dulux trade paints

Transcript

dulux trade paints
N T E G R A T I O N
RCHITECTURE
Openable window:
Aluminium thermally seperated framed
double glazed unit with opening lights.
Double glazed argon filled with
low E glass.
Window:
Aluminium thermally seperated framed
double glazed unit with opening lights.
Double glazed argon filled with low E glass.
Colour/finish to clients requirements.
Mechanical ventilation to shower room
to be capable of extracting air at a
rate of not less than 15 litres per
second providing 3 air changes per
hour operated intermittently.
Linked to light switch to provide
20 minute over run with 100m dia
ducting as shown.
WASH BASIN: TO SHOWER ROOM.
- Wash basin: Ideal Standard Studio
Semi-countertop Basin,
- Size: 560x460mm, 1 tap hole.
- Supplier: Ideal Standard.
- Material: Vitreous China.
- Colour: White.
- Fixings: As standard.
- Taps: For high water pressure, requires
min 1 Bar : Use Single Lever Mono Basin
Mixer.
For low water pressure, 0.2 Bar: Use
Economy Single Lever Basin Mixer.
- Supplier: Home of Ultra Eon.
- Material: Chrome.
WC PAN AND CISTERN: TO SHOWER ROOM.
- Pan: Envy Wall Hung WC HO Ref. NV1738
- Material: Vitreous China.
- Seat and cover: Envy Seat and Cover Top
Fix hinge Ref. NV7855
- Supplier: Twyford.
- Cistern: Cistern Assembly BSIO Duct 6L.
14X9 Flushbend. Ref. CX9160XX.
- Fittings: SR8138XX galerie w/hung wc/bidet
bracket & bolts assembly
WF1240WH pan connector 'p trap.
CF3018CP lever assy-extended 240 wall.
- Sealing: Silicone sealant at junction of
cistern with cistern enclosure.
- Colour: White.
100mm Iso Spray Foam strictly
to manufacturers recommendations
12mm marine plywood sheets
screw fixed to studwork
Service zone
Preservative treated sw studs/blocking
as required
12mm thick 1200x900mm cement based
tile backer boards to all walls of shower
room with Altro 2.5mm
non-slip vinyl floor finish and Altro vinyl wall
finish having coved skirting junctions
between floor and wall finishes.
300mm wide x 1000mm high
moisture resistant mirror with
flat polished edges and 380mm
long vanity light above with
shaver socket
22mm thick T&G flooring quality
chipboard sheets.
All edges to be supported.
Sheets to be screw-fixed at
300mm c/c to treated battens
below
Skirting trim
Treated softwood 50mm
wide, depth to requirements
@ 400mm c/c on insulation
seperating layer
DETAILED SECTION A-A
SHOWER
Container subfloor
Telivision and tv socket and switch, etc.
100mm Iso Spray Foam strictly
to manufacturers recommendations
1981X610mm solid core door leaf
100mm Iso Spray Foam strictly
to manufacturers recommendations
A
A
37.5mm Kingspan K18 to inner face of
the metal studs with a minimum 3mm
plaster skim.
100mm deep metal studs at
400mm c/c
Altro Aquarius floor finish, thickness 2mm,
to bedroom and shower room with coved
upstand skirtings.
Colour to clients requirements
565mm
EMULSION PAINT TO WALLS AND CEILINGS
TO BEDROOM
- Manufacturer: ICI Dulux Trade Paints.
- Paint type:
Dulux Trade Diamond Matt
- Surface(s):
New plaster skimmed ceilings
and walls generally.
- Preparation: To be applied to smooth
properly prepared surfaces
- Initial coat(s): Strictly to
manufacturers recommendations.
- Finishing coats: Strictly to
manufacturers recommendations.
- Colour.: To clients requirements
Twin switched 13A socket outlet
Work desk
LED Eco-Lite
LED Surface mounted ceiling light
17 watt LED light bulb.
Product Ref: LE099.
Colour: White cover with silver sides
Work voltage: AC85-265 Volt.
PF:>85%, CRI:>75
50-60Hz
Diameter: 314mm, depth: 80mm.
1
A-002
SD
Clothes hanging area and shelf above.
2
A-002
Openable window:
Aluminium framed (colour to clients
requirements) to be double glazed
window Min mid pane 'U' value of
1.5W/m2K or better. Glazing to be
clear toughened safety glass in
hermetically sealed double-glazed
units with low 'E' coating and argon
filled cavity. Windows to have min
1/20th floor area as opening lights.
500mm wide skirting to ceiling
impact resistant mirror with
flat polished edges
DETAILED FLOOR PLAN
100mm Iso Spray
Foam strictly
to manufacturers
recommendations
900x900mm shower tray
CYR5046/28LE Cyro Low energy
moisture resistant bathroom light
fitting (OF3848LE)
Smoke detector to be self
contained and mains operated with
battery back-up and conforms to
BS 5839-6:2004.
