44° Congresso Nazionale della Società Italiana di
Transcript
44° Congresso Nazionale della Società Italiana di
44° Congresso Nazionale SIBioC - Riassunti Poster 44° Congresso Nazionale della Società Italiana di Biochimica Clinica e Biologia Molecolare Clinica (SIBioC) Roma, 5-7 novembre 2012 Riassunti Poster Codice Poster Argomento • P001-P037 Biologia molecolare clinica • P043-P091 Tecnologia, strumentazione e valutazione metodi • • • • • • • • P038-P042 P092-P109 P110-P127 P128-P133 P134-P143 P144-P150 P151, P155, P161-P163 P166, P169 Controllo di qualità, standardizzazione, tracciabilità Patologia cardiovascolare Varie Allergia Patologie renali Patologie genetiche Endocrinologia P152-P154, P156-P160 Patologia oncologica • P170-P184 Ematologia • P191-P205 Farmacologia e tossicologia • • • • • • • • • • • • P164-P165, P167-P168 P185-P190 P206-P211 P212-P219 P220-P230 P231-P242 P243-P250 P251 P252 P253, P263 P254, P256, P260, P262 P264, P267 Coagulazione Malattie infettive Patologie autoimmuni Gravidanza, neonatologia e pediatria Diabete e sindrome metabolica Analisi decentrate Sport e nutrizione Patologie osteoarticolari Patologie epatiche Gestione del laboratorio, automazione e applicazioni informatiche P255, P257, P258, P261 Patologie neurologiche P259 Farmacogenetica P265, P266 Nota dell’Editore: i riassunti sono stati riprodotti senza alcuna revisione dal materiale direttamente fornito dagli autori. biochimica clinica, 2012, vol. 36, n. 6 471 44° Congresso Nazionale SIBioC - Riassunti Poster P001 A SPECIFIC IMMUNOPHENOTYPE AND AN INCREASED ADIPOGENIC POTENTIAL CHARACTERIZED HUMAN AMNIOTIC MESENCHYMAL STEM CELLS (HA-MSCS) ISOLATED FROM OBESE PREGNANT WOMEN AT DELIVERY 1 1 2 C. Nardelli , L. Iaffaldano , M. Raia , M. Ferrigno, E. 2 3 4 1 Mariotti , F. Quaglia , G. Labruna , V. Capobianco , A. 3 1 1 Capone, G.M. Maruotti , L. Pastore , R. Di Noto , P. 3 1 Martinelli , L. Sacchetti, L. Del Vecchio 1 CEINGE-Biotecnologie Avanzate S.C.a R.L., Naples, Italy and Dipartimento di Biochimica e Biotecnologie Mediche, Università degli Studi di Napoli Federico II, Italy 2 CEINGE-Biotecnologie Avanzate S.C.a R.L., Naples, Italy 3 Dipartimento di Scienze Ostetrico-Ginecologiche Urologiche e Medicina della Riproduzione, Università degli Studi di Napoli Federico II, Italy 4 Fondazione IRCCS SDN–Istituto di Ricerca Diagnostica e Nucleare, Naples, Italy Maternal obesity is associated to an increased fetal risk of obesity and other metabolic diseases. Human amniotic mesenchymal stem cells (hA-MSC) have not yet been characterized in obese women. The aim of this study was to isolate and compare the immunophenotypes of hAMSCs from obese (Ob-) and normal weight control (Co-) women to identify alterations that could predispose the fetus to obesity. We enrolled 16 Ob- and 7 Co-women at delivery (mean/SEM before pregnancy BMI: 40.3/1.8 2 2 kg/m and 22.4/1 kg/m , respectively). Human A-MSCs were phenotyped by flow cytometry, several maternal and newborn clinical and biochemical parameters were also measured. Induction of adipogenesis revealed a higher adipogenic potential of Ob-hA-MSCs compared with CohA-MSCs as witnessed by significantly higher PPARγ and aP2 mRNA levels (P=0.02 and P=0.03, respectively) at post-induction day 14. We found 1/38 tested membrane antigens was higher expressed on the Ob-hA-MSC than on the Co-hA-MSC. Further, we observed that IFNγ upregulated specific membrane antigen expression in cultured Co-hA-MSCs so overlapping the Ob-hA-MSCs immunophenotype and increased the adipogenic potential of these cells. We also found leptin/adiponectin ratio higher in sera of Ob- than in Co-pregnant women at delivery. In conclusion, our observation suggests that in utero inflammatory conditions in obese pregnancy could drive increased expression of membrane antigens on the surface of hA-MSCs thereby enhancing their adipogenic potential of these cells. Further, we confirm the concept that serum leptin and adiponectin are obesity risk markers that could be used also during pregnancy to evaluate the fetus risk obesity. Grant: MIUR-PRIN 2008. 472 biochimica clinica, 2012, vol. 36, n. 6 P002 ABERRANT F8 GENE INTRON 1 INVERSION WITH CONCOMITANT DUPLICATION AND DELETION IN A SEVERE HEMOPHILIA A PATIENT FROM SOUTHERN ITALY 1 1 1 2 V. Sanna , C. Ceglia , M. Tarsitano , B. Lombardo , A. 3 2 2 3 Coppola , L. Pastore , G. Castaldo , G. Di Minno 1 CEINGE Biotecnologie Avanzate, Naples, Italy Dip. di Biochimica e Biotecnologie Mediche, Università degli Studi di Napoli "Federico II", Naples, Italy 3 Centro di Coordinamento Regionale Emocoagulopatie, Dip. di Medicina Clinica e Sperimentale, Università degli Studi di Napoli "Federico II", Naples, Italy 2 Background: In severe haemophilia A, the most frequent mutations are the intron 1 and intron 22 inversions, responsible for about half of the affected patients. These genetic alterations result from the intrachromosomal recombination between intronic regions (int1h and int22h) and their homologous extragenic copies in telomeric position (1). Aberrant patterns for F8 gene intron 1 inversion (inv1) have been described in a few cases so far. Here, we characterized the molecular defect in a severe haemophiliac and his relatives. Results: The patient exhibited two bands of int1h-1 region (1908- and 1323-bp), corresponding to the wild type and inverted configurations, with no bands of int1h-2 fragment. The amplification of all F8 gene coding sequences, promoter, 5’ and 3' regions was present with no other causative mutations. The multiplex ligation-dependent probe amplification (MLPA) analysis highlighted a large duplication comprising exons 2-6 of the F8 gene, confirmed further by comparative genomic hybridization (CGH) and quantitative-PCR (qPCR) with a concomitant extragenic deletion towards the telomer. His mother and sister showed a pattern compatible with the carrier status. Conclusions: These results show a complex sequence rearrangement related to the inv1 previously not described, due to a large duplication affecting the F8 gene with an additional extragenic deletion in telomeric position, confirming the high mutational heterogeneity of haemophilia A. (1) Castaldo G, D’Argenio V, Nardiello P, et al. Haemophilia A: molecular insights. Clin Chem Lab Med 2007;45:450-61. 44° Congresso Nazionale SIBioC - Riassunti Poster P003 ALTERATIONS OF THE LDL RECEPTOR GENE IN FAMILIAL COMBINED HYPERLIPIDEMIA 1 1 P004 ANALISI DELLA PREDISPOSIZIONE GENETICA ALLA CELIACHIA IN PAZIENTI CON INFERTILITA’ IDIOPATICA E IN PAZIENTI FERTILI. 2 A. D'Angelo , M.N. D'Agostino , M.D. Di Taranto , A. 1 3 3 3 Ruotolo , G. Marotta , M. Gentile , P. Rubba , G. 1 Fortunato 1 CEINGE S.C.a r.l. Biotecnologie Avanzate, Napoli, Italy; and Dip. di Biochimica e Biotecnologie Mediche, Università degli Studi di Napoli Federico II, Napoli, Italy 2 Fondazione IRCCS SDN, Napoli, Italy 3 Dip. di Medicina Clinica e Sperimentale, Università degli Studi di Napoli Federico II, Napoli, Italy Introduction: The Familial Combined Hyperlipidemia (FCH) is associated with the increase of total cholesterol, triglycerides or both. Its molecular causes have not yet completely clarified although a polygenic and multifactorial basis is considered. Familial Hypercholesterolemia (FH) is a disease characterised by increased plasma concentrations of total and LDL cholesterol, showing a clinical picture overlapping with that of FCH, in some instances. FH is primarily caused by mutations in the LDL-receptor gene (LDLR). We aim to identify LDLR mutations in patients with a clinical diagnosis of FCH. Materials and methods: We enrolled 183 patients from Southern Italy with a clinical diagnosis of FCH. After genomic DNA extraction from peripheral blood samples, the promoter and 18 exons of the LDLR gene were amplified by PCR and directly sequenced. The ROC curves were constructed with ApoB, LDL cholesterol and non-HDL cholesterol values using as discriminate value the presence or absence of LDLR mutations, with MedCalc software. The threshold value was determined by the point farthest from the bisector of the ROC curve. Results: We screened the promoter and 18 exons of the LDLR gene. Direct sequencing analysis revealed mutations in the LDLR gene in 18/183 unrelated FCH patients (mutation rate 9.83%). We observed 14 different mutations. Among the 14 different mutations we found 12 mutations missense and 2 splicing alterations.Through the ROC curve analysis we identified the threshold values of LDL cholesterol equal to 178 mg/dL (83.3% sensitivity and 51.8% specificity), of ApoB equal to 151 mg/dL (61.1% sensitivity and 73.8% specificity ) and of nonHDL cholesterol equal to 265 mg/dL (50% sensitivity and 80.6% specificity) that could be useful to identify FCH patients that have to be screened for LDLR mutations. Conclusions: The screening protocol based on the direct sequencing analysis in the LDLR gene allowed to identify 9.83% of FCH patients with mutation in LDLR gene.The cut-off value of 178 mg/dL for LDL cholesterol is useful to select FCH patients with an high probability of bearing LDLR mutations. S. Egiziano, C. Laporta, V. Mavaracchio, F. Donà, L. Tognetto, L. Bartoloni ULSS12 Veneziana, Dipartimento di Patologia Clinica, Venezia Per valutare il ruolo della predisposizione genetica alla celiachia nell'infertilità idiopatica sono stati analizzati 38 pazienti che si sono rivolti al nostro centro per gli esami propedeutici alla fecondazione assistita e 38 controlli sani, ovvero persone che hanno concepito naturalmente e nei quali è stata esclusa la presenza della malattia celiaca conclamata mediante un questionario telefonico. La tipizzazione HLA degli alleli DQA1, DQB1 e DRB1 è stata eseguita utilizzando kit INNOLiPA (Innogenetics) basati sul principio dell’ibridazione inversa su striscia. La presenza degli eterodimeri DQ2 e DQ8 è associata ad un aumento del rischio di celiachia circa 50 volte superiore rispetto alla popolazione generale. E’ noto che la celiachia, sia conclamata che silente, può indurre problemi riproduttivi sia maschili (ad es. azoospermia ed astenozoospermia) che femminili (difficoltà di concepimento e aborti spontanei) (AV Stazi et al, 2005). In ciascun gruppo metà dei pazienti è di sesso femminile e metà di sesso maschile. La percentuale di pazienti infertili risultati predisposti geneticamente alla malattia celiaca è del 39,5%, di cui il 40% di sesso femminile e il 60% di sesso maschile. Di questi, nell’80% è stata riscontrata la presenza dell’eterodimero DQ2, nel 13,3% la presenza della sola catena beta del dimero DQ2 e nel 6,7% la presenza dell’eterodimero DQ8. Nella popolazione dei controlli sani il 36,8% risulta essere predisposto, con il 43% di femmine e il 57% di maschi. Di questi, nel 57,1% è stata riscontrata la presenza dell’eterodimero DQ2, nel 14,3% la presenza della sola catena beta del dimero DQ2 e nel 28,6% la presenza dell’eterodimero DQ8. Tra i pazienti con infertilità idiopatica sono presenti 11 coppie predisposte e di queste 7 sono composte da un componente predisposto, mentre 4 da entrambi i componenti predisposti. Nei controlli sani invece, sono presenti 13 coppie predisposte e di queste 12 sono composte da un componente predisposto e una soltanto da entrambi i componenti predisposti. Dai risultati ottenuti sembra non esserci correlazione tra infertilità idiopatica e la sola predisposizione genetica alla celiachia, anche se si osserva una significativa differenza tra la presenza dell’eterodimero DQ2 nella popolazione infertile rispetto alla sana. biochimica clinica, 2012, vol. 36, n. 6 473 44° Congresso Nazionale SIBioC - Riassunti Poster P009 CORRELAZIONE TRA CLUSTERINA E PROFILO LIPIDICO IN UNA POPOLAZIONE SARDA 1 1 1 1 A. Baralla , S. Pasella , E. Sotgiu , S. Pinna , A. 1 1 2 1 1 Marchisio , L. Murgia , M. Deiana , P. Mele , L. Deiana 1 Biochimica Clinica e Biologia Molecolare Clinica, Dipartimento Scienze Biomediche, Facoltà di Medicina e Chirurgia, Università degli Studi di Sassari 2 "Ass. Isola dei Centenari", Sassari La clusterina (CLU) è una glicoproteina con una distribuzione pressoché ubiquitaria che risulta implicata in una serie di processi fisiologici e in diverse condizioni patologiche come il diabete, malattie neurodegenerative, malattie cardiovascolari e neoplasie. La clusterina è un eterodimero di 70-80 kDa formata da due catene α e ß legate da ponti disolfuro in cui i carboidrati contribuiscono per il 30% della sua massa molecolare. La clusterina è presente nel plasma sia in forma libera circolante, sia legata a una subclasse delle HDL. Le HDL come noto svolgono un ruolo chiave nel metabolismo del colesterolo plasmatico e nell’insorgenza di numerose patologie dismetaboliche. In questo lavoro abbiamo voluto valutare una possibile relazione tra le concentrazioni nel plasma della clusterina circolante e il profilo lipidico di un gruppo di 65 individui di età compresa tra i 20 e i 100 anni reclutati mediante il progetto AKeA che studia la longevità in Sardegna. Le concentrazioni di clusterina sono state ottenute utilizzando un kit commerciale ELISA Adipogen di tipo competitivo mentre i parametri lipidici sono stati ricavati dalle cartelle cliniche connesse al campione in esame (colesterolo totale, colesterolo HDL, colesterolo LDL e trigliceridi). L’analisi multivariata effettuata sul campione suddiviso per fasce di età (20-50, 80-89, 90-99 e ≥100) ha individuato delle variazioni significative tra i gruppi sia per quanto riguarda i parametri clinici del profilo lipidico sia per quanto riguarda la clusterina, mentre le analisi di associazione hanno individuato una correlazione positiva della clusterina con il colesterolo totale (Pearson r=0.336 p=0.01). Tali risultati indicano come con l’avanzare dell’età ci siano dei cambiamenti significativi nel profilo lipidico di un individuo. Inoltre, la correlazione positiva individuata tra clusterina e colesterolo totale conferma il coinvolgimento di tale proteina nel metabolismo del colesterolo anche se ulteriori studi saranno necessari per chiarirne l’effettivo ruolo. Strickland DK, Ranganathan S. Diverse role of LDL receptor-related protein in the clearance of proteases and in signaling. J Thromb Haemost 2003;1:1663-70. 476 biochimica clinica, 2012, vol. 36, n. 6 P010 DETECTION OF CIRCULATING TUMOR CELLS COULD IMPROVE CLINICAL MANAGEMENT OF PROSTATE CANCER PATIENTS F. Vendittelli, G. Albino , S. Palumbo, C. Paolillo, C. Zuppi, E. Capoluongo Lab. di Biologia Molecolare Clinica, Ist. di Biochimica e Biochimica Clinica, Università Cattolica del Sacro Cuore, Roma Background: The release of tumor cells through the bloodstream (CTCs) is a peculiar sign of the aggressiveness of primary tumor and of inefficiency of therapy. Some reports show that levels of CTCs correlated with prognosis in patients with advanced breast, prostate and colorectal cancers suggesting its use in the clinical management of patients. Up to date, extensive efforts have been directed toward the development of methods for detecting circulating prostate tumor cells as early indicator of disease progression. The current investigation describes preliminary molecular data regarding occurrence of CTCs and their use in clinical management and pharmacological treatment of prostate cancer (PCa) patients. Methods: An immunomagnetic method of CTC enrichment (AdnaTest Prostate Cancer Select) was used on 5 ml starting blood sample and followed by a multiplex PCR (AdnaTest Prostate Cancer Detect) for detection of prostate- and/or cancer-specific markers such as PSA, PSMA and EGFR. Sixteen PCa patients, subdivided in High (I) and Low Risk (II) groups according to D’Amico classification and five negative patient controls (III group), were tested. Results: All patients of II group defined by PCa with disease properly controlled by therapy, were diagnosed as negative by AdnaTest. Whereas, within the group I, AdnaTest effectively identified as positive patients unresponsive to first- or second-line therapy and as negative patients, although unresponsive to hormone therapy, were responsive to first- or secondline chemotherapy. Briefly, blood samples of three PCa patients belonging to group I, resulted positive for at least one tumor-associated marker (PSA) and 2 out of 3 showed signal for PSMA mRNA. We underline that a patient (Group I), negative for AdnaTest during the firstline of chemotherapy, after few months, became positive for PSA marker. Conclusion: Multiplex PCR developed by Adnagen, represents a useful alternative method for the detection of prostate CTCs. Detection of three markers could potentially be used as a prognostic indicator of aggressive prostate cancer. Therefore, the presence of CTCs reported in prostate cancer patients provides novel opportunities for monitoring the efficacy/resistance to targeted therapy. 44° Congresso Nazionale SIBioC - Riassunti Poster P011 DETECTION OF CIRCULATING TUMOR CELLS ON THE BASIS OF CYTOMORPHOLOGY, IMMUNOFLUORESCENCE AND IN SITU HYBRIDIZATION WITH THE AID OF A ROBOTIZED MICROSCOPE: FROM BENCH TO BED SIDE 1 1 1 P012 EX VIVO EFFECT OF VARESPLADIB ON SECRETORY PHOSPHOLIPASE ALVEOLAR ACTIVITY IN INFANTS WITH ARDS L. Gentile, A. Minucci , D. De Luca, M. Piastra, F. Vendittelli, B. Giardina, G. Conti, E. Capoluongo 2 S. Gabba , T. Dorji , V. Grazioli , A. Albini 1 Lab. Biologia Molecolare, Centro Diagnostico Italiano, Milano 2 IRCCS Multimedica, Milano Introduction: Cancer continues to be a leading cause of death among the industrialized countries and metastases are the most important factor causing the adverse prognosis of carcinoma patients. Cancer cells can detach and disseminate in the blood stream from the primary tumor during tumor progression and the detection of rare circulating tumor cells (CTCs) in patients is useful to monitor the progression and assess response to treatment. CTCs have been detected in a majority of epithelial cancers, including those from breast, prostate, lung and colon both before the primary tumor is detected and even when the carcinoma recurs. Currently, the methods for detecting CTCs include cytometric and nucleic acid based approaches. In our laboratory we use a filtration-based technique to isolate CTCs preserving the cellular shape and morphology and we develop an assay that combines enumeration and genotyping of CTCs, based on a combination of antibody detection, FISH and automated fluorescence microscopy. Material and methods: The assay comprises cell enrichment, by filtration through an 8 μm pores membrane and immunofluorescent staining for the detection of the epithelial marker EpCAM (AUA1), cytokeratins 7 and 8 (CAM 5.2) and CD45 for the negative selection of leukocytes. We also use a combination of FISH probes for the detection of cancer-related genes. The images acquisition is performed with the Ikoniskope robotic microscopy, a fully automated image acquisition and display system specific for rare cell identification. Results and conclusions: We spiked into the blood of a healthy donor a known number of cells of the prostate carcinoma cell line LNCaP and processed the samples through the filtration and detection protocol. We were able to collect/detect the CTCs with high sensitivity and specificity. Maintaining the integrity of the tumor cells detected, our method allows further analysis of cell morphology and genotype. The combination of antibodies and FISH probes, and the possibility of the morphological evaluation, has the potential to provide valuable information and it is very promising for screening, early detection of recurrence/relapse and evaluation of treatment response. Negin BP, Cohen SJ. Circulating tumor cells in colorectal cancer: past, present and future challeges. Curr Treat Options Oncol 2010;11:1-13. Lab. di Biologia Molecolare Clinica, Istituto di Biochimica e Biochimica Clinica, Osp. Gemelli, Roma Background: Secretory phospholipases A2 constitute a group of enzymes responsible for surfactant phospholipids catabolism and release of inflammatory mediators. A wide body of literature suggests that both catabolic and proinflammatory action of sPLA2 enzymes might affect lung function, causing acute respiratory distress syndrome (ARDS). In fact, sPLA2 is responsible for a vicious cycle characterized by surfactant loss, which increases lung tissue inflammation, which leads to type II pneumocyte apoptosis and to additional surfactant dysfunction. Varespladib is a potent indolebased sPLA2 inhibitor that was optimized by structurebased drug design to inhibit some pulmonary isotypes of this enzyme (especially sPLA2-IIA, sPLA2-V and sPLA2X). The molecule acts as an anti-inflammatory agent by disrupting the first step of the arachidonic acid pathway of inflammation. Methods: sPLA2 total activity was measured in bronchoalveolar lavage (BAL) using a colorimetric method (Assay Designs). BAL specimens were subdivided in 4 aliquots each with increasing varespladib concentration (10#M, 40#M, 100#M) or an equal volume of 0.9% saline solution (basal). Results: An overall significant difference (p<0.0001) was found among sPLA2 activity in basal conditions [37.7 (31.8-48.5) IU/mL] and after addition of increasing varespladib concentrations: 10 μM [34.1 (24.9-42.5) IU/ mL], 40 μM (28.4 (25.5-32.3) IU/mL] and 100 μM [7.7 (5.4-12.5) IU/mL]. Discussion: Varespladib is able to inhibit the enzymes of the human secretory phospholipase groups IIa, V and X activities. In fact, it inhibits ex vivo sPLA2 in BAL at 10, 40 and 100 μM, showing an inverse correlation between enzyme activity and varespladib concentrations. Conclusions: Varespladib significantly inhibit sPLA2 providing efficacious enzyme and tissuespecific anti-inflammatory action at lung level, blocking surfactant catabolism, increased lung compliance, and reduce both inflammation of the tissues and the migration of fibroblasts. biochimica clinica, 2012, vol. 36, n. 6 477 44° Congresso Nazionale SIBioC - Riassunti Poster P013 FAMILIAL HYPERCHOLESTEROLEMIA: IDENTIFICATION OF A NEW MUTATION IN THE PCSK9 GENE 1 1 P014 GENOTYPE-DEPENDENCY OF BUTYRATE EFFICACY IN CONGENITAL CHLORIDE DIARRHEA: A COMPARISON BETWEEN IN VIVO AND EX-VIVO STUDY 2 A. Ruotolo , M.N. D'Agostino , M.D. Di Taranto , A. 1 3 3 3 D'Angelo , G. Marotta , M. Gentile , P. Rubba , G. 1 Fortunato A. Elce , S. Giordano , M. Scorza , F. Amato , G. 2 3 1 Terrin , R. Berni Canani , R. Tomaiuolo 1 1 1 1 1 1 CEINGE S.C.a r.l. Biotecnologie Avanzate, Napoli, Italy and Dip. di Biochimica e Biotecnologie Mediche, Università degli Studi di Napoli Federico II, Napoli, Italy 2 Fondazione IRCCS SDN, Napoli, Italy 3 Dip. di Medicina Clinica e Sperimentale, Università degli Studi di Napoli Federico II, Napoli, Italy CEINGE-Biotecnologie Avanzate e Dip Biochimica e Biotecnologie Mediche, Università di Napoli Federico II 2 Dip Ginecologia, Ostetricia e Medicina Perinatale, Università di Roma La Sapienza 3 Dip di Pediatria e European Laboratory for the Investigation of Food Induced Diseases, University of Naples Federico II Introduction: Familial hypercholesterolemia (FH), characterized by high levels of total and LDLcholesterol and premature coronary heart disease (CHD), is associated with mutations in three genes: LDL receptor (LDLR), apolipoprotein B (APOB) and proprotein convertase subtilisin/kexin9 (PCSK9). The most frequent mutations were identified in the gene LDLR, whereas mutations in the APOB and PCSK9 genes are rare and therefore these genes are not included in the most used screening procedures. Our aim is to identify mutations in the PCSK9 gene in order to establish their frequency and utility in genetic screening. Materials and methods: We recruited 197 unrelated patients from Southern Italy with a clinical diagnosis of FH. Through PCR amplification and direct sequencing we search for mutations in the exons and the exon-intron regions of the LDLR and PCSK9 genes. Conservation of substituted aminoacid across the different species was assessed by BLAST alignment. To predict whether a substitution affected protein function we using 4 different algorithms, SIFT (http:// sift.jcvi.org), PMut (http://mmb.pcb.ub.es/), Mutation Taster (http://www.mutationtaster.org) and Poly-Phen2 (http://genetics.bwh.harvard.edu/pph2). Results: Among 197 patients with a clinical diagnosis of FH, mutations in the LDLR gene result absent in 60 patients, in which we found only one variation in PCSK9 gene that represent 0.5% of total patients and 1.7% of patients without mutations in LDLR gene. This is a new genetic variant (c.1394C>T) that causes the aminoacid substitution p.Ser465Leu. This variant was absent in 188 chromosomes from healthy subjects. The serine at the position 465 was conserved in the 20 analyzed species. In silico analysis revealed that the substitution is “Not tolerated”, “Pathological”, “Probably damaging” and “Disease causing” according to the algorithm SIFT, PMut, Poly-Phen and Mutation Taster respectively. The patient shows increased levels of total cholesterol (447mg/dL) and of LDL- cholesterol (328mg/dL) even under therapy. Conclusions: The new PCSK9 variant that we identified contributes to FH phenotype. Our results suggest that the screening of mutations in PCSK9 gene should be taken into consideration for FH disease, although the frequency of mutated patients is low. Congenital chloride diarrhea (CLD) is an autosomal recessive disorder characterized by life-long, severe diarrhea with intestinal Cl- malabsorption resulting from a reduced activity of the down regulated in adenoma exchanger (DRA). Disease is determined by mutations in the solute carrier family 26, member 3 (SLC26A3) gene. Currently available therapies are not able to limit the severity of diarrhea in these patients. Conflicting results have been reported on the therapeutic efficacy of oral butyrate, a short chain fatty acid acting as histone deacetylase inhibitor. We investigated the effect of butyrate (100 mg/kg/day) in seven CLD children with different SLC26A3 genotypes. Molecular analysis was performed in the laboratory of CEINGE-Biotecnologie Avanzate. Nasal epithelial cells were obtained by brushing of inferior turbinates in order to study the effect of the different kind of mutations on DRA functionality and to assess the effect of butyrate on the expression of the two main Cl- transporters: DRA and Putative Anion Transporter-1 (PAT-1). Cells were treated with 5 mM of sodium butyrate for 24 hours. RNA was extracted and retro-transcribed in cDNA for downstream applications. Expression levels of either SLC26A3 and SLC26A6 from treated and untreated cells were measured by semiquantitative real-time PCR on LightCycler 480 Real-Time PCR System with Taqman chemistry. Levels of SLC26A3 and SLC26A6 expression before and after treatment were compared in order to establish the changes determined by butyrate exposure. Butyrate was able to significantly improve the SLC26A3 (DRA) and SLC26A6 (PAT1) gene expression in nasal epithelial cells in 5 out of 7 patients. A variable clinical response to butyrate was observed regarding the stool pattern and fecal ion losses. The best clinical response was observed in subjects with SLC26A3 missense mutations that permit to the protein to reach cell membrane, and in which butyrate induces the SLC26A3 overexpression. This study revealed that butyrate may contribute to CLD therapy in a subset of patients and the study of butyrate effect in nasal cells from CLD patients may be helpful to predict the clinical response. Grants from Regione Campania (DGRC 1901/09) are gratefully acknowledged. 