Waterline - CasaleInforma
Transcript
Waterline - CasaleInforma
Croce Rossa Italiana – Ospedale di Baghdad (Iraq) Italian Red Cross Hospital – Baghdad (Iraq) Rapporto Tecnico Technical Report Baghdad 31-10-2004 Rapporto n°: CRI-BGD 04-004 Qualità dell’acqua potabile prodotta sull’impianto Waterline presso l’ospedale CRI di Baghdad dopo la sostituzione del filtro a carbone. Quality of drinking water produced on the Waterline plant placed in the Red Cross Hospital in Baghdad after the replacement of the carbon filter. Autori (Authors): Cesar Hermez Dana Honer Mustafa Samir Abdul Wahid Giuseppe Bolzoni Ringraziamenti Un particolare ringraziamento al CAP Gestione (ex Consorzio per l’Acqua Potabile) di Milano per la collaborazione analitica. In modo particolare si ringraziano il Dr. Peterlongo, il Signor Sverzellati e il personale del laboratorio CAP Gestione che ha generato i dati analitici utilizzati in questo rapporto. Thanks Particular thanks to the CAP Gestione (ex Consorzio per l’Acqua Potabile) of Milan for the analytical support. In particular, we would like to thanks Dr. Peterlongo, Mr. Sverzellati and the CAP Gestione technical people who has generated the analytical results used to prepare this report. Sommario Il filtro a carboni attivi, è utilizzato sugli impianti di trattamento dell’acqua potabile per trattenere migliaia di contaminanti organici presenti nell’acqua da trattare. Quando quest’ultima passa attraverso i granuli del filtro a carbone rallenta la sua velocità permettendo al carbone di legare e rimuovere dall’acqua contaminanti quali tossine, pesticidi, trialometani, cloro attivo, sapori ed odori sgradevoli, ecc. Le moderne tecniche analitiche disponibili, sono in grado di determinare la presenza di questi contaminanti dando la possibilità di misurare la qualità dell’acqua potabile prodotta. L’analisi del livello di alcuni contaminanti presenti nell’acqua prima e dopo il trattamento sul filtro a carbone, ci permettono di determinarne l’efficienza del filtro e di decidere quando è necessario sostituire il carbone in esso contenuto. Nell’acquedotto di Baghdad, l’acqua potabile è disinfettata con sodio ipoclorito; la reazione del cloro libero con le sostanze organiche presenti, genera la formazione di quantità considerevoli di trialometani la cui analisi può essere utilizzata come tracciante per verificare l’efficienza del filtro a carboni attivi presente sull’impianto Waterline. Summary Activated carbon filter is used in the drinking water treatment plant to bond thousands of the organic chemical compounds present in the water as contaminants. When water passes through the carbon filter, it is forced to slow down and increase the contact time with the carbon granules, allowing the carbon bonding to take place to remove the chemical pollutants like toxins, pesticides, Trihalometanes, chlorine, bad tastes, odors, etc. Modern analytical techniques are able to detect the presence of these contaminants checking the quality of the drinking water produced. The determination of the level of some contaminants present in the water before and after the treatment on the carbon filter allow us to detect the efficiency of the filter and when it is necessary to replace its content. In the Baghdad aqueduct, drinking water is disinfected with sodium hypochlorite; high level of tryhalometanes generated from the reaction of available chlorine with the organic compounds present in the water can be easily used as tracers to detect the efficiency of the carbon filter present on the Waterline plant. Rapporto Premessa La Croce Rossa Italiana dispone, presso il proprio ospedale situato all’interno del Medical City Center di Baghdad, di un impianto per il trattamento e potabilizzazione dell’acqua. Tale acqua viene prelevata dalla rete dell’acquedotto cittadino e trattata ulteriormente per garantirne la disinfezione e per migliorarne le qualità organolettiche. L’eccesso di cloro attivo, contaminanti organici, cattivi odori, cattivi sapori e prodotti secondari generati durante la fase di ossidazione del processo di trattamento, vengono rimossi dall’acqua con un filtro a carboni attivi. Prima del confezionamento, un basso livello di cloro attivo (circa 0.2 ppm) viene dosato per garantire la disinfezione dell’acqua durante la sua distribuzione. Total THMs Una delle caratteristiche più importanti dell’acqua distribuita dall’acquedotto ITALIAN RED CROSS HOSPITAL della città di Baghdad è la presenza di Total trihalometanes content in Baghdad quantità significative di trialometani. drinking water Questi contaminanti vengono generati from aqueduct and after carbon filter treatment on durante la fase di ossidazione per la the Red Cross waterline mobile plant reazione tra l’eccesso di ipoclorito e i ppb materiali organici che sono 90 naturalmente presenti nell’acqua 80 potabile. Essi sono composti alogenati 70 e possono essere facilmente rimossi dall’acqua per mezzo di un filtro a 60 carbone. 50 Per questo motivo, i trialometani 40 MaxMax limitlimit European possono essere facilmente utilizzati - ItalianLegislation Legislation 30 per verificare l’efficienza del filtro a 20 carbone presente sull’impianto 10 Waterline. Determinando la presenza e il livello di 0 questi composti, prima e dopo il filtro Feb.-2004 Apr.-2004 May-04 Jul.-04 Sep.