EDB1000 - Elettrolab

Transcript

EDB1000 - Elettrolab
Elettrolab S.r.l.
Via dell' Industria, 25 - 31020 S. Vendemiano (TV)
Tel. 0438 470047 Fax. 0438 470100 - www.elettrolab.it – e-mail [email protected]
EDB1000
Electronic Digital Ballast 1000W DSP controlled
Electronic digital ballast suitable for 1000W HID lamps
Features:













Built-in PFC (pf>0.98 100-260 Vac full range).
EMI filter inside.
Compact shape, low weight.
DSP controlled.
The ballast can be controlled and programmed stand alone, with DMX or with
external interface board or Delectra Remoto.
Flicker free output.
On/off and dimmer/strobo switches.
Continuous dimmer control by PWM.
Auxiliary fan output for forced cooling included.
Short and open circuit protected.
Fans outputs for forced cooling included with DSP controlled on-off.
External ignitor is required.
CE standards compliant.
Electronic Digital Ballast 1000W Rev. 1.07
Page 1 di 8
Elettrolab S.r.l.
Via dell' Industria, 25 - 31020 S. Vendemiano (TV)
Tel. 0438 470047 Fax. 0438 470100 - www.elettrolab.it – e-mail [email protected]
Electrical features:
Min
Tipical
Max
Main voltage
100
-
260
Power factor
-
0.99
-
4.4
(@Vin=260V)
5
12
(@Vin=100V)
Arms
Max Lamp power
-3.5%
1000
+3.5%
W
Minimum power
-3.5%
381
+3.5%
W
Max start-up lamp current
13
14
15
A
Square wave frequency
2%
172
2%
Hz
Open circuit voltage (with ignitor)
330
-
370
V
Voltage (@ 2.5W fan load)
22
24
27
V
Voltage (@ no load)
30
33
38
V
-
-
7
W
Voltage (*)
-3%
375
+3%
V
Operating and storage temperature
-20
-
45(**)
°C
T8 A at 230 Vac
-
T20 A at 100 Vac
MAIN input:
Input line current @ Pout=1000W
Vrms
LAMP output:
FAN output:
Max power
AUX output:
Fuse request (external)
* optional AUX output for supply a max 30W dc/dc converter.
** with forced cooling (see Page 4 for the details).
Dimensions:
Height / Length / Width
2638 / 7677 / 4449
Electronic Digital Ballast 1000W Rev. 1.07
mils
Page 2 di 8
Elettrolab S.r.l.
Via dell' Industria, 25 - 31020 S. Vendemiano (TV)
Tel. 0438 470047 Fax. 0438 470100 - www.elettrolab.it – e-mail [email protected]
Height / Length / Width
67 / 195 / 113
Electronic Digital Ballast Communication:
mm
To connect to the electronic ballast you need an optional control board. Please contact
ELETTROLAB S.r.l. for further informations: [email protected]
With control board you can change:





Type of lamp: 1000W. (See table below.)
Maximun power.
Minimum power (for dimmer or strobo).
Supply lamp frequency.
DMX address.
Or you can monitor:





Internal Heatsink temperature.
Lamp power, voltage and current.
Lamp life.
Ballast life.
Time missing before of ignition lamp (in case of lamp hot).
With 4 channel DMX control you can:




CH1 = DIMMER FUNCTION: 0 = Full Power, 1 ÷ 255 → ½ Power ÷ Full Power.
CH2 = ZAP FUNCTION : 0 ÷ 255 → 6.5 ÷ 40 Hz (active 90 sec. after lamp strike).
CH3 = CONTINUOS LAMP FADING : triangular shape 13 ÷ 100 mS.
CH4 = ON-OFF FUNCTION : 0 ÷ 128 → Lamp off, 129 ÷ 255 → Lamp on.
On request:


485 BUS for internal fixture communications.
Other customizzed functions/setting for lamp.
LAMP specification:
Min
Typical
Max
Lamp voltage
-
-
150
Vrms
Lamp current
-
-
12.5
Arms
When the lamp current reaches the maximun permissible value the ballast behaves as a
constant current source.
For very low output voltages a fault condition is detected (short circuit).
Electronic Digital Ballast 1000W Rev. 1.07
Page 3 di 8
Elettrolab S.r.l.
Via dell' Industria, 25 - 31020 S. Vendemiano (TV)
Tel. 0438 470047 Fax. 0438 470100 - www.elettrolab.it – e-mail [email protected]
When the lamp voltages exceeds the maximun permissible value a fautl condition is
detected (over voltage).
Cooling:
For optimun cooling performance the fan should be 24 Vdc 60x60 mm with min airflow
23.5 CFM (0.67 CMM).
Its position should be like the photo below. The correct airflow is indicate on the label.
Thanks to the ballast shape you can put the fan very close to the same.
Wiring of the remote control:
PWM dimmer from 10 Khz to 20 Khz
Electronic Digital Ballast 1000W Rev. 1.07
Page 4 di 8
Elettrolab S.r.l.
Via dell' Industria, 25 - 31020 S. Vendemiano (TV)
Tel. 0438 470047 Fax. 0438 470100 - www.elettrolab.it – e-mail [email protected]
Wiring of the ballast:
Rear view:
Front view:
Electronic Digital Ballast 1000W Rev. 1.07
Page 5 di 8
Elettrolab S.r.l.
Via dell' Industria, 25 - 31020 S. Vendemiano (TV)
Tel. 0438 470047 Fax. 0438 470100 - www.elettrolab.it – e-mail [email protected]
Fixing point:
Electronic Digital Ballast 1000W Rev. 1.07
Page 6 di 8
Elettrolab S.r.l.
Via dell' Industria, 25 - 31020 S. Vendemiano (TV)
Tel. 0438 470047 Fax. 0438 470100 - www.elettrolab.it – e-mail [email protected]
Ignitor:
Electronic Digital Ballast 1000W Rev. 1.07
Page 7 di 8
Elettrolab S.r.l.
Via dell' Industria, 25 - 31020 S. Vendemiano (TV)
Tel. 0438 470047 Fax. 0438 470100 - www.elettrolab.it – e-mail [email protected]
The recommended ignitor is: DI18, DI19.
Ignitor: DI18.
Ignitor: DI19.
Warning:
The ignitor produces starting voltage in the order of several kV and electromagnetic
radiation interference which are hazardous to personnel and sensitive instrumentation.
The electronic ballast must never be installed or operated in an explosive or volatile
atmosphere. Never use the ballast or ignitor near flammable gases or liquids.
Do not touch any conductive parts during operation.
All installation and repair work on this unit is only permitted by qualified personnel.
No potential isolation is provided between line input and output. Accidentally grounding of
an output terminal by direct contact or arcing to GND can damage the unit (no warranty
replacement).
Note:
For further information on tecnology, delivery terms conditions and price please contact
ELETTROLAB S.r.l. [email protected]
Electronic Digital Ballast 1000W Rev. 1.07