478 biochimica clinica, 2012, vol. 36, n. 6 44° Congresso Nazionale SIBioC - Riassunti Poster P015 HIGH RESOLUTION MELTING ANALYSIS (HRMA) FOR RAPID GENOTYPING OF ANGIOTENSINCONVERTING ENZYME (ACE) INSERTION/ DELETION (I/D) POLYMORPHISM P016 IDENTIFICATION OF A NOVEL VARIANT T4G IN THE PROMOTER 4G/5G REGION OF THE PAI-1 GENE G. Canu, A. Minucci, S. Palumbo, L. Gentile, C. Zuppi, B. Giardina, E. Capoluongo Dip Biochimica e Biotecnologie Mediche, Università di Napoli Federico II e CEINGE-Biotecnologie Avanzate scarl Laboratory of Clinical Molecular Diagnostics, Institute of Biochemistry and Clinical Biochemistry, Catholic University of Rome, Italy Background: In the renin-angiotensin system, ACE is a peptidyldipeptide hydrolase that plays a role in the conversion of angiotensin I into the active octapeptide angiotensin II as well as inactivates the vasodilator bradykinin. In human, the levels of plasma and cellular ACE are strongly determined genetically. Several studies have shown that approximately 50% of the variability of plasma ACE between individuals is the results of an insertion/deletion (I/D) polymorphism in intron 16 of the ACE gene. The I and D alleles differ for the presence or absence of a 287 bp Alu sequence DNA fragment. The ACE I/D polymorphism is generally analyzed by conventional PCR technique. However, it usually involved multiple steps and is time-consuming. Methods: We report here the set-up of a single-tube HRMA method for the detection of ACE gene I/D polymorphism. This method takes advantage of the presence of the 287 bp DNA fragment for the melting curve analysis of PCR amplicons associated to three genotypes (I/I, I/D, D/D). Primers’ design (three primers: two external to 287 bp Alu sequence and one specific for the insertion) considered the different efficiency of amplification of the allele I than allele D. Results: HRMA was found to be particularly suitable for the identification of ACE gene I/D polymorphism: in fact, 50 samples previously genotyped by conventional PCR and sequencing were 100% concordant with the HRMA results, showing high reproducibility, sensitivity and specificity. Three genotypes were distinguished by normalized/temperature shifted melting curves, and fluorescence difference plots. In addition, each genotype was associated with a single peak, and despite of Alu sequence, no non-specific amplicons were found. Discussion: The development of rapid genotyping technique to assess the ACE I/D polymorphism presented in this study can be important in clinical or research studies and may become the method of choice for epidemiologic studies concerning ACE gene I/D polymorphism. Conclusion: This study confirms the great potential of the HRMA as rapid, closed-tube mutation scanning and it constitutes the first application of this technique to highlight the presence of a DNA fragment insertion characterizing three genotypes. Sayed-Tabatabaei FA, Oostra BA, Isaacs A, et al. ACE polymorphisms. Circ Res 2006;98:1123-33. F. Amato, R. Liguori, R. Di Fiore, S. Quaranta The plasminogen activator inhibitor-1 (PAI-1) is an important regulator of the fibrinolytic pathway. The 4G/5G polymorphism in the PAI-1 promoter is associated with altered PAI-1 transcription. The presence of 4G instead of 5G in the promoter region of the gene is associated with a higher plasma levels of PAI-1 protein. Eriksson et al. (1995) found that the prevalence of the 4G allele was significantly higher in patients with myocardial infarction before the age of 45. We have identified a new 4G/5G allele, in which a T is present instead of a G, changing the region formed by 5G in T plus 4G. This new variant was identified in two women, one young woman with an event of myocardial infarction, the other one in pregnancy. Although both alleles (5G and 4G) bind a transcriptional activator, the 5G allele also binds a repressor protein to an overlapping binding site. In the absence of bound repressor, the 4G allele is associated with an increased basal level of PAI1 transcription. Using TFsearch to try to establish the effect of this new variant on the pattern of transcription factors, we found that the variant T4G profoundly change the type and amount of probable transcription factors respect to both the variant 4G and 5G. To test experimentally this new variant, we cloned a promoter region of PAI-1 gene of 1.6 kb in a reporter system. The first data obtained, although preliminary, show an increased transcriptional activity of the construct carrying the variant T4G respect to both the 4G and 5G. It would be interesting to confirm these data also checking the action of cytokines such as IL1, IL6 or TNF-A, known to have a greater effect on the variant 4G compared to the 5G. biochimica clinica, 2012, vol. 36, n. 6 479 44° Congresso Nazionale SIBioC - Riassunti Poster P021 L’ANALISI MOLECOLARE DI 21 PAZIENTI ITALIANI CON SINDROME DI BARDET-BIEDL INDICA BBS1, BBS2 E BBS10 QUALI PRINCIPALI GENI CAUSATIVI 1 1 1 M. D'Antonio , G. Sauchelli , A.A. Crispo , I.C.M. 1 2 2 1 Tandurella , F. Testa , F. Simonelli , G. Esposito , F. 1 Salvatore 1 CEINGE Biotecnologie Avanzate s.c.a r.l., Napoli e Dip. di Biochimica e Biotecnologie Mediche, Università di Napoli Federico II 2 Dip.di Oftalmologia, Seconda Università di Napoli (SUN) La sindrome di Bardet-Biedl (BBS) è una ciliopatia con coinvolgimento multisistemico caratterizzata dall'associazione tra retinite pigmentosa (>90% dei casi), obesità, polidattilia, alterazioni renali, ipogonadismo e deficit cognitivo. L'espressione clinica è variabile, anche se molti pazienti manifestano quasi tutti i tratti dall’infanzia e tendono ad aggravarsi con l’età. La prevalenza Europea è stimata tra 1/125.000 e 1/175.000. L'ampio spettro clinico osservato nella BBS si associa ad una significativa eterogeneità genetica essendo state identificate mutazioni in 14 geni diversi (BBS1-14). La malattia è trasmessa prevalentemente come carattere autosomico recessivo; in alcuni casi è stata osservata una trasmissione triallelica (BBS1, BBS2, BBS6). Per la messa a punto di una efficace strategia diagnosticomolecolare, abbiamo inizialmente analizzato il DNA genomico di 21 pazienti italiani affetti da BBS, utilizzando il chip della Asper Biotech (Estonia) che ricerca 333 mutazioni note in 12 geni BBS, nel gene ALMS1, e nel gene GNAS1. L’analisi ha evidenziato 11 alleli mutati (3 in BBS10, 6 in BBS1, 2 in BBS6) in 6 pazienti, 5 dei quali sono risultati omozigoti. Sono stati quindi analizzati mediante sequenziamento diretto gli esoni e le relative giunzioni di splicing dei geni BBS10, BBS1, BBS2, BBS6, le cui mutazioni rendono conto, secondo dati di letteratura, rispettivamente del 20%, 23%, 8% e 6% circa dei casi di BBS. Abbiamo così identificato otto nuove varianti di sequenza (62%), tre in BBS10, una in BBS1, e 4 in BBS2. Abbiamo identificato in totale 2 mutazioni in 10/21 pazienti (48%), 1 sola mutazione in 2/21 (10%) e nessuna mutazione in 9 pazienti (43%) per un totale di 14 variazioni geniche differenti. Inoltre, il 19% dei pazienti presenta mutazione di BBS10, il 24% di BBS1, il 10% di BBS2; 1 paziente, composito eterozigote per due nuove mutazioni frameshift in BBS2 è anche eterozigote per una mutazione missenso in BBS1. Tutti i soggetti omozigoti dichiarano consanguineità dei genitori. Lo screening molecolare sarà presto esteso ai rimanenti geni; per i pazienti eterozigoti per una sola variante, sarà valutata la dose genica mediante array CGH. Acknowledgments: Regione Campania, DGRC 1901/2009; IRCCS - Fondazione SDN. 482 biochimica clinica, 2012, vol. 36, n. 6 P022 MANAGEMENT OF REAL MICROBIOLOGICAL EMERGENCIES: REAL TIME PCR PLATFORM AS INTEGRATION TOOL AMONG CLINICAL BIOCHEMISTRY, MICROBIOLOGY AND CLINICAL MOLECULAR BIOLOGY L. Bianchi, Z. Napoli, M. Niccolai, R. Giannecchini, F. Santoni, R. Lari U.O. Lab. di Analisi Chimico Cliniche e Microbiologiche, Az. Osp. di Pistoia Introduction: Meningitis and malaria are medical emergencies that require a multidisciplinary approach and Real Time PCR (RT-PCR) platform increases diagnostic effectiveness, reducing the turn around time (TAT), increasing the sensitivity and, for malaria, standardizing parasitemia. Purpose: The aim of this study was to analyze the impact of RT-PCR in terms of diagnostic efficacy in the management of microbiological "emergencies". Methods: 95 cerebrospinal fluids (CSFs), positive to physical-chemical analysis, and 14 cases of suspected malaria were analyzed with RT-PCR. The nucleic acids were extracted using the extractor EZ1-Advanced and Virus DNA kit (Qiagen). Qualitative/quantitative RTPCR for bacteria (EuSepScreen lattanti/adulti, Eurospital) and viruses (HSV and enterovirus, BioMieraux) were used for the detection of most important pathogens causing meningoencephalitis. Quantitative RT-PCR Artus (Qiagen) and Liferiver (DID) kits were used for detecting and typing Plasmodium species. Results: 9 CSFs analyzed were positive for bacteria (4 to S. pneumoniae: 2 with negative bacterioscopic analysis and 3 with negative culture) and 11 for viruses (including 1 to HHV-7). All positive bacterial cases showed a procalcitonin (PCT) increase. There were no cases with negative molecular test and positive culture test. The malaria RT-PCR has confirmed all positive cases (n = 6) of thin blood smears (TBS), including the only case with gametocytes alone. RT-PCR parasitemia was comparable to BST one. Conclusion: About CSF: 1) evaluation of biochemical test results such as PCT and blood count allow to decide which RT-PCR panel is more appropriated; 2) a fully automated platform for RT-PCR methods can provide a more effective response in terms of treatments. In fact, RT-PCR methods are faster (TAT <2-3h), more sensitive(<99%) and VPN is 100%. In addition, RTPCR allow many viral pathogens detection, reducing the cases in which therapy remains on empirical basis. Limits? The reduced number of pathogens, especially bacteria, that can be detected. For malaria diagnosis RT-PCR improves identification of Plasmodium species and allows standardization of parasitemia calculation, making it suitable for its insertion in urgency/routines, with important clinical relapses for the patients. 44° Congresso Nazionale SIBioC - Riassunti Poster P023 MANNOSE-BINDING LECTIN2 GENE FUNCTIONAL POLYMORPHISMS ANALYSIS IN ITALIAN PATIENTS WITH AGE-RELATED MACULAR DEGENERATION: A PRELIMINARY STUDY 1 1 2 P024 METODOLOGIE PER L'IDENTIFICAZIONE DI POLIMORFISMI NEL GENE hHCN4 M. Carboni, V. Bulla , F. Pudda, E. Canu , S. Pasella, P. Mele, A. Marchisio, F. Balzano, A. Mannu, L. Deiana 2 E. Mello , P. Concolino , B. Falsini , A.M. Minnella , F. 1 1 1 1 Annunziata , C. Zuppi , B. Giardina , E. Capoluongo 1 Laboratory of Clinical Molecular Diagnostics, Institute of Biochemistry and Clinical Biochemistry, Catholic University of Rome 2 Institute of Ophtalmology, Catholic University of Rome Background: Age-related macular degeneration (AMD) is the leading cause of blindness in the elderly population living in developed countries; in late stage it includes two forms: “dry” and the most severe “wet”. AMD is a multifactorial disorder where some variants in genes encoding complement pathway proteins have been associated with AMD. Mannose Binding Lectin (MBL) is an important component of the innate immune system. MBL’s recognition of microorganism or endogenous apoptotic cells facilitates their clearance through opsonophagocitic pathways. Expression levels of functional MBL are strongly genetically determined. In this study we investigated MBL2 polymorphisms as potentially associated with AMD. Moreover MBL2 could help to discriminate between two forms of AMD: wet and dry. Methods: 85 nonsmokers Caucasian patients (39 DryAMD and 46 Wet-AMD) were genotyped for three polymorphisms in the promoter of MBL2 gene (-550H/ L, -221X/Y, +4P/Q variants) and for three major mutant alleles in exon 1 (p.R52C, p.G54D, p.G57E). In addition 55 healthy control subjects were genotyped. Results: MBL-2 SNP frequencies were not significantly different between patients and controls (p>0.01). By haplotype analysis, the largest differences were found in Wet-AMD group vs Dry and controls (p<0.05). LYPA and HYPD haplotypes frequencies were lower in Wet-AMD, whereas HYPA frequency was higher. Discussion: MBL2 could be involved in AMD pathogenesis: in fact, LYPA and HYPD haplotypes, who correlate with a medium promoter activity and produce a non-functional protein respectively, seem to be protective towards progression from Dry to Wet-AMD. Besides HYPA, that synthesizes a wild-type protein with high activity of promoter, is more distributed in Wet-AMD than in control or Dry individuals. We can hypothesize that higher active MBL circulating protein, as a consequence of the presence of MBL2 genotype, could result in a higher complement activation and MBL-dependent cell mediated citotoxicity at macular level, that could lead to AMD onset. Therefore lower active MBL circulating protein could be protective in AMD progression. Study on large population will clarify the role of MBL2 polymorphisms in AMD development and progression. Dinu V, Miller PL, Zhao H. Evidence for association between multiple complement pathway genes and AMD. Genet Epidemiol 2007;31:224-37. Biochimica Clinica e Biologia Molecolare Clinica, Dipartimento Scienze Biomediche, Facoltà di Medicina e Chirurgia, Università degli Studi di Sassari É stato dimostrato che il battito del cuore è provocato da un solo gene detto hHCN4 o gene “pacemaker”, che sarebbe il grado di azionare del meccanismo della pompacuore controllandone la frequenza cardiaca. hHCN4 gestisce in maniera diretta una proteina che agisce da canale ionico, detto canale “funny” o canale del pacemaker, tale gene è molto espresso nei mammiferi nel nodo seno-atriale. Nei roditori una riduzione del gene hHCN4 determina bradicardia e la sua eliminazione porta a rallentamento del ritmo fino alla morte. Il DNA genomico di soggetti bradicardici di origine sarda che hanno superato i cento anni di età, appartenenti al progetto AKeA, è stato estratto da sangue intero e il gene hHCN4 amplificato tramite PCR. Gli amplificati dei diversi esoni sono stati quindi analizzati mediante l’utilizzo del DHPLC, tecnica che permette di identificare polimorfismi in una sequenza. Il DNA usato come standard, appartiene ad un unico individuo non bradicardico, è stato amplificato tramite PCR, sequenziato e confrontato con il gene wild type per determinare eventuali variazioni nella sequenza genomica. Lo studio è in fase preliminare. I risultati ottenuti sono in numero limitato per un’analisi statistica. Lo studio preliminare condotto su soggetti ultralongevi bradicardici ha evidenziato al momento la presenza di polimorfismi sinonimi che non influiscono sulla funzionalità del canale “funny”. Tali risultati rappresentano i primi dati di uno studio più ampio. Milanesi R, Baruscotti M, Gnecchi-Ruscone T, et al. Familial sinus bradycardia associated with a mutation in the cardiac pacemaker channel. N Engl J Med 2006;354:151-7. biochimica clinica, 2012, vol. 36, n. 6 483 44° Congresso Nazionale SIBioC - Riassunti Poster P025 MiRNAs EVALUATION IN HUMAN PERIPHERAL BLOOD CELLS OF CELIAC PATIENTS 1 2 1 M. Capuano , M. Galatola , M.V. Esposito , L. Del 1 1 3 1 Vecchio , L. Sacchetti , L. Greco , N. Tinto 1 Dep. of Biochemistry and Medical Biotechnology, University of Naples “Federico II”, and CEINGE Advanced Biotechnology, s. c. a r. l., Naples 2 Dep. of Biochemistry and Medical Biotechnology, University of Naples “Federico II”, and Dep. of Paediatrics and European Laboratory for the Investigation of Food-Induced Diseases (ELFID), University of Naples “Federico II”, Naples 3 Dep. of Paediatrics and European Laboratory for the Investigation of Food-Induced Diseases (ELFID), University of Naples “Federico II”, Naples Celiac disease (CD) is an immune mediated enteropathy caused by permanent sensitivity to gluten in genetically susceptible individuals. HLA DQ2/DQ8 haplotypes confer the highest estimated heritability (~35%) reported so far; however, the presence of HLA-risk alleles is a necessary but not sufficient condition for the development of CD. In the last four years, several Genome Wide Association studies identified about 40 genomic regions harboring 64 candidate genes, but unfortunately they account for only 4% of the genetic variance. A recent study of our group focused on the involvement of microRNAs (miRNAs) in the intestinal epithelium of the human CD small intestine. MiRNAs are small non-coding RNAs that modulate gene expression, causing an inhibition of translation or some degree of degradation of the target mRNA. They play a relevant role in a variety of physiological and pathological conditions. In a previous study we found that, among 365 human miRNAs tested, the expression of about 20% of the miRNAs differed between CD and control children, particularly miR-449a showed the higher expression levels in CD patients. In this study, we evaluated the expression of miR-449a in peripheral blood cells of CD patients aimed to identify a new easy and non-invasive diagnostic tool of the disease. For this purpose, we recruited 40 children, 20 active CD, 10 Gluten Free Diet (GFD) CD and 10 controls. From all participants 2 blood samples with EDTA were collected. Peripheral lymphocytes were sorted using Fluorescenceactivated cell sorting (FACS) and peripheral monocytes were isolated by Macs cell isolation kit (Miltenyi Biotec). Total RNA was extracted from both lymphocytes and monocytes. The expression level of the miR-449a, in each cell population, was evaluated by quantitative RTPCR using RNU48 as endogenous control. Preliminary data show that the miR-449a expression was similar in lymphocytes but lower in monocytes from CD than from controls. Further studies are in progress to test the correlation among expression level of miR-449a in intestinal mucosa and in peripheral monocytes of the same CD patients in order to investigate if the miR-449a evaluation in monocytes could be useful in CD diagnosis. 484 biochimica clinica, 2012, vol. 36, n. 6 P026 MOLECULAR ANALYSIS OF PATIENTS WITH ELEVATED LONG-CHAIN 3-OH-ACILCARNITINES ALLOWS DIFFERENTIAL DIAGNOSIS BETWEEN LCHAD AND MTP DEFICIENCY 1 1 1 R. Romanelli , C. Cozzolino , E. Scolamiero , G. 1 3 1 1 Parenti , G. Andria , M. Ruoppolo , G. Frisso , F. 2 Salvatore 1 Dip. di Biochimica e Biotecnologie Mediche, Università degli Studi di Napoli “Federico II” 2 CEINGE-Biotecnologie Avanzate scarl, Napoli 3 Dip. di Clinica Pediatrica, Università degli Studi di Napoli “Federico II” The mitochondrial trifunctional protein (MTP) is a multienzyme complex of the fatty acid beta-oxidation cycle. It is composed of 4 #-subunits (encoded by HADHA) harboring long-chain 2,3 enoyl-CoA hydratase (LCEH) and long-chain L-3-hydroxyacyl-CoA dehydrogenase (LCHAD) activity, and 4 β-subunits (encoded by HADHB) harboring long-chain 3-ketoacyl-CoA thiolase (LCKT) activity. MTP deficiency is an autosomal recessive disorder distinguished in two diseases: isolated LCHAD deficiency (LCHADD), characterized by reduced LCHAD activity, and general MTP deficiency (MTPD), characterized by reduced activity of all three MTP enzymes. Here, we report two patients, for which plasma acylcarnitine profile analysis by tandem mass spectrometry (LC-MS/MS) showed an increase of long-chain 3-hydroxy species: 3-OH-palmitoylcarnitine (C16OH) and 3-OH-oleylcarnitine, (C18:1OH). These findings suggested either long-chain 3-hydroxyacyl-coA dehydrogenase deficiency (LCHADD) or complete MTP deficiency. By molecular analysis of the HADHA and HADHB genes, the patient 1 revealed homozygosity for the common #-subunit mutation c. G1528C (p.E510Q), that is located directly within the catalytic region of the LCHAD domain and is present in homozygous form in about 70% of affected individuals. This result is consistent with LCHADD diagnosis. Patient 2 was found to be a compound heterozygote for 2 novel mutations in HADHB gene: c.A284G (p. T62A), absent in 600 normal chromosomes, and c. 358+1 G>A, resulting in the skipping of exon 5 with an in-frame 44-bp deletion, suggesting MTP deficiency. In conclusion, we emphasize the importance of genetic analysis for a correct differential diagnosis of diseases that show overlapping biochemical findings, such as LCHADD and MTPD. This is very important for the accurate genetic counseling. 44° Congresso Nazionale SIBioC - Riassunti Poster P027 MULTIPLEX REAL TIME PCR ALLELIC DISCRIMINATION OF G1691A (LEIDEN MUTATION) AND G20210A (FACTOR II) MUTATIONS ON Q3 SIMPLE PLATFORM FROM BUCCAL SWAB WITHOUT EXTRACTION 1 1 P028 MULTIPLEX REAL TIME PCR EVALUATION OF GENETIC CELIAC DISEASE PREDISPOSITION (HLA-DQ2 AND HLA-DQ8) IN 102 CASES AND RELATIVE CORRELATION WITH HLA-DRB1 HAPLOTYPE INVESTIGATED BY REVERSE DOTBLOT HYBRIDIZATION 1 M. Valisi , A. Colombo , D. Stangalini , A. 2 2 3 Donnangelo , A. Marzorati , S. Coffa , M. 3 3 2 Bianchessi , S. Conoci , D. Russo 1 1 2 M. Valisi , A. Colombo , A. Donnangelo , A. 2 1 1 2 Marzorati , D. Stangalini , A. Stangalini , C. Roccio , D. 2 Russo 1 Fleming Research Service Lab, Milano Clonit, Milano 3 ST Microelectronics, Agrate 2 Hereditary thrombophilia is a genetically determined tendency to develop thromboembolic disease at a young age with recurrent character. Environmental risk factors (smoking, alcohol, stress, diet, etc.) and genetic mutations such as the Leiden mutation localized on the factor V gene and the mutation G20210A Prothrombin gene located on or factor II, interact resulting in the expression of this disease. This study was performed by multiplex TaqMan real-time PCR that allows the simultaneous amplification and characterization of the Factor V (G1691A) and Factor II (G20210A) specific SNPs on Q3 system; an innovative platform developed by ST Microelctronics in collaboration with Clonit. It is presented as a ready to use “samplein, result out” tool where the reagents (Clonit) are preloaded. This small and single assay system uses a silicon microchip that allows the simultaneous amplification of the heterozygous positive controls, negative controls, and the sample for both mutations: one sample for one chip. The reaction starts directly from buccal swab and it doesn’t need any kind of DNA extraction. Buccal swab from 30 random patients have been analyzed by the new ST platform and compared with whole blood extracted DNA at Fleming Research Service Lab using QIACube instrument and amplified by AB7500 using commercial reagents (Clonit). The final results performer simultaneously on both systems (Q3 without extraction and conventional instrumentation by reference reagents with standard extraction) performed simultaneously have demonstrated the perfect correlation. The implementation of this new real time platform allows reducing the time analysis and the cost of the assay. Morover, it’s able to perform appropiately the tests also in not specialized labs with small number of samples or in POC, since the microchip concept allows single sample analysis without both any reagents waste and the external extraction that currently requires specialized staff. 1 Service Lab Fleming Research, Milano Clonit, Milano 2 Celiac disease is a systemic immune disorder characterized by mild to severe gastrointestinal symptoms (such as diarrhea, weight loss, abdominal pain, abdominal distention, etc). This disease is a multifactorial disorder resulting from the interaction of specific pairs of allelic variants in two HLA genes, HLA-DQA1 and HLA-DQB1, associated with celiac disease susceptibility, and other environmental factors. Because of 30% of the general population has one of the celiac disease-associated HLA alleles and only 3% of individuals with one or both of these alleles develop celiac disease, presence of celiac disease-associated HLA alleles is not diagnostic of celiac disease; however, their absence excludes a diagnosis of celiac disease. The loci within the DRDQ region are especially valuable for their tight linkage and high linkage disequilibrium. The HLA-DRB1 gene is very important to identify the presence of homozygous or heterozygous alpha or beta chain in DQ-heterodimer and the susceptibility to celiac disease. This study was performed by multiplex TaqMan real-time PCR (Clonit srl) that allows the simultaneous amplification and characterization of the specific allele variants of DQA1 (DQA1*02 , DQA1*03 and DQA1*05) and DQB1 (DQB1*02 and DQB1*0302 ) in 102 Italian patients; all these celiac disease associated HLA alleles are necessary to allow the determination of the presence of DQ2-heterodimer or DQ8-heterodimer. We have also characterized the HLA-DRB1 haplotype of every patients, both the carriers of DQ2-/DQ8-heterodimer or not, with a reverse dot-blot hybridization (Innogenetics srl) to allow differentiation of homozygotes from heterozygotes carriers of risk alleles and cis-position on the DR3DQ2 haplotype from trans-position DR5-DQ7/DR7-DQ2 in heterozygotes carriers. The evaluation of 102 random samples shows that 40% of the tested patients (N=39) presents genetic predisposition to celiac disease. 