MMP Gas Recup Bale out - Molten Metal Products

Transcript

MMP Gas Recup Bale out - Molten Metal Products
MMP
MMP
molten metal products
molten metal products
MORGAN MKV
MORGAN MKV
recuperative bale OUT FURNACE
recuperative bale OUT FURNACE
HIGH EFFICIENCY
The MK V Gas Fired Recuperative Furnace provides the maximum
economy in energy costs so far and is constructed using the most
efficient low thermal mass materials in the lining.
The combination of
recuperation, effective
conversion to radiant
heat transfer and
the use of advanced
insulating materials
provide a melting and
holding furnace of
exceptional efficiency
with comfortable
working conditions.
By recycling part of the waste energy from the exhaust gasses, typically
35% can be saved. Savings as high as 50% have been seen when
replacing some conventional brick lined furnaces.
Radiation losses are minimised by the use of a well insulated swing aside
cover that can cover the crucible when no baling is needed.
The superb insulation allows for excellent melting performance from
the compact high efficiency burner. The burner also facilitates improved
internal heat circulation and transfer through convection, producing a
more even heat distribution around the crucible enhancing crucible life.
SIZE RANGE
The advanced insulation materials used in the furnace lining result in low
casing temperatures, providing comfortable working conditions.
Other crucible patterns than those shown in the table are available to
provide the capacity span indicated for each size reference.
Working conditions are also optimised by very low noise emissions, as the
exhaust recuperator also acts as an effective silencer.
RADIANT PANEL ASSEMBLIES
Twelve high alumina radiant panels surround the crucible and generally
extend to the full depth of the furnace chamber. The self supporting
and interlocking design provides easy removal, should a panel require
changing.
These panels efficiently convert gas energy into radiant energy.
The MK V Recuperative Gas Fired Bale Out is available in the size range
85kg - 1327kg aluminium.
Fuel types
The furnace is available for the following gaseous fuels:
Natural Gas:
Propane: Butane: Dynamic Pressure: Note: 9000 kcals/m³
22000 kcals/m³
28000 kcals/m³
20 - 35mbar
Pressures higher than 35mbar will require additional regulation
Electrical Supply: 400/415v/480v 3 Phase 50/60hz
Size 1/2 230v 1 Phase 50/60 hz Available
Recup 01/12. MMP reserve the right to change specs. at any time and are not responsible for typographical errors
FURNACE DESCRIPTION
MMP Ltd
Unit 7 Crucible Business Park
Woodbury Lane
Norton
Worcester WR5 2BA
t: +44 (0) 1905 728200
f: +44 (0) 1905 767877
e: [email protected]
• Significant Energy Savings (up to 50%) • Improved Crucible Life
• Very Low Noise Levels • Environmentally Low Emissions
www.moltenmetalproducts.com
MMP
molten metal products
METAL TEMPERATURE CONTROL
TEMPERATURE DEPRESSION
The temperature can be sensed from
a floating, fixed or crucible pyrometer.
The dual display programmable digital
controller maintains close control, by
regulating the heat input to the burner,
relative to actual metal temperature and
set value.
This energy saving and safety feature, enables a lower
holding temperature to be automatically selected
during periods of non-use.
The control panel’s real time clock can be
programmed to select reduced temperature and to
return to operational value when required.
The time clock can also be set to switch the furnace
on and off at pre-set dates and times
KEY FEATURES
Data based on optimum foundry conditions and practices. For typical foundry operations a
performance factor of 90% of performance ratings should be assumed.
ADVANCED DESIGN
The MK V Recuperative Furnace is compact, of robust design and suitable
for temperatures up to 850ºc. With the exception of the control panel, it
has no separate stand alone components. High reliability is obtained by the
avoidance of moving parts such as motorised dampers and use of high
reliability components.
