NOTE OPERATIVE DI RELEASE Acucobol Runtime per Windows

Transcript

NOTE OPERATIVE DI RELEASE Acucobol Runtime per Windows
NOTE OPERATIVE DI RELEASE
SPEDIZIONE
Applicativo:
Acucobol Runtime per
Windows
Oggetto: Rilascio versione COMPLETA
Versione: 8.1.2-20110100
Data di rilascio: 28.02.2011
CONFIGURAZIONE ED INSTALLAZIONE AMBIENTE WINDOWS
Requisiti
S.O. Windows:

XP Professional

2003 Server

Vista Business

2008 Server

Seven
Interfaccia:
 SysInt/W 20110100 o
Superiore
Il modulo può essere installato in diverse modalità a seconda di
come viene distribuito :
1. Modulo autoesplodente “autoinst” :
 Cliccare sul bottone “installa”
2. CDROM applicativi TeamCD :
 Seguire la procedura standard di installazione
da applicativo TeamCD
3. File salvati in una cartella o cdrom :
 Eseguire il programma “install.exe”
Per verificare se l’installazione ha avuto un buon esito si possono
eseguire le seguenti operazioni:
1. Dal menù principale scegliere “Setup…”
2. Cliccare “Impostazioni menu” nel sottomenù che verrà
visualizzato
3. Scegliere “Si”
4. Premere il pulsante “Test Runtime ACU Cobol”
Note operative release
1
NOTE OPERATIVE DI RELEASE
AVVERTENZE

Gli eseguibili in ambiente SysInt vengono installati nel direttorio $SYSINT/acucobol

