florim ceramiche spa

Transcript

florim ceramiche spa
MODENA CENTRO PROVE s.r.l.
Sede legale e Laboratori: 41123 Modena (Italy) - Via Sallustio, 78
Tel. 059 822417 r.a. - Fax 059380281 - e-mail : [email protected] - www.modenacentroprove.com
C.C.I.A.A. Modena n. 228587 - Tribunale di Modena n° 2231 - C.F. e P. IVA n. 01592020364
MECCANICA
ECOLOGIA
CERAMICA
To
Modena, 29/02/16
ALIMENTARE
FLORIM CERAMICHE SPA
VIA CANALETTO 24
41042 FIORANO MODENESE MO
Certificato n°
50 100 4582
Attn.
SIG. TURRINI
Diploma
IWR/IT n°
30438
MATERIAL and/or SAMPLE to be tested : PORCELAIN TILES;
Socio
Denomination of the Sample
:
748370 PIETRE/3 LIMESTONE WHITE 60X60 RET
TONO A50 CAL 5;
Membro
Client Reference:
Your delivery VS CONSEGNA
date:
11/02/2016
Socio
Here attached, you will receive the Test Report of Serial No. 20161139/n, which shows the
results of tests required.
Iscritto
MODENA CENTRO PROVE
Page 1 of 1
MODENA CENTRO PROVE s.r.l.
Sede legale e Laboratori: 41123 Modena (Italy) - Via Sallustio, 78
Tel. 059822417 r.a. - Fax 059380281 - e-mail : [email protected] - www.modenacentroprove.com
C.C.I.A.A. Modena n. 228587 - Tribunale di Modena n° 2231 - C.F. e P. IVA n. 01592020364
TEST REPORT: 20161139/1
20161139
Modena, 29/02/16
CUSTOMER
FLORIM CERAMICHE SPA - - VIA CANALETTO 24 - 41042 - FIORANO
MODENESE - MO
MATERIAL and/o SAMPLE to be
tested
PORCELAIN TILES;
Denomination
748370 PIETRE/3 LIMESTONE WHITE 60X60 RET TONO A50 CAL 5;
Date of sample reception
11/02/2016;
Kind of test executed
Determination of Slipperiness
Referring standards
DIN 51097:1992
Shifting from standards
None
Equipment
Pullmeter with ramp cod. MCP C23
Calibration
RT n. 08 of 28/04/2014
Subcontracted phases
None
Sampling made by
Customer
The test results showing in this Report are only referred to the sample taken by our staff or supplied by the Customer. He commits
himself to reproduce integrally this document. Partial reproduction is forbidden.
The times of retain of the samples was indicated in the offer related to the test report.
Page 1 di 2 of Test Report n° 20161139/1
MODENA CENTRO PROVE s.r.l.
Sede legale e Laboratori: 41123 Modena (Italy) - Via Sallustio, 78
Tel. 059822417 r.a. - Fax 059380281 - e-mail : [email protected] - www.modenacentroprove.com
C.C.I.A.A. Modena n. 228587 - Tribunale di Modena n° 2231 - C.F. e P. IVA n. 01592020364
DETERMINATION OF SLIPPERINESS
Beginning date : 02/12/2016
SAMPLE :
Analysis ending date : 02/15/2016
Ceramic tiles marked « 748370 PIETRE/3 LIMESTONE WHITE 60X60 RET TONO A50 CAL 5»
A person walks backwards and forwards barefoot across the tiles to be tested, the inclination of which is
increased by about 1° per second; the angle of inclination at which the person is no longer in conditions of safety is
defined as the slip angle. The surface is wet continuously with a solution ( 1 g/l of wetting agent + water ).
RESULTS
•
•
•
•
Sample dimensions (length, width)
Width of joints
Grountig substance
D of profiles
• SLIP ANGLE
• CLASSIFICATION
:
:
:
:
1x 0.5 (m)
5 (mm)
mortar
none
:
:
22,0°
B (A+B)
CLASSIFICATION
Total Average Values
Group Classification
< 12
0
A
B
C
≥ 12°
≥ 18°
≥ 24°
Page 2 di 2 of Test Report n° 20161139/1
MODENA CENTRO PROVE s.r.l.
Sede legale e Laboratori: 41123 Modena (Italy) - Via Sallustio, 78
Tel. 059822417 r.a. - Fax 059380281 - e-mail : [email protected] - www.modenacentroprove.com
C.C.I.A.A. Modena n. 228587 - Tribunale di Modena n° 2231 - C.F. e P. IVA n. 01592020364
TEST REPORT: 20161139/2
20161139
Modena, 29/02/16
CUSTOMER
FLORIM CERAMICHE SPA - - VIA CANALETTO 24 - 41042 - FIORANO
MODENESE - MO
MATERIAL and/o SAMPLE to be
tested
PORCELAIN TILES;
Denomination
748370 PIETRE/3 LIMESTONE WHITE 60X60 RET TONO A50 CAL 5;
Date of sample reception
11/02/2016;
Kind of test executed
Determination of the Anti-Slip characteristics
Referring standards
DIN 51130:2014
Shifting from standards
No one
Equipment
Pullmeter with ramp cod. MCP C23
Calibration
RT n. 08 of 28/04/2014
Subcontracted phases
No one
Sampling made by
Customer
The test results showing in this Report are only referred to the sample taken by our staff or supplied by the Customer. He commits
himself to reproduce integrally this document. Partial reproduction is forbidden.
The times of retain of the samples was indicated in the offer related to the test report.
Page 1 di 2 of Test Report n° 20161139/2
MODENA CENTRO PROVE s.r.l.
Sede legale e Laboratori: 41123 Modena (Italy) - Via Sallustio, 78
Tel. 059822417 r.a. - Fax 059380281 - e-mail : [email protected] - www.modenacentroprove.com
C.C.I.A.A. Modena n. 228587 - Tribunale di Modena n° 2231 - C.F. e P. IVA n. 01592020364
DETERMINATION OF THE ANTI-SLIP CHARACTERISTICS
Beginning date : 02/12/2016
SAMPLE :
Analysis ending date : 02/15/2016
Ceramic tiles marked «748370 PIETRE/3 LIMESTONE WHITE 60X60 RET TONO A50 CAL 5 »
The test regards the working areas with a high slipping risk: the procedure foresees that a person taking
part in the test walks on an inclined plane which is floored with the tested tiles and greased an oil whose viscosity is SAE
10W-30. During the execution of the test it is determined if the tested material may be properly laid down in specific work
environments.
There is an average inclination which determines the insecurity of the person walking on the inclined
plane and causes the classification of the tested tiles in one of five groups used to determine the sliding resistance.
RESULTS
• Mean inclination angle αges : 13,9°
• Classification
: R 10
CLASSIFICATION
Note :
Mean value αges
Class
6° ≤ αges ≤ 10°
10° < αges ≤ 19°
19° < αges ≤ 27°
27° < αges ≤ 35°
αges > 35°
R9
R 10
R 11
R 12
R 13
The group classification give the parameter for determine the sliding resistance: the group R 9 is less anti-slip,
the group R 13 as the maximum effectiveness anti-slip.