS 20-0090 [St] 105 kg 1 Flat roof upstand Upstand silencer □895 □750 335 ZBU 01-0090-56 [St] 17 kg ø569 Connection plate 878 750 770 8×M10 ø605 115 900 283 1 When using back draught damper ZLK in connection with silencer upstand ZDS a spacer ZKK is required □900 □1210 1178 ZKE 11-0560 3.6 kg 130 785 150 ZKF 11-0560 1.5 kg Mating flange 8×ø11.5 ø569 ø605 ø639 150 840 1178 M M 12 12 ZBS 09-0090-2 [Al] 13 kg 250 ø569 ø605 ø639 750 ø14 1178 M 12 1000 Inlet silencer ø569 ø605 ø770 ZLK 21-0560 16 kg 1 Motor drive shutter 8×M10 ø569 ø605 ø639 ZBS 11-0090 [GFK] 36 kg 200 Flanged inlet cone □720 ZSG 04-0560 0.8 kg Mesh inlet guard 4× ø11.5 ø569 ø605 ø639 ø785 ZKK 20-0090 [St] 19 kg 1 M12 ø14 275 Spacer 12 ø11.5 ø605 78 ZKD 01-0560 7.5 kg □750 M Soaker sheet WDS 360 ø11.5 ø88 343 ZDR 30-0560 50 kg 150 8×ø11.5 343 Automatic shutter 240 150 ZLK 01-0560 13 kg 1 240 □878 □750 35 12 8×ø11.5 ø569 ø605 ø639 □1178 Inclined roof upstand Inlet connection (flexible) 770 900 6 A protection for high speed is only active if Dahlander bridge is on place 878 750 Inclined roof upstand silencer 115 □878 □750 840 ZDS 09-0090-2 [Al] 76 kg 1 M Flat roof upstand tall M ZBS 23-0090 [St] 32 kg 12 1178 a- Pressure loss at back draught damper Mains lead 317 ZBS 01-0090 [Al] 13 kg ZBS 20-0090 [St] 25 kg Accessories / Index 2 inclination in 5° steps up to 45° possible 60 ø14 2000 Nicotra Gebhardt external rotor motor with impeller fitted directly. Casing equipped with sound absorbing lining. 5 750 40 M10 940 1256 Accessories FDA 31- 0 M1 8× 115 Dimensions in mm, Subject to change. FDA 31-5671-.. 750 886 1400 123 Roof Extract Fans / FDA / Technical Data FDA 31-7180 Technical Data in Class 2 acc. to DIN 24166 Curves PolesVoltage/ Fre- Speed Connection quency max. power Nominal consumption current FDA 31- kW V Hz 1/min Starting/Full qVmaxLWA8 Capa- Protection/WeightMedia load current at qVmax citor Temp. class temp. A m³/h dB AT mF kg °C 7180-6D* [L1] 6 400, 3~ 50 9455.210.2 6.22480079 - IP54/F 477 -20...+55 7180-8D• [L2] 8 400, 3~ 50 660 2.0 4.4 3.1 17600 70 - IP54/F 468 -20...+40 7180-HD [L4|L5] 6/12 400, 3~ YY/Y 50 960/4805.5/0.8511.0/3.3 4.5 24800/12470 79/61- IP54/F 477-20...+55 • (also) stepless speed controllable by tension variation * these types do not have variable speed control by tension variation AT All indicated sound values are sound power levels. For more calculations when determining the A-sound pressure level at any distances read the statements on part „Sounds“ in chapter „Description“. Pa A8 = 71 FDA 31-7180-8D dB [L2] 67 0 0 0 qV 5000 10000 2.0 1.0 3.0 15000 4.0 m³/h m³/s psF psF psF 20000 m³/h 5.0 6.0 m³/s 57 [L5] 100 0 79 4.0 [L4] 200 62 70 10000 3.0 75 300 100 79 2.0 0 dB 700 400 0 0 1.0 qV FDA 31-7180-HD 76 200 200 0 LWA8 = 8 500 300 100 Pa 600 300 76 400 r1=1.15 kg/m³ LW 66 Curves in Class 2 acc. to DIN 24166 LWA8 = 8 Pa FDA 31-7180-6D 0 dB 700 75 600 [L1] 500 61 0 0 1.0 qV 2.0 10000 3.0 4.0 Accessories Isolator Motor protection unit Transformer 7 taps Transformer 5-steps Speed regulator Speed regulator Speed regulator Speed controller electronic electronic micro processor electronic FDA 31- ESM ETO ETH EPH ESH EPA 7180-6D* 21-0075-35 ––––– 7180-8D• 21-0030-3501-0040-8D10-0065-8D36-0070-8D– 83-0050-8D 7180-HD 21-0075-65 ––––– 124 20000 m³/h 5.0 6.0 m³/s Roof Extract Fans / FDA / Technical Data FDA 31-7180 1183 1616 ZDS 01-0125 [Al] 130 kg ZDS 20-0125 [St] 180 kg 1 Flat roof upstand Upstand silencer □1205 □1050 445 ZBU 01-0125-71 [St] 36 kg ø715 Connection plate 1226 1050 1117 8×M10 ø751 115 900 283 1 When using back draught damper ZLK in connection with silencer upstand ZDS a spacer ZKK is required □1210 □1520 1500 1190 785 150 ZKF 11-0710 2.5 kg Mating flange 8×ø11.5 ø715 ø751 ø785 150 Automatic shutter ø715 ø751 ø785 1050 1000 M ø715 ø751 ø915 ZLK 21-0710 20 kg 1 Motor drive shutter 437 ø11.5 8×M10 ø715 ø751 ø785 ø88 415 ø14 12 Inlet silencer 300 ZDR 30-0710 75 kg ZKD 01-0710 10 kg Flanged inlet cone ø11.5 ø751 175 150 8×ø11.5 ZSG 04-0710 1.1 kg Mesh inlet guard 4× ø11.5 ø715 ø751 ø785 ø905 ZKK 20-0125 [St] 32 kg 1 Spacer M12 ø14 275 150 ZLK 01-0710 19 kg 1 415 250 □1226 □1050 300 1190 1526 M M 12 12 ZBS 09-0125-2 [Al] 18 kg 35 12 8×ø11.5 ø715 ø751 ø785 □1526 Inclined roof upstand Inlet connection (flexible) 1117 900 6 A protection for high speed is only active if Dahlander bridge is on place 1226 1050 Inclined roof upstand silencer 115 □1226 □1050 130 ZKE 11-0710 5 kg ZDS 09-0125-2 [Al] 130 kg 1 M Flat roof upstand tall M ZBS 23-0125 [St] 40 kg 12 1526 1526 Pressure loss at back draught damper Mains lead 445 ZBS 01-0125 [Al] 17 kg ZBS 20-0125 [St] 34 kg Accessories / Index 2 inclination in 5° steps up to 45° possible 75 ø14 a- Nicotra Gebhardt external rotor motor with impeller fitted directly. Casing equipped with sound absorbing lining. 1 1050 65 M10 1270 1556 Accessories FDA 31- 0 M1 8× 115 Dimensions in mm, Subject to change. FDA 31-7180-.. 1050 1235 125 Roof Extract Fans / FDA / Technical Data FDA 31-7190 Technical Data in Class 2 acc. to DIN 24166 Curves PolesVoltage/ Fre- Speed Connection quency max. power Nominal consumption current FDA 31- V kW 7190-6D* [M1] 400, 3~ 50 9408.816.4 6.13455083 - IP54/F 500 -20...+40 6 Hz 1/min Starting/Full qVmaxLWA8 Capa- Protection/WeightMedia load current at qVmax citor Temp. class temp. A m³/h dB AT mF kg °C • (also) stepless speed controllable by tension variation * these types do not have variable speed control by tension variation AT All indicated sound values are sound power levels. For more calculations when determining the A-sound pressure level at any distances read the statements on part „Sounds“ in chapter „Description“. r1=1.15 kg/m³ Curves in Class 2 acc. to DIN 24166 Pa LWA8 = 8 FDA 31-7190-6D 3 dB 900 78 800 [M1] 700 600 79 500 400 300 psF 83 200 100 0 10000 0 20000 30000 m³/h 0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 m³/s qV Accessories Isolator Motor protection unit Transformer 7 taps Transformer 5-steps Speed regulator Speed regulator Speed regulator Speed controller electronic electronic micro processor electronic FDA 31- ESM ETO ETH EPH ESH EPA 7190-6D* 21-0075-35 ––––– 126 Roof Extract Fans / FDA / Technical Data FDA 31-7190 1183 1668 ZDS 01-0125 [Al] 130 kg ZDS 20-0125 [St] 180 kg 1 Flat roof upstand Upstand silencer □1205 □1050 445 ZBU 01-0125-71 [St] 36 kg ø715 Connection plate 1226 1050 1117 8×M10 ø751 115 900 283 1 When using back draught damper ZLK in connection with silencer upstand ZDS a spacer ZKK is required □1210 □1520 1500 1190 785 150 ZKF 11-0710 2.5 kg Mating flange 8×ø11.5 ø715 ø751 ø785 150 Automatic shutter ø715 ø751 ø785 1050 1000 M ø715 ø751 ø915 ZLK 21-0710 20 kg 1 Motor drive shutter 437 ø11.5 8×M10 ø715 ø751 ø785 ø88 415 ø14 12 Inlet silencer 300 ZDR 30-0710 75 kg ZKD 01-0710 10 kg Flanged inlet cone ø11.5 ø751 175 150 8×ø11.5 ZSG 04-0710 1.1 kg Mesh inlet guard 4× ø11.5 ø715 ø751 ø785 ø905 ZKK 20-0125 [St] 32 kg 1 Spacer M12 ø14 275 150 ZLK 01-0710 19 kg 1 415 250 □1226 □1050 300 1190 1526 M M 12 12 ZBS 09-0125-2 [Al] 18 kg 35 12 8×ø11.5 ø715 ø751 ø785 □1526 Inclined roof upstand Inlet connection (flexible) 1117 900 6 A protection for high speed is only active if Dahlander bridge is on place 1226 1050 Inclined roof upstand silencer 115 □1226 □1050 130 ZKE 11-0710 5 kg ZDS 09-0125-2 [Al] 130 kg 1 M Flat roof upstand tall M ZBS 23-0125 [St] 40 kg 12 1526 1526 Pressure loss at back draught damper Mains lead 445 ZBS 01-0125 [Al] 17 kg ZBS 20-0125 [St] 34 kg Accessories / Index 2 inclination in 5° steps up to 45° possible 75 ø14 a- Nicotra Gebhardt external rotor motor with impeller fitted directly. Casing equipped with sound absorbing lining. 1 1050 65 M10 1270 1556 Accessories FDA 31- 0 M1 8× 115 Dimensions in mm, Subject to change. FDA 31-7190-.. 1050 1235 127 Roof Extract Fans / FDA / Specification FDA 31-2528/-7190 Specifications Nicotra Gebhardt Radial-Roof-Fan Designed for flow medium temperatures ranging from -20 °C up to approx. +40 °C. Cubic casing made of galvanised sheet steel with noise attenuated lining. Base frame of galvanised sheet steel for pedestal mounting, with a broad upstand for pedestal insulation. On the inlet side with connection option for flange in accordance with DIN 24 155-2. Inlet guard on the discharge cross-section. High performance centrifugal impeller with backward-curved blades, mounted on the rotor of an integrated motor. Totally maintenance-free motor with anti-vibration mounting, thermal contacts for complete protection. Fan ready for connection with terminal box attached. Data in Class 2 according to DIN 24 166. Options (at choice) l Standard, casing with noise attenuated lining l single speed (1~ or 3~) l double speed (3~) l speed controllable by tension variation (1~ or 3~) Fan type FDA 31- VolumeqV = . . . . . . . . . . . . . . . .m3/h Pressure increase psF = . . . . . . . . . . . . . . . . Media temperature t = . . . . . . . . . . . . . . . .