Da questa versione non sarà più supportato l’ambiente AcuServer (fare riferimento alla circolare
2010.02.32 Software Partner TeamSystem Pesaro, 15 Novembre 2010)
Note operative release
2
FAQ
RISPOSTE A DOMANDE FREQUENTI
Moduli Acucorp
Risposte a domande frequenti
Moduli acucorp
FAQ
INDICE
1 Runtime................................................................................................................................................... 3
2 Acurcl/Acuconnect................................................................................................................................ 14
3 Acuserver .............................................................................................................................................. 17
FAQ
2
Risposte a domande frequenti
Moduli acucorp
FAQ
1 Runtime
Acucobol Runtime
Descrizione
Versione
Win
Unix
Quesito
Come devo impostare i permessi in ambiente Windows 2003 per il
corretto funzionamento degli applicativi TeamSystem?
Risposta
Dai test eseguiti si è rilevato quanto segue:
- La sicurezza di Windows 2003 risulta essere più restrittiva delle
precedenti release di Windows.
- In ambiente di rete la presenza di postazioni client Windows 9x
potrebbe causare un degrado delle prestazioni.
Da tali considerazioni è consigliato operare nel seguente modo:
• Definire una risorsa (partizione, disco) dove tutti gli utenti che fanno
uso delle applicazioni TeamSystem (GECOM/GAMMA Plus) abbiano il
permesso di FULLACCESS.
• Dove è possibile è preferibile aggiornare le postazioni client a
Windows 2000 o superiore.
6.0.0
6.1.0
7.0.0
7.2.1
7.2.2
X
In Windows 2003 i permessi di default per i dischi fissi risultano essere
piuttosto restrittivi, impostati in modo da poter essere rivisitati
dall'amministratore di sistema. Dopo la creazione di un unità disco, i
permessi di default sono di lettura ed esecuzione per gli utenti del
gruppo "USERS", mentre il controllo completo è associato solo ed
esclusivamente al gruppo "Administrators".
Per far girare correttamente gli applicativi TeamSystem, l'utente deve
avere accesso completo al disco fisso dove sono locati i file degli
applicativi stessi. Il gruppo di cui fanno parte gli utenti che utilizzano gli
applicativi deve quindi avere permessi “FULLACCESS” come il gruppo
“Administrators”.
Una procedura consigliabile potrebbe essere quella di creare un gruppo
“Teamsystem” con i permessi necessari.
IMPORTANTE
Se un utente appartiene a due o più gruppi varranno sempre le
condizioni più restrittive nel caso sia indicato “Nega” su alcuni
permessi. Quindi per poter utilizzare gli applicativi TeamSystem i
gruppi di cui fa parte devono avere tutti permessi “FULL
ACCESS” (o al massimo permessi “FULL ACCESS” su un gruppo
e non negati sugli altri). Se la risorsa utilizzata per gli applicativi
fosse il disco di sistema tale procedura causa problemi di
sicurezza, di conseguenza si consiglia di installare in un disco
logico a se stante.
Esempio per definire correttamente i permessi:
FAQ
3
Risposte a domande frequenti
Moduli acucorp
FAQ
Acucobol Runtime
Descrizione
Versione
Win
Unix
1) Creare un gruppo “Teamsystem” di cui facciano parte tutti gli utenti
che utilizzano gli applicativi.
2) Codividere la risorsa (disco/partizione) , andare su “Start” -> “Risorse
del computer” selezionare con il tasto destro del mouse l’unità disco
interessata e scegliere la voce “Proprietà”
3) Nella finestra che appare selezionare il folder “Condivisione”
4) Nella finestra che appare selezionare “Consenti” su tutte le voci e
premere “OK”.
5) Si torna nella finestra delle “Proprietà” dell’unità disco; selezionare il
FAQ
4
Risposte a domande frequenti
Moduli acucorp
FAQ
Acucobol Runtime
Descrizione
Versione
Win
Unix
folder “Protezione” e premere “Aggiungi” per aggiungere il gruppo
“Teamsystem”.
6) Si apre una nuova finestra. Nella casella di testo è possibile scrivere
direttamente il nome del gruppo, ad esempio “Teamsystem” (in questo
caso andare al punto 8). In alternativa, per
selezionare il gruppo da un elenco, selezionare “Avanzate..”.
7) Se si è scelto di cercare il gruppo da un elenco di quelli disponibili,
utilizzare il tasto “Trova” della finestra relativa selezionare il gruppo
interessato e premere “OK”.
8) Premere “OK” per aggiungere il gruppo.
FAQ
5
Risposte a domande frequenti
Moduli acucorp
FAQ
Acucobol Runtime
Descrizione
Versione
Win
Unix
9) Selezionare il gruppo “Teamsystem”, selezionare tutti i campi relativi
alla colonna “Consenti” e premere l tasto “OK”.
ANNOTAZIONI
Da prove effettuate, in presenza di Acuserver, l’unità disco che
contiene gli archivi deve essere accessibile con permessi
“FULLACCESS” dal gruppo “everyone”.
Nota Bene:
La configurazione che abbiamo consigliato è la più semplice possibile
per avere un corretto funzionamento, si noti però che è anche una