-04 a carbone, è possibile determinarne Baghdad Aqueduct Waterline l’efficienza e, quando necessario, rinnovare il carbone esausto con un letto nuovo. Picture 1 Introduction A drinking water treatment plant is available in the Italian Red Cross Hospital in Baghdad. Treated water is taken directly from the Baghdad aqueduct and reworked to guarantee the disinfection and to improve its organolectic properties. The excess of active chlorine, organic contaminants, bad odors, bad taste and by products generated during the oxidation phase of the water treatment, are removed from the water using a carbon filter. Just before filling, a low level of available chlorine (nearly 0.2 ppm) is dosed to guarantee the disinfection during the distribution of packed water. One of the main characteristics of the Baghdad drinking water is the presence of significant amount of contaminants named Tryhalomethanes (THMs). These contaminants are generated during the oxidation phase of the drinking water with sodium hypochlorite in presence of the organic material naturally available in water. They can be easily removed flushing the water through a carbon filter. For this reason, THMs level can be easily used to verify the efficiency of the carbon filter. Detecting the level of these compounds before and after the filter, it is possible to understand when it is necessary to replace the exhausted carbon with a new one. Risultati analitici I risultati analitici dettagliati, relativi al contenuto dei trialometani, prima e dopo il trattamento dell’acqua, sono riportati nei grafici sottostanti e nelle tabelle alla pagina seguente. I risultati sono espressi in microgrammi/litro (µg/l). Il grafico con l’andamento dei trialometani totali è riportato nella pagina del sommario. Il limite per i THMs fissato dalla legislazione Europea è di 30 µg/l. THMs in drinking water of Baghdad aqueduct and after the Red Cross Waterline at different fluxes (litres/hour) Before replacement of the carbon filter Sampling of 03-09-2004 micrograms per litre 60 50 40 30 20 10 0 Baghdad aqueduct 1500l/h 2500 l/h Chloroform DiChl.Br.Methane Bromoform Totali THM 3500 l/h Chl.diBr.Methane Picture 2 THMs in drinking water of Baghdad aqueduct and after the Red Cross Waterline at different fluxes (litres/hour) After replacement of the carbon filter Sampling of 17-09-2004 micrograms per litre 60 50 40 30 20 10 0 Picture 3 Baghdad After aqueduct Carbon 1500l/h 2500 l/h Chloroform DiChl.Br.Methane Bromoform Total THMs 3500 l/h Chl.diBr.Methane Analytical results Detailed analytical results about the trialomethanes content, before and after water treatment, are reported in the pictures 1 & 2 of the previous page and in the following tables: Baghdad Aqueduct Type of contaminant Chloroform diChloro-Bromo Methane Chloro-diBromo Methane Bromoform February 2004 19 23 25 8 April 2004 May 2004 19 18 18 4 July 2004 1 19 26 9 24 24 26 8 September 2004 11 20 26 8 After Waterline tratment Type of contaminant Chloroform diChloro-Bromo Methane Chloro-diBromo Methane Bromoform February 2004 1 1 1 1 April 2004 May 2004 2 1 1 1 1 4 4 4 July 2004 7 5 2 0 End September 2004 Not detectable after the filter The picture in the summary page shows the tendency of the tryhalomethanes (THMs) content before and after the treatment on the carbon filter. The maximum limit allowed by the European legislation is 30 µg/l (dotted line). The red line is the THMs content in the Baghdad drinking water and the blue line is the THMs content after treatment on the Waterline. Commenti e conclusioni Dal grafico riportato nella premessa si può chiaramente vedere che la qualità dell’acqua all’uscita del filtro a carbone era peggiorata negli ultimi mesi per cui si rendeva necessario sostituire il carbone con un letto nuovo. Il livello di THM totali, anche dopo il trattamento era superiore al limite di legge andando con le portate di acqua tra i 2500 e i 3500 litri/ora ed era praticamente paragonabile alla quantità determinata prima del filtro (grafico 2). La sostituzione del carbone è stata eseguita a metà settembre dagli operatori del Waterline presenti sull’impianto con 300 Kg di carbone attivo Norit PK 1-3 arrivato dall’Italia. Questa operazione ha dato come risultato immediato la rimozione completa dei contaminanti all’uscita del filtro. Vedere sul grafico 3 i valori uguali a zero prima dell’aggiunta di ipoclorito nella fase di disinfezione La formazione di ulteriori bassi livelli di THMs dopo il trattamento è fisiologica ed è dovuta al dosaggio di piccole quantità di ipoclorito per preservare l’acqua nei sacchetti prima del suo consumo (grafico 3). Per ridurre ulteriormente la loro formazione, sarebbe necessario allungare i tempi di residenza dell’acqua nella fase di ossidazione dell’impianto ma, anche in questo caso, con l’uso dell’ipoclorito come disinfettante, si formeranno sempre minime quantità di THMs. Comments and conclusions. The picture reported in the introduction, clearly shows that the water quality has been reduced in the last months. For this reason, it was necessary to replace the carbon filter with a new one. Total THMs, after water treatment was superior to the maximum limit allowed by the Italian legislation when the water flush was between 2500 and 3500 liters/hour and it was comparable with the level detected before the filter (see picture 2) The replacement has been carried out in the middle of September by the technicians present on the plant with 300 Kg of Norit PK 1-3 activated carbon. After this operation, the contaminants have been completely removed just after the filter before the addition of hypochlorite in the disinfection step (See picture 3). Further formation of low level of THMs is physiological and it is due to the addition of sodium hypochlorite to preserve the water before its use. Lavoro futuro Controllare regolarmente il livello di contaminanti prima e dopo il passaggio dell’acqua nell’impianto e sostituire il carbone quando necessario, in base ai dati analitici ottenuti. Next step Check regularly the level of contaminants in the water before and after the treatment on the Waterline and, driven by the analytical results, replace the carbon filter with a new one when necessary. Lista di distribuzione (Distribution list) 1.2.3.4.5.- Italian Red Cross Hospital in Baghdad Sala operativa per l’Emergenza Iraq (Roma) 3 CIE di Verona Comitato CRI di Codogno CAP Gestione di Milano