°C Speed N = . . . . . . . . . . . . . . . .1/min max. power consumption Pe = . . . . . . . . . . . . . . . .kW Nominal current I = . . . . . . . . . . . . . . . .A Voltage/Frequency U/f = . . . . . . . . . . . . . . . .V/Hz Sound power level LWA8 = . . . . . . . . . . . . . . . .dB Weight m = . . . . . . . . . . . . . . . .kg Special fittings (at extra cost) Isolator mounted (ESH 21) Corrosion protection (Powder-Coating RAL 7039) Accessories (at extra cost) Flat roof upstand – Aluminium (ZBS 01) | galvanised sheet steel (ZBS 20) Flat roof upstand tall – galvanised sheet steel (ZBS 23) Inclined roof upstand – Aluminium (ZBS 09) Soaker sheet WDS – GFK (ZBS 11) up to size 5671 Upstand silencer – Aluminium (ZDS 01) | galvanised sheet steel (ZDS 20) Inclined roof upstand silencer – Aluminium (ZDS 09) Inlet silencer (ZDR 30) Flanged inlet cone (ZKD 01) Connection plate (ZBU 01) Inlet connection - flexible (ZKE 11) Mating flange (ZKF 11) Automatic shutter (ZLK 01) Motor drive shutter (ZLK 21) Mesh inlet guard (ZSG 04) Spacer – galvanised sheet steel (ZKK 20) Switches / Regulators / Controllers Assignment see technical data Specification see Accessories Wiring diagrams see online at www.nicotra-gebhardt.com 128 Roof Extract Fans / FDA / Description FDA 31-2528/-7190 Determination of the Octave level For more exact calculations when determining the required attenuation, the sound power level in the octave bands is important. LWfc 3 = LWA + LWrel 3 LWfc 8 = LWA + LWrel 8 The relative sound power levels for inlet and discharge sides, at various duty points, can be read from the corresponding tables. LWA3 = LWA8 + 11 dB Inlet side Relative sound power level for inlet side LWrel3 at octave centre frequencies fm [LWrel3 = LWfc3 - LWA3] FDA 31- Opperation Point 63 125 250 500 1000 2000 4000 8000 Hz 0.3 qVmax 12 13 -1 -6 -11-12-17-31 dB 2528/-2531 0.6 qVmax 9 12 -2 -5 -9 -10 -16 -29 dB qVmax 3 12 -2 -5 -8 -10 -17 -29 dB 0.3 qVmax 13 12 0 -4 -10-15-19-28 dB 3535/-3545 0.6 qVmax 9 12 0 -4 -10 -12 -16 -25 dB qVmax 5 11 1 -3 -10 -12 -19 -22 dB 0.3 qVmax 4550/-4556 0.6 qVmax qVmax 14 9 5 9 8 7 3 3 2 -3 -3 -3 -9 -8 -8 -14 -12 -12 -15 -13 -13 -21 -17 -14 dB dB dB 0.3 qVmax 5663/-5671 0.6 qVmax qVmax 16 14 12 7 7 7 3 3 4 -4 -4 -4 -7 -8 -8 -12 -11 -12 -14 -13 -13 -21 -20 -21 dB dB dB 0.3 qVmax 7180/-7190 0.6 qVmax qVmax 15 13 10 7 7 7 3 3 4 -4 -4 -4 -7 -7 -8 -11 -11 -11 -13 -12 -12 -20 -19 -19 dB dB dB Discharge side Relative sound power level for discharge side LWrel8 at octave centre frequencies fm [LWrel8 = LWfc8 LWA8] FDA 31- Opperation Point 63 125 250 500 1000 2000 4000 8000 Hz 0.3 qVmax 14 10 6 -9 -16-18-19-22 dB 2528/-2531 0.6 qVmax 14 11 5 -9 -14-16-17-20 dB qVmax 9 9 6 -7 -14 -16 -17 -20 dB 0.3 qVmax 14 10 6 -9 -16-18-19-22 dB 3535/-3545 0.6 qVmax 14 11 5 -9 -14-16-17-20 dB qVmax 9 9 6 -7 -14 -16 -17 -20 dB 0.3 qVmax 16 12 5 -9 -17-19-20-23 dB 4550/-4556 0.6 qVmax 12 12 5 -8 -16-18-19-21 dB qVmax 9 11 4 -5 -12-14-15-16 dB 0.3 qVmax 16 13 4 -7 -19-23-27-29 dB 5663/-5671 0.6 qVmax 16 13 4 -7 -14-17-22-27 dB qVmax 13 11 4 -5 -9 -12 -17 -22 dB 0.3 qVmax 16 13 4 -7 -19-23-27-29 dB 7180/-7190 0.6 qVmax 16 13 4 -7 -14-17-22-27 dB qVmax 13 11 4 -5 -9 -12 -17 -22 dB The sound power levels in the octave bands can – in the case of being situated at blade frequency – reach higher values as indicated in the table. 129 Roof Extract Fans / FDA / Description FDA 31-2528/-7190 Flow rate in the case of low voltage Speed controllable fans 100 % Threephase-AC 80 60 Singlephase-AC 40 qV/qVN 20 0 70 80 Singlephase-AC 120 160 Threephase-AC 100 120 200 U 140 U 240 160 280 180 320 200 230 V 360 400 V This diagramme is made for determining the flow rate in the case of low voltage. The flow rate ratio is shown in function of the voltage at the tappings. Example for evaluation of the flow rate at low voltage: Fan Speed transformer, 5-step Secundary voltage FDA 31-4550-4E ETH 35-0070-5E 130 Volt In the grey area for a fan with single phase motor the result for the flow rate is 60 % of the rated value. 130 Roof Extract Fans / FDA / Description Notes 131 The Accessories As important as the fan itself The roof fan becomes a system if the accessories are added. They are avayable as standard components and can be supplied with the fan. ZBS 01-0031/-0125 [Al] ZBS 20-0031/-0125 [St] ZDS 01-0028/-0125 [Al] ZDS 20-0028/-0125 [St] Flat roof upstand Upstand silencer ZBU 01-0028/-0125-.. [St] Connection plate ZKE 11-0180/-0900 ZKE 13-0225 ZBS 23-0031/-0125 [St] Flat roof upstand tall Inlet connection (flexible) ZDS 09-0028/-0125-.. [Al] Inclined roof upstand silencer ZKF 11-0180/-0900 ZKF 13-0225 Mating flange ZBS 09-0031/-0125-.. [Al] Inclined roof upstand ZDR 30-0250/-0710 Inlet silencer ZLK 01-0180/-0710 ZLK 03-0225 Automatic shutter ZLK 21-0250/-0710 Motor drive shutter ZBS 11-0040/-0090 [GFK] Soaker sheet WDS ZKD 01-0250/-0710 ZSG 04-0180/-0900 Flanged inlet cone Mesh inlet guard Spacer 152 Accessories ZKK 20-0040/-0125 [St] Roof Extract Fans / Samples Samples Samples RKA 31 RGA ZDS ZBS ZKE ZLK ZKF Samples RDM ZBS ZKE ZKF 153 Roof Extract Fans / Samples Samples Samples RKM 31 RDA ZBS ZDR ZBS 09 ZKD Samples RDM 31/32 TBA / RBA ZKE ZBS ZKE ZKF 154 ZKF Roof Extract Fans / Accessories Accessories Flat roof upstand ZBS 01-0031/-0125 [Al] ZBS 20-0031/-0125 [St] Flat roof upstand tall ZBS 23-0031/-0125 [St] Inclined roof upstand ZBS 09-0031/-0125-** [Al] Ready-to-fit Flat roof upstand made of aluminium (ZBS 01) or galvanised sheet steel (ZBS 20), with sound absorbing and thermal lining. Flat roof upstand made of galvanised sheet steel (ZBS 23), with sound absorbing and thermal lining. Upstand for inclined roof made of aluminium sheet, provided with sound and thermal insulation, available in steps of 5 degrees from 5 to 45 degrees roof inclination. Order code (example): ZBS 09-0040-30 Upstand for inclined roof for RDA 31-25284E, roof inclination 30°. Soaker sheet WDS ZBS 11-0040/-0090 [GFK] Spacer ZKK 20-0040/-0125 Soaker sheets WDS, in glass fibre reinforced polyester, solve the problem of fitting a roof unit to a corrugated roof (“Pitch length” of corrugation 177 mm) with up to 25° pitch. An intermediate piece made of galvanised sheet steel (ZKK 20) has to be provided if a back draught damper is fitted together with a silencer upstand. Fitted to the upstand itprovides the necessary distance between silencer and roof fan. This garantees an even air flow without creating extra pressure losses. Connection plate ZBU 01-0028/-0125-.. [St] Connection plate made of galvanised steel sheet with threaded bolts for fixing a flanged duct. The connection plate has to be integrated into the roof with upstand silencer ZDS 01, ZDS 20 or upstand ZBS 01, ZBS 20, ZBS 13, ZBS 23 in order enable an easy connection of ductwork. ZBR 01-0031/-0056-BA 155 Roof Extract Fans / Accessories Accessories Overhead silencer ZDH 20-0250/-0710 [St] Upstand silencer ZDS 01-0028/-0125 [Al] ZDS 20-0028/-0125 [St] Inclined roof upstand silencer ZDS 09-0028/-0125-** [Al] Overhead silencer for sound reduction on discharge, houses the fan and can be easily positioned, in place of the cowl. The silencer is made from galvanised steel sheet. The overhead silencer is designed to fit to the RGA range. It is supplied with the fan as a kit to be assembled on site after installation of the fan base with motorimpeller. The Overhead Silencer ZDH is not available for ATEX fans (Type RGA 31-....-.X3G)! Noise reduction values average noise reduction ZDH 20dB Noise reduction in dB at centre frequencies in Hz 63 125 250 500 1000200040008000 0250/-0355 0450/-0500 0560/-0710 0 -3 -5 -15-22-20-13-14 0 -5 -7 -15-21-20-16-17 -4 -8 -5 -13-17-18-18-17 11 11 11 Upstand silencer for the inlet side. The exterior skin is made of aluminium (ZDS 01) or galvanised sheet steel (ZDS 20). ZDS..–0040 and ZDS ..–0056 with removable absorber lining. Inclined roof upstand silencer for the inlet side. The exterior skin is made of aluminium (ZDS 09), available in steps of 5 degrees from 5 to 45 degrees roof inclination. Pressure drop Pa 25 90 ..-00 ..-01 ZDS 71 ZDS ..-00 ..-00 ZDS ..-00 28 50 ZDS ZDS ..-00 40 100 56 150 ZDS pA 30 20 500 qV 1000 0.1 5000 10000 m³/h 40000 0.5 1.0 m³/s 5.0 10 Noise reduction values average noise reduction Noise reduction in dB at centre frequencies in Hz ZDS ..dB 63 125 250 500 1000200040008000 0028 0040 0056 0071 0090 0125 156 16 16 16 17 15 16 2 3 3 3 2 3 5 5 5 5 5 6 8 8 8 9 8 8 1218222015 1319232115 1218212015 1320252217 1117211913 1420252311 Roof Extract Fans / Accessories Accessories Inlet silencer ZDR 30-0250/-0710 The tubular inlet silencer has a square flange on the side nearest to the roof unit, for bolting to the respective flat roof upstand. It slides inside the upstand, while the opposite end can take either additional ducting or an inlet cone. The exterior skin is made of galvanised sheet steel, and the interior of galvanised perforated plate, the cavity between them is filled with non-flammable acoustic material. There is no central core of material, so that any pressure loss will be insignificant. Noise reduction values average noise reduction Noise reduction in dB at centre frequencies in Hz ZDR 30dB 63 125 250 500 1000200040008000 0250 0355 0450 0560 0710 Flanged inlet cone ZKD 01-0250/-0710 7 8 12 13 13 0 2 2 3 3 3 4 4 5 5 5 10 14 13 8 7 6 12 16 14 10 8 8.5 1720151210 91721151210 101822161210 The flanged inlet cone is for mounting under the inlet silencer, farthest from the unit, if no additional ducting is planned. This improves the intake flow environment and reduces losses. Inlet connection (flexible) ZKE 11-0180/-0900 ZKE 13-0225 Inlet connection (flexible) prevents the transmission of vibration to other parts of the installation. Flange dimensions are in accordance with DIN 24155-2. Mating flange ZKF 11-0180/-0900 ZKF 13-0225 Mating flange, for joining an internal duct to the roof unit base. Flange dimensions are in accordance with DIN 24155-2. Mesh inlet guard ZSG 04-0180/-0900 Mesh inlet guard, in accordance with EN ISO 13857. 