configurazione poco sicura concedendo a tutti gli utenti accesso
completo alla risorsa condivisa. E’ possibile con le dovute conoscenze
sistemistiche realizzare una rete maggiormente
sicura e parimenti funzionante.
FAQ
6
Risposte a domande frequenti
Moduli acucorp
FAQ
Acucobol Runtime
Descrizione
Versione
Win
Unix
In ambiente SysIntWeb o Acuserver, se si devono applicare
politiche restrittive la soluzione è dare permessi di "Full
Controll" all'utente "SYSTEM", dato che i servizi (acurcl ed
acuserver) girano come utente SYSTEM
e permessi di accesso completo agli utenti normali sui direttori
archivi.
5.2.1
Quesito
Posso effettuare test di funzionaita’ dei moduli acucorp presenti
nell’ambiente in cui si sta operando?
Risposta
Per effettuare test mirati per l’ambiente su cui si opera è stata
realizzata l’utility ACUTEST. I test a disposizione si dividono nelle
seguenti categorie:
• test prestazionali grafici
• test prestazionali su archivi
• test di connessione con AcuServer
6.0.0
6.1.0
X
7.0.0
7.2.1
7.2.2
Test prestazionali grafici
Attraverso questi test è possibile constatare il funzionamento di colori,
oggetti grafici statici (label), tabcontrol, check-box, …Alcuni di essi
permettono di calcolarne i tempi.
Test di connessione ACUSERVER
Permettono di verificare se la connessione con AcuServer è
funzionante.
Test prestazionali su archivi
Eseguono differenti operazioni su file. Essi operano sia in modalità
multiutenza, che monoutenza, gestendo il lock sul file o sul singolo
record.
FAQ
7
Risposte a domande frequenti
Moduli acucorp
FAQ
Acucobol Runtime
Descrizione
Versione
Win
Unix
5.2.1
Quesito
Su un sistema linux non riesco a riavviare il servizio acushare
Risposta
Verificare se ci sono delle shared memory non rilasciate.
Da console come utente root:
6.0.0
- Per visualizzare tutte le info utilizzare il comando
ipcs -a
- Tramite il comando ipcrm rimuovere la shared memory usata
ipcrm shm xxxxxxx
e riavviare acushare
- Se si hanno ancora problemi rimuovere anche la coda dei messaggi
ipcrm msg xxxxx
e riavviare acushare
6.1.0
X
7.0.0
7.2.1
7.2.2
Quesito
Sui sistemi operativi Linux/Unix supportati è possibile visualizzare la
versione del rilascio TeamSystem relativa alla Runtime installata?
Risposta
Si, tramite il comando RUNTIME (maiuscolo).
Quesito
In ambiente SunOS sparc 5.6 si verificano errori 94,10 (“Too many files
open by the current process. “)
Risposta
Modificare i parametri di sistema operativo riportati nel file /etc/system
7.0.0
7.2.1
X
7.2.2
6.0.0
6.1.0
7.0.0
X
7.2.1
Impostando i seguenti:
set rlim_fd_cur = 1024
set rlim_fd_max = 8192
7.2.2
Riavviare il sistema.
FAQ
8
Risposte a domande frequenti
Moduli acucorp
FAQ
Acucobol Runtime
Descrizione
Versione
Win
Unix
Quesito
Si verifica un errore ACUCOBOL-GT Runtime “xx,yy”.
Dove posso trovare informazioni corrispondenti al codice di
errore visualizzato?
Risposta
Segue una tabella sintentica degli errori Acucobol Runtime.
Per maggiori dettagli fare riferimento alla documentazione
Acucorp.
Cod.
00
Operation successful.
02
The current key of reference in the record just read is
duplicated in the next record. (read next)
02
The operation added a duplicate key to the file where
duplicates were allowed. (write, rewrite)
00
Optional file missing. If the open mode is I-O or
EXTEND, then the file has been created. This is also
returned by DELETE FILE if the file is not found. (open,
delete file)
00
A CLOSE UNIT/REEL statement was executed for a file
on a non-reel medium. The operation was successful.
0M
The operation was successful, but some optional
feature was not used. For example, if you opened a file
that specified an alternate collating sequence, but the
host file system did not support that feature, then the
open would succeed, but it would return this status.
10
End of file. (read next)
00
A sequential READ statement was attempted for a
relative file, and the number of digits in the relative
record number is larger than the size of the relative key
data item. (read next)
21
Primary key was written out of sequence, or the primary
key on a rewrite does not match the last record read.
This error occurs only for an indexed file open with the
sequential access mode. (write, rewrite)
22
Duplicate key found but not allowed. (write, rewrite)
5.2.1
6.0.0
6.1.0
X
7.0.0
X
7.2.1
7.2.2
Descrizione
FAQ
9
Risposte a domande frequenti
Moduli acucorp
FAQ
Acucobol Runtime
Descrizione
Versione
Win
Unix
23
Record not found.
24
Disk full for relative or indexed file. (write)
00
A sequential WRITE statement was executed for a
relative file, and the number of digits in the relative
record number was larger than the size of the relative
key data item. (write)
30, xx
Permanent error. This is any error not otherwise
described.
The secondary code value is set to the host system's