33% (N=13) of these predisposed samples present only the DQ2 ß chain, 41% (N=16) has got the allelic variants of HLA-DQ2, 17% (N=7) expresses the allelic variants of HLA-DQ8 and 9% (N=3) is characterized by the two HLA genes allelic variants of HLA-DQ2 and HLA-DQ8. The final results obtained from both analysis (real time and reverse dot blot) performed simultaneously have demonstrated the correlation between the HLA-DQ2/DQ8 expression and HLA-DRB1 haplotype. biochimica clinica, 2012, vol. 36, n. 6 485 44° Congresso Nazionale SIBioC - Riassunti Poster P029 MUTATION ANALYSIS OF SARCOMERIC GENES IN HYPERTROPHIC CARDIOMYOPATHY FAMILIES FROM SOUTHERN ITALY 1 1 3 1 S. Zanotta , P. Coppola , G. Limongelli , G. Frisso , F. 2 Salvatore 1 Dip. di Biochimica e Biotecnologie Mediche, Università degli Studi di Napoli "Federico II", Napoli 2 CEINGE-Biotecnologie Avanzate scarl, Napoli 3 Dip. di Cardiologia, Seconda Università di Napoli, A.O. Monaldi, Napoli Hypertrophic cardiomyopathy (HCM) is the most common genetic cardiovascular disorder characterized by thickening of the left ventricular wall and potentially fatal arrhythmias. It is the most frequent cause of sudden cardiac-related death in young people and a major cause of cardiac failure and death in the elderly. However,HCM frequently goes undiagnosed until the appearance of overt signs and symptoms. Genetic screening of HCM patients allows to obtain information useful for an early diagnosis and so limit the severe consequences of silent HCM[1]. Mutations in 8 or more genes encoding proteins of the cardiac sarcomere are responsible for HCM, such as MYH7, MYBPC3 and TNNT2. We analyzed, by PCR and direct sequencing, 93 independent HCM patients from Southern Italy for MYH7, MYBPC3, TNNT2, TNNI3, TPM1, MYL2, MYL3 and ACTC1 genes. We also analyzed 119 subjects from 31 HCM families to evaluate the mutation segregation in the family. Mutations were identified in 47 of 93 patients (50%). The most frequent genes altered in the genotyped patients were MYH7 and MYBPC3, which were mutated in 43% and 42% of genetic positive cases, respectively. Genes TNNT2, TPM1 and TNNI3 were altered in 11% and 2% of cases,respectively. We found 11 novel mutations: 6 in MYBPC3, 4 in MYH7 and 1 novel mutation in TNNT2. 5 patients at HCM end-stage phase had double mutations: 2 had double mutations in MYBPC3 gene, and 1 patient had 2 mutations in MYH7 gene;the other were compound heterozygous, harboring 1 mutation in MYH7 and 1 in MYBPC3 genes and 1 mutation in MYH7 and 1 in TPM1 genes. 70(59%) family subjects, of whom 26 were asymptomatic, carried a mutation. Our data agree with HCM molecular epidemiology present in the literature, reporting genes most frequently associated with HCM are MYH7, MYBPC3 and TNNT2. In our cohort complex genotypes, characterized by double mutations, were present in HCM end-stage patients, suggesting that genetic screening may play a role in the identification of HCM patients at risk of disease progression. Molecular screening of first-degree resulted very important for characterize family members at risk for developing disease and excluding unaffected relatives, which is information not achievable otherwise. Maron BJ, Maron MS, Semsarian C. Genetics of hypertrophic cardiomyopathy after 20 years: clinical perspectives. J Am Coll Cardiol 2012;60:705-15. 486 biochimica clinica, 2012, vol. 36, n. 6 P030 POLIMORFISMO DEL GENE ACE: GENE DELLA LONGEVITA’ O FATTORE DI RISCHIO NELLA PATOLOGIA IPERTENSIVA B. Lo Sasso, A. Caruso, L. Agnello, F. Bazza, G. Pecoraro, V. Randazzo, M. Ciaccio Dip. di Biopatologia e Biotecnologie Mediche e Forensi, Sez. di Biochimica Clinica e Medicina Molecolare, Università degli Studi di Palermo. Negli ultimi decenni l’allungamento della vita media ha stimolato un particolare interesse nello studio dei processi dell’invecchiamento e nella ricerca di possibili geni coinvolti nella longevità. In particolare i centenari dimostrano di avere una prevalenza minore di malattie cardiovascolari e dei fattori di rischio ad essa correlati. L’enzima di conversione dell’angiotensina (ACE), presente in tutte le cellule endoteliali, gioca un ruolo essenziale nel mantenimento dell’omeostasi del flusso vascolare, regolando sia la produzione del vasocostrittore angiotensina II sia inattivando la bradichinina. In particolare alcuni studi hanno riportato una possibile correlazione tra il polimorfismo Inserzione/ Delezione (I/D) localizzato all’interno dell’introne 16 del gene ACE e la patologia ipertensiva nonché un suo possibile ruolo nella longevità. Lo studio è stato condotto su 200 soggetti di età >90 anni provenienti dalla Regione Sardegna, 123 pazienti ipertesi (24-76 anni) e 112 soggetti normotesi (30-65 anni). Il polimorfismo (I/D) è stato tipizzato mediante PCR; gli amplificati di 490bp (allele I) e di 190bp (allele D) sono stati visualizzati su gel di agarosio al 2%. I nostri risultati mostrano una frequenza del genotipo D/D maggiore nei soggetti ipertesi rispetto ai soggetti normotesi (49% vs 36%, P = 0.027) e maggiore nel gruppo dei centenari sia rispetto ai soggetti ipertesi che normotesi ( 52% vs 49%, P = 0.016; 52% vs 36% , P < 0.01 ). Sebbene il ruolo del gene ACE nel processo della longevità e nella patogenesi delle malattie cardiovascolari rimanga controverso, il nostro studio suggerisce una possibile associazione tra longevità e varianti alleliche di geni coinvolti nella patogenesi dell’ipertensione. 44° Congresso Nazionale SIBioC - Riassunti Poster P031 PROTHROMBOTIC GENE VARIANTS IN AMI YOUNG WOMEN 1 1 2 P032 SCREENING DI MUTAZIONI BETA-TALASSEMICHE MEDIANTE ANALISI DI TIPO HIGH RESOLUTION MELTING (HRMA) 2 S. Giordano , R. Tomaiuolo , C. Bellia , A. Caruso , R. 1 1 3 3 Di Fiore , S. Quaranta , D. Noto , A.B. Cefalù , P. Di 4 5 3 2 Micco , F. Zarrilli , M. Averna , M. Ciaccio C. Di Mauro, S. Puzone, M.R. Storino, R. Sessa, P. Izzo, M. Grosso 1 Dip. di Biochimica e Biotecnologie Mediche, Universita’ degli Studi di Napoli Federico II e Ceinge-Biotecnologie Avanzate, Napoli CEINGE-Biotecnologie Avanzate e Dip Biochimica e Biotecnologie Mediche, Università di Napoli Federico II 2 Sez di Biochimica Clinica e Medicina Molecolare, Dip Biopatologia e Biotecnologie Mediche e Forensi, Università di Palermo 3 Centro per le Dislipidemie Genetiche-Dip di Medicina Interna e Specialistica, Università di Palermo 4 Pronto Soccorso, Unità di Medicina Interna, Osp Fatebenefratelli di Napoli 5 Dip. Bioscienze e Territorio, Università del Molise, Isernia Given its high incidence, morbidity and mortality, acute myocardial infarction (AMI) is a relevant clinical and social problem particularly in young women. 10% of AMI occurs in subjects aged <45 years, (juvenile AMI) independently of the presence of typical risk factors, suggesting that genetic predisposition plays a relevant role. Some variants in genes encoding inhibitors of hemostasis have a procoagulant effect, predisposing to venous thrombosis, but their role in arterial diseases is still controversial. The most common prothrombotic variants are: factor V (FV) Leiden, which causes resistance to protein C; prothrombin (FII) G20210A, that causes a higher plasma level of FII; the C677T of methylene-tetrahydrofolate reductase (MTHFR) enzyme which impairs the homocysteine levels; and the -455G>A of beta-fibrinogen which causes increased levels of fibrinogen. The aim of the study was to evaluate the potential link between such gene variants and AMI in young women. The four prothrombotic gene variants were analyzed using a commercial kit based on real-time PCR and light-cycler analyzer in 955 young AMI patients (362 females, 593 males) and in 698 AMI patients (245 females, 453 males). We studied 909 unrelated subjects (458 females, 451 males) from the same geographic area as control group. In young AMI females, the allelic frequency of either FV Leiden and of FII G20210A was significantly higher versus the control group (O.R.: 3.67 for FV Leiden and O.R.: 3.84 for FII G20210A; p<0.001). AMI male patients showed the allelic frequency of the MTHFR C677T variant and the homozygous variant genotype significantly higher as compared to the control population (O.R. 3.05). The data confirm that young AMI in females is a peculiar phenotype with specific risk factors as the increased plasma procoagulant activity of FV and FII. Instead, the homozygous state for the 677T MTHFR variant may cause increased levels of homocysteine and/or an altered folate status and thus an increased risk for later AMI, particularly in males. These observations may contribute to a better stratification of the genetic AMI risk in different age and gender subjects and may help to improve prevention strategies for acute coronary diseases in specific risk-group subjects. Le beta talassemie sono condizioni generalmente associate a mutazioni puntiformi a carico del gene beta globinico. Nel nostro laboratorio abbiamo messo a punto una procedura basata sulla tecnica dell’High Resolution Melting Analysis (HRMA) per l’identificazione di tali mutazioni in 40 portatori di tratto beta-talassemico. La metodica dell’HRMA permette di identificare la presenza di mutazioni puntiformi, piccole delezioni o duplicazioni. La procedura consiste in una reazione di amplificazione e nella successiva determinazione del profilo di denaturazione in un determinato range di temperatura (60-95 °C) che avviene nello stesso tubo di reazione in un termociclatore (LightCycler® 480, Roche Applied Science). Questa caratteristica riduce notevolmente il rischio di contaminazione e di manipolazione del campione. L’intera procedura si presta, inoltre, ad essere automatizzata e può quindi essere eseguita da un unico operatore, riducendo quindi notevolemente i costi del personale preposto a tali indagini. Dall’analisi dei profili di denaturazione è possibile identificare direttamente alterazioni di sequenza nei prodotti di amplificazione grazie al cambiamento della curva di denaturazione rispetto a quella di un controllo normale. Nel nostro studio abbiamo messo a punto le condizioni di reazione per cinque regioni del gene betaglobinico in cui cadono più frequentemente mutazioni beta talassemiche (promotore prossimale, sequenze esoniche ed introniche, regione 3’UTR). In tutti i portatori di tratto beta-talassemico da noi analizzati è stato possibile identificare alterazioni delle curve di denaturazione rispetto ai controlli normali. La presenza di una determinata mutazione puntiforme è stata poi confermata mediante sequenziamento diretto dell’amplicone. Inoltre, questo metodo è risultato altamente riproducibile ed accurato in quanto ciascun tipo di mutazione ha mostrato uno specifico profilo di melting, anche nel caso di mutazioni che cadono in posizioni molto ravvicinate, come le mutazioni IVS1:1 e IVS1:6. Il metodo dell’HMR risulta quindi molto economico, affidabile, rapido ed utilizzabile anche nel corso di diagnosi prenatali. Erali M, Voelkerding KV, Wittwer CT. High resolution melting applications for clinical laboratory medicine. Exp Mol Phatol 2008;85:50-8. biochimica clinica, 2012, vol. 36, n. 6 487 44° Congresso Nazionale SIBioC - Riassunti Poster P035 VARIAZIONE DEI LIVELLI PLASMATICI DI TTR NELLA POPOLAZIONE SARDA S. Pasella, A. Baralla, E. Canu, S. Pinna, A. Mannu , V. Ventura , E. Sotgiu, L. Deiana P036 VITAMIN E SUPPLEMENTATION IN TYPE 2 DIABETIC MELLITUS AND FIBRINOGEN -854 G/ A POLYMORPHISM EFFECTS ON FIBRINOGEN DECREASE 1 Biochimica Clinica e Biologia Molecolare Clinica, Dipartimento Scienze Biomediche, Facoltà di Medicina e Chirurgia, Università degli Studi di Sassari La transtiretina (TTR) è una proteina coinvolta nel trasporto degli ormoni tiroidei e del retinolo A, entrambi ormoni essenziali per la normale crescita e sviluppo di tutti gli organi dell’organismo umano. Dalla letteratura è noto che sono molteplici i fattori che possono causare variazioni dei livelli plasmatici della TTR. Da studi preliminari sulla longevità in Sardegna (Progetto di ricerca AKeA) è emersa l’esistenza di alcune importanti variazioni nell’espressione di diverse proteine plasmatiche; in particolare, è stata osservata una riduzione statisticamente significativa (pvalue<0.05) dell’espressione proteica di TTR in soggetti con età superiore ai 90 anni. Nel presente lavoro si è voluto vedere come variano i livelli plasmatici di TTR utilizzando un metodo quantitativo e se esiste una corrispondenza con i risultati dell’analisi semiquantitativa ottenuti mediante elettroforesi bidimensionale e analisi di immagine. E’ stato esaminato un campione rappresentativo della popolazione sarda composto di 71 individui, di cui 23 centenari (100-104y), 17 novantenni (90-99y), 15 ottantenni (80-89y) e 16 con età inferiore ai 50 anni. La concentrazione plasmatica della TTR è stata valutata mediante il kit Assay Max Human Prealbumin ELISA (Assaypro). I risultati del presente lavoro mostrano una diminuzione significativa (p <0.05) dei valori di concentrazione plasmatica di TTR con l’avanzamento dell’età, in particolare nel gruppo dei novantenni e dei centenari. Il gruppo degli ottantenni mostra invece valori confrontabili a quello con un età inferiore ai 50 anni. Inoltre, suddividendo ulteriormente ogni fascia d’età per sesso è emerso che le concentrazioni di TTR nel plasma sono più basse nelle donne rispetto agli uomini. Questi risultati confermano i nostri dati preliminari. In genere bassi livelli plasmatici di transtiretina sono associati a condizioni di malnutrizione e alla risposta infiammatoria di fase acuta. Il fatto che sia stata osservata la massima significatività statistica nelle diminuzioni della concentrazione di TTR in soggetti centenari e ultracentenari suggerisce la possibilità di un coinvolgimento della proteina nella longevità. Johnson M, Merlini G, Sheldon J, et al. Clinical indications for plasma protein assays: transthyretin (prealbumin) in inflammation and malnutrition. Clin Chem Lab Med 2007;45:419–26. 2 3 2 F. Busco , R. Testa , R. Festa , M. Boemi , A. 1 2 2 1 Marziali , A.R. Bonfigli , M. Cucchi , R. Galeazzi 1 Laboratorio Analisi Chimico-Cliniche e Molecolari, INRCA, Ancona 2 Centro Ricerche Metaboliche sul Diabete e gli Alimenti, INRCA, Ancona 3 Dip. Scienze Cliniche e Molecolari, Università Politecnica delle Marche Aim: Patients with type 2 diabetes mellitus have an increased risk of accelerated atherogenesis and thrombosis. This illness is associated with increased generation of free oxygen radicals (oxidative stress) and pro inflammatory basal status. Diet supplementation with Vitamin E or Vitamin E alone is able to decrease oxidative stress and basal inflammation. Fibrinogen is a crucial acute phase protein involved in the process of thrombus formation, whose plasma levels rise in inflammatory conditions. Fibrinogen levels are also influenced by genetical factors. Two nonrelated polymorphisms in the promoter region of ß fibrinogen gene, -455 G/A and -854 G/A substitution, are known to have a substancial impact on the basal rate of transcription of the gene and, subsequently, on fibrinogen plasma concentration. The aim of this study was to determine the effect of vitamin E treatment on fibrinogen plasmatic levels in diabetic patients and whether these two polymorphisms may influence Vitamin E effect. Methods: Thirty-seven type 2 diabetic patients (24 males and 13 females, mean age±SD, 61.9±6.5 years, mean BMI±SD 28.1±3.4, mean duration of diabetes±SD 5.8±5.6 years) were treated with vitamin E 500 UI/ die. We determined fibrinogen, -455 G/A and -854 G/A polymorphisms and other biological variables at baseline, during (5th and 10th week) and after (30th week) vitamin E supplementation. Results: Fibrinogen drastically decreased after vitamin E supplementation (baseline 365.8±91.1, after 30 weeks 316,1±68.4, p<0.001). Multivariate analyses showed no significant effect of -455 G/A, while significant effect was detected for -854 G/A polymorphism (p=0.043). In particular, contrast test showed a significant effect between baseline and the 30th week (p=0.015).This effect is linked to GA allele whose carriers showed a relevant decrease in fibrinogen levels. Conclusions: These data confirm that vitamin E is able to decrease fibrinogen levels in type 2 diabetes, and show that -854 G/A polymorphism influences fibrinogen decrease. It opens further fields of study, where the evaluation of GA and GG allele could offer different personalized therapeutic targets. Testa R, Bonfigli AR, Sirolla C, et al. Effect of 4G/5G PAI-1 polymorphism on the response of PAI-1 activity to vitamin E supplementation in Type 2 diabetic patients. Diabetes Nutr Metab 2004;17:217-21. biochimica clinica, 2012, vol. 36, n. 6 489 44° Congresso Nazionale SIBioC - Riassunti Poster P039 TORCHECK: UNO STRUMENTO PER LA VALUTAZIONE ESTERNA DI QUALITÀ DEI TEST PER LA DETERMINAZIONE DEGLI ANTICORPI ANTITORCH 2 1 1 1 G. Fuzzi , S. Giovannini , A. Renieri , M. Pierini , R. 1 1 3 3 Ndreu , A. Pilo , C. Prontera , D. Battaglia , S. 1 1 Masotti , G. Zucchelli 1 QualiMedLab & Istituto di Fisiologia Clinica CNR, Pisa Laboratorio Analisi Istituto Fanfani, Firenze 3 Fondazione Toscana "Gabriele Monasterio", Pisa 2 I saggi anticorpali, nonostante alcuni interventi di standardizzazione e lo sviluppo di metodi automatizzati, continuano a essere affetti da variabilità molto elevate; questo è particolarmente evidente nelle determinazioni del complesso ToRCH. Per migliorare la comprensione delle problematiche legate alla misura di anticorpi e per fornire ai laboratori uno strumento di controllo, QualiMedLab/CNR propone da tre anni il programma “ToRCHeck” per la Valutazione Esterna di Qualità (VEQ) delle determinazioni quantitative e qualitative degli anticorpi IgG e IgM di Toxoplasma, Rubella, Citomegalovirus, Herpes simplex; la stessa VEQ consente di monitorare anche le determinazioni degli anticorpi IgG anti-Helicobacter pylori. Al ciclo di controllo 2012 partecipano circa 65 laboratori italiani. Per gli anticorpi anti-Rubella e anti-Toxoplasma la VEQ fornisce la possibilità di comparare i numerosi sistemi analitici che utilizzano metodi quantitativi per esprimere il titolo IgG dei sieri in UI/mL. Per questi anticorpi, i risultati del ciclo 2011 indicano che la variabilità totale (CV trametodi e tra-laboratori) è elevata (valore medio 33.8% per Toxoplasma IgG e 29.6% per Rubella IgG). Questa variabilità include sia la precisione dei metodi (che risulta compresa sia per Toxoplasma che per Rubella tra 15 e 25 CV%) sia le differenze sistematiche tra-metodi. La valutazione qualitativa dei risultati (basata sulle risposte dei partecipanti ai quali viene richiesto di classificare il campione come “positivo”, “negativo” o “dubbio”) mostra che in alcuni casi, in particolare nei campioni di controllo a concentrazione di anticorpi borderline, le classificazioni non sono univoche, talvolta anche nell’ambito dell’utilizzo dello stesso metodo. Queste misclassificazioni non sono da sottovalutare se si pensa che alcuni di questi test hanno particolare rilevanza nel monitoraggio sierologico delle donne in gravidanza e che il loro stile di vita potrebbe essere radicalmente modificato a seconda del risultato ottenuto. Il soggetto sieropositivo per Toxoplasmosi IgG e/ o per Rubella IgG è infatti ritenuto teoricamente “protetto”, mentre i soggetti non protetti devono sottoporsi a controlli periodici durante la gravidanza. P040 UN NUOVO APPROCCIO ALLA VALUTAZIONE DELLA COMMUTABILITÀ DI SIERI DI CONTROLLO PER L’ANALISI ENZIMATICA: L’ESEMPIO DELLA GAMMA-GLUTAMIL TRANSFERASI (GGT) A. Carobene, E. Guerra, F. Ceriotti Diagnostica e Ricerca San Raffaele, Istituto Scientifico Ospedale San Raffaele, Milano Dimostrare la commutabilità dei sieri di controllo utilizzati nei programmi di VEQ è uno dei problemi maggiori per la complessità del protocollo. Scopo di questo lavoro è validare un approccio alternativo alla verifica della commutabilità: confrontare gli effetti prodotti sui materiali di controllo con quelli sui pool di sieri umani freschi di analoga attività, modificando le condizioni di misura. Materiali e metodi: Partendo dal metodo di riferimento IFCC per la GGT abbiamo variato di volta in volta una condizione analitica: pH (da 7.5 a 8.5 a 25 °C); concentrazione e tipo di tampone (da glicilglicina (Gly-Gly)150 mmol/L a Tris + Gly-Gly 80 mmol/L), concentrazione del substrato (da 4 a 6 mmol/L). Le condizioni simulavano quelle presenti nei reattivi delle ditte Roche (Cobas 501), IL (ILab 650) e Siemens (Advia 2400). Nuovo approccio: 2 controlli e 2 pool analizzati in triplo per ciascuna condizione di reazione indicata. Modo tradizionale: 10 pool distribuiti su tutto il range analitico analizzati in doppio e controlli in triplo sia con metodo di riferimento sia con i reattivi delle 3 ditte. Risultati: La prova di commutabilità tradizionale indicava i 2 controlli commutabili per i metodi IL e Siemens, e non commutabile quello ad attività maggiore per il metodo Roche (scarto normalizzato = 6.6). Tutte le condizioni studiate mostravano comportamenti dei controlli lievemente diversi da quelli dei pool: l’incremento di 0.2 unità di pH rispetto all’ottimale comportava una riduzione di attività del 3% nei pool contro un aumento dell’1% nei controlli; la concentrazione di substrato di 4 mmol/L un decremento del 5.8% nei pool contro 8.8–9.5% nei controlli, il tampone Tris- Gly-Gly 80 + 80 mmol/L un decremento di 6.5% nei pool contro 4.5–5.5% nei controlli. Discussione: L’approccio proposto ha messo in evidenza un comportamento non commutabile per entrambi i materiali (effetto delle variabili diverso rispetto ai pool di sieri umani). L’apparente contraddizione con la prova tradizionale, che sembra invece confermarne la commutabilità, deriva da un duplice fattore: alcune condizioni hanno un effetto opposto e quindi si annullano (ad es. pH e concentrazione di substrato) e i metodi di routine da noi considerati lavorano in condizioni molto simili a quelle del metodo di riferimento. biochimica clinica, 2012, vol. 36, n. 6 491 44° Congresso Nazionale SIBioC - Riassunti Poster P041 VALUTAZIONE DELL’EFFICACIA DI INDICATORI BASATI SUL CQA PER IL CONTROLLO DELLA FASE ANALITICA P042 VALUTAZIONE ESTERNA DI QUALITÀ DELL'OSTEOCALCINA: DATI PRELIMINARI 1 R. Guerranti, M. Trinchera, A. Silvietti, C. Scapellato UOC Patologia Clinica – Azienda Ospedaliera Universitaria Senese, Policlinico Santa Maria alle Scotte, Siena – Italy Obiettivo: La definizione dei traguardi analitici rappresenta uno step fondamentale durante la pianificazione del controllo di qualità e l’Errore Totale accettabile (ETa) rappresenta una modalità per definire le specifiche di qualità di una misura. Conoscendo inoltre l’Errore Totale sperimentale (ETs) è possibile verificare il raggiungimento del livello di qualità progettato (ISO 15189). A tale scopo vi sono vari indicatori sui quali manca però una vera e propria standardizzazione. L’obiettivo di questo studio è la valutazione della concordanza dei risultati ottenuti con indicatori diversi da utilizzare per il controllo della fase analitica. Metodologia: Sono stati analizzati i dati del Controllo di Qualità Allargato (CQA) Liquid Assayed Multiqual (BioRad) escludendo gli analiti con un numero di laboratori partecipanti al CQA <10. Gli indicatori utilizzati sono il TEB % (ETs*100/ETa) ed il Sigma per i quali abbiamo scelto rispettivamente i valori <100 e >2 come valori soglia per stabilire il raggiungimento dell’ obiettivo. Per ogni analita abbiamo valutato la media per il TEB e per il Sigma su 6 serie di dati raccolti nel 2011 (2 livelli di controllo su 3 strumenti Cobas 6000, Roche). Risultati: I risultati ottenuti con i due indicatori derivati dal CQA sono stati anche confrontati con i dati delle VEQ 2011 della Regione Toscana. Questo studio evidenzia una concordanza del 93% fra i risultati degli indicatori TEB e Sigma (VPP 0,913 – VPN 1). Se poi confrontiamo il TEB ottenuto con l’ETs del CQA con il TEB ottenuto con l’ETs delle VEQ (entrambi rispetto rispetto ai traguardi fissati dal Laboratorio) otteniamo una concordanza del 92% (VPP 0,905 – VPN 1). Conclusioni: I valori del TEB ricavati dal CQA o dalla VEQ rappresentano entrambi dei validi indicatori per il monitoraggio del rispetto dei traguardi analitici. Analizzando altri indicatori ricavati dalla VEQ (% esercizi accettati rispetto agli esercizi inviati, zone) si ottengono percentuali di concordanza meno significative probabilmente per il fatto che le modalità con cui tali indicatori sono ricavati o il loro stesso significato (le zone VEQ valutano il miglioramento conseguibile) sono diversi fra CQA e la VEQ. Ottomano C, Ceriotti F, Galeazzi M, et al. Linee guida per la gestione dei programmi di Controllo di Qualità Interno. Biochim Clin 2008;32:102-21. 