157 Roof Extract Fans / Accessories Accessories Automatic shutter ZLK 01-0180/-0710 ZLK 03-0225 Automatic shutters ZLK 01 are working as back draught dampers at stand still of the roof fan thus avoiding uncontrolled intake of cold air. Due to turbulences generated by the back draught damper ZLK the sound data for intake and discharge may increase of app. 3 dB at discharge when a damper is fitted. Motor drive shutter ZLK 21-0250/-0710 Motor actuated shutters ZLK 21 control the exhaust air stream (mechanically or naturally generated) also if the fan is not in operation. This is true also for ventilation hoods. The shutter opens when the fan is switched on and closes at stop of the latter. When working in parallel with the fan the shutter is working like a non motorised one. Technical Data Nominal voltage ZLK 21 V 230 Nominal frequency Hz Shortcut current A Power consumption W Protection class IP 50 0.08 85 43 It is recommended to provide an intermediate duct piece between fan and shutter. For this case the indicated pressure drops are applicable. If the shutter is directly fitted after the roof fan, higher pressure drops have to be expected. The Motor drive shutter ZLK 21 is not available for ATEX fans (Type RGA 31-.....X-3G)! A short circuit proof, single phase, actuator draws the shutter flaps by highly resistant nylon ropes to open position and stays switched on during the whole opening phase. The system is not equipped with end switches which could get dirty and ineffective during live time. After being switched off a push back spring closes the shutter. The actuator has to be electrically connected to the main fan relay enabling the shutter to be opened at every time when the fan is put into operation. An auxiliary contact for closing is not necessary. When providing an motorised shutter it is recommended to fit an intermediate duct piece between fan and shutter in order to facilitate access to the shutter actuator. Connection diagram Pressure drop Pa .-0 0 56 0 K. .-0 71 0 5 45 35 ZL K. .-0 K. ZL ZL ZL 10 K. K. .-0 .-0 25 20 ZL L1 L2 L3 N 0 50 5 M 1~ 2 pA M 3~ 1 200 500 qV 158 0.1 1000 2000 0.5 5000 10000 1.0 m³/h 5.0 m³/s Roof Extract Fans / Accessories Accessories Increased corrosion protection / Powder Coating For the operation under standard climatic conditions and for ventilation units without remarkable corrosion load the standard paint execution without particular corrosion protection will be sufficient. For increased corrosion loads the corrosion protection options class “S40” or “K90” can be selected. Corrosion protection - Class S40 Degreasing, ironphosphating • Powder coating - Layer thickness ≥40 μm, Colour RAL 7039 • Wet lacquering - Layer thickness ≥40 μm (primer + lacquer finish), Colour RAL 7039 Corrosion protection - Class K90 Degreasing, ironphosphating • Powder coating - Layer thickness ≥90 μm, Colour RAL 7039 • Wet lacquering - Layer thickness ≥90 μm (primer + lacquer finish), Colour RAL 7039 Special colours (of the RAL range) on request. The plastic cowl of the roof fan line RGA cannot be painted. Roof fans in ATEX-execution cannot be supplied with a coating. 159 Roof Extract Fans / Accessories Accessories Isolator ESH 21 Execution Stylish, shockproof plastic casing, protection class IP 44/65, markings 0 and I. The isolator switch is equipped with easy-connect tapings and wiring diagram. The switch ESH 21 up to 3 kW protection class IP 44 and equipped with an integrated lock. The switch ESH 21 from 5.5 kW protection class IP 65. It is equipped with a cover coupling and an integrated lock. The turning switch can be key locked in position “On” and “Off”. Function The isolator switch is provided for isolating the fan safely from the mains during any cleaning, inspection or maintenance work, thus avoiding uncontrolled hazards by thirds who could switch the fan on. This switch is not to be considered as a main or an emergency switch. The article can vary from the figure. Attention! Combination with inverter! Special radio noise suppression measures could be necessary; never keep the switch under current, arising current peaks harm the switch and the windings. All dedicated isolator switches are equipped with auxiliary contacts (1 open and 1 close). The isolator switches for motors with inbuilt PTC thermistor are equipped with 3 auxiliary contacts in order to not trouble the preceding trigger unit by a appearing motor fault. Technical Data / Dimensions ESH 21- d b ESH 21 m 3 kW a c b ESH 21 L 3 kW a d c max. motor power kW Dimensions in mm, Subject to change a b c 3.0 73 108 45 143 0030-32 0055-32 0075-32 0110-32 0150-32 0220-32 0300-32 0370-32 0450-32 0550-32 0900-32 3.0 5.5 7.5 11.0 15.0 22.0 30.0 370 45.0 55.0 90.0 73 85 85 85 100 100 145 145 200 200 280 108 120 120 160 190 190 250 250 300 300 400 45 80 80 78 91 91 107 107 172 172 180 143 58 58 58 58 58 58 58 73 73 73 0030-62 0055-62 0075-62 0110-62 0150-62 0220-62 0300-62 0370-62 0450-62 0750-62 3.0 5.5 7.5 11.0 15.0 22.0 30.0 37.0 45.0 75.0 73 85 100 100 145 145 200 200 300 280 108 120 190 190 250 250 300 300 300 280 45 90 91 91 100 107 172 172 172 230 143 58 58 58 58 58 73 73 73 73 0030-25 3.0 73 108 45 143 0030-35 0075-35 3.0 7.5 73 85 108 120 45 106 143 58 0030-65 0075-65 3.0 7.5 73 110 108 66 45 110 143 51 0075-95 7.5 110 66 110 51 The isolator switches are classified following to the motor rating. The type designation indicates the main data. Example: ESH 21-0030-65 =3 kW-switch 6 main contacts 5 auxiliary contacts 160 d 0030-22 Roof Extract Fans / Accessories Accessories for three-phase current motors (standard motors) without thermal contacts Design Plastic casing in protection class IP 55, permissible ambient temperature +40 °C, 40 Hz – 60 Hz, frontal operation, for wall mounting. Motor protection unit for singlespeed, non- variable speed three-phase current motors without thermal contacts. Function The motor protection units must be adjusted on site to the trigger current. If the preset trigger current is exceeded, the device disconnects the motor from the mains supply via a thermal overload release. Pressing the “on key” causes the unit to turn on again. All motor protection units EUM 33 are also suitable for the protection of EExe-motors (PTB-Prüfung Gesch-Nr. 3.35/386.3060). They must however be mounted outside of explosion endangered areas, since they are not themselves designed with explosion protection. Technical Data EUM Continuous flow A Setting range A max. rated power AC-3 kW 33-0004-8D 33-0006-8D 33-0010-8D 33-0016-8D 33-0024-8D 33-0040-8D 33-0060-8D 33-0100-8D 33-0160-8D 33-0200-8D 33-0250-8D 33-0500-8D 33-0580-8D 0.4 0.6 1.0 1.6 2.4 4.0 6.0 10.0 16.0 20.0 25.0 50.0 58.0 0.24/-0.4 0.09 0.4/- 0.6 0.12 0.6/- 1.0 0.25 1.0/- 1.6 0.55 1.6/- 2.4 0.80 2.4/- 4.0 1.50 4.0/- 6.0 2.50 6.0/-10.0 4.00 10.0/-16.0 7.50 16.0/-20.0 9.00 20.0/-25.0 12.50 40.0/-50.0 25.00 50.0/-58.0 30.00 Dimensions in mm, Subject to change 160 181 Motor protection unit EUM 33 97 47.5 114 130 Connection diagram L1 L2 L3 PE EUM33 1 3 5 2 4 6 U1 V1 W1 161 Roof Extract Fans / Accessories Accessories Motor protection unit ESM 01-/11-/12-/13- for motors with fitted thermal control sensors (thermal contacts, PTC) Design Beautifully shaped plastic casing made of shock resistant polystyrol, protection class IP 54. All units are suitable for wall mounting and include: hand switches for frontal operation, operational signal lamp and control safety accessible from outside. Permissible ambient temperature: +40 °C. Function Should the motor winding temperature rise excessively, the imbedded motor winding thermal contact or PTC will open the control circuit, causing the mains relay to drop out and thus disconnect the motor from the mains supply. The motor will also be turned off in the case of a mains-side dropout of the control phase, as well as if the contacts fail or if the mains supply is interrupted. The motor protection units are not equipped with an automatic re-poweron after a mains voltage failure and are thus fail-safe. After the motor windings have cooled down, a lock-out device in the relay circuit prevents the motor from switching itself on. The hand switch must first be momentarily turned to the 0-position and then back to the ‘on’ position. The operational signal lamp indicates the operation of the motor. It goes out in the case of a malfunction. The motor protection units are suitable for group switching, i. e. several motors with the same switching can be connectedto a common switchingdevice. The sum of the motors’ rated power may not exceed the maximal device rated power. The thermal contacts of all motors are to be switched in series. The PTCs switched in series may not exceed the sum of 6. Technical Data for motors with thermal contacts ESM max. permitted rated motor power kW Nominal voltage V Weight 01-0020-5E2.0 01-0040-8D4.0 02-0040-8D4.0 03-0040-8D4.0 04-0040-8D4.0 230 400 400 400 400 0.9 0.9 0.9 0.9 0.9 for motors with PTC ESM Nominal voltage V Weight 4000 400 400 0.9 0.9 0.9 max. permitted rated motor power kW 11-0040-8D4.0 12-0040-8D4.0 13-0040-8D4.0 For connection type see diagrams 140 30 Dimensions in mm, Subject to change 190 Please use the enclosed wiring diagrams in the control boxes always! 