status value that caused the error. See your operating
system user manual for an explanation, and C$RERR in
Appendix I.
34
Disk full for sequential file or sort file. (write, sort)
94, 20
File not found. (open, sort)
95, 01
The file being opened is not on a mass-storage device
which is required for the file type or the requested open
mode. (open)
95, 02
Attempt to open a sequential file with fixed-length
records as a Windows spool file.
90, 07
User does not have appropriate access permissions to
the file. (open)
95, 08
Attempt to open a print file for INPUT. (open)
95, 09
Attempt to open a sequential file for I/O and that file has
automatic trailing space removal specified. (open)
95, 99
A Windows or Windows NT runtime that is not networkenabled tried to access a file on a remote machine.
93, 03
File previously closed with LOCK by this run unit. (open)
94, xx
Existing file conflicts with the COBOL description of the
file. (open)
The secondary error code may have any of these values:
01 - mismatch found but exact cause unknown (this
FAQ
10
Risposte a domande frequenti
Moduli acucorp
FAQ
Acucobol Runtime
Descrizione
Versione
Win
Unix
status is returned by the host file system)
02 - mismatch found in file's maximum record size
03 - mismatch found in file's minimum record size
04 - mismatch found in the number of keys in the file
05 - mismatch found in primary key description
06 - mismatch found in first alternate key description
07 - mismatch found in second alternate key description
The list continues in this manner for each alternate key.
92
File is already open. (open)
91
File not open. (close)
91
File not open. (unlock)
90, 02
No current record defined for a sequential access mode
file. (rewrite, delete)
97
Record size changed. The record being rewritten is a
different size from the one existing in the file, and the
file's organization does not allow this. (rewrite)
This status code can also occur if the record is too large
or too small according to the RECORD CONTAINS
clause for the file. (write, rewrite)
96
No current record. This usually occurs when the
previous operation on the file was a START that failed,
leaving the record pointer undefined. (read next)
90, 01
File not open for input or I-O. (read, start)
91, 02
File not open. (read, start)
90, 01
A file that is defined to be access mode sequential is
open for I-O, or the file is open for INPUT only. (write)
91, 02
File not open. (write)
90, 01
File not open for I-O. (rewrite, delete)
FAQ
11
Risposte a domande frequenti
Moduli acucorp
FAQ
Acucobol Runtime
Descrizione
Versione
Win
Unix
91, 02
File not open. (rewrite, delete)
93
File locked by another user. (open)
94, 10
Too many files open by the current process. (open)
94, 62
One of the LINAGE values for this file is illegal or out of
range. (open, write)
94, 62
Key not specified (specifying a table whose size is zero)
in a SORT or MERGE statement
98, xx
Indexed file corrupt. An internal error has been detected
in the indexed file. The secondary status code contains
the internal error number. The file should be
reconstructed with the appropriate utility.
99
Record locked by another user.
9A
Inadequate memory for operation. This most commonly
occurs for the SORT verb, which requires at least 64K
bytes of free space. (any)
9B
The requested operation is not supported by the host
operating system. For example, a deferred file system
initialization failed, or a READ PREVIOUS verb was
executed and the host file system does not have the
ability to process files in reverse order. (any)
If you are using AcuXML, this error results when the
program tries to open a file EXTEND or I-O. With
AcuXML, programs are able to open files INPUT or
OUTPUT only.
9C
There are no entries left in one of the lock tables. The
secondary error code indicates which table is full:
01 - operating system lock table
02 - internal global lock table (see the MAX_LOCKS
configuration variable)
03 - internal per-file lock table (see the
LOCKS_PER_FILE configuration variable)
9D, xx
This indicates an internal error defined by the host file
system. The "xx" is the host system's error value. This is
similar to error "30", except that "xx" is specific to the host
file system instead of the host operating system. For
FAQ
12
Risposte a domande frequenti
Moduli acucorp
FAQ
Acucobol Runtime
Descrizione
Versione
Win
Unix
example:
02 - In Acu4GL or AcuXML, 9D,02 indicates that an XFD
file is corrupt. This could be the result of a parsing error.
03 - In Acu4GL or AcuXML, 9D,03 indicates that an XFD
file is missing. This could be the result of a parsing
error.
05 - In AcuXML, 9D,05 indicates that there was an XFD
parsing error, so AcuXML was unable to read a record.
Refer to the specific Acucorp product documentation for
more details on the host file system's error codes.