492 biochimica clinica, 2012, vol. 36, n. 6 1 1 1 S. Giovannini , A. Pilo , A. Renieri , M. Pierini , C. 2 2 2 2 Vassalle , S. Bianchi , A. Vannucci , D. Battaglia , G. 1 Zucchelli 1 QualiMedLab & Istituto di Fisiologia Clinica CNR, Pisa Fondazione Toscana "Gabriele Monasterio", Pisa 2 L'osteocalcina è una proteina di piccole dimensioni con funzioni endocrine sintetizzata principalmente dagli osteoblasti. Viene utilizzata per la valutazione del metabolismo osseo, ovvero in caso di osteoporosi, ma anche di iperparatiroidismo primario/secondario e morbo di Paget, che ne provocano aumenti anche elevati. Per valutare i metodi utilizzati e la qualità analitica nella misura dell'osteocalcina, a partire dal 2012 QualiMedLab/ CNR ha organizzato il programma sperimentale di Valutazione Esterna di Qualità (VEQ) Immunocheck Osteocalcina. Partecipano al programma 40 laboratori italiani e francesi. Ogni laboratorio riceve 12 campioni di plasma da misurare e trasmettere a QualiMedLab/ CNR tramite accesso riservato al sito web eqas.ifc.cnr.it o via fax. Al termine dell'esercizio, vengono preparati e diffusi riepiloghi esplicativi delle prestazioni del laboratorio che riportano il risultato ottenuto, la sua deviazione dalla media di consenso e dalla media del metodo, le statistiche di tutti i risultati e dei risultati raggruppati per metodo e la valutazione (valore Z e punteggio) del risultato. Ad oggi sono disponibili i risultati preliminari relativi ai dati inviati dai laboratori nei quattro esercizi di controllo conclusi. I metodi più usati nella VEQ sono: Diasorin Liaison (LSN), Roche Elecsys (ROCX), Siemens Immulite (IMM2), Brahms Kryptor (KRY). Dato che gli 8 campioni di plasma derivano da 3 pool OS1, OS2 e OS3 (inviati come campioni incogniti rispettivamente 3, 2 e 3 volte ciascuno), nel calcolo delle medie e dei CV% i risultati sono stati accorpati. Nel pool OS1 i metodi LSN, ROCX e KRY misurano da 28 a 32 ng/mL; nel pool OS2 gli stessi metodi misurano da 75 a 110 ng/mL; nel pool OS3 misurano da 146 a 191 ng/mL. L’accordo tra metodi risulta soddisfacente. Fa eccezione il metodo IMM2 che ottiene risultati molto più bassi (circa 50%) rispetto a LSN, ROCX e KRY (rispettivamente 11, 31 e 74 ng/ mL sui tre pool OS1, OS2, OS3). Queste differenze sono verosimilmente dovute ai diversi anticorpi utilizzati nella misura di questa proteina. Per quanto riguarda la precisione dei metodi (variabilità entro-metodo, tralaboratori) questa è da considerarsi buona (6-9 CV%), considerando anche che la molecola dell’osteocalcina è molto instabile. 44° Congresso Nazionale SIBioC - Riassunti Poster P047 BN2 E VISTA : DUE SISTEMI NEFELOMETRICI A CONFRONTO NELLA MISURA DI 17 COMPONENTI DEL SIERO E 4 DELLE URINE P048 CATENE LEGGERE LIBERE SIERICHE: ASPETTI ANALITICI E CONFRONTO FRA METODI 1 L. Loiodice, R. Lovero, E. Mascolo, M. Tampoia, L. Varraso, S. Calvi, A. Colacicco, R. Scarcella, I. Specchia, F. Di Serio U.O.Patologia Clinica I, Azienda Universitario Ospedaliera Policlinico di Bari Introduzione: Nel nostro laboratorio l’immissione di un nuovo analizzatore (VISTA Siemens) ha significato l’ apporto di una nuova tecnologia rispetto al sistema in uso (BN2 Siemens). Scopo del nostro lavoro è stato verificare il grado di correlazione dei due sistemi prima di iniziare la nuova attività lavorativa. Materiali e metodi: Abbiamo dosato 17 analiti sierici (IgG, IgA, IgM, IgE, C3, C4, A1AG, APT, Ceruloplasmina, RF, ASL, IgG1, 2, 3, 4, B2MS, HCY e 4 urinari (AlbU, B2M U, kappa U, lambda U) sui campioni pervenuti in routine per venti giorni. Per ogni analita sono stati calcolati il coefficiente di correlazione ( r ) di Pearson, lo slope ( S ) e l’intercetta ( I ) secondo la regressione lineare di Passing Bablock ed il p value secondo il test t di Student per dati appaiati. I risultati stati valutati anche con il metodo di Bland Altmann utilizzando il programma di statistica Medcal. I calibratori e controlli sono stati forniti dalla ditta Siemens per i rispettivi analizzatori. Risultati: L’r di Pearson è risultato compreso tra 0.85 e 0.99; lo slope varia tra 0,62 e 1,17 (i valori della pendenza comprendono il valore uno e non sono elevati) e l’intercetta ( I ) varia da –8 a +2 (i valori dell’I comprendono lo zero); il p value (>0,05) non ha rilevato differenze statisticamente significative per tutti gli analiti; secondo Bland ed Altmann il bias, con Intervallo di Confidenza al 95% da –13,21 a 27,42, conferma che le differenze (media + o - 1,96) non sono statisticamente significative e che, pertanto, i metodi possono essere usati in modo interscambiabile. Discussione e conclusioni: la comparazione tra i metodi valutata statisticamente e clinicamente, con il monitoraggio dei pazienti (check in), ha permesso l’interscambiabilità delle strumentazioni sino alla sostituzione del BN2 con il Vista, riducendo ogni possibilità di errore e migliorando le performance analitiche. 1 1 V. Barchiesi , D. Cerasuolo , M. Cuomo , E. 1 1 1 3 Leonardi , S. Liotti , R. Scarano , M. Di Donato , M. 3 2 1 Fumi , T. Lupo , E. Cavalcanti 1 S. C. Medicina di Laboratorio, I.N.T. - IRCCS, Fondazione G. Pascale, Napoli 2 DAsMeLab, Università Federico II, Napoli 3 Scuola di Specializzazione in Biochimica Clinica, Università Federico II, Napoli Per la diagnosi ed il monitoraggio dei pazienti con Componenti Monoclonali è entrata nella pratica clinica la misura delle Catene Leggere Libere sieriche (FLC) con metodi immunochimici. Per tale dosaggio, fino al 2011, era disponibile un kit commerciale che utilizza anticorpi policlonali, applicabile su diversi nefelometri e turbidimetri (Freelite™, The Binding Site); oggi è disponibile anche un metodo che utilizza anticorpi monoclonali (N Latex FLC, Siemens) applicabile sui nefelometri della stessa ditta. Scopo del lavoro è stato quello di valutare le performances analitiche dei due kit del commercio, confrontandoli tra loro secondo il protocollo CLSI. L’imprecisione tra le serie del kit Freelite™, applicato su Cobas C6000, Roche, ha mostrato su sieri di controllo, a due diversi livelli, dei CV inferiori a 4.5% per le catene κ ed a 5.5% per le catene λ. Per il kit N Latex FLC, applicato su BNP ProSpec, i CV erano inferiori al 5% per entrambe le catene leggere. L’imprecisione nella serie, valutata su pool di sieri a diverse concentrazioni, sia sul BNP ProSpec che sul Cobas C6000, ha mostrato CV sempre inferiori al 2% per entrambe le catene leggere. Sono stati valutati gli intervalli di riferimento, per il kit N Latex FLC, su 60 campioni da donatori afferenti alla Medicina Trasfusionale dell’INT, che sono sovrapponibili a quelli indicati dalla ditta produttrice. Per il confronto fra metodi sono stati analizzati 108 campioni da paziente, con gammopatie monoclonali, afferenti all’INT. Il t-test ha rivelato differenze statisticamente significative tra i due metodi per le catene κ (p=0.01) e rapporto κ/λ (p=0.02) e non significative per le catene λ(p=0.69). L’analisi della regressione lineare ha mostrato valori di r=0.89 per catene κ, r=0.60 per λ e r=0.78 per il rapporto. Il metodo di Cohen ha evidenziato un accordo tra i due metodi dell’89% per le catene κ, del 65% per le λ e dell’84% per il rapporto κ/λ. Il confronto fra metodi ha confermato che i due test non possono essere considerati equivalenti e che risultati migliori si ottengono quando il confronto viene effettuato utilizzando i due kit sulla stessa strumentazione. Si è inoltre evidenziata la mancata identificazione, con il kit N Latex FLC, di un caso di mieloma micromolecolare lambda. biochimica clinica, 2012, vol. 36, n. 6 495 44° Congresso Nazionale SIBioC - Riassunti Poster P049 CELIAC DISEASE DIAGNOSIS AND MONITORING: COMPARISON BETWEEN CHEMILUMINESCENCE AND ELISA ANTI-TRANSGLUTAMINASE AND ANTIDEAMIDATED GLIADIN PEPTIDES MEASUREMENTS 1 1 2 2 A. Aita , D. Basso , E. Rossi , M. Pelloso , G. 3 2 1 2 Guariso , C. Zambon , F. Navaglia , E. Greco , D. 2 2 1 2 Bozzato , A. Padoan , P. Fogar , M. Plebani P050 CHLAMYDOPHILA PNEUMONIAE: VALUTAZIONE DI UN NUOVO TEST DIAGNOSTICO IN IMMUNOENZIMATICA COMPLETAMENTE AUTOMATIZZATO F. Dastoli, M.M. Pietracupa, G. Solito, I. Ronchi, M. De Cristofaro U.O.C. Microbiologia e Virologia, Osp. S. Pertini, Roma ASL RMB 1 Department of Laboratory Medicine, University-Hospital of Padova, Italy 2 Department of Medicine - DIMED, University of Padova, Italy 3 Department of Women’s and Children’s Health, University of Padova, Italy Objectives: Celiac disease (CD) diagnosis is based on anti-tissue transglutaminase (tTG) and anti-deamidated gliadin peptides (AGA) determination. The majority of commercially available assays for tTG and AGA are ELISAs with sensitivity and specificity above 95%, never reaching however 100%. The aim of this study was to compare the analytical performances and the clinical utility for CD diagnosis and monitoring of tTG and AGA of the IgA and IgG classes measured by new chemiluminescent (QUANTA Flash®, Inova) and established ELISA (QUANTA Lite®, Inova) methods. The one run measurements of IgA and IgG tTG and AGA (h-tTG/DGP screen) by QUANTA Flash® and QUANTA Lite® were also evaluated. Methods: We studied 321 children (155 CD; 166 controls). tTG IgA and IgG, DGP IgA and IgG, h-tTG/DGP screen were measured by QUANTA Flash® and QUANTA Lite®. Results: Intra- and inter-assay coefficients of variations of QUANTA Flash® were: 1.6% and 3.0% for tTG IgA, 3.7% and 4.0% for tTG IgG, 8.6% and 6.8% for DGP IgA, 8.6% and 3.2% for DGP IgG, 5.1% and 2.4% for htTG/DGP screen. The most sensitive (96.1%) and specific (97.0%) test for CD diagnosis was QUANTA Flash® tTG IgA (cut-off:16 U), while the less sensitive (82.1%) and specific (78.6%) was QUANTA Lite® tTG IgG (cut-off:4 U). We performed binary logistic regression analyses considering CD diagnosis as dependent, and including as predictors QUANTA Flash® or QUANTA Lite® tTG IgA and IgG, DGP IgA and IgG, and h-tTG/DGP screen. QUANTA Flash® allowed to obtain a better correct overall classification of patients (96.60%) with respect to QUANTA Lite® (95.14%). Among QUANTA Flash® predictors, tTG IgA only was selected as significantly correlated with CD (r=0.263, p<0.0001, Exp(B)=1.0506, 95% CI=1,0286-1,0731). 18 CD children on GFD had a complete follow-up with measurements at 4, 12 and 24 months. QUANTA Flash® tTG IgA was the most reliable index (Repeated measures analysis of variance, between subject effect F=5.03, p<0.05) in monitoring GFD. Conclusion: QUANTA Flash® tTG IgA measurement is an extremely sensitive and specific index not only for CD diagnosis, but also for the monitoring of CD patient on GFD. 496 biochimica clinica, 2012, vol. 36, n. 6 Introduzione: Chlamydophila pneumoniae è uno dei maggiori agenti responsabili di infezioni respiratorie. Reinfezioni ad andamento cronico sembrano essere correlate anche con numerose patologie come aterosclerosi, morbo di Alzheimer, tumori polmonari; l’utilizzo di una sierodiagnosi è attualmente un sistema semplice, veloce e affidabile anche nella identificazione dello stato dell’infezione e nell’eventuale follow up del paziente. Materiali e metodi: Un totale di 58 sieri di soggetti con sintomatologia clinica di infezione respiratoria è stato analizzato per la ricerca di anticorpi IgA, IgG, IgM anti- C. pneumoniae per mezzo di un test ELISA in automazione (Chorus-Chlamydophila pneumoniae, Diesse). Come test di riferimento è stato utilizzato il kit già in uso presso il laboratorio (Cp Savyon Diagnostics Ltd); i risultati discordanti in IgM sono stati confermati mediante test di immunofluorescenza (Chlamydia MIF IgM, Focus Diagnostics). Risultati: La concordanza totale tra i due test in analisi è stata del 91.4% (CI95%=81.3-96.2) nel caso delle IgA (28 sieri positivi e 30 negativi) , 87.9% (CI95%=77-94) nel caso delle IgG (29 sieri positivi e 29 negativi) e del 93.1% (CI95%=83.5-97.3) per le IgM (7 sieri positivi e 51 negativi); la verifica dei campioni IgM discordanti dopo l’analisi con test in immunofluorescenza aumentava la concordanza totale al 94.8% (CI95%=85.9-98.1). Conclusioni: Lo studio effettuato conferma una buona correlazione dei test Chorus Diesse rispetto ai test utilizzati come riferimento interno, associata a caratteristiche di semplificazione nell’ esecuzione del test, con interventi dell’operatore e tempi di esecuzione e risposta ridotti al minimo. Campbell LA, Kuo CC, Wang SP, et al. Serological response to chlamydia pneumoniae infection. J Clin Microbiol 1990;28:1261-4. 44° Congresso Nazionale SIBioC - Riassunti Poster P051 COMPARISON OF TWO DIFFERENT PLATFORMS OF MOLECULAR DIAGNOSTICS A. Pancrazzi, T. Fanelli, C. Paoli, A. Spolverini, A.M. Vannucchi Dip. di Area Critica Med. Chir., Unità di Ematologia, Università di Firenze The high-resolution melt (HRM) is a technique that has many applications such as detection of mutations, genotyping of single nucleotide polymorphism, searchig for loss of heterozygosity, analysis of DNA methylation, characterization of the haplotypes. The widespread use of many types of analysis tools, based on different physical and chemical principles, contributes to the instrumental variability of diagnostic tests. We have compared 2 different instruments, one is Rotorgene 6000 (Corbett) and other is Step One Plus (Applied Biosystems, AB). The Corbett ‘s instrument works with the technology of ventilated rotor while AB works with the Peltier system. We evaluated the ability of each instrument to genotype by melting temperature (Tm) and to scan for heterozygosity by curve shape. A 107bp fragment of the MPL was amplified by PCR and 3 different amplicons of genotypes MPL515WT, MPL515WL and MPL515WK were analyzed. These MPL mutations, that result in the substitution of tryptophan 515 with leucine (W515L) or lysine (W515K), have been identified in 5-10% of patients with primary myelofibrosis and 3% with essential thrombocythemia (Vannucchi et al, Blood, 2008). The sample used for the qualitative analysis is genomic DNA from 10 donors and from 2 patients positive for mutations MPL515. The gDNA was subjected to total amplification (WGAkit, Qiagen). Were prepared dilution curves with DNA from healthy donors and patients (analyzed in Sanger system). The curve points for the analysis of the mutation MPL515WL were the following: 1%, 10%, 50%, 100% and for MPL515WK: 1%, 10%, 50%. The use of different platforms and reagents required an optimization. Reagents of the instruments manufacturers have best performance in their respective machine. By setting a standard reading range (70-95°C), the delta of average melting temperatures between the MPL515WL PCR curve analyzed in AB and the one analyzed in Corbett is 4.90, for MPL515WK PCR curve the delta is 4.05. This difference on raw data value is extremly significant (p <0.0001). This work shows that the diffusion of various technologies require a careful analysis of optimization and a particular attention to the type of data released for clinical diagnostics. P052 CONFRONTO TRA DUE METODICHE PER IL DOSAGGIO DELL’ ANTIGENE PROSTATICO SPECIFICO TOTALE G. Barbina, U. Qualizza, A. Colatutto, B. Marcon, E. Tonutti, S. Mazzolini, P. Sala Dip. di Diagnostica di Laboratorio, Azienda OspedalieroUniversitaria “S. Maria della Misericordia”, Udine Scopo: L’antigene prostatico specifico (PSA totale) è una molecola appartenente al gruppo delle callicreine (idrolasi), sintetizzato dalla ghiandola prostatica che, dosato nel sangue si è dimostrato un utile marcatore, sensibile e specifico, nel monitoraggio post operatorio di pazienti con cancro prostatico oltre che nel monitoraggio dell’ipertrofia prostatica benigna. Scopo del presente lavoro è il confronto tra due metodiche interamente automatizzate tra le più in uso. Materiali e metodi: Sono stati raccolti e sottoposti ad analisi settanta campioni di siero. Tali campioni sono stati dosati in duplicato con la metodica PSA ADVIA Centaur (Siemens Healthcare Diagnostics) e con quella PSA Third Generation Immulite 2000 (Siemens Healthcare Diagnostics). Risultati: Una prima analisi dei dati mostra un intervallo di concentrazione che va da 0.01 a 9.50 μg/L per la metodica ADVIA Centaur e da 0.01 a 12.5 μg/L per la metodica IMMULITE 2000. La correlazione risulta ottima (R= 0.9908) con lieve sovrastima della metodica ADVIA Centaur (y = 1.1244x – 0.0488). La precisione analitica totale evidenzia un CV di 6.41% per ADVIA Centaur e si attesta su 8.2% per IMMULITE. Discussione e conclusioni: La comparazione delle due metodiche nell’intervallo considerato risulta molto buona sia in termini statistici che clinici. I bassi CV riscontrati indicano che i prodotti offrono ampia garanzia di efficacia analitica. La nostra esperienza ci suggerisce che una scelta tra le due metodiche, considerata l’elevata qualità dei risultati che ambedue hanno dimostrato, andrebbe fatta principalmente sulla base del modello organizzativo che ciascun laboratorio intende adottare. Watt KW, Lee PJ, M'Timkulu T, et al. Human prostatespecific antigen: structural and functional similarity with serine proteases. Proc Nat Acad Sci USA 1986;83:3166-70. biochimica clinica, 2012, vol. 36, n. 6 497 44° Congresso Nazionale SIBioC - Riassunti Poster P054 DETERMINAZIONE DEI SOLFATI ED OSSALATI URINARI: ULTERIORI ACCORGIMENTI METODOLOGICI P053 CONFRONTO TRA IL DOSAGGIO DELLA TROPONINA T CON METODICA DI 4^ GENERAZIONE E CON METODICA AD ALTA SENSIBILITÀ 1 2 1 1 B. Rampoldi , R. Rigolini , P. Giubbilini , E. Perfetti , S. 1 2 1 Mazza , S. Palatresi , E. Costa G. Cangiano , A. Latte , E. Di Maina , G. Buccino , C. 1 1 1 Taranto , A. Garofalo , M.M. D'Ambrosio , M. 1 1 D'Amora , A. Sarappa 1 Servizio di Medicina di Laboratorio, IRCCS Policlinico San Donato, San Donato Milanese 2 Unità Operativa di Cardiologia Clinica - UTIC, IRCCS Policlinico San Donato, San Donato Milanese 1 Introduzione: L’infarto del miocardio acuto costituisce la principale causa di morte. Negli ultimi decenni la possibilità di dosare le troponine cardiache specifiche (cTn) ha cambiato l’approccio alla diagnosi di sindrome coronarica acuta. In particolare le nuove tecnologie hanno consentito di sviluppare saggi immunologici ad alta sensibilità in grado di rilevare nel siero e nel plasma concentrazioni molto basse di troponina T (cTnT). Scopo: Lo scopo di questo studio è quello confrontare i dosaggi di cTnT effettuati con il test di 4^ generazione e con il saggio ad alta sensibilità. Materiali e metodi: Sono stati arruolati 274 soggetti sani e 77 pazienti ricoverati nel reparto di cardiologia con sindrome coronarica acuta. A questi è stato effettuato il dosaggio della cTnT sia mediante il test troponina T di 4^ generazione sia mediante il test troponina T hs (Roche Diagnostics Cobas e 601). Risultati: L’analisi dei dosaggi effettuati sui campioni di soggetti sani con le due metodiche ha mostrato differenze statisticamente significative (media±errore standard) (12,47 ng/L ± 1,556 per TnT vs 6,029 ng/ L ± 0,4173 per TnT hs; p<0,0001) mentre l’analisi dei dosaggi effettuati sui campioni di soggetti malati non ha mostrato differenze statisticamente significative (837,2 ng/L ± 152,5 per TnT vs 822,2 ng/L ± 154,5 per TnT hs; p=0,2474). L’analisi della regressione lineare tra i risultati ottenuti con le due metodiche nei soggetti sani (intervallo 10-380 ng/L) mostra una slope di 0,1170 ± 0,01463 e Il dosaggio dell’ossaluria si effettua per lo studio nefrolitiasico ma anche su “opportuna” soluzione acquosa per la valutazione quali/quantitativa di un calcolo urinario. La relativa automazione di tale parametro assieme al “complicato” dosaggio fotometrico del solfato nelle urine indirizza il laboratorista a trovare nuovi accorgimenti metodologici e strumentali al fine di ottenere prestazioni affidabili, facilmente realizzabili ed a costo contenuto. Le metodiche a termine utilizzate su VIVA Vitalab Siemens hanno i seguenti parametri strumentali: solfati precipitati con bario cloruro (lettura a 436 nm, multipunto a 6 calibratori – 0-20-50-100-200 e 400 mg/dL, R1:urina = 220:5 μL), ed ossalati (lettura a 578 nm, a 2 calibratori – 0 e 0,5 mmol/L), R1:urina:R3 = 200:9:50 μL). La determinazione dell’ossalato nei calcoli urinari utilizza una soluz. acquosa ottenuta con circa 0,20 mg di calcolo frantumato / 5 gocce di acido solforico conc. / 5-10 mL con acqua e breve centrifugazione. I metodi risultano lineari fino a 400 mg/dL per i solfati e 3,00 mmol/L per gli ossalati. Si evidenziano profili di imprecisione inferiori al 5% negli intervalli 0,01 – 3,00 mmol/L per gli ossalati e 2 - 400 mg/dL per i solfati. Le prove di recupero mostrano per gli ossalati valori percentuali compresi tra l’81,8 ed il 102,7% (recupero medio del 96,1%) e per i solfati valori tra il 95,4 ed il 106,02% (recupero medio del 98,2%). Le imprecisione nella e tra le serie mostrano dei CV<4%. Buone sono le correlazioni ottenute tra i valori dosati con le metodiche adattate su VIVA Vitalab rispetto a quelli ottenuti con il metodo manuale per gli ossalati e con l’analizzatore AU600 Beckman per i solfati. Il kit in “manuale” Acido Ossalico della ditta LTA da noi adattato sullo strumento VIVA Vitalab consente di determinare agevolmente non solo l’ossalato nelle urine ma anche quello contenuto nei calcoli urinari. Con le variazioni metodologiche da noi apportate in automazione è possibile triplicare il numero delle determinazioni per confezione di acido ossalico. Il dosaggio dei solfati da noi creato ed automatizzato non necessita di bianco campione e si effettua subito dopo la calibrazione evitando così la degradazione del reagente preparato. Cangiano G, Russo M, Forte F, et al. Diagnostica di laboratorio della calcolosi urinaria. Biologi Italiani 2008;8:40-7. 1 1 1 1 2 un’intercetta di 4,570 ng/L ± 0.4181; r =0,1904. L’analisi della regressione lineare tra i risultati ottenuti con le due metodiche nei soggetti malati (intervallo 10-6850 ng/L) mostra una slope di 1,010 ± 0,009680 e un’intercetta di 2 -23,29 ng/L ± 15,21; r =0,9932. Conclusioni: I nostri dati dimostrano l’esistenza di una scarsa correlazione del test troponina T hs con il saggio di 4^ generazione nel range di valori della popolazione sana ed un’elevata correlazione nel range di valori della popolazione malata, a conferma della maggiore sensibilità del test troponina T hs. Thygesen, K, Alpert J, White HD on behalf of the Joint ESC/ACCF/AHA/WHF Task Force for the Redefinition of Myocardial Infarction. Eur Heart J 2007;28:2525-38. 