162 150 kg kg Roof Extract Fans / Accessories Accessories Motor protection unit Connection diagram ESM 01-0020-5E Alternating current model, single speed ATTENTION: for thermo contacts (TK) use always series connection! N L1 TK TK TK TK U1 U1 U1 U2 U2 U2 TK U1 Z2 TK Z1 U2 Anti-clockwise rotation TK TK TK TK TK TK TK TK Connection with 2 motors TK U1 Z2 TK Z1 U2 TK TK TK TK TK TK TK TK PE N L1 Mains Clockwise rotation TK TK Connection with 3 motors Motor 1-phase Connection diagram ESM 01-0040-8D Three-phase current model, single speed ESM 02-0040-8D Three-phase current model, 2 speed with two separate windings ATTENTION: for thermo contacts (TK) use always series connection! N L1 L2 L3 TK TK TK TK U1 U1 U1 V1 V1 V1 W1 W1 W1 ATTENTION: for thermo contacts (TK) use always series connection! N L1 L2 L3 TK TK TK TK TK TK TK TK TK TK TK TK TK TK Connection with 2 motors PE N L1 L2 L3 Mains TK U1 V1 W1 TK TK TK TK TK U1 V1 W1 TK TK TK TK TK W2 U2 V2 TK TK TK W2 U2 V2 TK TK PE N L1 L2 L3 Connection with 3 motors Motor 3-phase TK TK TK TK 1U 1V 1W 2U 2V 2W Mains TK TK TK TK Connection with 3 motors Motor 3-phase ESM 04-0040-8D Three-phase current model, 2 speed with Y/g-connection ATTENTION: for thermo contacts (TK) use always series connection! N L1 L2 L3 TK TK TK TK TK TK TK TK TK TK TK TK TK TK TK TK TK TK U1 V1 W1 U2 V2 W2 TK TK Connection with 2 motors Connection with 2 motors Mains TK TK TK TK TK TK ATTENTION: for thermo contacts (TK) use always series connection! PE N L1 L2 L3 1U 1V 1W 2U 2V 2W Connection with 2 motors Connection diagram ESM 03-0040-8D Three-phase current model, 2 speed with Dahlander winding N L1 L2 L3 TK TK TK TK TK TK TK TK TK 1U 1V 1W TK TK TK TK TK U1 V1 W1 TK TK TK 2W 2U 2V TK TK TK W2 U2 V2 TK TK TK TK Connection with 3 motors PE N L1 L2 L3 Motor 3-phase Mains TK TK TK TK Connection with 3 motors Motor 3-phase 163 Roof Extract Fans / Accessories Accessories Motor protection unit Connection diagram ESM 11-0040-8D Three-phase current model, single speed ESM 12-0040-8D Three-phase current model, 2 speed with two separate windings ATTENTION: for PTC (KL) use always series connection! N L1 L2 L3 KL KL KL KL U1 U1 U1 V1 V1 V1 W1 W1 W1 ATTENTION: for PTC (KL) use always series connection! N L1 L2 L3 KL KL KL KL KL KL KL KL KL KL KL KL KL KL KL U1 V1 W1 KL KL KL KL KL U1 V1 W1 KL KL KL KL KL W2 U2 V2 KL KL KL W2 U2 V2 KL KL PE N L1 L2 L3 Motor 3-phase Connection diagram ESM 13-0040-8D Three-phase current model, 2 speed with Dahlander winding ATTENTION: for PTC (KL) use always series connection! N L1 L2 L3 KL KL KL KL 1U 1V 1W 2U 2V 2W KL KL KL KL KL KL KL KL Connection with 2 motors PE N L1 L2 L3 Mains 164 KL KL KL KL KL KL Connection with 3 motors Mains 1U 1V 1W 2U 2V 2W Connection with 2 motors Connection with 2 motors PE N L1 L2 L3 KL KL KL KL KL KL KL KL KL 1U 1V 1W KL KL KL 2W 2U 2V KL KL KL KL Connection with 3 motors Motor 3-phase Mains KL KL KL KL Connection with 3 motors Motor 3-phase Roof Extract Fans / Accessories Accessories Transformer ETO 10 with 7 secondary taps Design Transformer according to DIN VDE 0550-1 with built-on terminal strip for 7 taps, without casing, suitable for control cabinet installation. Two transformers are necessary for three-phase current, which are to beconnected in a V-switching configuration (see Wiring diagram). Permissible ambient temperature at nominal current loading max. +35 °C. ETO 10-....-5E Primary voltage: 230 V / 50-60 Hz Secondary voltage: 230/180/160/140/120/100/80 V ETO 10-....-8D Primary voltage: 400 V / 50-60 Hz Secondary voltage: 400/310/270/235/200/170/140 V Technical Data | Dimensions Alternating current model Nominal Dimensions in mm, current Subject to change ETO A abceøfhkg c Measurement diagram øf h b 1.8 4.0 7.0 13.0 22.0 78 60 92 56 4.8 44 1.5 96 80 107 84 5.8 61 2.5 120 95 126 90 5.8 73 4.5 1351101351045.8 86 7.0 1351501351045.8 12612.5 Connection diagram 80 V 120 V 140 V 160 V U2 1.0 2.0 4.0 6.5 15.0 78 60 92 56 4.8 44 1.5 96 80 107 84 5.8 61 2.5 120 95 126 90 5.8 73 4.5 135 110 135 104 5.8 86 7.0 1351501351045.8 12612.5 Connection diagram Mains L1 Motor L2 L3 U1 V1 W1 0V 140 V 170 V 200 V 235 V 270 V 310 V 400 V h b 10-0010-8D 10-0020-8D 10-0040-8D 10-0065-8D 10-0150-8D 400 V 310 V 270 V 235 V 200 V 170 V 140 V 0V øf e a U1 Technical Data | Dimensions Three-phase current model Nominal Dimensions in mm, current Subject to change ETO A abceøfhkg c Measurement diagram N 180 V 230 V L Motor 0V Mains 100 V e a 10-0018-5E 10-0040-5E 10-0070-5E 10-0130-5E 10-0220-5E 165 Roof Extract Fans / Accessories Accessories Speed setting ETH 31-/35-/36-/37- transformatic, 5-step, with casing Design Completely plastic casing in protection class IP 54, Type: ETH 31, 35 and ETH 37-0010/-0020-8D. Painted metal casing in protection class IP 23, Type: ETH 36 and ETH 37-0040/-0070-8D. All units are suitable for wall mounting and include: speed control via hand switch with 0-position and 5 switching steps, operating signal lamp, 230 V output for e. g. a solenoid valve. Permissible ambient temperature: -25 °C up to +40 °C. ETH 31 These units include no motor protection unit. Protection switches for thermal contact connections are to be laid in the conductor between the control device and the motor. In Nicotra Gebhardt externallymounted rotor motors, the thermal contacts are already bound into the motor winding. ETH 35, ETH 36, ETH 37 These units possess a motor protection installation for thermal contact or PTC connection with a supplementary warning signal lamp, a potential-free exchanger and a potential-afflicted (230 V) room thermostat connection (remote on – off). Function For motors with built-in thermal contacts, these open the control current circuit when the permissible winding temperature is exceeded (ETH 31, 35, 36). Motors equipped with PTC thermistor give an electrical signal to the trigger unit (ETH 37) when the temperature exceeds the default value. The trigger controls the main relay thus cutting the motor feed. This causes the main fuse to fall out and disconnect the motor from the mains. After the motor winding has cooled down (ca. 2 Min.) or after remedying the cause of the malfunction, respectively, turn the main switch temporarily to the 0-position and then back to the operational position. Dimensions in mm, Subject to change 1 2 3 4 f 5 b d 0 a 166 c g e ETH abcdef gkg 31-0020-5E 31-0040-5E 35-0040-5E 35-0070-5E 36-0200-5E 35-0010-8D 35-0020-8D 36-0040-8D 36-0070-8D 36-0140-8D 37-0010-8D 37-0020-8D 37-0040-8D 37-0070-8D 155200150144 986.2 30 155200150144 986.2 30 155200150144 986.2 30 2002541701941406.2 30 2253051652651886.2 30 155200150144 986.2 30 2002541701941406.2 30 2253051652651886.2 30 2253051652651886.2 30 3023852233502656.2 30 2002541701941406.2 30 2002541701941406.2 30 2253051652651886.2 30 2253051652651886.2 30 4.0 4.0 4.0 8.0 17.0 6.0 8.0 14.0 20.0 35.0 5.5 8.0 14.0 20.0 Roof Extract Fans / Accessories Accessories Speed setting ETH 31-/35-/36-/37- transformatic, 5-step, with casing Technical Data Alternating current model without motor protection installation Nominal current A Mains safety ETH 31-0020-5E 31-0040-5E 2.0 4.0 2 AT 6 AT Primary voltage: 230 V; 50-60 Hz Secondary voltage: 60/105/130/160/230 V Technical Data Alternating current model with motor protection installation ETH Nominal current Mains safety A 35-0040-5E 35-0070-5E 36-0200-5E 4.0 7.0 20.0 6 AT 8 AT 20 AT Primary voltage: 230 V; 50-60 Hz Secondary voltage: 60/105/130/160/230 V Technical Data Three-phase current model with motor protection installation ETH Nominal current Mains safety A 35-0010-8D 35-0020-8D 36-0040-8D 36-0070-8D 36-0140-8D 1.0 2.0 4.0 7.0 14.0 1 AT 2 AT 4 AT 8 AT 16 AT Primary voltage: 400 V; 50-60 Hz Secondary voltage: 140/180/230/280/400 V Technical Data Three-phase current model with motor protection installation for motors with PTC ETH 37-0010-8D 37-0020-8D 37-0040-8D 37-0070-8D Nominal current Mains safety A 1.0 2.0 4.0 7.0 1 AT 2 AT 4 AT 8 AT Primary voltage: 400 V; 50-60 Hz Secondary voltage: 140/180/230/280/400 V 167 Accessories Speed setting ETH 31-/35-/36-/37- transformatic, 5-step, with casing Connection diagram ETH 31 N L1 PE U1 U2 PE L1 N PE N L1 PE U1 U2 PE L1 N Motor Mains Connection diagram ETH 35-/36-....-5E N L1 PE U1 U2 TK TK RT RT PE L1 N 11 12 14 PE N L1 PE U1 U2 Mains Motor PE L1 N 11 12 14 Connection diagram ETH 35-/36-....-8D N L1 L2 L3 PE N L1 L2 L3 Mains PE U1 V1 W1 TK TK RT RT PE L1 N 11 12 14 PE U1 V1 W1 Motor PE L1 N 11 12 14 Connection diagram ETH 37-....-8D N L1 L2 L3 PE N L1 L2 L3 Mains PE U1 V1 W1PTC PTC RT RT PE L1 N 11 12 14 PE U1 V1 W1 Motor PE L1 N 11 12 14 TK = Thermal contact of the motor PTC= P ositive Temperature Coefficient (PTC-Thermistor) of the motor RT = Room thermostat or external switch 1 = additional outlet e. g. for solenoid valve, lamp, etc. 2 = free contacts for the status signal “Operating/Malfunction” 168 Roof Extract Fans / Accessories Accessories electronic, stepless Design Shock-resistant plastic casing (creamwhite) in protection class IP 44, with turn knob on the front side. Clearly arranged terminal strip for mains and motor connection. For use as an integral version in a standard switch box, the speedregulator with its front plate is simply removed from the casing underside. Function The transformer contains a turn knob for the variation of the nominal value by means of phase-angle control, semiconductor fuse and a response output. The transformer EPH is not equipped with any motor protection installation! If thermo contacts are in use it is recommended to assure the electrical safety by installing motor protection units EUM 11-0100-5E (IP 54) or EUM 21-0100-5E (IP 00, for integration in a panel). Technical Data EPH NominalNominalFrequency Fuse currentvoltage A V Hz 03-0010-5E 03-0020-5E 03-0040-5E 1.0 2.0 4.0 230/240 230/240 230/240 50/60 50/60 50/60 Dimensions in mm, Subject to change EPH 03-0010/-0040-5E Surface mounting version F 1.0 A F 2.0 A F 4.0 A EPH 03-0010/-0020-5E flush mounting version Sealing ø4 64 Transformer EPH 03 82 ~65 24 32 Connection diagram N N Re L M N 169 Roof Extract Fans / Accessories Accessories Transformer EPA 83 electronic, stepless, digital Electronic controller for pressure, airspeed, temperature, with stepless adjustable output voltage for fans with controllable alternating current or threephase current motors respectively. Design EPA 83 Surface mounting version Plastic casing with die-cast aluminium base-plate in protection class IP 54. Function The pressure controller EPA 83 is equipped with a main switch, a motor protection by thermal contact or PTC thermistors, nominal value input, main switch/automatic with bypass-function, actual value input for sensors with 0...10 V signal (Temperature sensor EIT, Differential pressure sensor EIP and Air velocity sensor EIL), for sensors with 4...20 mA signal; semiconductor fuses and adjustment options for minimal and maximal speed, menu-directed set-up via three function keys, output (0...10 V), potential-free operation signal contact, external nominal value preset via potentiometer, integrated semiconductor fuses, phase monitoring, controller block, reset pushbutton connection. 