9E, xx
This indicates an error occurred in the transaction
system. The exact nature of the error is shown by the
contents of TRANSACTION-STATUS. For more
information, see section "Transaction Error Codes."
9Z
This indicates that you are executing the program with a
runtime that has a restriction on the number of records it
can process. You have exceeded the record limit.
FAQ
13
Risposte a domande frequenti
Moduli acucorp
FAQ
2 Acurcl/Acuconnect
Acucobol Acurcl
Descrizione
Versione
Win
Unix
6.1.0
Quesito
In ambienti Windows 2003 con Acurcl si verificano ‘Errori 93’
Risposta
Il problema si presenta nel caso in cui l'amministratore di sistema
non da i permessi "Full Control" sulle cartelle degli archivi a tutti gli
utenti. Se si devono applicare politiche restrittive la soluzione è dare
permessi di "Full Controll" all'utente "SYSTEM" (dato che il servizio
Acurcl gira come utente SYSTEM) e permessi di accesso completo
agli utenti normali sui direttori archivi.
Per maggiori dettagli sulla corretta impostazione dei permessi sul
server Windows fare riferimento alla faq relativa nella sezione
Acucobol Runtime del presente documento.
Quesito
Dopo aver effettuato il login in SysIntWeb non si riesce ad eseguire
alcun applicativo.
Risposta
Nel caso in cui non si riuscissero ad eseguire gli applicativi, dopo
aver effettuato il login in SysIntWeb, una delle cose da verificare sul
server riguarda i permessi dei file acurcl.acc ed acurcl.vix (nel
direttorio $SYSINT\acucobol\) che devono avere, su sistemi operativi
Windows, il controllo completo da parte degli utenti SYSTEM ed
Administrator. Selezionando i due file con il tasto destro, verificare
che nelle proprietà di protezione tali permessi siano impostati.
Sui sistemi Linux/Unix tali file devono avere chmod 600 e chown 0:0
(utente root).
Quesito
Eseguendo un comando applicativo da SysIntWeb ho l'errore
seguente:
ACUCOBOL-GT Thin Client "Connection failed. Incompatible server
version"
Risposta
Questo errore si verifica se presente SysIntWeb versione precedente
alla 20050300, che non gestisce il file degli accessi nel formato xml.
Per risolvere aggiornare SysIntWeb a versione 20050300 o superiore.
Quesito
Eseguendo un comando applicativo da SysIntWeb ho l'errore
seguente:
ACUCOBOL-GT Thin Client "Connection failed. Alias does not exist"
Risposta
Questo errore viene dato quando il file acurcl.ini e' corrotto (es. a zero
byte). Tale condizione si verifica ad esempio se si retrocede la
versione acurcl 700 alla 610. L'eseguibile acurcl legge il file acurcl.ini
(in formato xml) e lo azzera! Per risolvere reinstallare SysIntWeb.
7.0.0
X
7.2.1
7.2.2
6.1.0
7.0.0
X
X
7.2.1
7.2.2
7.0.0
6.1.0
X
X
X
X
FAQ
14
Risposte a domande frequenti
Moduli acucorp
FAQ
Acucobol Acurcl
Descrizione
Versione
Win
Unix
Quesito
In SysIntWeb server Windows su impianti con elevato numero di
processi concorrenti, eseguendo un programma ottengo il seguente
errore:
Risposta
Il problema potrebbe essere legato ad una limitazione del numero
massimo di processi concorrenti gestiti del sistema operativo.
Dal menu di SysInt sul server verificare con il comando
“ACURCL” ---> “Informazioni di stato Acurcl”
se ci sono molti processi attivi.
6.0.0
6.1.0
7.0.0
X
7.2.1
7.2.2
FAQ
15
Risposte a domande frequenti
Moduli acucorp
FAQ
Acucobol Acurcl
Descrizione
Versione
Win
Unix
In questo caso modificare la chiave:
HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control\Session
Manager\SubSystems
Il parametro da modificare e' "Windows".
Il valore di default e' il seguente:
%SystemRoot%\system32\csrss.exe ObjectDirectory=\Windows
SharedSection=1024,3072,512 Windows=On
SubSystemType=Windows
ServerDll=basesrv,1 ServerDll=winsrv:UserServerDllInitialization,3
ServerDll=winsrv:ConServerDllInitialization,2 ProfileControl=Off
MaxRequestThreads=16
Sostituire il valore 512 con 1024 e riavviare il sistema.
Se il problema persiste ripristinare il valore originale e riavviare il
sistema perche' tale modifica potrebbe influenzare altri servizi.
FAQ
16
Risposte a domande frequenti
Moduli acucorp
FAQ
3 Acuserver
Acucobol
Acuserver
Versione
Win
5.2.1
Descrizione
Unix
Quesito
In ambienti Windows 2003 con acuserver si verificano ‘Errori 93’
Risposta
Il problema si presenta nel caso in cui l'amministratore di sistema
non da i permessi "Full Control" sulle cartelle degli archivi a tutti gli
utenti. Se si devono applicare politiche restrittive la soluzione è dare
permessi di "Full Controll" all'utente "SYSTEM" (dato che il servizio
acuserver gira come utente SYSTEM) e permessi di accesso
completo agli utenti normali sui direttori archivi.
Per maggiori dettagli sulla corretta impostazione dei permessi sul
server Windows fare riferimento alla faq relativa nella sezione
Acucobol Runtime del presente documento.
6.0.0
6.1.0
X
7.0.0
7.2.1
7.2.2
FAQ
17