498 biochimica clinica, 2012, vol. 36, n. 6 U.O. Lab. Patologia Clinica, Osp. dei Pellegrini, ASL NA 1 Centro 2 Lab. Patologia Clinica ed Ematologia, Azienda Ospedaliera apss Trento 44° Congresso Nazionale SIBioC - Riassunti Poster P055 DETERMINAZIONE DELL'OMOCISTEINA: DUE METODI IMMUNOLOGICI COMPETITIVI A CONFRONTO L. Zardo, S. Chiappin, R. Turrini, L. De Valentin, D. Bergamin, G. Piaserico P056 DETERMINAZIONE DELLA PROTEINA C REATTIVA: CONFRONTO FRA DUE METODI A. Romero, L. Battistelli, M. Mercadanti, A. Caleffi, G. Lippi Lab. Analisi, Ospedale di Castelfranco Veneto (TV) U.O. Diagnostica Ematochimica, Az. OspedalieroUniversitaria, Parma L'omocisteina (Hcy) è un aminoacido solforato che si forma dalla demetilazione intracellulare della metionina, aminoacido essenziale che viene introdotto con l'alimentazione. Recenti studi hanno evidenziato che concentrazioni plasmatiche elevate di Hcy sono correlate ad un aumento del rischio di malattia cardiovascolare, sono un fattore di rischio per patologia neurodegenerative, sono presenti nelle donne in gravidanza affette da preeclampsia, distacco prematuro di placenta e aborti spontanei e ricorrenti. Scopo di questo lavoro è confrontare due diversi metodi immunologici competitivi per la determinazione dell'Hcy totale che comprende sia le forme libere sia legate alle proteine: HemosIL Homocysteine applicato su ACL TOP 700 e Immulite 2000 Homocysteine. Sono stati analizzati 40 pazienti per ciascuno dei quali è stato raccolto un campione di plasma con Na fluoruro per la determinazione su Immulite e uno di plasma citrato per la determinazione su ACL TOP. E' noto che i valori di Hcy ottenuti con plasma citrato sono approssimativamente più bassi del 14,6% rispetto a quelli degli stessi campioni anticoagulati con EDTA o eparina a causa della diluizione con l'anticoagulante. Avendo assimilato la nostra provetta contenente Na floruro a quelle con EDTA o Eparina, i dati ottenuti su ACL TOP sono stati aumentati del 14,6% prima del confronto con quelli ottenuti su Immulite 2000. L'analisi dei dati mediante regressione lineare ha dimostrato una buona correlazione fra i due metodi (r= 0,9103) come pure il diagramma di Bland-Altman, dove solo 4 campioni su 36 risultano avere una differenza fra i due metodi che non rientra nell'intervallo di confidenza al 95%. Anche la valutazione della classificazione dei risultati in normali o patologici sulla base dei rispettivi intervalli di riferimento ha riportato una buona sovrapposizione fra i due metodi analizzati: solo due pazienti sono stati inquadrati, da un punto di vista clinico, in modo significativamente diverso dai due metodi. I due metodi si possono definire confrontabili. Le differenze significative riscontrate fra i due sistemi (5% dei pazienti studiati) sono probabilmente da attribuire a qualche interferente presente nel campione che agisce diversamente nei due metodi di analisi. Introduzione: La proteina C reattiva (PCR), sintetizzata dal fegato, sotto lo stimolo delle citochine proinfiammatorie, è il reattante della fase acuta più utilizzato nella diagnosi e nel monitoraggio delle flogosi acute e croniche. Lo scopo del nostro studio è quello di valutare la performance di una metodica applicabile su piattaforma di chimica clinica, in confronto con la metodica nefelometrica in uso, al fine di verificarne il possibile utilizzo in regime di urgenza. Materiali e metodi: I campioni di siero di 54 pazienti sono stati processati utilizzando la metodica nefelometrica di riferimento con strumento BN Prospec e reattivo PCR hs (Siemens), e con il metodo a intervallo esteso (RCRP) basato su una tecnica immunoturbidimetrica con particelle (PETIA), applicato su Dimension X Pand (Siemens). Il metodo nefelometrico con PCR hs ha una sensibilità analitica di 0.0015 mg/L, diluisce automaticamente il campione in caso di eccesso di antigene. L’intervallo di misura analitica del metodo RCRP comprende valori da 0.5 a 250 mg/L; i campioni con valori di PCR superiori a 250 mg/L devono essere diluiti manualmente. Risultati: L'equazione del modello per le statistiche di regressione (risultati del metodo RCRP) = pendenza x (risultati del sistema BN) + intercetta ha evidenziato una pendenza di 1.047, un'intercetta di 0.81 mg/L, e un coefficiente di correlazione di 0.9983. Discussione: Il dosaggio della PCR è ampiamente utilizzato nella valutazione degli stati infiammatori. La facilità di esecuzione del test e la applicabilità su piattaforme di chimica clinica automatizzate ne hanno consentito l’utilizzo anche in regime di urgenza. Dai risultati del nostro lavoro si evince che le performances dei due metodi sono sovrapponibili. Riteniamo che la minore sensibilità analitica del metodo RCRP per i valori estremi dell’intervallo analitico, sia compensata dalla più rapida velocità di esecuzione, considerando la previsione di utilizzo in regime di urgenza. La possibilità di applicare il metodo RCRP su analizzatore di chimica clinica, attualmente dedicato alla farmaco-tossicologia, consente di implementarne l’utilizzo e di sostituire il nefelometro dedicato all’urgenza, con un risparmio di risorse tecniche ed economiche. biochimica clinica, 2012, vol. 36, n. 6 499 44° Congresso Nazionale SIBioC - Riassunti Poster P057 DETERMINAZIONE DELLA TRANSFERRINA CARBOIDRATO CARENTE (CDT): PRESTAZIONI DEI METODI SEPARATIVI A CONFRONTO P058 DISTRIBUZIONE DEI VALORI DI TROPONINA T HS CARDIACA (CTNT HS) IN UNA POPOLAZIONE DI SOGGETTI SANI A. Fortunato, C. Marchetti, G. Soffiati B. Rampoldi , R. Rigolini , P. Giubbilini , E. Perfetti , S. 1 2 1 Mazza , A. Ricevuti , E. Costa Laboratorio di Chimica Clinica ed Ematologia - Ospedale "San Bortolo" Vicenza Introduzione: La transferrina, una glicoproteina (ß1globulina) coinvolta nel trasporto del ferro, le isoforme (disialo, monosialo e asialotransferrina) denominate nel loro complesso transferrina carboidrato carente (CDT) rappresentano complessivamente, nel siero di pazienti con un consumo regolare di alcol, meno del 2% della transferrina totale. C’è un generale consenso sulla correlazione tra consumo di alcol al di sopra di 60-80 g/ die per 10-15 giorni ed un aumento della CDT al di sopra del valore normale. Materiali e metodi: Sono state confrontate le determinazioni di CDT eseguite su 88 campioni di siero di pazienti afferenti al nostro Laboratorio per la verifica del consumo cronico di alcol con un metodo HPLC (BioRad % CDT su strumento Agilent 1200) e due metodi in EC di cui uno Capillarys (SEBIA) dotato di più capillari, in grado di processare fino ad 8 campioni contemporaneamente, adatto per processare un numero elevato di campioni ed uno P/ACE MDQ (Beckman-Coulter) con un singolo capillare ed adatto per essere utilizzato da personale specificamente addestrato. In questo studio non sono stati utilizzati metodi immunometrici in quanto non dimostrano una specificità analitica comparabile con quella dei metodi separativi. Risultati: In 78 campioni (89%) i risultati sono al di sotto del valore soglia per tutti i metodi. Gli altri 10 (11%) risultano tutti positivi con HPLC, con P/ACE 6 di questi risultano positivi e 4 vengono classificati come dubbi , con Capillarys i campioni positivi concordanti sono 6. Due dei quattro campioni risultati negativi con Capillarys e positivi con HPLC mostrano in CE % di CDT molto vicine al valore soglia. Discussione: In questo studio, anche se su un numero limitato di campioni, i metodi presi in considerazione hanno dimostrato una adeguata specificità (le discrepanze sono legate a campioni con valori molto vicini alla soglia), anche se con diversa sensibilità nell’identificazione di isoforme particolari (varianti genetiche) e con differenti caratteristiche di praticabilità e produttività. 500 biochimica clinica, 2012, vol. 36, n. 6 1 1 1 1 1 Servizio di Medicina di Laboratorio, IRCCS Policlinico San Donato, San Donato Milanese 2 Unità Operativa di Ortopedia II, IRCCS Policlinico San Donato, San Donato Milanese Introduzione: La troponina T viene attualmente considerata il più sensibile e specifico marcatore biochimico di necrosi del miocardio. La Società Europea di Cardiologia, l’American College of Cardiology (ESC/ACC) e l’American Heart Association (AHA) offrono una nuova definizione universale di infarto miocardico basata sul riscontro di danno miocardico in relazione ad un aumento delle concentrazioni ematiche di troponina T oltre il limite del 99° percentile della popolazione di riferimento in un contesto clinico di ischemia miocardica acuta. Scopo: Lo scopo di questo studio è quello di valutare la distribuzione dei valori di cTnT hs misurata mediante il test troponina T hs (Roche Diagnostics Cobas e601) in una popolazione di soggetti sani e caratterizzare la sua relazione al genere ed all’età. Materiali e metodi: È stata presa in considerazione una popolazione di 274 soggetti candidati ad intervento di chirurgia ortopedica (132 maschi e 142 femmine) con un’età media (SD) di 56,07 (17,77) anni [intervallo: 15-91]; femmine 60,41 (16,78) anni, maschi 51,41 (17,68). La presenza di patologie cardiache acute è stata esclusa mediante l’anamnesi ed un’accurata valutazione clinica. Risultati: Non si osservano differenze statisticamente significative tra i valori di cTnT hs (media ± SEM) in uomini e donne (uomini: 6,508 ng/L ± 0,6508, n=132; donne: 5,838 ng/L ± 0,5835 n=142; p=0,4431). I soggetti sono stati suddivisi in 8 gruppi di età crescente ed è stata effettuata un’analisi della varianza dalla quale emerge che esiste una differenza statisticamente significativa tra i diversi gruppi. In particolare si osserva un aumento del valore medio di cTnT nel gruppo: età > 81. Media ± errore standard degli 8 gruppi: 10-20: 3,222 ng/L ±0,2222; 21-30: 4,063 ng/L±0,6799; 31-40: 3,792 ng/ L±0,5212; 41-50: 4,078 ng/L±0,5040; 51-60: 5,905 ng/ L±1,447; 61-70: 6,310 ng/L±0,8903; 71-80: 8,491 ng/L ±1,136; >81: 13,46 ng/L±2,611; p<0,0001. Conclusioni. I nostri dati indicano che il valore di cut-off, basato sul 99° percentile della distribuzione della cTnT hs in una popolazione di soggetti sani, può cambiare significativamente in base all’età della popolazione di riferimento. 44° Congresso Nazionale SIBioC - Riassunti Poster P059 ELETTROFORESI CAPILLARE: VALUTAZIONE DI UN NUOVO STRUMENTO 1 1 2 3 P060 ELETTROFORESI IN TECNICA CAPILLARE E GEL D’AGAROSIO PER LA IDENTIFICAZIONE DELLE COMPONENTI MONOCLONALI DI PICCOLA ENTITÀ: NOSTRA ESPERIENZA A. Vernocchi , E. Longhi , M. Mussap , U. Basile 1 Servizio di Medicina di Lab., IRCCS Multimedica, Milano 2 Lab. Centrale IRCCS San Martino e Ist. Naz. ricerca sul cancro, Genova 3 Dip. di Medicina di Lab., Policlinico Gemelli, Roma E’ stato valutato presso il nostro Laboratorio il nuovo strumento V8-Elettroforesi Capillare (HelenaUK) commercializzato in Italia da Medical Systems, per la separazione delle proteine sieriche, secondo un dettagliato protocollo. Di seguito sono riportati in sintesi i punti più significativi. Imprecisione: lo studio dell’imprecisione nella serie e tra le serie è stata effettuata su 3 diversi campioni per albumina, alfa1, alfa2, beta1, beta2 e gamma globuline. Le prove “nella serie” e “fra le serie” sono state eseguite secondo le indicazioni di specifici e riconosciuti documenti. Essendo la ricerca delle Componenti Monoclonali (CM) lo scopo diagnostico principale della elettroforesi sierica, è stata valutata anche l’imprecisione nella serie di una CM (CV=1.5%). Sensibilità: la sensibilità è stata valutata su un campione con una CM di 15 g/L. Per effettuare le diluizioni della CM sono stati usati due campioni di siero, uno con ipogammaglobulinemia ed un secondo con normogammaglobulinemia. La sensibilità ottenuta è stata di 0.4 g/L (sensibilità desiderabile non oltre 0.7 g/ L). Confronto con Capillarys (Sebia), strumento utilizzato per la routine presso il nostro Laboratorio, con lo scopo di valutare la correlazione delle concentrazioni di 61 differenti campioni con CM selezionati in tre differenti 2 Laboratori: R =0.9875. Complessivamente sono stati eseguiti e confrontati tra i due sistemi dal 12 ottobre 2011 a tutt’oggi circa 2500 campioni. Interferenze analitiche: E’ stata valutata l’interferenza da emoglobina (campione con forte emolisi), da chilomicroni e da mezzi di contrasto (MdC). E’ stata testata l’intererenza dei seguenti MdC: MdC per coronarografia, MdC per TAC e gadolinio per RMN. Lo studio è stato effettuato sia “in vivo” sia “in vitro”. E’ stato inoltre valutato il carry over utilizzando un siero con elevata CM ed un siero con ipogammaglobulinemia, non evidenziando eventuale carry over causato dalla CM. La produttività dello strumento è di 40 campioni/ ora reali, quindi più ridotta rispetto a quella di Capillarys (Sebia), essendo il capillare dello strumento V8 di una lunghezza maggiore (23 cm), ma la capacità di risoluzione soprattutto nelle zone beta1 e beta2 è risultata decisamente migliore, proprio per la differente lunghezza del capillare. 1 1 1 M. Mosavat , A. Saccà , A. Andreozzi , G. 1 2 2 1 D’auria, , M.C. Stanziola , A. Castagliuolo , R. Iovine 1 ASL NA2 Nord, Laboratorio di Patologia Clinica, Ospedale San Giuliano, Giuliano in Campania 2 ASL NA2 Nord, Laboratorio di Patologia Clinica, Ospedale Rizzoli, Ischia Obiettivo dello studio è stato, quello, di comparare la elettroforesi sieroproteica, relativa ai campioni della routine di una settimana, del metodo capillare versus quella eseguita in agarosio per identificare e tipizzare CM di valore ponderale medio e piccolo. Due operatori esperti hanno ispezionato visivamente, in cieco, le due serie di analisi di 416 reperti ciascuna. Per dirimere dubbi o confermare le positività/negatività abbiamo utilizzato il metodo Immunofissativo (IFE Interlab). Come tempi operativi i due metodi hanno dimostrato una produttività comparabile. Per i tempi di refertazione, la ispezione visiva dei 416 grafici-capillare ha richiesto un tempo superiore di 27’ rispetto al tempo impiegato per la ispezione visiva delle ETF in agarosio. La concordanza tra operatori nella individuazione dei campioni allarmati o positivi è stata superiore per la tecnica in agarosio; 92% contro 86%. I campioni falsi positivi sono stati in numero superiore per l’agarosio (specificità diagnostica capillare 99.7% contro 98.5% agarosio). La sensibilità diagnostica del metodo in agarosio è stata del 93,8 % (15 positivi, per una prevalenza del 3.60%) contro il 65,2% del metodo capillare (7 positivi, per una prevalenza dello 1.68%). Riteniamo, infine, che tali differenze siano da imputare alla maggiore sensibilità del metodo in agarosio, ma anche ad una necessaria implementazione ed affinamento della ispezione visiva dei grafici della capillare. biochimica clinica, 2012, vol. 36, n. 6 501 44° Congresso Nazionale SIBioC - Riassunti Poster P061 ELETTROFORESI SU GEL D'AGAROSIO AD ALTA RISOLUZIONE A COSTI CONTENUTI 1 1 1 1 P. Sacchi , A. Recchioni , S. Lodolini , M. Bassano , S. 1 2 Cicconi , M. Acetoso 1 U.O. Medicina di Laboratorio, Osp. B.Eustachio, San Severino Marche, MC 2 U.O. Lab. Analisi, A.O. San Salvatore, Pesaro Scopo del lavoro: proporre una metodica modificata, al fine di ottenere una maggior risoluzione per la ricerca di componenti monoclonali sieriche ed aumentare il valore semeiotico dell'elettroforesi. Materiali e metodi: Strumento Interlab G26, kit per elettroforesi delle proteine del siero ß1 ß2 Interlab, coloranti Acid blue ed Acid Violet. Risultati: La metodica standard Interlab prevede una migrazione di 8 min. a 400V ed una colorazione con Acid blue per 4 min.; si ottiene un pattern elettroforetico di 22 mm con separazione delle sieroproteine in sei zone o bande distinte, ciascuna contenente una o più proteine differenti. Sono stati analizzati 155 campioni, provenienti da pazienti lungodegenti, oncologici ed in larga maggioranza ultrasessantacinquenni. Ispezionando visivamente i gel, difficilmente si percepivano quadri di oligoclonalità, frequenti per la tipologia dei pazienti studiati. Lo strumento Interlab G26 esegue in completa automazione ogni fase del processo analitico (cadenza analitica 117 test/h) e permette di applicare modifiche alla metodica; le migliori condizioni operative, a nostro avviso, prevedono una migrazione di 13 min. a 400V ed una colorazione con Acid Violet per 10 min. In tal modo, si ottiene un pattern elettroforetico di 35 mm. Analizzando nuovamente i campioni, sono risultate apprezzabili la banda della pre-albumina, l'eterozigosi dell'α1antitripsina, tra le zone ß1 e ß2 una tenue banda relativa alla frazione C4 del complemento, in zona anodica gamma una tenue banda relativa a FDP; in caso di manifesto quadro infiammatorio, in zona catodica gamma si è evidenziata una banda omogenea relativa alla PCR. La zona gamma è risultata ampiamente distesa ed in alcuni casi con evidenti quadri di oligoclonalità in relazione all'età ed alle patologie dei pazienti studiati. Le bande relative a C4, FDP, PCR, α1antitripsina sono state tipizzate mediante immunofissazione. Conclusioni: l'applicazione della metodica modificata non inficia in maniera significativa la produttività dello strumento ed utilizzando il kit della metodica standard non genera aumento dei costi. 502 biochimica clinica, 2012, vol. 36, n. 6 P062 ETANOLO: CONFRONTO FRA CONCENTRAZIONE PLASMATICA CON METODO ENZIMATICO E CONCENTRAZIONE EMATICA IN HS-GC-FID L. Gasbarri, S. Corezzi, S. Fabbroni, E. Luttini, F. Mencaroni, D. Tavanti U.O. Tossicologia, Lab. Anal. Osp. S.Donato, ASL8 Arezzo Nel nostro Laboratorio l’etanolo viene dosato H24 nel plasma con metodo di screening enzimatico. I campioni con valore legale positivi allo screening vengono successivamente sottoposti a conferma HS-GC con detector FID. In questo caso si utilizza sangue intero dalla seconda provetta di prelievo. Per l’etanolo, il Codice della Strada prevede infatti limiti di concentrazione nel sangue intero. Materiali e metodi: Il metodo di screening utilizza il reattivo EtOH Flex Reagent Cartridge Siemens su strumento Dimension RXL. L’etanolo è ossidato ad aldeide acetica in presenza di ADH con riduzione del NAD a NADH ed aumento di assorbanza a 340 nm. Il range analitico è 0.03-3.0 g/L. Il metodo HS-GC prevede la diluizione 1:6 del sangue intero con soluzione acquosa contenente iso-propanolo come S.I. e (NH4)2SO4 1M come agente di salting-out. L’analisi è effettuata su GC Perkin Elmer Clarus 580 dotato di iniettore in spazio di testa TurboMatrix 40 e detector FID (200 °C) gestito dal programma TotalChrom Navigator. Il campione viene termostatato per 15’ a 70 °C sotto agitazione ed analizzato in isoterma a 40 °C su colonna Perkin Elmer Elite-BAC1 (30 m, 0.32 mm ID, 1.8 μm df) con flusso di He 2.0 mL/ min. I tr sono 2.58 min per l’etanolo e 3.91 min per lo S.I.. Il range di calibrazione è fino a 6.0 g/L. Risultati: Delle 2 metodiche si è valutata precisione fra le serie ed accuratezza. 50 campioni sono stati analizzati con le 2 metodiche ed i valori di concentrazione sono stati correlati utilizzando la regressione lineare con metodo dei minimi quadrati (pendenza=0.872, intercetta=-0.058, R=0.9914) e metodo di Passing e Bablok (pendenza=0.855, intercetta=-0.040). I valori nel sangue intero risultano circa il 15% in meno rispetto a quelli nel plasma in accordo con il diverso contenuto di acqua nelle due matrici. Emerge pertanto la necessità che l’utenza sanitaria e l’Autorità Giudiziaria siano informati della sovrastima del valore preliminare ottenuto nello screening rispetto a quello definitivo ottenuto con la conferma cromatografica. Barnhill MT Jr, Herbert D, Wells DJ Jr. Comparison of hospital laboratory serum alcohol levels obtained by an enzymatic method with blood levels forensically determined by gas-chromatography. J An Tox 2007;31:23-30. 44° Congresso Nazionale SIBioC - Riassunti Poster P063 EVALUATION OF DIRUI ANALYZERS FOR URINE CHEMISTRY AND URINE SEDIMENT ANALYSIS 1 1 2 2 D. Pesce , G. Cirillo , C. Gasparinetti , S. Michienzi P064 EVALUATION OF SYSMEX XE-5000 FOR FLOW CYTOMETRIC ANALYSIS OF PERITONEAL FLUID G. Lippi, C. Cattabiani, D. Gennari, F. Pavesi, M. Bardi, P. Bonelli, S. Pipitone 1 Lab. di Analisi Cliniche e Microbiologiche, Osp. Santa Scolastica, Cassino 2 Servizi Diagnostici S.r.l., Roma The aim of this study was to evaluate the urine analyzers DIRUI H-800/FUS-100 for chemical and sediment analysis, respect to systems of other brands, in terms of reliability and analytical quality. Linearity, precision and carryover were determined for both instruments. A total of 550 urine samples was analyzed and the results was compared in term of agreement/disagreement and additional tests (clinical chemistry assay and manual microscopic count) were carried out to validate the result. For glucose, bilirubin, urobilinogen, blood, ketone and nitrite results the percentage of agreement was greater than 90%, less for leukocyte esterase and protein results (79,1% and 74,4%, respectively). Analysis of discordant results showed for H-800 a good correlation with clinical chemistry analisys for bilirubin and low correspondence for glucose and proteins. No supplementary tests were available for urobilinogen and ketones. Results in disagreement for blood, nitrite and leukocyte were confirmed by manual microscope review: it showed for H-800 a 37% of agreement for blood results, 80% for nitrite and 57% for leukocytes. Urine samples with abnormal or high abnormal microalbumin/creatinine ratio (M:C) by H-800 were tested with an immunoturbidimetric assay that confirmed the 100% of samples with normal M:C and 43% with abnormal and high abnormal M:C. RBCs, WBCs, squamous and not squamous epithelial cells, pathological casts, hyaline casts and yeasts showed results with high percentage of agreement on the systems. Only crystals and bacteria data showed results with substantial disagreement. Review of the manual count on disagreement samples showed that the FUS-100 was correct on 71% of samples for RBCs, 79% for WBCs, 85% for SECs, 88% for NSECs, 22% for pathological casts, 78% for hyaline casts, 79% for yeast, 88% for crystals and 47% for bacteria. Precision and linearity were good for both DIRUI instruments and no carryover effect was observed. Based on the results of this study DIRUI H-800 for urine chemistry combined with FUS-100 for urine sediment may led to a clinically acceptable urinalysis system. Both instruments have good precision and linearity, are free of sample carryover and they performed well both technically and operationally during the evaluation period. Unità Operativa Diagnostica Ematochimica, Azienda Ospedaliero-Universitaria di Parma, Parma. Background: Ascites, a term that defines the accumulation of fluid within the peritoneal cavity, is a frequent side effects of several localized and systemic disorders. Although the gold standard for laboratory assessment of ascites is based on manual microscopic analysis and entails total cell and cytocentrifuged differential counts, automated flow cytometry may be effective to overcome most of the drawbacks of manual enumeration and identification. Therefore, the aim of this study was to evaluate the performances of the novel Sysmex XE-5000 (Dasit SpA) for flow cytometric analysis of peritoneal fluid. Materials and methods: The comparison studies were performed by analysis of 118 consecutive peritoneal fluid samples collected from inpatients in EDTA. The white blood cell (WBC), total nucleated cell (TNC), polymorphonuclear cell (PMN), monocyte (MONO) and Other cell counts were compared with manual microscopy on Nageotte chamber after staining with Turk's and MayGrunwald-Giemsa reagents, or with results obtained on the same samples on a Sysmex XE-2100. Results: The comparison between XE-5000 and microscopic analysis yielded the following results (with mean bias and 95%CI): TNC r=0.97 (40; -110 to 180 /μL; p=0.61), WBC r=0.97 (10; -140 to 150 /μL; p=0.92), PMN r=0.95 (40; -120 to 200 /μL; p=0.62), MONO r=0.96 (10; -40 to 50 /μL; p=0.72), and Other r=0.63 (30; 20 to 40 /μL; p<0.01), with all correlations being p<0.001. The corresponding figures for comparison of XE-5000 with XE-2100 were TNC r=0.98, WBC r=0.98, PMN r=0.96, MONO r=0.98, and Other r=0.71 (all p<0.001). Even more interestingly, at the diagnostic threshold of 500 /μL for peritonitis, the agreement between XE-5000 and manual microscopy was perfect (kappa statistics 1.00; p<0.001), and thereby displaying both sensitivity and specificity of 100%. Conclusions: The results of this study reveal extraordinary performance of the Sysmex XE-5000 for flow cytometric analysis of peritoneal fluids when compared with manual microscopy, that is the current gold standard. biochimica clinica, 2012, vol. 36, n. 6 503 44° Congresso Nazionale SIBioC - Riassunti Poster P069 IS THE C3-EPIMER OF D3 RESPONSIBLE OF THE BIAS OBSERVED BETWEEN IMMUNOASSAY AND LC-MS/MS VITAMIN D DETERMINATION? P070 LA DETERMINAZIONE DELLA RENINA CON METODO CHEMIOLUMINESCENTE AUTOMATIZZATO G. Canu, J. Gervasoni, A. Cocci, C. Zuppi, C. Carrozza, S. Persichilli A. Fortunato, C. Marchetti, G. Secco, G. Soffiati Laboratorio Analisi I, Policlinico Universitario “A.Gemelli”, Roma Background: Total 25-hydroxy vitamin D concentration (25-OHD2+25-OHD3) is considered a reliable measure of vitamin D status. Results from current methods show a great inter-assays variability despite the introduction of certified reference material have enhanced agreement between different methods. Nevertheless, some unexplained factors continue to confound 25OHD measurement. Several studies indicated that the presence of 25-OHD epimer (epi-25-OHD) could be a potential confounder. The presence of this epimer was initially considered relevant only in children but recently epi-25-OHD was observed in adults. The current methods for 25-OHD determination are immunoassays and high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS). According to results of our previous paper and to literature data, a positive bias between LC-MS/MS vs immunoassays methods was found. Aim of study was to investigate if epi-25-OHD could be responsible of the bias between LC-MS/MS and immunoassay measurement. For this purpose, we analyzed vitamin D using two commercial LC-MS/MS kits of which only one able to selectively separate epi-25OHD from 25-OHD, and results were compared to an immunoassay method (ECLIA) that declare not crossreactivity with epi-25-OHD. Methods: 25-OHD levels in 50 serum samples from adult healthy subjects was measured using Liaison, automated chemiluminescence method and two different commercial kits (Chromsystem and PerkinElmer) on an HPLC-MS/ MS. PerkinElmer kit with a longer chromatographic run permits to separate epi-25-OHD from 25-OHD. Results: A general good correlation was shown among the three methods studied: DiaSorin vs PerkinElmer, R2=0.91; DiaSorin vs Chromsystems, R2=0.90; Chromsystems vs PerkinElmer, R2=0.87. Vitamin D mean concentrations obtained by the immunoassay method were lower than those measured by LC-MS/MS using both kits. The percentage difference between both LC-MS/MS and immunoassay methods ranged from from 1.0 to 25%. The presence of epi-25OHD was detected in 46 of 50 samples. The ratio (%) epi-25-OHD/25-OHD ranged from 0 to 3.0%. Conclusion: Low epi-25-OHD levels measured with PerkinElmer kit, even if observed in 92% of patients could not justify the bias between LC-MS/MS and immunoassay results. Carter GD. Accuracy of 25-hydroxyvitamin D assays: confronting the issues. Curr Drug Targets 2011;12:19-28. 506 biochimica clinica, 2012, vol. 36, n. 6 Laboratorio di Chimica Clinica ed Ematologia - Ospedale "San Bortolo" Vicenza Introduzione: la renina ha una funzione di primo piano nella regolazione della pressione arteriosa ed è coinvolto nei processi fisiologici che inducono l'ipertensione arteriosa. La determinazione dei livelli plasmatici di renina possono essere valutati per indagare l'origine di particolari forme ipertensive. In questo studio sono state valutate le prestazioni di un metodo di recente commercializzazione per la determinazione della renina attiva. Materiali e metodi: sono stati confrontati i risultati ottenuti in 136 campioni di plasma EDTA con il sistema automatizzato iSYS (IDS) rispetto a quelli ottenuti con i metodi Liaison (DiaSorin) e IRMA (CISbio) secondo le indicazioni del documento CLSI EP-9A2; negli stessi campioni è stata misurata l’attività reninica plasmatica con il metodo RIA PRA (DiaSorin). Sono state valutate anche le prestazioni analitiche del nuovo metodo secondo i documenti CLSI EP17-A per la sensibilità e EP05-A2 per la precisione. Risultati: la regressione di Passing-Bablok del sistema iSYS verso il metodo Liaison mostra una pendenza di 1,11 (IC95% = 1,07–1,13) ed una intercetta di 0,53 (IC95% = -0,24–1,22), verso il metodo CISBio mostra una pendenza di 1,11 (IC95% = 1,04–1,20) ed una intercetta di -2,34 (IC95% = -3,87–0,37), verso il metodo PRA (μU/mL vs ng/mL/h) mostra una pendenza di 41,9 (IC95% = 37,8–47,5) ed una intercetta di -7,4 (IC95% = -11,5 – -3,7). Il coefficiente di correlazione di Pearson è risultato di 0,993 (IC95%=0,991-0,995 e P <0.0001), 0,981 (IC95%=0,974-0,988 e P <0.0001) e 0,923 (IC95%=0,894-0,945 e P <0.0001) rispettivamente per iSYS verso Liaison, CISbio e PRA. Nella valutazione della ripetibilità sono stati riscontrati valori di CV compresi tra 2,5 e 5,4 per le determinazioni nella serie e tra 1,5 e 6,1 tra le serie per concentrazioni da 17,1 a 437 μU/ mL. La sensibilità analitica (LoB) è risultata di 0,9 μU/mL, mentre quella funzionale (LoQ) di 4,6 μU/mL. Nella prova di diluizione la correlazione tra valori osservati ed attesi ha mostrato una pendenza di 1,00 (IC95% = 0,985–1,023) ed una intercetta di -0,46 (IC95% = -11,5– -0,25) con un coefficiente di Pearson di 0,9996 (IC95%=0,9989-0,9999 e P <0.0001). Conclusioni: IDS-iSYS ha mostrato risultati sovrapponibili ai metodi di confronto e buone prestazioni analitiche. 