170 Technical Data Alternating current design Protection class EPA IP max. current Nominal Frequency consumptionvoltage A V Hz app. Weight kg 83-0060-5E 83-0100-5E 0.2/- 6.0 230 0.2/-10.0 230 1.6 2.6 54 54 50/60 50/60 Technical Data Three-phase current design Protection class EPA IP max. current Nominal Frequency consumptionvoltage A V Hz app. Weight kg 83-0050-8D 83-0100-8D 83-0150-8D 83-0250-8D 0.2/- 5.0 0.5/-10.0 0.5/-15.0 0.5/-25.0 2.7 3.1 5.2 13.6 54 54 54 54 400 400 400 400 50/60 50/60 50/60 50/60 Roof Extract Fans / Accessories Accessories Transformer EPA 83 electronic, stepless, digital Dimensions in mm, Subject to change EPA 83-0060-5E Surface mounting version EPA 83-0100-5E Surface mounting version 128 102 140.5 115 240 ø5.5 60 10 264 225 137 185 30 213 198 5 186 Dimensions in mm, Subject to change EPA 83-0050-8D Surface mounting version 13 EPA 83-0100-8D Surface mounting version 131 115 131 115 13 186 Dimensions in mm, Subject to change EPA 83-0150-8D Surface mounting version 13 EPA 83-0250-8D Surface mounting version 131 115 304 282 267 261 244 ø5.5 435 394 320 264 225 12 240 17 37 186 ø5.5 264 225 240 ø5.5 264 225 240 186 13 ø9 171 Roof Extract Fans / Accessories Accessories Transformer EPA 83 electronic, stepless, digital Connection diagram EPA 83-....-5E Auto 0 100% V + PE N L1 Analog IN 1 TK TK 1* Analog IN 2 24V Digital IN 2 21 22 24 K2 Analog OUT 1 PE PE N N L1 L1 U1 U1 U2 U2 11 12 14 K1 D1 D1 A1 GND D2 D2 E2 GND E1 GND DATA - GND RS485 E2.1 E2.2 GND 1 U1 U2 PE TK TK 1* If function is not needed, M terminals must be bridged 1~ Mains 1~ 230 V 50/60 Hz mA E1.1 E1.2 Digital IN 1 DD+ Max. contact capacity 5 A / 250 V AC °C Input 0...10 V (Ri >100 k) 0...20 mA 4...20 mA KTY10-6 (-8...+43 °C) 2 Output 0...10 V (Imax=10 mA) 1-phase motor with integrated thermo contacts Input 0...10 V (Ri >100 k) 0...20 mA 4...20 mA KTY10-6 (-24...+80 °C) Analog IN 2 Digital IN 2 TK TK Analog IN 1 11 14 12 21 24 22 K2 K1 24 V DC OUT 1 GND N L1 L2 L3 U V W Analog OUT 1 Max. contact capacity 5 A / 250 V AC Digital IN 1 Connection diagram EPA 83-....-8D D1 D1 A GND 24V 24V E1 GND E2 GND D2 D2 E1.1 E1.2 1 PE N L1 L2 L3 Mains 1~ 230 V 50/60 Hz U V W PE M 3~ TK TK 3-phase motor with integrated thermo contacts 172 Output Input 0...10 V 0...10 V (Imax=10 mA) (Ri >100 k) 0...20 mA 4...20 mA KTY10-6 (-24...+80 °C) 2 Input 0...10 V (Ri >100 k) 0...20 mA 4...20 mA KTY10-6 (-8...+43 °C) °C E2.1 E2.2 V mA DD+ GND 24V Roof Extract Fans / Accessories Standard component of brushless DC fans Elektronical Commutation Unit EKE 05 for Nicotra Gebhardt brushless DC motors Execution Electronical commuter unit with single phase input and and variable output voltage and frequency, specially designed for matching to the operation of roof fans with brushless DC motors. By using most modern power semi conductors a high efficiency at any speed is guaranteed. The output voltage is generated at high pulse frequencies (15 kHz). Specification - suitable for operating Nicotra Gebhardt brushless DC motors exclusively - for single phase feed line 208-277 V / 47-63 Hz - max. motor rating of 380 W - internal power limitation - max. ambient temperature at operation -10 °C to +40 °C - setting of max. and min. rpm possible (possibility of setting reduced speed at night) - analogue interface 0...5 V / 0...10 V - Monitoring of operation (potential-free error reading) - no error contact closed - error (e.g. no current) contact closed - Reset and programming button - easy and simple maximum speed programming Standards and guide lines Radio frequency suppression to EMV basic standard EN 50081-1 (residential and business areas) and EN 61000-3-2 is met by using integrated filters and power factor controller (PFC). Technical Data Input Output Nominal Nominal Power Voltage / Voltage power output factor Frequency current EKE V / Hz (1~)Vpic-pic (=)W A (3~) cos phi 05-0018-5E-IA 208...277 / 47...63 420 1.74 0.99 400 Protection class IP20 Connection diagram 1 mains 2 analog input Nmin Nmax 3 error contact opener 4 reset / programming 1 5 programming LED 4 A B 6 error LED 1 2 3 1 8 1 8 7 operating LED Links Nmin 1 2 3 4 A B Nmax 1 2 3 4 A B Nmin Nmax = +5 V = 0...10 V = 0... 5 V = ground = error contact = error contact = minimal speed setting = maximal speed setting 173 Roof Extract Fans / Accessories Accessories Speed Regulator Module EGH 01 for Roof Fans with brushless DC motor or frequency inverter Design - rotary knob to switch and stepless speed variation - Impact-resistant plastic casing (cream-coloured) in protection class IP44 - also for integration in a normal switching box - clearly visible and identifiable terminal strip for connections Function The module has a rotary knob for on/off and stepless speed variation through the analogue input of the inverter (BLDC driver, frequency inverter). Technical Data protection class Weight Type kW switching contact IP kg EGH 01 10 44 0.145 10 A / 12 V DC Dimensions in mm, Subject to change Surface mounting version flush mounting version Sealing 64 ø4 ~65 82 24 Connection diagram 174 T max. 4A / 250V AC +10V 0...10V 10A / 12V DC (+5V) (0...5V) 32 Roof Extract Fans / Accessories Accessories Frequency inverter G110 MM420 Design Frequency inverter with variable output voltage and frequency, specially designed for the operation of centrifugal fans with induption motors. Due to the use of modern power semiconductors it is possible to achieve a speed of revolution with high efficiency. Switching frequencies up to 16kHz can be set with all types. If the highest switching frequencies are required (for example for reasons of noise reduction), the maximum output current is decreased, in which case the performance category should be specially checked. The overall package includes the frequency inverter, filter for class B (for residential and commercial uses) as well as a control unit. General Performance characteristics Motor protection feature for motors with thermistor temperature sensors, adjustable accelaration and deaccelaration ramps, minimum and maximum rotation speeds, fixed rotation speeds, trapping switch during operation, programmable inputs and PI-controller (MM420 and MM430 only), RS 485 serial interface as well as a detailed operating instructions. Caution about combination with isolators (ESH)! Special EMC-action can be necessary, furthermore do not switch during operation, overvoltages can destroy the switch and the motor-winding. Performance range G110 1AC 230V (for single-phase AC supply) 0.25 to 2.2 kW rated motor power, 200 to 240V ±10% single-phase AC, 47 to 63Hz, three-phase current output 3 × 230V AC, protection class IP 20. Permitted ambient temperature during operation: -10 °C to +40 °C. Performance range MM420 3AC 400V (for three-phase AC supply) 0.55 to 11kW rated motor power, 380 to 480V ±10% three-phase AC, 47 to 63Hz, three-phase current output 3 × 400V AC, protection class IP 20. Permitted ambient temperature during operation: -10 °C to +50 °C. The interference suppression filter required to comply with the EMC basic interference suppression standard EN 500811 (residential and commercial uses) is integrated into the package as substructure option. Power choke to comply with EN 61000-3-2 as additional component. Observe performance reduction when using high clock frequencies! Performance range MM430 3AC 400V (for three-phase AC supply) 15 to 250kW rated motor power, 380 to 480V ±10% three-phase AC, 47 to 63Hz, three-phase current output 3 x 400V AC, protection class IP 20. Permitted ambient temperature during operation: -10 C to +50 °C. The interference suppression filter required to comply with the EMC basic interference suppression standard EN 50081-1 (industrial applications) is partially integrated. In order to attain EMC requirements Class B a frequency inverter without filter should be selected. The appropriate EMC-B filter is then required as an additional component. Observe performance reduction when using high clock frequencies! 