Data for zinc alloys available on request
GAS FIRED MkV recuperative BALE OUT. AIR TEMP. 20C . Furnace Size Reference Capacity Range Kg Al Working Capacity Power Gas Power Consumption Holding kWh/hr
Melt Time (Mins)
GAS BURNER
The furnace is equipped with a high performance, medium velocity, low
Nox., fully proportioning, nozzle mix gas burner. Air is delivered to the burner
via a recuperator from a compact speed controlled blower, regulated by a
solid state inverter, avoiding valves and linkages. Air and gas are mixed in
proportion relative to cold air flows, maintaining ratio across the turn down
range. The robust burner is designed to minimise Nox. emissions up to the
highest preheat values and conforms to European safety standard EN746 and
other world standards.
Radiant Panel
Kg kWh Covered Uncovered 1st Heat Subsequent
Heats
Gas Requirement @20 - 35m Bar m³/Hour
ALUMINIUM TO 720c
Size 1 85 - 172 119 165 100 100 9.5 9.5 21 21 105 135 70 90 Size 2 163 - 327 233 271 115 140 11 15 28 30 146 150 115 110 Size 3 310 - 575 444 575 166 166 24 25 45 46 200 258 152 198 Size 4 595 - 1135 815 1024
280 280
30 32
58 59
230 280
166 208
Size 5
762 - 1310
762 1310 390
390
35
40
80
86
230
230
170
180
Size 6
945 - 1326
945 1326
390
390
45
55
95
105
180
240
130
180
11 12 18 29 44
44
11 15 18 29
44
44
Typical specific energy consumption. Subsequent heat: 0.9kWh/kg. Throughput melting: 0.8kWh/kg *variances are subject to crucible pattern.
Control Panel (with optional mimin display)
RECUPERATOR.
The fitted hot air recuperator is of simple robust design, delivering up to
250ºc air preheat to the burner. Having dimensions similar to normal exhaust
extensions, it also reduces the already low noise values to less than 75dBa
CONTROL PANEL
A modern high quality control panel provides the following features:
• Protective circuit breaker, door interlocked
• Fully approved, flame failure controller
• Programmable timeclock
• Fully proportional digital temperature controller
• Policeman lining protection pyrometry
• Crucible and burner operational hour meters
• Gas burner operation display
• Temperature depression selection switch
SIZE 1 SIZE 2 SIZE 3 SIZE 4 SIZE 5 SIZE 6
Capacity by Crucible Capacity RangeCapacity RangeCapacity RangeCapacity RangeCapacity RangeCapacity Range
Kg Al.Kg Al.Kg Al.Kg Al.Kg Al.Kg Al.
85 - 172 163 - 327 310 - 575 595 - 1135 762 - 1327 945 - 1326
Pattern Kg Pattern Kg Pattern Kg Pattern Kg Pattern Kg PatternKg
BX166/BU100 BX167/BU125 BX168/BU150 BX169/BU175 BX171/BU200 BX177/BU202 1190
Furnace A
Dimensions B
900
(mm)C
1610
2135
D
433
E
Shipping (approx)
Net Weight Kg
Gross Weight Kg
Volume m3
85
103
119
144
165
172
BX202/BU210 163
BX302/BU250 233
BX401/BU300 271
BX402/BU350 327*
BX1264 310
BX847/BN500 441
BX247/BU500 444
BX263/BU600 557*
BX850/BN600 595 52100 BX851/BN800 810 52330 BX852/BN1100 930 52770
BX853 1135
762 60815
1098 60990
1310 61050
exhaust
945
1196
1326
burner
d
a 900
1190
900 - 980*
1610
2125 - 2205*
510
900
1100
3.7
1100
3.7
1420
1130 - 1270 1840
2335 - 2500 *
660
1300
1500
5.35
1526
1330 - 1520*
2020
2560 - 2750*
735
2500
2750
10
1625
1400 - 1520
2100
2630 - 2750
850
3000
3350
11
1694
1400 - 1630
2200
2630 - 2850
900
3500
e
b
note: opposite hand available
c
3900
12
* Increased furnace height
t: +44 (0) 1905 728200 • f: +44 (0) 1905 767877 • e: [email protected]
www.moltenmetalproducts.com