44° Congresso Nazionale SIBioC - Riassunti Poster P071 LA GFR DELLA CISTATINA C: ALCUNE CONSIDERAZIONI P072 MORFOLOGIA URINARIA IN AUTOMAZIONE SU SYSMEX UF-1000i: UN PITFALL “AL FEMMINILE” L. Bassi, M. Mariani, L. Pizzi, A. Sarzi Amade', S. Sudati, S. Testa M. Fumi, M. Melorio, Y. Pancione, A. Pesaturo, V. Piscopo, S. Sale, V. Rocco Laboratorio Analisi chimico cliniche e microbiologia, Azienda Istituti Ospitalieri, Cremona UOC Patologia Clinica, A.O.R.N. "G. Rummo" di Benevento La cistatina C (Cys-C), proposta come marker di danno renale,è dipendente quasi interamente dalla GFR. La necessità di individuare un marcatore di danno renale più sensibile della creatinina e la possibilità di dosare la Cys-C su piattaforme di chimica clinica in turbidimetria rende interessante valutare un’equazione per il calcolo della GFR specifica. Scopo: Scopo è valutare una equazione per il calcolo della eGFR-Cys-C e definire un possibile valore di cut off. Materiali e metodi: Sono state dosate creatinina, con metodo enzimatico, e Cys-C,con reattivo Gentian, su strumentazione AU2700 (Beckman), su donatori uomini (159) e donne (150) e su 60 pazienti ricoverati in nefrologia e dialisi. Il calcolo della GFR della creatinina è stato eseguito secondo la formula MDRD a 4 parametri, mentre la GFR della Cys-C è stata calcolata con la formula elaborata e validata da Flodin (Scan J Clin Lab Invest 2007;67:560-7) per il reattivo Gentian (correlazione alla iohexol clearance). L’analisi statistica, eseguita con il software MedCalc, ha previsto la definizione dell’intervallo di riferimento con eliminazione degli outliers (test di Tukey), la valutazione della distribuzione normale dei dati (D’Agostino–Pearson) e il calcolo dell’intervallo al 95% lato sinistro della distribuzione. Risultati: I risultati della GFR creatinina dei donatori sono espressione di assenza di problemi renale secondo le indicazioni della linea guida NKDEP (valore minimo I pitfalls sono trappole in grado di alterare i dati numerici citometrici e che bisogna conoscere bene al fine di evitarle. Scopo del lavoro: Il riconoscimento dei pitfalls è essenziale per il miglioramento dell’accuratezza e, tutto il personale di laboratorio, che esegue e referta i test in urgenza, deve essere in grado di riconoscerli. Metodologia: Il citofluorimetro Dasit SYSMEX UF-1000i, tramite dimensionamento FSC, complessità cellulare SSC e fluorescenza alta FLH e bassa FLL, è in grado di fornire citogrammi e di distinguere le varie popolazioni cellulari urinarie, con notevole vantaggio nella individuazione delle microematurie. In alcuni pazienti, l’analizzatore forniva un dato numerico da presenza di globuli rossi non confermato né dal controllo biochimico (assenza di emoglobina), né da quello microscopico. In essi, tuttavia il citogramma di ricerca FSC/SSC evidenziava la comparsa di una “falce” costituita da elementi che, per complessità e dimensioni, venivano identificati dallo strumento come globuli rossi, determinandone così una sovrastima. Tale flag era simile a quello che gli analizzatori ematologici producono con di campioni di sangue midollare per presenza in essi di goccioline di grasso. Risultati: Il pitfall interessava circa l’1.6% dei campioni, era assente nei soggetti di sesso maschile, mentre in quelli di sesso femminile interessava solo donne di età inferiore a 65 anni. Inoltre si aveva una sua riduzione quando venivano raccolti 3 campioni per la conta di Addis. Queste valutazioni, unitamente al controllo microscopico, evidenziante formazioni che, per rifrangenza ed eterogeneità delle dimensioni, non erano classificabili come emazie, orientavano per inquinamento da detergenti. L’ipotesi veniva suffragata dalla scomparsa del flag nei soggetti interessati, al controllo eseguito dopo lavaggio dei genitali solo con acqua corrente. Conclusioni: La citofluorimetria per l’esame morfologico delle urine, è una tecnologia sensibile ed accurata che evidenzia in misura maggiore le criticità della fase preanalitica e che presuppone delle buone capacità da parte dell’operatore nell’interpretazione dei citogrammi al fine di migliorare l’accuratezza del risultato fornito. uomini 131.97 mL/min/1.73m 2 / donne 131.48 mL/ 2 min/1.73m ) e il valore minimo della GFR-Cys-C è risultato 2 71.54 mL/min/1.73m per gli uomini (CI 66.3/76.8) e 84.51 2 mL/min/1.73m (CI 78.9/90.0) per le donne. I pazienti provenienti da nefrologia e dialisi presentano per GFR 2 creatinina valori da 3.0 a 27.0 mL/min/1.73m e da 4.0 a 2 28 mL/min/1.73m per GFR Cistatina. Le due popolazioni risultano nettamente separate. Conclusioni: La GFR della cistatina può essere utilizzata per individuare pazienti con danno renale, ma utilizzando la formula validata per il metodo in uso. Gli studi in corso sulla standardizzazione del metodo potranno portare a definire un unico tipo di calcolo per GFR Cys-C e renderla un sensibile marcatore di danno renale e risolvere i problemi legati alla non uniformità dei risultati. biochimica clinica, 2012, vol. 36, n. 6 507 44° Congresso Nazionale SIBioC - Riassunti Poster P073 NUOVO METODO GC-FID PER L’ANALISI RAPIDA DEL COLESTEROLO E DEL 7-DHC DA SPOT DI SANGUE INTERO SU CARTA BIBULA PRETRATTATA CON STABILIZZANTE 1 1 1 2 S. Clericuzio , M. Gelzo , R. Barone , G. Corso , A. 1 Dello Russo 1 Dipartimento di Biochimica e Biotecnologie Mediche, Università Federico II, Napoli 2 Dipartimento di Medicina Clinica e Sperimentale, Università degli Studi di Foggia Obiettivi: 1) Implementare un metodo GC-FID per l’analisi del colesterolo (CHOL) e del 7-deidrocolesterolo (7-DHC) da spot di sangue intero (DBS) per la diagnosi della sindrome di Smith-Lemli-Opitz (SLOS). 2) Stabilizzare gli steroli nei DBS mediante l’utilizzo di un antiossidante aggiunto alla carta bibula. Metodi: I DBS sono stati preparati mediante deposizione del sangue intero su carta pre-trattata con idrossitoluene butilato (BHT). L’efficacia dell’antiossidante sulla stabilità degli steroli nel DBS è stata valutata su 5 campioni reali preparati con carta trattata e non trattata con BHT. Gli steroli sono stati determinati entro 24 h dalla preparazione dei DBS e la stabilità a 4 °C è stata monitorata per 56 giorni. Gli steroli sono stati estratti da un dischetto di 6 mm, ed analizzati mediante GC-FID in meno di 9 min. Per la validazione del metodo abbiamo valutato: selettività, linearità, imprecisione, accuratezza, efficacia di estrazione e carry-over. L’imprecisione e l’accuratezza del metodo è stata valutata su tre campioni di controllo, a differenti livelli di concentrazione (neg-QC, pos-QC-L e pos-QC-H), preparati con emazie negative mescolate a un pool di plasma negativo e due livelli di un pool positivo. Risultati: Nei DBS senza BHT, dopo 56 giorni, la concentrazione di 7-DHC ed il rapporto 7-DHC/CHOL erano ridotti del 72.7% e 80.9%. Nei DBS con BHT le variazioni osservate non erano statisticamente significative. Il metodo è risultato lineare per il CHOL da 1.72 a 110.0 mg/dL (r = 0.9993), e per il 7-DHC da 0.63 a 40.5 mg/dL (r = 0.9988). L’imprecisione e l’accuratezza nel giorno erano rispettivamente inferiori a 9.5% e 9.7% per il CHOL, e inferiori a 4.4% e -4.3% per il 7-DHC. L’imprecisione e l’accuratezza tra i giorni erano inferiori a 7.1% e 7.3% per il CHOL, e inferiori a 14.8% e -13.1% per il 7-DHC. I rapporti 7-DHC/CHOL nei DBS e nei plasmi di 8 pazienti variavano da 0.035 e 1.448 e da 0.012 e 0.926, rispettivamente, ed erano significativamente differenti dai valori ottenuti nei 30 soggetti non affetti (p<0.05). Conclusioni: L’analisi del CHOL e 7-DHC da DBS mediante GC-FID mostra buoni parametri analitici e può essere utile per lo screening della SLOS. La carta pre-trattata con BHT previene significativamente la degradazione del 7-DHC nei DBS conservati a 4 °C per almeno 56 giorni. 508 biochimica clinica, 2012, vol. 36, n. 6 P074 PERFORMANCE OF ACMIA METHOD FOR THE QUANTIFICATION OF BLOOD TACROLIMUS 1 2 1 M. Tempestilli , E. Di Stasio , M.R. Basile , F. 1 1 Elisei , L.P. Pucillo 1 Clinical Biochemistry and Pharmacology Laboratory, National Institute for Infectious Diseases “L.Spallanzani” IRCCS, Rome, Italy 2 Institute of Biochemistry and Clinical Biochemistry, Catholic University of Sacred Heart, Rome, Italy Background: Therapeutic drug monitoring (TDM) of Tacrolimus (TACRO) is particular important in patients who undergo solid organ transplantation. In fact TACRO has a narrow therapeutic range, and the failure to comply with is associated with under-immunosuppression or various toxicities and potential drug interactions. Affinity Column Mediated Immunoassay (ACMIA) a fully automated method for TDM of TACRO, not requiring the precipitation step, may represent an efficient and simple alternative to other methods that request sample preparation. The aim of this work was to compare the analytical performances of ACMIA to LC-MS/MS as the reference method. Methods: Performance characteristics of ACMIA were evaluated using samples spiked with tacrolimus and quality control materials. Two hundred and four whole blood samples from patients who received liver (n=65) or kidney (n=24) transplant were assayed by ACMIA and LCMS/MS. Standard statistical analysis was performed for methods comparison. Results: On artificially spiked samples, the average difference between results obtained by ACMIA and LC-MS/MS was 0.28±0.58 ng/mL (2.98±7.23%). Cross checking of calibrators and controls by both methods were in accordance with the nominal concentrations of TAC. The Limit of Quantification (LOQ) of ACMIA was found to be 2.8 ng/mL. The overall comparison of results obtained on 204 routine samples with the two methods generated the following results: Pearson coefficient was 0.886, p<0.0001; Spearman’s correlation was 0.906, p<0.0001. ACMIA in respect to LC-MS/MS values, gave a slope of 1.199 ± 0.044 and an intercept of 0.638 ± 0.298 by Deming regression and a mean positive bias of 1.83 ± 1.63 ng/mL by Bland-Altman analysis. Conclusions: ACMIA is a good assay for therapeutic drug monitoring of TAC, with good analytical performances when performed on samples with TACRO concentrations within the therapeutic range. Results obtained by ACMIA, must be interpreted cautiously in samples with lower TAC concentrations (<5 ng/mL). Griffey MA, Hock KG, Kilgore DC, et al. Performance of a no-pretreatment tacrolimus assay on the Dade Behring Dimension RxL clinical chemistry analyzer. Clin Chim Acta 2007;384:48-51. 44° Congresso Nazionale SIBioC - Riassunti Poster P075 PRESTAZIONI ANALITICHE DEL SISTEMA IDS-iSYS PER LA DETERMINAZIONE DEL PTH INTATTO A. Fortunato, C. Marchetti, G. Soffiati Laboratorio di Chimica Clinica ed Ematologia - Ospedale "San Bortolo" Vicenza Introduzione: Numerosi studi hanno dimostrato la mancanza di confrontabilità dei risultati ottenuti con i differenti metodi disponibili per la determinazione del PTH e la difficoltà nel raggiungere una loro adeguata standardizzazione. In questo studio sono state valutate le prestazioni del metodo IDS-iSYS Intact PTH, riguardo alla sensibilità analitica, la ripetibilità, gli intervalli di riferimento ed il confronto con altri sistemi automatizzati. Materiali e metodi: Il profilo di precisione e la sensibilità sono stati valutati con 11 pool di sieri. Per il confronto dei metodi sono stati analizzati i campioni di 218 pazienti sottoposti a dialisi (52 in dialisi peritoneale e 156 in emodialisi) e 169 soggetti, presunti sani, con i sistemi iSYS (IDS), ADVIA Centaur (Siemens) e Liaison (DiaSorin). Il calcolo degli intervalli di riferimento per i soggetti sani è stato effettuato secondo il documento CLSI C28-A3. Risultati: Nella valutazione della sensibilità analitica del metodo IDS-iSYS il valore di LoQ ottenuto è stato < 5 pg/mL. I valori di CV del profilo di imprecisione sono risultati compresi tra 0,7 e 8,3% nell’intervallo da 20,3 a 2120 pg/mL. Le equazioni di regressione trovate sono: Centaur=1,37iSYS+5,9 (r=0,995 e P<0,0001), Liaison=1,15iSYS+9,4 (r=0,934 e P<0,0001). Gli intervalli di riferimento, relativi al 95% centrale della distribuzione dei risultati ottenuti, sono risultati 10,9-71,0 11,5-50,3 e 18,0-82,0 pg/mL rispettivamente per Centaur, iSYS e Liaison. Conclusioni: Le caratteristiche analitiche del metodo IDSiSYS Intact PTH si sono dimostrate confrontabili con quelle degli altri sistemi automatizzati. Sebbene si sia dimostrata una buona correlazione tra i risultati ottenuti tra i sistemi valutati per la misura del PTH intatto, questo studio ha confermato le differenze, proporzionali ai livelli di concentrazione, tra i vari metodi. P076 PSA LIBERO E TOTALE DUE METODI A CONFRONTO: MODULAR E170 (ROCHE DIAGNOSTICS) E ADVIA CENTAUR XP (SIEMENS HEALTHCARE DIAGNOSTICS) R. Fucci , I. Paganini , F. Morandini , C. Gattini , B. Salvadori , F. Veroni , F. Martone , R. Girolami , A. Ognibene Dipartimento di Diagnostica di Laboratorio, Laboratorio Generale, Azienda Ospedaliero-Universitaria Careggi, Firenze Introduzione: La misura dell’antigene prostatico specifico (PSAt) e della sua frazione libera (PSAl) è ampiamente utilizzata nella pratica clinica come marcatore del cancro alla prostata (PCa). L’obiettivo di questo studio è di valutare i metodi di misura di questi parametri eseguiti sull’Advia Centaur XP (Siemens Healthcare Diagnostics). Materiali e metodi: La valutazione del profilo di imprecisione dei metodi è stata eseguitacome descritto nelle linee guida NCCLS (protocollo EP-5, Evaluation of Precision Performance of Quantitative Measurement Methods); a questo scopo sono stati utilizzati sieri di controllo a due diversi livelli di concentrazione (Biorad). Per il confronto tra metodi il PSA totale e libero è stato misurato in 62 campioni precedentemente analizzati con lo strumento Modular E170 (Roche Diagnostic). Il rapporto tra il PSA Libero e Totale è stato calcolato per ogni paziente. I risultati ottenuti con i due strumenti, compreso il rapporto calcolato PSAt/PSAl sono stati sottoposti ad analisi Bland-Altman e Passing-Bablok. Risultati: La valutazione dell’imprecisione intra-assay del metodo ha mostrato un CV% di 2.7 e 2.8 per il PSA totale e libero rispettivamente per il livelli 1, e un CV% di 2.3 e 1.1 per il PSA totale e libero rispettivamente per il livello 2. L’imprecisione inter-assay del metodo ha mostrato un CV % di 3.4 e 5.9 per il PSA totale e libero rispettivamente per il livelli 1, e un CV% di 3.8 e 2.4 per il PSA totale e libero rispettivamente per il livello 2. I metodi hanno rilevato una buona correlazione (PSA tot. y = 0.8973x - 0.4325, PSA libero y = 1.1514x + 0.017) ma una sovrastima sistematica del PSA libero e una sottostima meno rilevante del PSA totale. Conclusioni: I risultati ottenuti hanno dimostrato un’ottima performance analitica per i metodi oggetto dello studio, anche se, al momento dell’adozione, dovranno essere opportunamente adeguati gli intervalli di riferimento. biochimica clinica, 2012, vol. 36, n. 6 509 44° Congresso Nazionale SIBioC - Riassunti Poster P079 UN NUOVO SENSIBILE METODO PER LA RICERCA DELLA PROTEINA DI BENCE JONES SU URINE NON CONCENTRATE P080 URINE PROTEIN PROFILING BY MALDI-TOF/MS: NORMALIZATION AND REPRODUCIBILITY 1 A. Vernocchi, E. Longhi, R. Forotti, G. Lucatello Servizio di Medicina di Lab., IRCCS Multimedica, Milano La ricerca della proteina di Bence Jones (BJ) nelle urine riveste un ruolo diagnostico di grande importanza. Abbiamo valutato presso il nostro Laboratorio l’utilizzo di due anticorpi prodotti dalla ditta BIOCI (Torino), rispettivamente anti catene leggere libere (CLL) k e lambda miscelati in un unico reagente pronto all’uso. Lo scopo dello studio è stato quello di valutare la sensibilità dei due nuovi anticorpi (BIOCI) applicati a tre differenti sistemi in agarosio con metodo IFE (immunofissazione) disponibili in commercio: Hydrasys Sebia, SAS- Helena e Easy Interlab G26 – Interlab. E’ stata utilizzata per i tre sistemi una particolare mascherina con una superficie idrofoba ed una idrofila allo scopo di ottimizzare la reazione antigene-anticorpo che avviene nel gel di agarosio. Sono stati preparati due materiali a titolo noto di CLL k e lambda (separati e purificati per immunoaffinità) mediante lettura spettrofotometrica a 280 nm, allo scopo di ottenere con opportuni calcoli una concentrazione di 100 mg/L per entrambe le CLL; per verificare tale concentrazione sono stati eseguiti i dosaggi immunonefelometrico e con test colorimetrico al Pirogallolo. Le due soluzioni di CLL k e lambda sono state opportunamente diluite allo scopo di valutare la sensibilità (e la specificità) dei due nuovi anticorpi sui tre sistemi di agarosio utilizzati nello studio. Sono stati selezionati nel nostro Laboratorio 100 campioni di urine con proteina di BJ, e sono stati confrontati i risultati tra il metodo utilizzato nel nostro Laboratorio (Hydragel 4 IF- SEBIA) ed il nuovo metodo in valutazione. I tre sistemi in agarosio hanno dimostrato una elevata sensibilità, ovvero inferiore a 10 mg/L come indicato dalle linee guida, e precisamente di 6.25 mg/L sia per le CLL k, sia per le CLL lambda. In conclusione, alla luce della elevata sensibilità, della facile praticabilità, dell’uso di urine non concentrate con conseguente riduzione dei costi sia dal punto di vista dei reagenti che dei sistemi per la concentrazione delle urine, riteniamo di poter affermare che l’utilizzo di questi due nuovi anticorpi possa rappresentare un efficace sistema per la ricerca della proteina di Bence Jones nelle urine, facilmente praticabile in tutti i Servizi di Medicina di Laboratorio. 2 1 2 M. La Malfa , A. Padoan , D. Basso , C. Zambon , S. 2 2 1 2 Moz , D. Bozzato , P. Fogar , E. Greco , F. 1 3 2 Navaglia , G. Pavanello , M. Plebani 1 Department of Laboratory Medicine, University-Hospital of Padova, Padova 2 Department of Medicine – DIMED, University of Padova, Padova 3 SIPRES, Gruppo Pavanello, Padova Objectives: MALDI-TOF/MS analysis is accurate for peptides/proteins identification, but only few studies have addressed its analytical variability for the urine matrix. We evaluated intra- (CVw) and inter-assay (CVb) variability of MALDI-TOF/MS urinary profiling comparing the results obtained using three different normalization strategies: internal standard (SI), relative intensity (RI) and total ion current (TIC). Methods: Fresh urine from 10 healthy subjects were pooled, aliquoted and immediately frozen at -80 °C. To estimate CVb, every day and for 14 days one aliquot was thawed, dialyzed at 4 °C (1kDa) before MALDI-TOF/ MS analysis (Bruker Daltonics). For CVw one aliquot was thawed, dialyzed and then spitted in 20 new aliquots, which were independently analysed. Before dialysis, each urine aliquot was added with a 1589.9 m/z peptide at 12.58 pmol/uL (internal standard). Flex Analysis was used for baseline subtraction and peaks detection. Peak intensities were divided by the intensity of the internal standard (SI), the intensity of the most abundant peak (RI) or by TIC, obtained by averaging all spectra’s TIC. Results: In a mass range of 1050 to 4000 m/z, we identified from the analysis of all 14 spectra for the CVb a total of 134 peaks, and a total of 81 peaks from the 20 spectra for CVw. With the SI, RI, TIC normalization, the mean CVb% [95%CI] were: 228.9[214.1-243.6], 158.3[137.0-179.5], 156.6[135.3-177.8], while CVw% [95%CI] were: 199.9[171.9-227.8], 151.0[116.7-185.2], 149.4[115.1-183.7], respectively. These high CVs were due, at least in part, to the presence of an overall high number of low abundant features, alternatively undetectable or fairly detectable. To overcome this bias we evaluated, for each normalization method, whether a detection cut-off limit might improve CVs by checking a 0.2% to 5% range values. The best combination between CVs and the number of detectable features were 4%, 2.5% and 0.5 % for the SI, RI and TIC respectively. SI, RI, TIC mean CVb% were: 192.7[177.8-207.6], 40.1[34.2-46], 39.0[33.6-45.2], while the mean CVw% were: 120.6[108.7-132.6], 40.1[33.9-46.3], 36.9[31.1-42.8], respectively. Conclusion: For the MALDI-TOF/MS analysis of urine, TIC normalization should be preferred with respect to RI and SI. biochimica clinica, 2012, vol. 36, n. 6 511 44° Congresso Nazionale SIBioC - Riassunti Poster P081 UTILIZZO LINEE GUIDA CLSI EP-6A (CLINICAL AND LABORATORY STANDARDS INSTITUTE) PER LA VALIDAZIONE DELLA LINEARITA’ DI UN ANALIZZATORE IN CONTINUO DELLA FUNZIONALITA’ RENALE 1 1 1 1 Servizio Universitario di Medicina di Laboratorio, Ospedale di Desio, Desio (MB) 2 DIMS, Medicina e Chirurgia, Università Milano Bicocca 3 Orvim s.r.l., Paderno Dugnano (MI) 4 Kardia s.r.l., Milano Scopo: Lo strumento King (Kidney Instant MonitoringKardia-Orvim) in valutazione presso l’U.O. di Patologia Clinica dell’Ospedale di Desio è il primo analizzatore in continuo della concentrazione urinaria di ioni H+, Na+, K+, Cl-, NH4+ e della diuresi. La validazione strumentale secondo le linee guida CLSI comprende 5 fasi: 1-preliminare, 2-linearità, 3-precisione, 4-LoB (Limit of Blank) / LoD (Limit of Detection) / LoQ (Limit of Quantitation), 5-interferenti. Scopo di questo lavoro è la validazione della fase di linearità. Per linearità si intende la capacità dello strumento di fornire risultati che sono direttamente proporzionali alla concentrazione di analita presente nel campione in esame. In particolare tale fase permette di verificare il range di linearità stabilito dal produttore dello strumento in valutazione. Materiali e metodi: Tutti i campioni provengono da urine-24 ore di pazienti afferenti al Centro Prelievi dell’Ospedale di Desio. Per la fase di linearità si applicano le linee guida CLSI EP6-A1: per ogni analita (H+, Na+, K +, Cl-, NH4+) si preparano 11 campioni a concentrazione scalare e si analizzano in triplicato. Tutte le determinazioni sono eseguite in parallelo su due strumenti King 01 e King 02 e ogni analita con il metodo di riferimento: Na +/K+ = fotometria a fiamma (I.L.), Cl- = potenziometria diretta (Modular, Modulo ISE, Roche), NH4+ = colorimetria (Cobas Integra, Roche), pH = pH-metria ( Deltaohm). Risultati: I range strumentale di linearità dichiarati dal produttore (mmol/L) sono i seguenti: Cl- = 10-400, K+ = 1-150, Na+ = 1-250, pH = 3,5-8,5, NH4+ = 1-100. Conclusioni: Il nostro lavoro ha permesso di confermare su entrambi gli strumenti valutati i range di linearità dichiarati dal produttore. Sarà quindi possibile procedere alla fase di valutazione di possibili interferenti presenti in urine di pazienti ricoverati presso unità di terapie intensive. CLSI. Evaluation of the linearity of quantitative measurement procedures. CLSI document EP6-A. CLSI, Wayne, PA, 2003. biochimica clinica, 2012, vol. 36, n. 6 S. Buoro, S. Apassiti, R. Gustinetti, C. Salieri, P. Filisetti, M. Alessio, C. Galliani, P. Gherardi, E. Lochis, G. Azzara, A. Crippa 3 S. Signorelli , L. Invernizzi , R. Falbo , I. Negrelli , R. 3 4 2 Orsenigo , G. Longoni , P. Brambilla 512 P082 VALIDAZIONE DI SYSMEX UF1000I PER ESAME CITOMETRICO AUTOMATIZZATO DEL LIQUOR Lab. Analisi Chimico Cliniche, Az. Osp. Ospedali Riuniti, Bergamo Obiettivo: Nella moderna organizzazione di Laboratorio l’automazione dell’esame citometrico del Liquor (CSF) è un obiettivo cogente. Questo studio si propone di validare l’impiego di UF1000i in funzione delle specifiche e dei cutoff patologici indicati dalle Linee Guida (LG) CLSI H56-A. Materiali e metodi: 76 campioni nativi di CSF raccolti in provette sterili con cellularità da 0 a 367 WBC/μL sono stati analizzati su UF1000i. Il conteggio WBC è confrontato con metodo di riferimento MO: conteggio in camera di Nageotte e classificazione morfologica su citocentrifugato. 