175 Roof Extract Fans / Accessories Accessories Frequency inverter G110 MM420 The indicated ratings of the units are made for a quick selection. The exact dedication of an inverter in this catalogue is made by taking into account of the max. admitted current at a pulse frequency of 4kHz. It is important to know that at higher pulse frequencies the supplied current of the inverter will be decreasing, with the possible consequences of having to select a larger inverter unit. Also longer feed lines or additional radio frequency filters may lead to the choice of a larger inverter size. Technical Data for three-phase AC motors on the single-phase supply(1~ power) SINAMICS** G110 Parts of the unit Accessories Unit NominalNominalFrequency Filter Control Line current power inverter class B panel choke G110 1AC 230V A (4kHz/+40 °C) kW 6SL3211-6SE6400-6SL3255-6SE64000.25KW EMV B 0.37KW EMV B 0.55KW EMV B 0.75KW EMV B 1.10KW EMV B 1.50KW EMV B 2.20KW EMV B 1.70 2.30 3.20 3.90 6.00 7.80 11.00 0.250AB12-5BA0integriert 0.370AB13-7BA0integriert 0.550AB15-5BA0integriert 0.750AB17-5BA0integriert 1.100AB21-1AA0integriert 1.500AB21-5AA0integriert 2.200AB22-2AA0integriert 0AA00-4BA0 3CC00-4AB3 0AA00-4BA0 3CC01-0AB3 0AA00-4BA0 3CC01-0AB3 0AA00-4BA0 3CC01-0AB3 0AA00-4BA0 3CC02-6BB3 0AA00-4BA0 3CC02-6BB3 0AA00-4BA0 3CC02-6BB3 Technical Data for three-phase AC motors on the three-phase supply (3~ power) MICROMASTER** 420 Parts of the unit Accessories Unit NominalNominalFrequency Filter Control Line current power inverter class B panel choke MM420 3AC 400V A (4kHz) kW 6SE6420-6SE6400-6SE6400-6SE64000.55KW EMV B 0.75KW EMV B 1.10KW EMV B 1.50KW EMV B 2.20KW EMV B 3.00KW EMV B 4.00KW EMV B 5.50KW EMV B 7.50KW EMV B 11.0KW EMV B 1.60 2.10 3.00 4.00 5.90 7.70 10.20 13.20 18.40 26.00 G110 MM420 0.552UD15-5AA12FB00-6AD0 0BP00-0AA0 3CC00-2AD3 0.752UD17-5AA12FB00-6AD0 0BP00-0AA0 3CC00-4AD3 1.102UD21-1AA12FB00-6AD0 0BP00-0AA0 3CC00-4AD3 1.502UD21-5AA12FB00-6AD0 0BP00-0AA0 3CC00-6AD3 2.202AD22-2BA12FS01-6BD0 0BP00-0AA0 3CC01-0BD3 3.002AD23-0BA12FS01-6BD0 0BP00-0AA0 3CC01-0BD3 4.002AD24-0BA12FS01-6BD0 0BP00-0AA0 3CC01-4BD3 5.502AD25-5CA12FS03-8CD0 0BP00-0AA0 3CC02-2CD3 7.502AD27-5CA12FS03-8CD0 0BP00-0AA0 3CC02-2CD3 11.002AD31-1CA02FS03-8CD0 0BP00-0AA0 3CC03-5CD3 Technical Data MM430 for three-phase AC motors on the three-phase supply (3~ power) MICROMASTER** 430 Accessories Unit NominalNominalFrequency Filter Control Filter Line current power inverter class A panel class B choke 6SE6400-* MM430 3AC 400V A (4kHz) kW 6SE6430-6SE6400-6SE6400-6SE6400-6SL3000-° 32.00 15.02AD31-5CA0integriert 0BE00-0AA0 2FS03-8CD0 *3CC03-5CD3 38.00 18.52AD31-8DA0integriert 0BE00-0AA0 *** *3CC04-4DD0 45.00 22.02AD32-2DA0integriert 0BE00-0AA0 *** *3CC04-4DD0 62.00 30.02AD33-0DA0integriert 0BE00-0AA0 *** *3CC05-2DD0 75.00 37.02AD33-7EA0integriert 0BE00-0AA0 *** *3CC08-3ED0 90.00 45.02AD34-5EA0integriert 0BE00-0AA0 *** *3CC08-3ED0 110.00 55.02AD35-5FA0integriert 0BE00-0AA0*** *3CC11-2FD0 145.00 75.02AD37-5FA0integriert 0BE00-0AA0*** *3CC11-2FD0 178.00 90.02AD38-8FA0integriert 0BE00-0AA0*** *3CC11-7FD0 180.40110.02UD41-1FA00BE32-5AA00BE00-0AA0– °0CE32-3AA0 220.00132.02UD41-3FA00BE34-4AA00BE00-0AA0– °0CE32-8AA0 265.80160.02UD41-6GA00BE34-4AA00BE00-0AA0– °0CE33-3AA0 325.60200.02UD42-0GA00BE34-4AA00BE00-0AA0– °0CE35-1AA0 419.80250.02UD42-5GA00BE36-0AA00BE00-0AA0– °0CE35-1AA0 176 Roof Extract Fans / Accessories Accessories Frequency inverter G110 ** SINAMICS and MICROMASTER are registered trademarks of SIEMENS AG *** In order to comply with EMC requirements class B, a frequency inverter without filter should be chosen. The appropriate EMC-B filter is then additionally required. MM420 a Dimensions in mm, Subject to change for three-phase AC motors on the single-phase supply (1~ power) SINAMICS** G110 b c G110 Unit G110 1AC 230V Frequency inverter 6SL3211- Nominal power kW a b 0.25KW EMV B 0.37KW EMV B 0.55KW EMV B 0.75KW EMV B 1.10KW EMV B 1.50KW EMV B 2.20KW EMV B 0AB12-5BA0 0AB13-7BA0 0AB15-5BA0 0AB17-5BA0 0AB21-1AA0 0AB21-5AA0 0AB22-2AA0 0.25 0.37 0.55 0.75 1.10 1.50 2.20 c 150 90 116 150 90 116 150 90 131 150 90 131 160140142 160140142 181184152 a Dimensions in mm, Subject to change for three-phase AC motors on the three-phase supply (3~ power) MICROMASTER** 420 b c a c 0.8 0.8 0.9 0.9 1.5 1.5 2.1 MM420 Unit MM420 3AC 400V Frequency inverter 6SE6420- Nominal power kW a b 0.55KW EMV B 0.75KW EMV B 1.10KW EMV B 1.50KW EMV B 2.20KW EMV B 3.00KW EMV B 4.00KW EMV B 5.50KW EMV B 7.50KW EMV B 11.0KW EMV B 2UD15-5AA1 2UD17-5AA1 2UD21-1AA1 2UD21-5AA1 2AD22-2BA1 2AD23-0BA1 2AD24-0BA1 2AD25-5CA1 2AD27-5CA1 2AD31-1CA0 0.55 0.75 1.10 1.50 2.20 3.00 4.00 5.50 7.50 11.00 c 173 73 149 173 73 149 173 73 149 173 73 149 202 149 172 202 149 172 202 149 172 245 185 195 245 185 195 245185195 Dimensions in mm, Subject to change for three-phase AC motors on the three-phase supply (3~ power) MICROMASTER** 430 b Weight kg Weight kg 1.0 1.0 1.0 1.0 3.3 3.3 3.3 5.0 5.0 5.0 MM430 Unit Frequency inverter Nominal power MM430 3AC 400V 6SE6430- kW a – – – – – – – – – – – – – – 2AD31-5CA0 2AD31-8DA0 2AD32-2DA0 2AD33-0DA0 2AD33-7EA0 2AD34-5EA0 2AD35-5FA0 2AD37-5FA0 2AD38-8FA0 2UD41-1FA0 2UD41-3FA0 2UD41-6GA0 2UD42-0GA0 2UD42-5GA0 15.0 18.5 22.0 30.0 37.0 45.0 55.0 75.0 90.0 110.0 132.0 160.0 200.0 250.0 245 185 520 275 520 275 520 275 650 275 650 275 1150 350 1150 350 1150 350 1450326 1450326 1533326 1533326 1533326 b Weight c kg 195 245 245 245 245 245 320 320 320 356 356 545 545 545 5.7 17 17 17 22 22 75 75 75 116 116 176 176 176 177 Roof Extract Fans / Accessories Accessories Differential pressure sensor EIP 01 Sensor with membrane for measuring the pressure, negative pressure or differential pressure of nonaggressive gases. Type The differential pressure to be measured acts transformed into an output signal of 0...10 V by electronics (in SMD technology). Application ranges Volume flow regulators in centrifugal fans (with volume flow measuring device IMV) in connection with a frequency inverter type G110, MM420, MM430, or a universal regulator appliance type ERA 02-4000-5E in connection with a frequency regulator Electrical connection and installation The differential pressure sensor delivers a starting signal (0-10 V) by pressure increase at the ”Plus” connection opposite pressure on the ”Minus” connection. Voltage supply: 15-30 V DC or 24 V AC, ±15 %. Pressure connections must point downward, tube connection ø5 mm. Measuring accuracy Null drift: ±0.75 % Sum of linearity and hysteresis: ±1 % Temperature drift zero point: ±0.3 % / 10 K Temperature drift length of measurement: ±0.2 % / 10 K Technical Data Measuring Protection max. current range type consumption EIP Pa ca. mA Overload Output signal protectionprop. Pa V DC Operating temperature °C 01-0200-12 01-0500-12 01-1000-12 01-2000-12 01-4000-12 20000 20000 20000 20000 20000 0 ... +50 0 ... +50 0 ... +50 0 ... +50 0 ... +50 0 - 200 0 - 500 0 - 1000 0 - 2000 0 - 4000 IP65 IP65 IP65 IP65 IP65 12 12 12 12 12 0-10 0-10 0-10 0-10 0-10 Dimensions in mm, Subject to change 50 ca. 500 4,5 70 Connection diagram Pressure connections Ø5 mm ø5 8 16 Voltage supply 15...30 V DC 24 V AC ±10 % brown +~ + p yellow Output p 0 ... 10 V DC white = ^ ~ 178 Roof Extract Fans / Accessories Accessories Universal control device ERA 02 for installation in control cabinets Digital control module for controlling pressure, air velocity or volume flow (PI controller). For example, a transformer for fans is controlled via the 0-10 V output. The device is designed for installation in control cabinets. Type Multi functional LC-display for actual and nominal values (m/s, hPa = mbar, 100 m³/h). Menuassisted adjustment via three function keys. Actual value input 0-10 V e.g. for: - air speed sensors Type EIL in measuring ranges from 0-1 m/s and 0-10 m/s e.g. for: Air velocity control in clean room technology - Pressure sensors Type EIP... in measurement ranges 50-4000 Pa e. g. for: Pressure control in canal systems of air conditioning systems (VVS), Flow control in centrifugal fans with pressure tappings in the inlet cone.The control module calculates the required flow (m³/h) from the differential measured pressure between the surrounding level and inlet cone. Max. volume flow 65000 m³/h - Output 0-10 V e. g. for controlling a transformer. - Failure message is output via display (internal/external) and relay programmable. - External set value specification via potentiometer or 0-10 V signal. - Specification of two set values (day/night), can be switched over externally or via keyboard. - Protection against unauthorised setting by keyboard code. Application area -P ressure regulation for centralised ventilation systems and variable volume flow systems for building air conditioning (VVS) e.g. in combination with a frequency inverter or a commutation unit or a transformer and a pressure sensor. -V olume flow regulation for centrifugal fans (with measuring stub in the inlet cone) e.g. in combination with a frequency inverter or a commutation unit or a transformer or a mini-interface inverter and a pressure sensor and the volume flow volumeter. -A ir speed regulation for clean room systems, e.g. in combination with a transformer and an air speed sensor. Electrical connection and installation Connection to 230 V, 50/60 Hz. The control module can be installed in a control cabinet door. Admissible relative humidity: 85 %, noncondensing. Power supply for the sensors included: +24 V, ±20 %, Imax = 70 mA. _ _ qV = K p = K10 r2 p Setting options – Set values in the measurement range of the sensor (m/s, hPa = mbar), or in the volume flow range of the fan (x 100 m³/h) – Switch over of set value (day/night) – Min./max. setting range – Translation of performance curve (P component) – Constant of integration can be selected (I component) – Reversal of the effect of the control behaviour – Rotation of the performance curve – Switchover or programming of internal/external set value – Sensor selection via keypad – Programming for ”Filter fault” – Keypad code – K factor entry (The K10-factor can be found in the current lists of our fan line) Technical Data Input Out ProtectionOperating Operating max. class consumption temperature ERA V mA VA °C 02-4000-5E 0...10 10 IP 20 < 10 0 ... +55 179 Roof Extract Fans / Accessories Accessories Universal control device ERA 02 for installation in control cabinets 99 106 Dimensions in mm, Subject to change 166.5 44 