37.5mm Kingspan K18 to inner face of
the metal studs with a minimum 3mm
plaster skim.
Altro Aquarius floor finish, thickness 2mm,
to bedroom and shower room with coved
upstand skirtings.
Colour to clients requirements
Mira Sport Electric Shower 9.0kW - White/Chrome
12mm thick 1200x900mm cement based
tile backer boards to all walls of shower
room with Altro 2.5mm
non-slip vinyl floor finish and Altro vinyl wall
finish having coved skirting junctions
between floor and wall finishes.
Window:
Aluminium framed (colour to clients
requirements) to be double glazed
window Min mid pane 'U' value of
1.5W/m2K or better. Glazing to be
clear toughened safety glass in
hermetically sealed double-glazed
units with low 'E' coating and argon
filled cavity. Windows to have min
1/20th floor area as opening lights.
Architecture
12 Crummock Gardens, The Hyde, London NW9 0DG.
Tel: 020 8200 7758
Email: [email protected]
DETAILED ELEVATION 1
DETAILED ELEVATION 2
EMULSION PAINT TO SHOWER ROOM CEILING.
- Manufacturer: ICI Dulux Trade Paints.
- Paint type:
Dulux Trade Bathroom Paints.
- Surface(s):
New plaster skimmed ceilings
and walls generally.
- Preparation: To be applied to smooth
properly prepared surfaces
- Initial coat(s): Strictly to
manufacturers recommendations.
- Finishing coats: Strictly to
manufacturers recommendations.
- Colour: To clients requirements
Integration
838mm wide glazed exterior quality metal door.
Double glazed argon filled with low E glass
and thermally seperated metal door frame.
U Value Exterior Entrance Door: 2.0Wm2
GLAZING IN CRITICAL LOCATIONS:
All glazing in critical areas such as:
1.
Glazing up to 800mm above floor level in internal and
external walls and partitions and all glazing panels where part
of the panel is within this dimension.
2.
Glazing up to 1500mm above floor level in a door or
side panel within 300mm of the door and all glazing panels
where part of the panel is within this dimension should be
fitted with safety glass to BS 6206:1981
EXTERNAL WINDOWS: Aluminium framed (colour to clients
requirements) to be double glazed window Min mid
pane 'U' value of 1.5W/m2K or better. Glazing to
be clear toughened safety glass in
hermetically sealed double-glazed units with low 'E'
coating and argon filled cavity. Windows to have min
1/20th floor area as opening lights.
ELECTRICAL:
The competent persons scheme must be used.
All wiring and electrical work must be designed, installed,
inspected and tested in accordance with the requirements of
BS7671, the IEE 17th edition Wiring Guidance and Building
Regulation Part P (electrical safety) by a person who is a
member of the Competent Person Scheme authorised by the
Secretary of State.
AND
The person who is a member of the Competent Persons Scheme
is to send to the local authority a self-certification certificate
within 30 days of the electrical works completion.
The client must receive both a copy of the self-certification
certificate and a BS7671 Electrical Installation Test Certificate.
Client
2012 OLYMPIC LIVING.
637a Romford Road
Newham,
London,
E12 5AD
Project
2012 OLYMPIC LIVING.
FOREST ROAD,
BARKING,
ESSEX.
Drawing Title
DETAILED VIP ROOM PLAN
ELEVATIONS AND SECTION A-A
Scale
Job no.
12001
Date
240 Volt 3-phase supply
1:25
at A2 Size
Jan 2012
SMOKE DETECTORS: smoke detectors as shown on floor plans
to be self contained and mains operated with battery back-up
and conforms to BS 5839-6:2004.
Drawing no.
Status & Rev
–
P
/ A
Internal Lighting to be low energy.
MECHANICAL VENTILATION: Mechanical ventilation to shower
room, to be capable of operated intermittently, linked to light
switch to provide 20 minute over run. To have 100m dia ducting.
To part F of the Building Regulations.
POSITIONING OF POWER POINTS ETC.
Twin 13Amp switched socket outlet to desk.
Provide 13Amp switched electrical socket for television and
supply tv aerial socket.
Wall mounted socket outlets, light switches, tv sockets, etc
to be located between 450mm and 1000mm above floor level.
MISC NOTES:
* Structural timber to be C16 grade unless otherwise stated.
* NOTE: All timber studs, blocking, etc to be preservative treated
* An Electrical Certificate must be provided upon completion
of the works.
General Notes
Jan 2012
This drawing is the copyright of Integration
Architecture.
All dimensions to be checked on site.
Do not scale.
All levels to be checked on site and refer to
Ordnance Survey Datum Newlyn unless
alternative datum given.
All errors and omissions to be reported to
the Architect prior to commencement.
This drawing must be read in conjunction
with the relevant specification clauses.
This drawing must not be used on site unless
issued for construction.
Status:
R = Record. P = Preliminary. Pl = Planning.
B = Building Control. T= Tender.
C = Construction.