33 dei 76 campioni esaminati (43,4%) avevano conteggio a MO>5 WBC/μL. La concordanza tra metodi è valutata con correlazione Pearson (coefficiente r), regressione Passing-Bablok, Bias Bland-Altman; l’accuratezza diagnostica con analisi curve ROC. Su campioni omogenei, costituiti da pool di surnatanti di CSF a cui sono stati aggiunti leucociti ottenuti da buffy-coat di sangue intero, è stato valutato: il profilo di imprecisione con 10 ripetizioni su 3 campioni con valore medio di WBC da 3,5 a 28,8/μL; il carry over (CO) secondo LG ICSH 1994 su campioni in tre serie distinte con WBC da 93 a 132/μL. Risultati: Si evidenzia ottima correlazione per il conteggio WBC (r=0.99; y=0.93x+0.07) con bias di 3.5 (IC 95% da -7.0 a 0.0). L’analisi delle curve ROC, a cut-off di UF1000i = 4 WBC/μL mostra le seguenti performance diagnostiche rispetto a MO: sensibilità=100% (0 Falsi Negativi), specificità=83,7% (7 Falsi Positivi), concordanza diagnostica: 90,9%, Valore Predittivo Negativo=100%, Valore Predittivo Positivo= 82,9%. Il CO è assente (valore massimo=0,22% nelle tre serie di campioni). Il profilo di imprecisione evidenzia CV<20% anche nel campione con WBC=3,5/μL (CV=16,5%). Conclusioni: I risultati evidenziano ottima concordanza dei conteggi di UF1000i rispetto al metodo di riferimento in MO, ottime prestazioni di imprecisione e CO assente. Le performance diagnostiche a cut-off di 4 WBC/μL sono caratterizzate da concordanza diagnostica del 90.9% e VPN del 100%. I citogrammi di UF1000i forniscono inoltre un valido supporto all’analisi morfologica. I dati confermano il suo possibile impiego nei percorsi di automazione dell’analisi citometrica di CSF rispetto ai contenuti di LG CLSI H56-A. 44° Congresso Nazionale SIBioC - Riassunti Poster P083 VALUTAZIONE DEGLI INTERVALLI DI RIFERIMENTO E DELLE PRESTAZIONI ANALITICHE DEL TEST CISTATINA C TRAMITE L’USO DI DUE REAGENTI DI PRODUZIONE DI DUE DITTE DIFFERENTI L. Bassi, M. Mariani, L. Pizzi, A. Sarzi Amade' , S. Sudati, S. Testa Laboratorio analisi chimico cliniche e microbiologia, Azienda Istituti Ospitalieri, Cremona La Cistatina C (Cys-C), proteina basica non glicosilata prodotta da quasi tutte le cellule nucleate, è filtrata dal glomerulo e quasi interamente catabolizzata dal tubulo. La Cys-C è stata recentemente proposta come marcatore di funzionalità renale più sensibile della creatinina serica principalmente nei pazienti con lieve riduzione della GFR e a rischio cardiovascolare. Scopo: Lo scopo del lavoro è valutare i range di riferimento della Cys-C (Gentian), rispetto quelli della CysC (Sentinel). Materiali e metodi: Sono state valutate: •stabilità del reattivo e prestazioni del metodo; •livelli decisionali per fasce di età e sesso. Sono stati utilizzati plasmi di donatori, per definire gli intervalli di riferimento, per sesso e fasce di età (circa 30 pazienti per gruppo con età inferiore a 20 anni, tra 20/30, tra 30/40, tra 40/50 e oltre 50) e per il confronto tra metodi, plasmi di pazienti con danno renale. In ogni gruppo di pazienti è stata dosata anche la creatinina. I calcoli statistici sono stati eseguiti utilizzando il programma statistico MedCalc. Risultati: •Il reattivo in valutazione ha mostrato una calibrazione per lotto stabile nel periodo della prova (45 giorni). I controlli strumentali hanno evidenziato un CV% di 5.69 per il livello1 (atteso 0.90 mg/L/ottenuto 0.88 mg/L), un CV% di 5.29 per il livello2 (atteso 2.89 mg/L/ottenuto 2.75 mg/L); •I calibratori Gentian sono pronti all’uso, mentre quelli Sentinel richiedono diluizioni a raddoppio manuali con possibilità di non precisa diluizione e problemi in calibrazione; •L’intervallo di riferimento, calcolato sui donatori, con eliminazione degli outliers (test di Tukey), è risultato pari a 0.52/1.03 mg/L in linea con i dati forniti dalla ditta (0.53/1.01 mg/L); •Non si sono evidenziati variazioni degli intervalli di riferimento per sesso e fasce di età con il metodo in valutazione; •Il coefficiente di correlazione calcolato su 62 pazienti afferenti al laboratorio dai reparti di nefrologia e dialisi ha un valore pari a 0.9806 e l’equazione della retta di regressione Y=0.462+0.7061X. Conclusioni: Il metodo in valutazione ha dimostrato buona stabilità e precisione con valori di concentrazione senza differenze significative per età e sesso. L’introduzione in routine può prevedere un unico intervallo di riferimento. P084 VALUTAZIONE DELLA PERFORMANCE ANALITICA DELL'ANALIZZATORE AUTOMATICO COBAS C311 A. Primiano, A. Schiattarella, K. Pocino, C. Zuppi, M. Antenucci Lab. di Analisi I, Policlinico Universitario A.Gemelli, Roma Introduzione e scopo: Nell’ambito della riorganizzazione e del consolidamento del Laboratorio di Analisi I, la determinazione quantitativa degli analiti urinari che precedentemente veniva eseguita sull’analizzatore AU2700 (Beckman Coulter) è stata implementata sull’analizzatore automatico Cobas C311 (Roche Diagnostics). Pertanto abbiamo valutato la performance analitica di tale analizzatore confrontando i risultati con quelli ottenuti dal sistema precedentemente utilizzato. Materiali e metodi: Sono stati analizzati 100 campioni di urine delle 24 ore provenienti dai reparti interni ed esterni del nostro Policlinico e sono stati dosati i seguenti parametri: glucosio, Na, K, Cl, Ca, Crea, P, urea, acido urico, Mg, amilasi e proteine totali. La precisione, l’accuratezza, e la correlazione con i metodi in uso sono stati valutati in accordo con i protocolli NCCLS/ CLSI. Per entrambi gli analizzatori sono stati utilizzati reagenti, calibratori e controlli delle rispettive case produttrici. La differenza sostanziale tra i due analizzatori consiste nell’utilizzo di diversi calibratori: AU2700 (Beckman Coulter) utilizza un calibratore specifico, su matrice umana, per i campioni di urine, mentre il Cobas C311 (Roche Diagnostics) fa riferimento alle calibrazioni effettuate su matrice proteica, tranne che per il dosaggio delle proteine urinarie. Risultati e conclusioni: Il confronto tra i metodi, effettuato attraverso l’analisi della regressione lineare di Pearson e il Bland-Altman plot, ha evidenziato una buona correlazione tra i due strumenti (AU2700 e Cobas C311): tutti gli analiti dosati, infatti, presentano un ottimo coefficiente 2 di correlazione (r >0,990) e un bias non significativo. La precisione intra-serie e inter-serie mostra coefficienti di variazione (CV) compresi rispettivamente tra 0.54% 2.97% e 1.2% - 5.0%. La valutazione della performance analitica e il confronto tra i campioni dimostra che i due sistemi forniscono risultati sovrapponibili, e quindi possono essere indifferentemente utilizzati in base alle specifiche esigenze. biochimica clinica, 2012, vol. 36, n. 6 513 44° Congresso Nazionale SIBioC - Riassunti Poster P085 VALUTAZIONE DELLE PRESTAZIONI ANALITICHE DEL SISTEMA ANALITICO ALERE NS-PLUS PER LA DETERMINAZIONE IMMUNOCHIMICA QUANTITATIVA DELLA TRANSFERRINA FECALE 1 1 2 1 L. Bressan , N. Corcione , D. Dama , P. Luraschi P086 VALUTAZIONE DI SENSIBILITA’ E SPECIFICITA’ DI TRE REAGENTI APTT PER LA DIAGNOSI PRECOCE DI LUPUS ANTICOAGULANTE L. Loiodice, P. Ranieri, L. De Marinis, F. Catacchio, A. Lamanna, S. Petruzzellis, A. Sollecito, L. Varraso, F. Di Serio 1 Lab. Medico, Dip. di Prevenzione Medico, ASL Varese Corso di Laurea in Tecniche di Laboratorio Biomedico, Facoltà di Medicina e Chirurgia, Università degli Studi dell'Insubria, Varese-Como 2 La transferrina (Tf) è una ß1-globulina con PM da 75 a 80 kDa e compare nelle feci in seguito a sanguinamento del tratto gastro-intestinale. Rispetto all’emoglobina (Hb), Tf è più stabile alle alte temperature e maggiormente resistente all’attacco batterico; la determinazione della Tf nelle feci è stata proposta, in aggiunta alla ricerca della Hb, in quanto permetterebbe di rivelare sanguinamenti che potrebbero sfuggire con la sola ricerca della Hb (stadi precoci del cancro del colon-retto, polipi del colon). La misurazione della Tf fecale è stata effettuata con strumento NS-Plus prodotto da Otsuka Electronics, utilizzando reagenti, materiali di controllo e dispositivi monouso prodotti da Alfresa Pharma Corporation e commercializzati da Alere. Per la raccolta del campione viene utilizzato un dispositivo monouso che permette il prelievo di una quantità standardizzata di feci e la diluizione in un volume predeterminato di tampone. La misurazione della concentrazione della Tf avviene con metodo immunochimico abbinato alla spettrofotometria con oro colloidale. Si sono valutate le caratteristiche di imprecisione (nella serie e tra le serie) a differenti livelli di concentrazione, linearità, sensibilità analitica (mediante calcolo del LOD in accordo con il documento CLSI EP17A), ed esattezza analitica. L’imprecisione entro la serie (CV%) è risultata compresa tra 0,9 % e 23,6 % per concentrazione di Tf di 209 e 6 ng/mL, rispettivamente. Il profilo di imprecisione ha mostrato la classica conformazione a U, con deterioramento dell’imprecisione agli estremi dell’intervallo analitico. L’imprecisione tra le serie (CV%) è risultata 7,4% e 6,4% per concentrazioni di 46 e 154 ng/mL, rispettivamente. Il metodo ha mostrato linearità e buon accordo trovato/atteso (regressione trovato/atteso: pendenza 1,02; intercetta 1,1 ng/mL; r 0,999) nell’intervallo di concentrazione 5-500 ng/ mL. Il valore del LOD è risultato pari a 1,52 ng/ mL. In conclusione il sistema analitico ha mostrato soddisfacenti caratteristiche di accuratezza analitica, adeguate all’utilizzo clinico previsto. 514 biochimica clinica, 2012, vol. 36, n. 6 U.O. Patologia Clinica I Azienda Ospedaliera Universitaria Policlinico Consorziale di Bari Scopo: Valutare la sensibilità e la specificità di valori di APTT ottenuti con tre reagenti a diversa composizione fosfolipidica e di attivatori, per una diagnostica precoce di Lupus anticoagulante (LA). Materiali e metodi: Sono stati selezionati 50 campioni di plasma raccolti da soggetti sani e 26 campioni di pazienti, afferenti al Centro Emostasi e Trombosi, per i quali i test di 2° livello avevano confermato la diagnosi di LA. In tutti i campioni, l’APTT è stato misurato sull’analizzatore CA 7000 Siemens utilizzando tre differenti reagenti: Actin FS (Siemens), Pathromtin SL (Siemens), APTT SP (Instrumentation Laboratory). Nell’indagine statistica, per la valutazione dei risultati, sono stati utilizzati il test di Student per dati non appaiati, l’analisi di Bland ed Altmann e la formula di Bayes. Risultati: Nei soggetti sani, il confronto tra metodi mostra che i valori di APTT (Actin FS: media = 27.4, DS=2.4; Pathromtin SL: media=34, DS=4.0; APTT SP: media=29.2, DS=4.9) non sono significativamente differenti solo per misurazioni eseguite con Actin FS e con APTT SP (p = 0,13). I risultati ottenuti da pazienti LA positivi (Actin FS: media = 31,5, DS = 7,6; Pathromtin SL: media = 61,4, DS = 26; APTT SP: media = 77,2 DS = 35,2) evidenziano una differenza statisticamente non significativa solo tra Pathromtin SL vs APTT SP (p = 0,075). L’analisi di B.A. evidenzia i seguenti bias: Actin FS e Pathromtin SL -29 ( IC 95% da -38 a -21 ); Pathromtin SL e APTT SP -15.7(IC 95% da -26 a 5.5); Actin FS e APTT SP -45 (IC 95% da -59 a 32). Sensibilità e specificità: Actin FS = 0.52 e 1 rispettivamente; Pathromtin SL e APTT SP = 1. Conclusioni: l’Actin FS non mostra la stessa predittività degli altri reagenti, nella precoce identificazione di pazienti con LA, pertanto, nella scelta del metodo da utilizzare, deve essere considerata la prevalenza della popolazione afferente al laboratorio. 44° Congresso Nazionale SIBioC - Riassunti Poster P087 VALUTAZIONE IN UN LABORATORIO CENTRALIZZATO DI UN SISTEMA EVOLUTO INNOVATIVO DI EMOGASANALISI P088 VALUTAZIONE PRELIMINARE CIRCA L’IMPATTO DELLE MANUTENZIONI SUI RISULTATI ANALITICI DELLA TROPONINA RICHIESTA IN URGENZA B.C. Creanza, M. Guida, G. Dirienzo S. Gelsumini , R. Serdi , E. Stenner , E. Gianoli , G. 1 2 Paladini , G. Paladini ASL BARI - Struttura Complessa di Patologia Clinica Ospedale Civile Umberto I - Altamura, Bari Le performance analitiche dei risultati ottenuti mediante l’utilizzo di un sistema evoluto di emogasanalisi possono essere qualitativamente allineate ai sistemi di riferimento di laboratorio. Sono state effettuate due differenti valutazioni: 1. Valutazione delle prestazioni dell’ABL 825 FLEX dotato del proprio dispositivo per la gestione in completa automazione della fase preanalitica in termini di correlazione dell’emoglobina con la valutazione dell’indice di correlazione R2 rispetto allo strumento di riferimento ABX Pentra DX 120. 2. Ripetibilità intraserie del glucosio e di elettroliti (cloro, sodio e potassio), rispetto allo strumento di riferimento AU480. Le strumentazioni protagoniste di questa valutazione sono: Modello emogasanalizzatore ABL 825 FLEX (Radiometer Medical); Dispositivi di prelievo utilizzati: siringhe pre-eparinate SafePICO di Radiometer Medical ApS in abbinamento al sistema di miscelazione automatica e standardizzata del campione integrato nell’emogasanalizzatore; Modello analizzatore Laboratorio: ABX Pentra DX 120 (Horiba); Modello analizzatore Laboratorio: AU 480 (Beckman Coulter). Correlazione ctHb: le analisi sono state condotte eseguendo in successione 43 campioni di pazienti provenienti da reparti ed eseguiti “random” sui due strumenti. I dati ottenuti sono stati valutati attraverso il metodo della regressione lineare e calcolo del coefficiente R2. Ripetibilità intraserie glucosio e elettroliti (K+, Na+, Cl-): la valutazione è stata condotta attraverso analisi ripetute di un pool di sieri replicati per 21 volte di cui 2 campioni hanno presentato problemi di aspirazione, pertanto non inclusi nella valutazione. Il sistema ABL825 FLEX fornisce una buona correlazione con lo strumento di riferimento nella valutazione dell’emoglobina, grazie alla combinazione dei dispositivi di prelievo safePICO e grazie al modulo FLEXQ [campionatore automatizzato, in grado di eseguire i campioni dopo averli miscelati grazie alla presenza di una mixing ball presente all’interno della SafePICO]. Il dispositivo utilizza un disco in fibra rivestito con 60 U.I. di eparina liofila che non interferisce sui risultati finali dell’esame. Bonini P, Plebani M, Ceriotti F, et al. Errors in laboratory medicine. Clin Chem 2002;48:691-8. 1 1 1 1 1 Dip. di Medicina di Laboratorio, Azienda Ospedaliera “Ospedali riuniti”- Trieste 2 Dip. di Onco-Ematologia, Azienda Ospedaliera “Ospedali riuniti”- Trieste Nel Laboratorio Urgenze dell’Azienda Ospedaliera “Ospedali Riuniti” di Trieste (sede di Cattinara), le richieste di troponina vengono processate sull’analizzatore Access2 (Beckman Coulter), con metodo AccuTnI. Scopo: Valutare l’impatto delle manutenzioni sui risultati analitici della troponina urgente. Metodologia: Sono stati arruolati i campioni urgenti di plasma (raccolti in provette con litio-eparina e centrifugati a 4.000 rpm per 5 min) con le seguenti concentrazioni di troponina: 19,6 μg/L; 106,06 μg/L; 124,55 μg/L; 257,70 μg/ L; 292,37 μg/L; 349,05 μg/L; <0,01 μg/L. I campioni sono stati processati in serie, secondo lo schema seguente: a) 2 replicati di materiale di controllo basso (Seronorm); b) 3 replicati di un pool ricavato da campioni con TnI <0,01 μg/ L; c) campione critico; d) 3 replicati di un pool ricavato da campioni con TnI <0,01 μg/L; e) 2 replicati di materiale di controllo basso (Seronorm). Campioni con TnI >102,000 μg/L, corrispondente al limite di linearità del metodo, sono stati diluiti 1:5 con diluente dedicato. Risultati: Dopo il processamento di ogni campione critico (c), i risultati relativi ai tre replicati del pool (d) sono stati i seguenti: - non sono stati rilevati risultati falsamente positivi rispetto al cutoff in uso (0,06 μg/L); - solo in un caso il risultato è stato 0,01 μg/L (corrispondente al limite di sensibilità analitica del metodo); - gli altri risultati sono stati < 0,01 μg/L. Discussione e conclusioni: Data l’elevata frequenza quotidiana delle richieste urgenti di troponina, le azioni di manutenzione sullo strumento Access2 sono state riviste. Nel nostro Laboratorio, quindi: la manutenzione settimanale (Special Clean) viene eseguita con cadenza giornaliera; c’è attenzione a mantenere costante la temperatura ambiente, evitandone gli sbalzi repentini. Quindi, l’attenzione alle manutenzioni è, verosimilmente, responsabile della bontà dei risultati analitici, confortati anche dall’assenza di reclami e/o richieste di chiarimenti da parte dei clinici circa tali esiti, sempre agendo nell’ottica della salvaguardia dell’outcome del paziente. Dimeski G, Jones B, Brown N. Carryover can be a cause of false-positive results with the Beckman AccuTnI assay. Clin Chem Lab Med 2012;50:1135-6. biochimica clinica, 2012, vol. 36, n. 6 515 44° Congresso Nazionale SIBioC - Riassunti Poster P089 VALUTAZIONE PRELIMINARE DELL'ANALIZZATORE CHEM 400 ISE - GESAN D. Cerasuolo, L. Russo, E. De Iuliis, F. Di Paola, E. Cavalcanti S. C. Medicina di Laboratorio, I.N.T. - IRCCS, Fondazione G. Pascale, Napoli Si riportano i risultati di uno studio preliminare sulle caratteristiche dell’analizzatore CHEM 400 ISE, commercializzato dalla GESAN Production (TP), la cui cadenza analitica è di 400 esami/ora (580esami con ISE incluso). Lo strumento può analizzare simultaneamente un massimo di 70 campioni con caricamento in continuo ed identificazione positiva di reagenti e campioni mediante bar code. Le caratteristiche di riproducibilità sono state studiate valutando l’imprecisione nella serie e tra le serie per alcuni analiti (albumina, proteine totali, colesterolo, colesterolo HDL, trigliceridi, sodio, potassio e calcio totale), rappresentativi delle varie possibilità operative dello strumento; la prima analizzando tre pool di sieri da pazienti a diverse concentrazioni (20 repliche) e la seconda utilizzando i valori (n=20) relativi a due sieri di Controllo Normale e Patologico. Reagenti, calibratori e controlli erano forniti dalla ditta GESAN. Entrambe le imprecisioni si sono rilevate trascurabili (pool basso: CV% 4,0 ÷ 5,6; pool normale: CV% 0,58 ÷ 3,29; pool alto: CV% 0,80 ÷ 1,80; Controllo Normale CV% 2,5 ÷ 5,0; Controllo Patologico CV% 2,4 ÷ 5,5). Gli stessi metodi sono stati, inoltre, confrontati con quelli implementati sull’analizzatore Cobas C6000 (Roche Diagnostics) utilizzato nel nostro laboratorio. Questa correlazione è stata eseguita su 100 sieri da paziente a diversi livelli di concentrazione per tutti gli analiti esaminati. I valori ottenuti sono stati valutati mediante analisi della regressione lineare ed il calcolo del coefficiente di correlazione r. I risultati sono del tutto soddisfacenti (r= 0,89 ÷ 0,99), tranne per sodio e potassio per i quali probabilmente si verificano fenomeni di carryover da reagente. Analizzati singolarmente, infatti, la correlazione migliora significativamente. E’ stata valutata altresì la metodica per il dosaggio del calcio ionizzato, implementata su entrambe le strumentazioni, (reattivo fornito dalla ditta GESAN), che ha mostrato buone caratteristiche di imprecisione (CV% 5,0) nonchè di correlazione tra i due analizzatori (r=0,89) e tra questi ed il dosaggio in emogas-analisi (r=0,9). 516 biochimica clinica, 2012, vol. 36, n. 6 P090 VALUTAZIONE PRELIMINARE DELLE PRESTAZIONI ANALITICHE DI MAGLUMI 2000 PLUS PER LA MISURA DI FERRITINA, MIOGLOBINA E CK-MB G. Grandi , F. Veroni , G. Avveduto , F. Fissi , M. Monti , A. Neri , F. Daniele , D. De Ninno , D. Tinalli Laboratorio Generale, Dipartimento Diagnostica di Laboratorio, Azienda Ospedaliero Universitaria Careggi, Firenze Scopo dello studio è stata una valutazione preliminare delle prestazione analitiche del nuovo strumento Maglumi 2000 Plus, prodotto da SNIBE e distribuito in Italia da Medical System. Lo strumento, che sfrutta un sistema immunoenzimatico sandwich con anticorpi monoclonali e rivelazione in chemiluminescenza, può misurare un ampio repertorio di analiti in grado di soddisfare le diagnostiche biochimiche maggiormente diffuse, tra i quali per una prima valutazione delle prestazioni di Maglumi 2000 Plus, sono state prese in esame la ferritina, la mioglobina e il CK-MB. La misura di questi tre analiti è stata eseguita su 60 campioni, reclutati dalla routine del nostro laboratorio e i risultati confrontati con quelli ottenuti su Advia Centaur (Siemens). Le rette di regressione, rispettivamente di ferritina, mioglobina e CK-MB, sono 2 risultate y = 0,825x–5,411 (R = 0,965; range 13 – 542 2 ng/mL), y = 0,916x – 10,4 (R = 0,979; range 18 – 1114 2 ng/mL), y = 1,347 x + 3,358 (R = 0,979; range 0.3 – 188 ng/mL ). Utilizzando gli intervalli di riferimento in uso per i risultati ottenuti su Advia Centaur e quelli indicati dalla ditta per Maglumi 2000 Plus, la concordanza tra i due metodi è risultata dell’86% per la ferritina, del 96% per la mioglobina e del 98% per il CK-MB. Lo studio di imprecisione effettuato secondo il protocollo NCCLS EP5A2 e su tre livelli di concentrazione, ha evidenziato un CV intra-assay inferiore al 10% e un CV inter-assay inferiore al 15% per tutti e tre gli analiti. In conclusione, i risultati preliminari delle prestazioni analitiche dello strumento Maglumi 2000 Plus per i tre analiti testati sono stati soddisfacenti e compatibili con l’uso clinico. Questo dato, se confermato anche sugli altri test proposti dalla ditta, insieme alla elevata produttività strumentale (180 test/ ora), al confezionamento dei reattivi (liquidi con calibratori inclusi), alla facilità d’uso del software e l’ampia capacità di reattivi on-board, lo rendono uno strumento molto versatile e potenzialmente interessante per l’ampiezza del menu. 44° Congresso Nazionale SIBioC - Riassunti Poster P091 VANTAGGIO DELLA VALUTAZIONE PRELIMINARE CON LINEE GUIDA CLSI EP10-A3 (CLINICAL AND LABORATORY STANDARDS INSTITUTE) DI UN ANALIZZATORE IN CONTINUO DELLA FUNZIONALITÀ RENALE PER IL MIGLIORAMENTO DELLA PRECISIONE 1 1 1 3 L. Invernizzi , S. Signorelli , R. Falbo , I. Negrelli , R. 3 4 2 Orsenigo , G. Longoni , P. Brambilla P092 ANALYTICAL PERFORMANCE OF NOVEL IMMUNOENZYMOMETRIC ASSAY FOR cTnI COMPARED WITH OTHER cTnI AND cTnT IMMUNOASSAYS 2 1 1 3 M. Franzini , C. Prontera , S. Masotti , G. Zucchelli , S. 1 1 1 2 Storti , D. Chiappino , D. Della Latta , C. Passino , M. 1 1 Emdin , A. Clerico 1 1 Serv. Univ. di Med. di Laboratorio Osp. di Desio, Desio (MB) 2 DIMS, Medicina e Chirurgia, Univ. Milano Bicocca 3 Orvim s.r.l., Paderno Dugnano (MI) 4 Kardia s.r.l., Milano Scopo: Lo strumento Kidney Instant Monitoring (Ki.n.g) (Orvim Kardia) è il primo analizzatore automatico in continuo di urina che determina la diuresi e la concentrazione di H+, Na+, K+, Cl- e NH4+. Scopo del lavoro è effettuare, per ogni analita analizzato, una valutazione preliminare dell’imprecisione per mettere in evidenza eventuali problematiche strumentali e correggerle prima di procedere con la fase di valutazione della precisione. Materiali e metodi: I campioni provengono dalla raccolta di urine-24 ore di pazienti del Centro Prelievi dell’Ospedale di Desio. Fase preliminare: per ogni analita si applicano linee guida CLSI EP10-A3: 2 serie di analisi per 5 giorni consecutivi su pools di materiale con 3 concentrazioni diverse di analita: Low (L), Mid (M) e High (H). Fase di Precisione: per ogni analita si applicano linee guida CLSI EP5-A2: 2 campioni a concentrazioni diverse di analita analizzati in 2 serie separate per 20 giorni in triplicato. Le analisi sono condotte in parallelo su 2 strumenti e confrontate con il metodo di riferimento. pH: pH-metria (Delta Ohm); Na+/K+: fotometria a fiamma (I.L.); Cl-: potenziometria indiretta (Modular, Modulo ISE, Roche); NH4+: colorimetria (Cobas Integra, Roche). Risultati: I due strumenti sono sovrapponibili. La fase preliminare ha permesso di apportare interventi per migliorarne la performance: modifica rette calibrazione e fattori correzione; modifica elettrodi; modifica diametri del sistema di aspirazione e fluidica; modifica elettrovalvola e sistema campionatore. Si è quindi dimostrato un notevole miglioramento della precisione. Il CV% del metodo, infatti, per tutti gli analiti è risultato ≤ al limite di accettabilità per il CV% (15%). Conclusioni: I risultati dimostrano l’importanza della fase preliminare nella validazione strumentale. L’elevata precisione dello strumento lo rende adatto all’uso come point of care testing (POCT) in unità di terapia intensiva per la valutazione ed il monitoraggio in continuo della funzionalità renale. CLSI. Preliminary evaluation of quantitative clinical laboratory measurement procedures. CLSI document EP10-A3. CLSI, Wayne, PA, 2006. Fondazione Toscana G. Monasterio, Pisa Scuola Superiore Sant’Anna, Pisa 3 QualiMedLab & Istituto di Fisiologia Clinica - CNR, Pisa 2 Background: We evaluated the analytical performance and the clinical results of a novel immunoenzymometric assay for the cTnI using the automated AIA platform. Methods: The third generation AIA-Pack method for plasma cTnI assay was performed in our laboratory according to the recommendations made by the manufacturer, using the AIA-2000 platform (TOSOH Corporation). For comparison, plasma concentrations of cTnI were also measured using the Access AccuTnI method with the UniCell DxI 800 platform (BeckmanCoulter Diagnostics). Results: The limits of blank (LoB) and detection (LoD) for the third generation AIA-Pack method were determined according to the CLSI EP17-A protocol in heparinized plasma samples. The calculated LoB and LoD values were 3.5 ng/L and 8.7 ng/L, respectively. Moreover, the limits of quantitation (LoQ) at 20% CV and 10% CV were 30 and 100 ng/L of cTnI, respectively. A close linear relationship (R=0.999, plasma= 3.10 + 0.95 serum) was found between cTnI concentrations measured in 105 serum and heparinized plasma samples of healthy subjects and patients with cardiac diseases. TOSOH method showed a close correlation (R=0.991) ma also a mean negative bias (i.e., underestimation) of -30.2 % compared to Beckman-Coulter. The distribution of cTnI values, measured by the TOSOH method, was evaluated th in 452 healthy individuals. The calculated 99 percentile of the cTnI values was 33 ng/L (median 9.0 ng/L, range 0-44 ng/L). Conclusion: Our data suggest that the analytical performance of the third-generation AIA-Pack assay should be considered to be as clinically acceptable for the evaluation of patients with cardiac diseases. Clerico A, Giannoni A, Prontera T, et al. High-sensitivity troponin: a new toll for pathophysiological investigation and clinical practice. Adv Clin Chem 2009;49:1-30. biochimica clinica, 2012, vol. 36, n. 6 517 44° Congresso Nazionale SIBioC - Riassunti Poster P093 COST-BENEFIT ANALYSIS OF COPEPTIN COMBINED WITH TROPONIN I FOR EXCLUSION OF ACUTE MYOCARDIAL INFARCTION P094 CTNT FOURTH GENERATION VS CTNT-ULTRA ASSAY: IMPACT ON EMERGENCY DEPARTMENT S. Valenti, G. Andalò 1 2 2 2 D. Cosseddu , G. Alberto , L. Arnaldi , C. Runzo , S. 1 4 4 Musolino , G.M. Bruno , S. Di Matteo , G.L. 3 2 1 Colombo , A. Soragna , M. Migliardi 1 S.C. Analysis laboratory – A.O. Ordine Mauriziano di Torino - Turin (Italy) 2 DEA – A.O. Ordine Mauriziano di Torino - Turin (Italy) 3 University of Pavia, Dpt. of Pharmaceutical Sciences, Faculty of Pharmacy - Pavia (Italy) 4 S.A.V.E. Studi Analisi Valutazioni Economiche Srl – Milan (Italy) Objective: We developed a cost-benefit analysis in the use of copeptin for rapid rule out of acute myocardial infarction (AMI) in the Department of Emergency-Urgency (DEA). Methods: We defined a theoretical decision tree model based on differential costs for patients with chest pain and non-significant ECG that arrived in DEA. Patients were divided into two branches: those that had only troponin I measured vs patients with measurements for both troponin and copeptin. Patient cost for the two biomarkers, a flat fee for the equipment of analysis of copeptina was enhanced. Finally we hypothesized two evaluations for the use of health care resources and medical staff: in the first scenario, costs for each item were valorized (medical staff, monitoring room, exam fees), in the second a rate of "astanteria" consisting of direct costs and diagnostic tests was used. The model was then adapted to the clinical experience of DEA Mauriziano Hospital of Turin in 2011. Results: Cost-benefit analysis showed that the number of patients in the copeptin group that would have required a 3rd troponin sample would have been 47 vs 161, freeing up medical resources and monitoring room. The use of copeptin saved, approximately 5 h and 41 min. Enhancement of the freed time, could have theoretically resulted in savings of about €75 per patient, with a costbenefit ratio equal to 4.25. Using costs for the rate of "astanteria", the savings per treated patient goes up to about €125, with a cost benefit ratio of 7.13. Costbenefit analysis has therefore determined that every euro invested in copeptin determines a health benefit in the range of EUR 4.25 to 7.13 for the Hospital. Conclusion: The fast exclusion of AMI in patients with chest pain is strategic because we need to reduce health care costs without compromising patient safety. Our results highlight the role of copeptin as a cost-benefit tool to rule out AMI, so as to significantly reduce the length of stay in the DEA and thereby generate savings of health care resources and better organization of working time for medical and nursing staff. Drummond MF, O'Brien BJ, Stoddart GL, et al. Methods for the economic evaluation of health care programmes. Third edition. New York: Oxford University Press, 2006. 