max. 105 10.5 159 Instrument panel window Connection diagram °C V mA 1 2 3 E2 4 (+) (–) D+ 24V 24V D2 A1 GND E1 L1 N PE D– GND D1 D3 A2 GND E2 5 °C V mA E1 11 14 12 21 24 22 K1 Line + A 1 Out, 24 V DC 2 Input, Digital 1/2/3 3 Out, Analog 1/2 4 Input, Analog 0-10 V 1/2 5 Contact rating max. 5 A / 250 V AC 180 DATA B GND RS485 A2 2 (Imax=10mA) + A1 1 (Imax=10mA) E2 4 + E1 3 1 Out 0-10 V 2 Out 0-10 V 3 Input 0-10 V 4 Input 0-10 V + K2 Roof Extract Fans / Accessories Accessories Time control module ETG 01 The time control module ETG is for the implementation of time-controlled discharged air systems. With the time switch module ETG all fans with integrated single phase AC motors (1~; 230 V; 50 Hz, 0...7 A) can be controlled. Allocation is via the motor nominal current. The operating intervals can be freely programmed, and if required, the second pre-set speed stage can be changed. Programming the selected weekly cycle is possible by using up to 42 programmable switching points. The system is equipped with automatic changeover between summer and winter times, as well as integrated motor protection for motors with thermal contacts. Technical Data Time switch module ETG for fans with single-phasen-AC motors 230 V; 50 Hz Controlling Nominal current ETG A 01-0018-5Etime 01-0040-5Etime 01-0070-5Etime 1.8 4.0 7.0 300 Dimensions in mm, Subject to change 300 170 ETG 02 181 Roof Extract Fans / Description Description Example of type code 168 Description The type code of every fan is composed as follows. Example: RDM 31-3540-4D-10-.. Special: - 25= Material code (KDM: PPs and PP-GF) - 3G= Fan category “3“ Medium “G“ Index for motor size Motor: - D = 3-phase current - A = 3-phase current (voltage adjustable) - E = single phase current - EC= Brushless-DC-motor with Commutation unit - X = ATEX version N° of poles: - 2 = 2-poles - 4 = 4-poles - 6 = 6-poles - 8 = 8-poles - M = 4/4-poles - N = 6/6-poles - I = 4/6-poles - G = 4/8-poles - K = 6/8-poles - H = 6/12-poles Impeller diameter (nominal 400mm) Connecting diameter (nominal 355mm) Specification - 1 = Standard - 2 = Noise attenuated Impeller geometry - 2 = Type 20 - 3 = Type 30 Drive type - A = External rotor motor - M = IEC standard motor Roof Extract Fans / Description Description Symbol / Unit / Description f Hz Frequency fc Hz Octave band frequency IA/IN- Startin current / Full load current INA Nominal motor current LpAdB A-weighted sound pressure level LWAdB A-weighted sound power level LWA2dB A-weighted casing sound power level LWA3dB A-weighted inlet sound power level LWA8dB A-weighted casing and free discharge sound power level (Outlet side) LWfcdB Sound power level at the octave bands LWfc2dB Casing sound power level at the octave bands LWfc3dB Inlet and duct sound power level at the octave bands (Inlet side) LWfc8dB Casing and free discharge sound power level at the octave bands (Outlet side) LWreldB Relative sound power level LWrel2dB Relative casing sound power level LWrel3dB Relative inlet sound power level (Inlet side) LWrel8dB Relative casing and free discharge sound power level (Outlet side) mkg Weight N1/min Fan speed PekW Power consumption PNkW Nominal motor power t°C Temperature of gas medium um/s Impeller tip speed UV Voltage qVm³/h Volume flow qVNm³/h Nominal volume flow qVmaxm³/h Maximal volume flow qVoptm³/h Volume flow at optimum efficiency gpPa Differential pressure psFPa Effective pressure free discharge (static pressure) r1kg/m³ Density of gas medium at inlet 169 Roof Extract Fans / Description Description Gas media The roof extract units are suitable for the transport of dust-free air and other nonaggressive gases and vapours. The possible min. and max. temperatures of the conveying medium for each fan are given with the specification sheet. Plastic roof fans KDM are corrosion resistant and weather proof. They are designed for extraction of aggressive gases or vapours (e.g. laboratories, suction hoods, galvanic processing etc.). For an order or inquiry it is advisable to state the proposed usage and / or media to be conveyed, so that it can be checked that the materials employed are suitable. Protection The roof fans are equipped with a guard at discharge. The intake side is not equipped with a guard as a standard because usually there are installation parts connected. The fans may only be put into operation if all necessary protection directives are met and effective (Check with operation instructions). The safety devices have to executed and installed according to DIN EN ISO 12100. If the intake of the fan is freely accessible safety devices according to DIN EN ISO 13857 have to be provided. Safety instructions Transport, fitting, electrical connection, start up, and maintenance are to be executed following to the instructions given with the manual and by respecting the actual standards, directives, and safety rules. Fitting instructions verovent roof units are built for fitting to roof-mounted upstands. The fitting level should be horizontal if at all possible. A slope angle of up to 20°, ATEX types up to 5° would be admitted. The roof fans of the lines RDA 31/32 and RDM 31/32 have to be installed in a way that the 2 opposite discharge openings are parallel in line with the roof inclination. Accessories For the intake side, for the installation on roof top and for the extended function of the motor a standardised scope of accessories is available. Specification, technical data, and dimensions are available in the corresponding catalogues. Electrical wiring All roof extract unit are delivered ready for connection. Electrical connection takes place in accordance with the enclosed operating instructions and observing the relevant applicable local regulations and directives. Electrical power supply occurs through the cable duct in the fan base frame to the terminal box. Every fan is accompanied by a connection circuit diagram. You can also find the relevant circuit diagram online under: www.nicotra-gebhardt.com. Explosion-proofed Version (ATEX) Roof fan in explosion proof specification correspond to the EU Directive 94/9/EG (ATEX) category 3G. They are suitable for conveying explosive atmosphere of zone 2 and for installation in zone 2 or in an area which is not under explosion hazard. The maximum conveying temperature is +40 °C. The installation of roof fans on an inclined roof is allowed until an inclination of 5° to vertical. 170 Roof Extract Fans / Description Description Drive types Nicotra Gebhardt external-rotor motors Integrated motors that have proved themselves in practice are used for the drive. Deep groove ball bearings that have been checked to be quiet and maintenance free ensure a long service life. To protect against thermal overload, all motors are equipped with thermal contacts. This thermal overload protection must be effective during operation in order for the factory guarantee to apply in case of damage. Please be sure to study the associated circuit diagram for the fan regarding the technical inclusion of thermal contacts, also available online at www.nicotra-gebhardt.com. IEC standard motors The standard fan drive consists of flanged IEC motors, execution B5, protection class IP 55, heat class F. There is single-speed, multi-speed, and speed controlled motors available. According to their execution the motors are equipped with either PTC thermistors or with thermo contacts as a standard. Only roof fan series „KD“ and „HD“ are not equipped with PTC thermistors or thermo contacts. In connection with a triggering unit, a motor protection unit, or a speed control unit with integrated protection, each fan drive will be protected against thermal overload. This thermal overload protection has to be in place and to be effective during operation in order to make the warranty applying in case of damage. Please respect the instructions of the wiring diagram supplied with every fan. If these instructions are missing they can be down loaded from www.nicotra-gebhardt.com. Brushless-DC-motors with commutation unit Brushless-DC-motors are DC motors that make use of developments in semiconductor technology to attain optimum use of energy, even in partial load operation. With that Brushless-DC-motors provide the drive with the greatest energy efficiency for fans. As the motor is operated as a standard with performance electronics, it is predestined from the start for speed regulation. No other fan drive provides a comparable efficiency in the partial load area. The motors do not have any direct temperature monitoring by thermal contacts or thermistors. Motor protection is via current monitoring contained in the electronic commutation unit. The single-phase supplied commutation unit with variable output voltage and frequency is optimal coordinated with the operation of the Nicotra Gebhardt BrushlessDC-motors. Explosion-proofed Version (ATEX) The use of electronic controllers and inverters for speed control of explosion proofed emotors is non admissible! explosion proofed external-rotor-motors Only proven external rotor motors of protection class IP 44 and insulation class F are used. The motors are equipped with maintenance free closed groove ball bearings lubricated for lifetime. They comply to ignition type EEX e II T3 (increased safety „e“, according to EN 60079-7, EC certification labelled II 2G EEx e II T3) and certified for temperature class T1 to T3. The motors are suitable for operation in explosion hazard areas of zone 2. The fan speed can be reduced by voltage using a transformer for reduction. The feed voltage may not be lower than 115 V. (admitted range 115 V to 400 V). In order to protect the motors against overheating PTC thermistors are provided. The PTC unit has to be connected to a ATEX certified PTC switch labelled Ex II (2)G. explosion proofed IEC Standard motors The drive is realised with flanged standard motors type B5, protection class IP 55 and thermal class F (used to B). They comply to ignition type EEX e II T3 (increased safety „e“, according to EN 60079-7, EC certification labelled II 2G EEx e II T3) and certified for temperature class T1 to T3. In order to maintain the explosion safety level in operation, suitable overcurrent protection has to be provided. 171 Roof Extract Fans / Description Description Performance data The performance curves are obtained using an inlet side test chamber in accordance with ISO 5801 “Industrial fans - Performance testing using standardized airways“. The performance grids show the effective pressure increase psF (Pressure increase obtained from the fan in free-field conditions) as a function of the flow volume qV. Reference media density: r1 = 1.15 kg/m³. 1 = Fan under test 2 = Chamber 3 = Grille 4 = Variable throttle 5 = Auxiliary fan 6 = Honeycomb straightener 7 = Standard intake nozzle 1 2 t1 3 4 5 6 psF 7 ta pa pa qV = f(pa) Roof units are built to tolerances of Class 2 of DIN 24166 “Fans, TechnicalSpecifications”. Hence, the following deviations from the catalogue values are permitted: Flow volume qV ±5 % Pressure increase psF ±5 % Absorbed power Pe +8 % Sounds Measurement and evaluation of noise levels are in accordance with DIN 45635-38 „Sound measurements on machines; fans“. Duct method – inlet side The duct measurement method is described in DIN EN ISO 5136.The sound power emanating from the roof unit into the inlet-side duct is measured. Envelope method – discharge side The envelope method is described in DIN 45635-1 and -38 (BS 848 Part 2). A cuboid envelope is assumed at a fixed distance surrounding the roof unit, with measuring points lying on its planes. 1 = Soundabsorbing room 2 = Microphones for envelopemeasurement 3 = Fan under test 4 = Measuring duct 5 = Microphone with attachmentfor duct measurement 6 = Soundabsorbing end cover 7 = Variable throttle 1 2 3 5 4 Lp3/4 Lp7/8 pa 172 6 7 Roof Extract Fans / Description Description Sounds At the fan curves the emission value of the A-weighted sound power level LWA is given and are valid for both inlet (LWA3) and discharge (LWA8). For the fans RDA/RDM, the sound values of the integrated discharge dampers are considered. For more exact calculations when determining the required attenuation, the sound power level in the octave bands is important. The relative sound power levels at intake and discharge, at various duty points, can be read from the corresponding tables for each fan range. LWfc = LWA + LWrel The sound power level is the specific and objective noise parameter for every machine. Only with these data sound comparisons between machines can be made. For this reason only sound power level data are shown. For fans classified to tolerance class 2 according to DIN 24166 a maximum deviation of the sound power level value of 4 dB is specified. a b 10 L r 30 dB 20 r 1 5 m 10 Often the sound pressure value at a determined distance from a fan is required. In fact this value depends from surrounding conditions (reflections, absorption, sound propagation possibilities). The sound pressure level at a distance of 4 meters can for instance be lower of 16 to 23 dB to the corresponding sound power level. The A-weighted sound pressure value LpA to be expected at a certain distance from the fan can be evaluated approximately with the adjacent diagram. The diagram shows 2 curves covering the field where the relative sound power level data at various distances usually is situated. For a sound propagation in a hemisphere shape and without reflections the curve “a” can be used. For more uncertain conditions – usual in practice – the use of the curve “b” is recommended. The determination of the sound pressure at fan intake can only be made if the local acoustic properties are known. (see z.B. VDI-Richtlinie 2081). 173 Roof Extract Fans / Description Description Quality management system DIN EN ISO 9001 Nicotra Gebhardt quality is the result of rigorously pursuing business policy goals, which specify that Nicotra Gebhardt products must display properties and characteristics that are clearly above average when compared to similar products. This maxim, which has applied since the company was founded, lead in April 1985 to the auditing and certification of the existing quality assurance system. In subsequent years, it was adjusted to comply with changed international and European standards. Modern production procedures, monitored by our quality management system, ensure a high level of repeatability in manufacturing. The tight tolerances allow high levels of data security for our products. Information on machine safety The fans contained in this catalogue are not machines in the spirit of EC Machinery Directive and receive a Declaration of Incorporation . With reference to the building product directive they are provided with a CE symbol and associated declaration of conformity. The assessment of danger arising from the fan and requisite safety measures occurred resulting from the VDMA (Association of German Mechanical Engineering Institutions) standard sheet 24167: Fans; safety requirements. The Operating Instructions give which safety measures are still necessary on assembly to ensure that the fans comply with the EC Machinery Directive 2006/42/EG. Notes on EMV Directive Nicotra Gebhardt Roof Fans with EC Motors and the Electronic Commutation Unit necessary for their operation comply in their construction with the EMV Directive EMV 2004/108/EWG. The Operating Instructions give the appropriate measures to be carried out for installation which are in keeping with the conditions of the EMV Directive. The observance of the EMV Directive can only be maintained for this product if it is directly connected to the mains. If it is incorporated as part of another installation with other components e.g. those subject to engineering regulations or operated in a manner not in accordance with the Operating Instructions, it is the manufacturer or operator of that installation who is responsible for the observance of the EMV Directive. Notes on catalogue data We reserve the right to change the dimensions and technical data contained in this catalogue in the event that our product is further developed. All details correspond to the version on the date of printing. Service Our mobile service offer for intervention on the site in combination with our standby team at the workshop will assure an efficient support to all requirements you may have. Make just a phone call and our service team will help you to solve your problem fast and reliably. Service Hotline Phone Fax +49 (0)7942 / 101-384 +49 (0)7942 / 101-385 The part shop offered by Nicotra Gebhardt The easy-to-handle online shop enables you to identify instantly every spare part. A graphically supported list makes your selection easy. So an online service is available which will help you to make your repair as simple as possible. www.nicotra-gebhardt.com 174 Notes 175 nicotra-gebhardt.com AUSTRALIA 65 Yale Drive, Epping, VIC 3076 Phone +61 3 9017 5333 Fax +61 3 8401 3969 E-mail [email protected] BELGIUM Haeghensgoed, 13 - 00/01 9270 Laarne Phone +32 (0)9-336-00-01 Fax +32 (0)9-336-00-05 E-mail [email protected] CHINA 88 Tai‘An Road, XinQiao, ShiJi, Panyu Guangzhou 511450 PR CHINA Phone +86 (0)20-2293 5700 Fax +86 (0)20-2293 5701 E-mail [email protected] FRANCE Leader's Park Bat A1 3 chemin des Cytises 69340 Francheville Phone +33 (0)4 72 79 01 20 Fax +33 (0)4 72 79 01 21 E-mail [email protected] GERMANY Gebhardtstraße 19-25 74638 Waldenburg Phone +49 (0)7942 101 0 Fax +49 (0)7942 101 170 E-mail [email protected] GREAT BRITAIN Unit D, Rail Mill Way Parkgate Business Park Rotherham South Yorkshire S62 6JQ Phone +044 01709-780760 Fax +044 01709-780762 E-mail [email protected] INDIA Plot no 28F & 29, Sector-31,Kasna, Greater Noida-201 308 U.P (India) Phone +91 120 4783400 Phone +91 22 65702056 (Mumbai) Phone +91 80 25727830 (Bangalore) E-mail [email protected] ITALY Via Modena, 18 24040 Zingonia (BG) Phone +39 035 873 111 Fax +39 035 884 319 E-mail [email protected] MALAYSIA Lot 1799, Jalan Balakong Taman Perindustrian Bukit Belimbing 43300 Seri Kembangan Selangor Phone +603 8961-2588 Fax +603 8961-8337 E-mail [email protected] SPAIN Ctra. Alcalá-Villar del Olmo, Km. 2,830 28810 Villalbilla-Madrid Phone +34 918-846110 Fax +34 918-859450 E-mail [email protected] SINGAPORE 3, Science Park Drive, # 04-07, The Franklin Singapore Science Park 1 Singapore 118223 Phone +65 6265 1522 Fax +65 6265 2400 E-mail [email protected] Nicotra Gebhardt Germany Nicotra Gebhardt Italy Nicotra Gebhardt GmbH Gebhardtstraße 19-25 74638 Waldenburg Germany Phone +49 (0)7942 101 0 Fax +49 (0)7942 101 170 E-Mail [email protected] Nicotra Gebhardt S.p.A Via Modena, 18 24040 Zingonia (BG) Italy Phone +39 035 873 111 Fax +39 035 884 319 E-Mail [email protected] SWEDEN Kraketorpsgatan 30 43153 Mölndal Phone 0046 101-302600 Fax 0046 31-878590 E-mail [email protected] THAILAND 6/29 Soi Suksawadi 2, Moo 4, Suksawadi Road, Kwang Jomthong, Khet Jomthong, Bangkok 10150 Phone +662 476-1823-6 Fax +662 476-1827 E-mail [email protected] UNITED STATES PO BOX 900921 Sandy, Utah 84090 Phone 001(801) 733-0248 Fax 001(801) 315-9400 Mobile 001(801) 682 0898 E-mail [email protected] http://www.gebhardtfans.com/ EN-TD3-REF-5 – PDF2-January2014 Nicotra Gebhardt worldwide