518 biochimica clinica, 2012, vol. 36, n. 6 Laboratorio a Risposta Rapida Azienda USL di Ravenna In Ravenna hospital, we have used cardiac troponin since 1996. In 2002 Emergency Department, organized in three hospitals with 140-150000 health services per year, introduced a protocol for Chest Pain. The Short–Stay Observation for Chest Pain was gradually shortened in conjunction with the increase of assays sensitivity used in laboratory for cardiac markers analysis. In all laboratories of Area Vasta Romagna we use only cTnT-ultra assay from Roche and this reduced Short-Stay Observation from 9 hours to 3-6 hours in February 2011. At first the report showed a “double cut-off”: one was 99° percentile value, the other was the previous assay cut-off (cTnT fourth generation), respectively for the rule-out and the rule-in of patients. Patients with values between first and second cut-off received a second sample according with literature. In September 2012 the report has been modified and shows only 99° percentile value. The main outcome of cTnT-ultra assay usage is the decrease of Short-Stay Observation for chest Pain to 3-6 hours and the removal of myoglobin assay, sensitive but not specific marker. There wasn’t an increase of troponin assay request but a initial decrease of 8.6% from Emergency Department. We regularly check the assay results through the Information Data Base and we can confirm that patients with positive value are increased by about 25%. “New positive” patients follow-up is still underway. 44° Congresso Nazionale SIBioC - Riassunti Poster P095 EFFETTI DELLA SUPPLEMENTAZIONE DI VITAMINA D SUI LIVELLI DI PTH E FGF-23 NELL'INSUFFICIENZA CARDIACA: RISULTATI PRELIMINARI A 3 MESI DAL TRATTAMENTO 1 1 2 3 P096 EPIDEMIOLOGICAL ASSOCIATION OF INCREASED HEMOGLOBIN VALUES WITH UNFAVORABLE LIPID PROFILE IN A LARGE POPULATION OF UNSELECTED OUTPATIENTS 1 2 2 S. Scarlini , F. Turrini , T. Trenti , E. Baraldi , M.C. De 3 3 Santis , L. Roli G. Lippi , M. Montagnana , E. Danese , G.L. 2 2 Salvagno , G.C. Guidi 1 1 Medicina Interna Cardiovascolare, Nuovo Ospedale Civile S. Agostino - Estense, Modena 2 Dipartimento di Patologia Clinica, Nuovo Ospedale Civile S. Agostino - Estense, Modena 3 Laboratorio di Patologia Clinica Endocrinologia, Nuovo Ospedale Civile S. Agostino - Estense, Modena Razionale: Tra gli effetti della supplementazione di Vit.D nell’insufficienza cardiaca (IC) vi è la riduzione dell'iperparatiroidismo secondario in cui l'eccesso di PTH causa ipertofia dei cardiomiociti e fibrosi interstiziale. Studi clinici suggeriscono che l'aumento precoce di FGF23 causerebbe declino dei valori di Vit.D e iperparatiroidismo secondario, venendo meno la fisiologica inibizione di feedback sul PTH della Vit.D. Scopo: Per investigare gli effetti a breve termine della supplementazione di Vit.D in soggetti con IC (classe NYHA II-III, età>60 anni, ipovitaminosi D, stabilità clinica da un mese, GFR>30 mL/min) su PTH e FGF23, abbiamo confrontato 16 soggetti in trattamento con Vit.D (300000U carico + 50000U/mese) e 14 soggetti in trattamento con placebo in uno studio randomizzato, controllato, in doppio cieco, da marzo a luglio. Vit.D e PTH sono stati dosati con metodo Beckman Coulter e DiaSorin rispettivamente, FGF23 con un metodo per ricerca (Kainos Laboratories Inc.). Risultati: Il gruppo in trattamento ha presentato aumento significativo di Vit.D rispetto ai valori basali (p=0,000) e al gruppo placebo (p=0,000); quest'ultimo ha presentato un aumento significativo dei valori rispetto ai basali per l’esposizione solare, ma significativamente inferiore rispetto al gruppo trattato. L'iperparatiroidismo secondario è stato corretto solo nei pazienti trattati (p=0,028); FGF23 è significativamente aumentato nei due gruppi rispetto ai valori basali (p=0,023 placebo; p=0,032 trattamento), ma la differenza tra i gruppi non era statisticamente significativa. Conclusioni: La supplementazione di Vit.D ha determinato una riduzione significativa di PTH (effetto non rilevabile per variazioni legate all'esposizione solare) e un aumento di FGF23, confermando l'effetto di stimolazione della sintesi di FGF23 da parte della Vit.D, sebbene sia noto che FGF23 ne inbisca la sintesi a livello renale. Non è chiarito il valore clinico di delle alterazioni di FGF23, ma lo studio conferma definitivamente la presenza di un feedback positivo. Nell'IC le alterazioni del metabolismo fosfo-calcico, la carenza di Vit.D, l'iperparatiroidismo secondario e le conseguenti variazioni di FGF23 sono da considerarsi dunque un nuovo paradigma di alterazione neuro-ormonale. Unità Operativa Diagnostica Ematochimica, Azienda Ospedaliero-Universitaria di Parma, Parma. 2 Sezione di Chimica Clinica, Dipartimento di Scienze della Vita e della Riproduzione, Azienda OspedalieroUniversitaria di Verona, Verona. Background: It is acknowledged that high values of hemoglobin are a risk factor for thrombosis due to hyperviscosity syndrome, which impairs oxygen delivery to peripheral tissues and worsens vascular occlusion. Little is known, however, if increased hemoglobin values may produce alternative proatherogenic effects through different pathways, such as modulating the concentration of blood lipids. Methods: We performed a search on our LIS for results of hematological and lipid tests on unselected outpatients aged >18 y, referred for routine testing over 6 months. No exclusion criteria were applied for extracting data of low density lipoprotein cholesterol (LDL-C), high density lipoprotein cholesterol (HDL-C), total to HDL-C ratio (COL/ HDL) and atherogenic index of plasma (AIP). Results: Cumulative results were retrieved for 4,874 outpatients (2,150 men). Significantly higher hemoglobin values were found in males than in females (146±14 vs 134±12 g/L; p<0.01). After stratification of study population into quartiles of hemoglobin for both genders, males in the forth quartiles tended to have a much higher COL/HDL ratio (4.0±1.2 vs 3.4±1.0; p<0.01), AIP (-0.05±0.28 vs –0.09±0.28; p<0.01), triglycerides (1.33±0.69 vs 1.21±0.65 mmol/L; p<0.01), LDL-C (3.2±0.9 vs 2.5±0.9 mmol/L; p<0.01), but similar HDL-C (1.4±0.4 vs 1.4±0.4 mmol/L; p=0.36). A similar situation wad found in women in the top versus those in the bottom quartile of hemoglobin, with higher values found for COL/HDL (3.5±1.1 vs ±1.1; p=0.04), AIP (-0.16±0.28 vs –0.19±0.30; p=0.04), triglycerides (1.2±0.6 vs 1.1±0.6 mmol/L; p<0.01), LDL-C (3.3±0.9 vs 2.8±1.0 mmol/L; p<0.01), counterbalanced by lower HDL-C (1.6±0.5 vs 1.7±0.5 mmol/L; p<0.01). The Odds Ratio (OR) for undesirable values were 2.51 (95% CI, 1.9-3.2) for COL/ HDL, 1.3 (95% CI 1.01 to 1.7) for AIP, 1.36 (95% CI 0.99-1.9) for triglycerides, 3.5 (95%CI, 2.6-4. 7) for LDLC and 1.1 (95 CI 0.8-1.5) for HDL-C in women. In men, ORs were 1.51 (95% CI 1.2-1.9) for COL/HDL, 1.3 (95% CI 1.0-1.7) for AIP, 1.5 (95% CI, 1.1-2.1) for triglycerides, 2.4 (95% CI 1.9-3.1) for LDL-C and 0.9 (95 CI 0.6-1.5) for HDL-C. Conclusions: This large epidemiological study on unselected outpatients suggests that high hemoglobin values may be associated with atherosclerotic risk in both genders. biochimica clinica, 2012, vol. 36, n. 6 519 44° Congresso Nazionale SIBioC - Riassunti Poster P099 INSUFFICIENZA RENALE ACUTA IN PAZIENTI SOTTOPOSTI AD INTERVENTI CARDIOCHIRURIGICI: QUALE PREDITTIVITÀ DI NGAL? 1 1 2 2 C. Cosma , M. Zaninotto , A. Bortolami , R. Bianco , D. 1 1 Faggian , M. Plebani 1 U.O.C.Medicina di Laboratorio, Azienda Ospedaliera di Padova- Università degli Studi di Padova 2 Div. di Cardiochirurgia, Azienda Ospedaliera di PadovaUniversità degli Studi di Padova Introduzione: La misura della creatinina, riconosciuta gold standard per la diagnosi di insufficienza renale acuta (IRA), possiede numerose e note limitazioni; c’è quindi l’esigenza di disporre di nuovi biomarcatori che evidenzino precocemente l’insorgenza di IRA. Scopo: Valutare l’efficacia del test uNGAL in relazione allo sviluppo di IRA e le ricadute sull’ approccio clinico in una popolazione consecutiva di pazienti sottoposti ad interventi di cardiochirurgia (CHCARD). Materiali e Metodi: Da gennaio ad agosto 2012, 492 pazienti (347 maschi e 145 femmine, età, range 49-83 anni), sottoposti ad interventi di CHCARD, sono stati monitorati (pre/post intervento e ad intervalli di 12/24 ore per 7 giorni) con la determinazione uNGAL (ArchitectAbbott Diagnostics) e di creatinemia (Cobas C 702, Roche). I risultati sono espressi come medie ± DS. Risultati: I valori di uNGAL e creatinemia nella popolazione maschile sono risultati 105,75±307,9 mg/L (intervallo riferimento [0-120] mg/L) e 115±59,42 μmol/ L (intervallo riferimento [62-115] μmol/L) e in quella femminile 130,59±728.78 mg/L e 86,11±42,82 μmol/L (intervallo riferimento [53-97] μmol/L). Solo il 6,7% della popolazione studiata ha sviluppato IRA post-intervento segnalata da significativi incrementi di uNGAL (da 10 a 50 volte il limite superiore di normalità) che hanno preceduto quelli di creatinina di circa 24 ore. In tali pazienti una significativa diminuzione di uNGAL in 24h (da valori >a 400 mg/L a valori < 120 mg/mL) accompagnata da valori di creatinina costantemente elevati nei giorni successivi (> 250 μmol/L) era predittiva di recupero della funzionalità renale. In alcuni pazienti (n=7), che hanno sviluppato una sindrome da bassa gittata cardiaca (BGC) post-operatoria, si sono riscontrati singoli e sporadici incrementi di uNGAL (>500 mg/L) in concomitanza agli eventi di BGC, con valori di creatinina che sono risultati costantemente nel range di normalità. Conclusioni: I risultati ottenuti, evidenziano nella popolazione di pazienti CHCARD studiata, due informazioni peculiari e di rilevanza clinica fornite dalla determinazione di uNGAL: mancato recupero della funzionalità renale in pazienti con concentrazioni costantemente elevate; incremento in condizioni di BGC che potrebbe mascherare l’insorgenza di IRA. P100 L'IMPATTO DELLA TROPONINA AD ALTA SENSIBILTÀ NELLA GESTIONE DEL PAZIENTE CON SOSPETTA SINDROME CORONARICA ACUTA R. Paravidino, V. Marrè, F. Deiana, S. Massaro, P. Iandolo , R. Tronci, P. Botto, C. Ottaviano, G. Devoto Laboratorio Analisi Centrale, ASL4 - Chiavarese Ospedale Lavagna Scopo: Revisionare il protocollo diagnostico delle Sindromi Coronariche Acute (SCA) dopo 12 mesi dall’introduzione in routine della Troponina Hs con tre obbiettivi: valutare le performance diagnostiche del test, rivedere il protocollo diagnostico, in particolare la possibilità di eliminare il terzo controllo alle 12 ore, riduzione del numero di ore trascorse dai pazienti nel Dipartimento di Emergenza (DEA). Materiali e metodi: Sono stati arruolati 3312 Pazienti afferenti al DEA. Sono state diagnosticate 336 SCA. Nei restanti 2976 pazienti sono risultati negativi gli accertamenti diagnostici per cardiopatia ischemica acuta. Le concentrazioni di Troponina Hs sono state determinate con il sistema Modular Analytics E170, con valore di cut-off pari a 0.014 ng/mL (99° Percentile). Come Gold Standard sono state utilizzate le diagnosi di dimissione dai reparti di degenza. Sono stati calcolati la sensibilità, la specificità, il valore predittivo positivo (VPP), il valore predittivo negativo (VPN). Risultati: 32 falsi negativi al primo prelievo: 8 SCA (5 pazienti con TnT positiva al secondo prelievo, 3 pazienti con TnT sempre negativa nei controlli al ricovero), 24 IMA (15 pazienti 1 solo prelievo pre ricovero, tutti positivi al secondo controllo in reparto; 9 pazienti con TnT positivi al secondo prelievo). 861 i falsi positivi. Le perfomance del test sono risultate: sensibilità 91%, specificità 72%, VPP 30%, VPN 98%. Il livello decisionale di 0.017 ng/mL, ottenuto tramite l’analisi ROC, discrimina tra la popolazione afferente al DEA per altre cause e soggetti con SCA e IMA con un VPP 29.5% e VPN 97.8%. Delta percentuale, utile nell’interpretazione delle variazioni delle concentrazioni della troponina nei prelievi seriati, è risultato essere non inferiore al 100%; tutti i pazienti IMA + SCA avevano delta superiori a tale livello. Delta temporale: tutti i pazienti IMA + SCA positivi al secondo prelievo eseguito entro 6 ore dal prelievo basale. Discussione e conclusioni: Si propone la modifica del protocollo diagnostico delle SCA che prevede l’esecuzione di un prelievo basale e di un secondo prelievo entro 6 ore, con un risparmio di circa 1500 ore annue di permanenza dei pazienti presso il DEA con indubbi vantaggi nella gestione del reparto. biochimica clinica, 2012, vol. 36, n. 6 521 44° Congresso Nazionale SIBioC - Riassunti Poster P101 MR-ProADM AND LIPOPROTEIN(a) IN HYPERTENSIVE PATIENTS 2 2 2 1 P. Cardelli , G. Ferranti , G. Salerno , M.T. Corsetti , R. 1 2 1 1 Di Costanzo , A. Costante , R. Amodeo , V. Soldati , E. 1 2 1 2 Scaramucci , A. Tammeo , V. Polidori , L. De Biase 1 Central Laboratory, S. Andrea Hospital of Rome II Faculty of Medicine and Psychology ‘’Sapienza’’, Rome 2 Aim: The present study was performed to evaluate the serum levels of midregional proadrenomedullin (MRproADM), lipoprotein(a) (Lp(a)), apolipoprotein A (apoA1) and apolipoprotein B (apo - B1) in patients with hypertension. Methods: The study included 16 patients with esseltial hypertension and 15 control subjects. 87% of patients were smokers or ex-smokers while 25% of patients were diabetics. Blood samples were withdrawn at time 0 (before starting therapy) centrifuged and all the serum samples were stored at -80 °C until use. Lp(a) was measured by nephelometric immunoassay (Siemens BNII), MRproADM was measured by a Time-Resolved Amplified Cryptate Emission (TRACE, kit Brahms Kryptor) and apoA1 and apo-B were measured by kits Vitros Fusion 5.1 (Johnson & Johnson). The results were analyzed using the Kruskal-Wallis, Mann-Whitney, multiple regression and Pearson correlation (p values ≤ 0.05 were considered statistically significant). Results: In patients with hypertension MR-proADM and Lp(a) serum levels were significantly (p<0.0001) higher compared to the control group, while no modification of apo-A1 or apo-B1 serum concentration were observed between the groups. In multiple regression analysis with Mr-ProADM as the dependent variable, Lp(a) was a significant contributor to the regression (coefficient=0.019, t=9.82 and p<0.0001). Mr-ProADM levels increased in accord to quartiles of Lp(a) (p=0.02). The correlation between MR-proADM and Lp(a) in hypertension patients was r=0.95, p<0.0001. Conclusion: The present study suggest that Mr-ProADM and Lp(a) could be utilized for the assessment of the risk of vascular or cardivascular complications in patients with hypertention. Al-Omari MA, Khaleghi M, Mosley TH Jr, et al. Midregional pro-adrenomedullin is associated with pulse pressure, left ventricular mass, and albuminuria in African Americans with hypertension. Am J Hypertens 2009;22:860-6. 522 biochimica clinica, 2012, vol. 36, n. 6 P102 N- TERMINAL FRAGMENT OF BRAIN NATRIURETIC PEPTIDE PREDICTS VASCULAR HEALTH AND SUBCLINICAL ATHEROSCLEROSIS IN HYPERTENSIVE: RESULTS FROM MEHLP STUDY 1 2 2 M. Franzini , L.E. Pastormerlo , C. Prontera , E. 2 2 2 2 Giannelli , M. Maltinti , P. Di Cecco , S. Masotti , A.M. 2 2 2 2 Mazzone , S. Maffei , C.L. Susini , D. Chiappino , A. 2 Clerico 1 Scuola Superiore Sant'Anna, Pisa Fondazione Toscana G. Monasterio, Pisa 2 Background: Brain natriuretic peptide (BNP) expression in arterial vessels increase with the evolution of atherosclerosis, thus plasma assay of BNP N-terminal fragment (NT-proBNP) might reflect the vascular pathophysiology. The MEHLP is a population study aimed to evaluate the amount of cardiovascular subclinical pathology in an asymptomatic general population selected from the community of Montignoso (Ms), Italy. Methods: The population (1474 people, m±SD: 61±14 years, males 48%, left ventricular ejection fraction 58±5%, 2 cardiac mass index 118±42mg/m ) was screened with biohumoral evaluation comprehensive of the N-terminal fragment of brain natriuretic peptide (NT-proBNP), coronary calcium score (CCS) assessed by thoracic computed tomography, intima media thickness (IMT) of common carotid artery and ascending aorta dilatation (AAD; 850subjects) assessed by echography. Results: Diabetes, hypertension and hypercholesterolemia were present in 11%, 41% and 38% of subjects, respectively; 13% were actual smokers, 31% past smokers. Median NT-proBNP was 59 ng/L (IQ range 33-101). CCS, IMT and AAD were, respectively, 156±521 U.A., 0.8±0.3 mm and 32±4 mm, with 11%, 25% and 4% of people showing CCS, IMT and AAD respectively higher than 400 U.A., 75° percentile, and 40 mm. CCS >400 U.A., IMT >75° percentile and AAD >40 mm were all predicted at ROC analysis by plasma NT-proBNP levels (AUCs 0.589, 0.591, 0.564, respectively, p<0.05 for all). NTproBNP was higher in patients with a) CCS>400 U.A. (64, 42-128 vs. 57, 32-98 ng/L, p<0.01), b) IMT>75° percentile (72, 38-139 vs. 58, 32-95, p<0.01), c) AAD >40 mm (65, 36-171 vs. 59, 33-99, p=0.05), despite no differences in left ventricular ejection fraction, nor in cardiac mass; this findings were confirmed in the subset of hypertensives, while not in subject with diabetes, hypercholesterolemia, or with past/present smoking habit. Conclusions: NT-proBNP level, within the upper normal range, predicts subclinical coronary atherosclerosis and vascular health, namely in asymptomatic hypertensive subjects, with no relation with heart structural and functional involvement, possibly reflecting a vascular source of production and secretion. Emdin M, Fontana M, Poletti R, et al. Natriuretic peptide testing in primary care patients. Clin Chem Lab Med 2008;46:1533-42. 44° Congresso Nazionale SIBioC - Riassunti Poster P105 THE COMBINED USE OF NEUTROPHIL GELATINASE-ASSOCIATED LIPOCALIN AND BRAIN NATRIURETIC PEPTIDE IMPROVES RISK STRATIFICATION IN PEDIATRIC CARDIAC SURGERY P106 TROPONINA CARDIACA I AD ALTA SENSIBILITA' E ORARIO DI PRELIEVO IN CORSO DI INFARTO ACUTO DEL MIOCARDIO 1 1 2 3 G. Bonetti , E. Agazzi , A. Affatato , L. Caimi 1 1 2 S. Storti , M. Cantinotti , V. Lorenzoni , M. Del 1 1 1 1 Fiandra , D. Chicchi , M.S. Parri , A. Romanelli , F. 1 3 Della Pina , A. Clerico 1 Fondazione Toscana G. Monasterio, Massa, Italy CNR Institute of Clinical Physiology, Pisa, Italy 3 Scuola Superiore Sant’Anna, Pisa, Italy 1 U.O. Lab. Analisi Chimico Cliniche, Spedali Civili di Brescia 2 U.O. Cardiologia, UTIC, Spedali Civili di Brescia 3 Dip. Scienze Biomediche e Biotecnologie, Università degli Studi di Brescia 2 Background: Acute kidney injury (AKI) is a common and severe complication in children undergoing cardiac surgery for congenital heart disease (CHD). Diagnosis of AKI in this clinical setting is at the present inadequate, based on serial serum creatinine measurements, with some limitations leading to a delay in diagnosis and a failure in identifying sub-clinical damage. Clinical relevance of brain natriuretic peptide (BNP) in pediatric cardiac surgery has been acknowledged in the last years, although extensive studies are still lacking. We test the hypothesis whether the combined use of a cardiospecific biomarker (BNP) and a early marker of renal failure (urinary neutrophil gelatinase-associated lipocalin - uNGAL), may improve both risk stratification and diagnostic accuracy of AKI in pediatric cardiac surgery. Methods: We prospectively enrolled 135 children [median age 7 (interquartile range 1–49) months] undergoing cardiac surgery for CHD. Biomarkers were evaluated pre and post operatively at different times after cardiopulmonary-bypass (CPB): uNGAL at 2, 6 and 12 hours (h); BNP at 12 and 36 h; serum creatinine at 2, 6, 12, and 36 h. Development of AKI has been defined as 1.5 serum creatinine increase. Results: AKI occurred in 39% of patients (65% neonates and 32% older children, p=0.004). Peak of uNGAL values occurred more frequently at 2-h. uNGAL values at 2-h [median 28.2 (interquartile range 7.0–124.6) ng/L] had a good diagnostic accuracy for early diagnosis of AKI with an AUC (area under the curve) ROC (receiver operating characteristic) curve of 0.85 (SE 0.034). In a multivariable logistic regression analysis development of AKI was significantly associated with uNGAL values at 2 h after CPB [OR=1.88 (1.30–2.72, p=0.001)], together with CBP time and Aristotle score (index of complexity of the surgical procedure), while pre-operative BNP values were not. uNGAL and pre-operative BNP values (together with Aristotele score) were significantly associated with adverse outcome (longer intubation time and mortality). Conclusions: Pre-operative BNP and uNGAL values after CPB (together with Aristotle score) were independently associated with a more severe course and worse outcome in children undergoing cardiac surgery for congenital heart disease. 524 biochimica clinica, 2012, vol. 36, n. 6 Per la diagnosi di necrosi miocardica il gold standard biochimico è rappresentato dalla troponina cardiaca (cTn), tradizionalmente impiegata in protocollo con prelievi seriati: all’ammissione in ospedale(H), dopo 4-6 e 12h. Nella 3a Definizione Universale dell’Infarto miocardico (IMA) (3IM) 2012 viene indicato, con i nuovi metodi di determinazione di cTn ad alta sensibilità, un protocollo con 2 prelievi: basale e dopo 3-6h, ed eventuali prelievi più tardivi in caso di ulteriori episodi ischemici; si indica inoltre che nell'IMA il rilascio del marcatore dovrebbe avere un tipico rilascio con incremento e/ o riduzione con almeno 1 valore superiore al livello decisionale (LD) per necrosi miocardica. Scopo: Valutare la cinetica di rilascio della cTnI in rapporto all’orario di insorgenza dei sintomi in un gruppo di pazienti (pz) con IMA impiegando un metodo ad alta sensibilità. Materiali e metodi: In 79 pz con diagnosi di IMA (16F, 63M, età media 68a, range: 36-88a) la cTnI è determinata con metodo LOCI su sistema Dimension Vista (LD:0.045 μg/L, CV≤10% a 99°perc.) su campioni di plasma LiHep, all’ammissione, dopo 6 e 12h. cTnI è definita positiva (+) se ≥LD mentre la cinetica di rilascio "tipica" quando la differenza (D) tra la concentrazione di cTnI di campioni successivi è superiore alla D critica derivata dalla variabilità biologica, con aumento ≥46% o riduzione ≥32%. Risultati: Nel gruppo (Gr) di 53 pz con insorgenza sintomi ≤6h (GrA), cTnI+ a T0: n=38 (72%), cTnI+ a T6: n=15 (28%), di cui 9 con insorgenza ≤2h, 4 a 2-3h e 2 a 4h. Nel GrA la cinetica è stata "tipica" in 46 pz (86.8%). Nel GrB di 26 pz con insorgenza dei sintomi >6h, cTnI+ a T0: n=24 (92%), cTnI+ a T6: n=2 (8%), con insorgenza dei sintomi a 48 e 72h. Nel GrB la cinetica si è mostrata "tipica" in 11 pz (42.3%). Discussione e conclusioni: Nei pz studiati si evidenzia come nel 78.5% dei casi la cTnI sia già + all’ammissione mentre nel 21.5% lo sia a 6h. Il presente studio conferma quanto indicato nel documento 3IM in cui si consiglia l’impiego di un prelievo basale ed un successivo dopo 3-6h, anche se, in base ai dati riscontrati, utili potrebbero essere 3 prelievi consecutivi: all’ammissione,dopo 3 e 6h, in quanto il solo prelievo dopo 3h potrebbe non essere sufficiente in caso di ammissione precoce del pz in H. 44° Congresso Nazionale SIBioC - Riassunti Poster P107 TROPONINA DI ULTIMA GENERAZIONE: QUALI RICADUTE SULLA GESTIONE DEL PAZIENTE CON DOLORE TORACICO IN PRONTO SOCCORSO? P108 TROPONINE CARDIACHE A CONFRONTO IN UNA POPOLAZIONE DI SOGGETTI ANZIANI 1 1 1 1 2 M.M. Mion , G. Bragato , M. Zaninotto , G. Vettore , F. 2 3 3 1 Tosato , L. Babuin , S. Iliceto , M. Plebani 1 1 2 M.M. Mion , G. Bragato , M. Zaninotto , A. Rossi , V. 2 1 Giantin , M. Plebani 1 1 U.O.C. Medicina di Laboratorio, Az. Osp. – Univ. di Padova, Padova 2 Dip. di Pronto Soccorso, Az. Osp. – Univ. di Padova, Padova 3 Dip. di Scienze Cardiologiche, Toraciche e Vascolari, Az. Osp. – Univ. di Padova, Padova Scopo di questo studio è stato verificare l’impatto dell’introduzione di un nuovo metodo di misura della troponina cardiaca I (TnI) di ultima generazione, in sostituzione al precedente (rispettivamente: DimensionVista=TnI-V; Dimension-RxL=TnI-R; μg/L; Siemens), sulla gestione del paziente (pz) in Pronto Soccorso (PS) e sul corrispondente tasso di ricovero ospedaliero. Da settembre 2010 (introduzione di TnI-V in routine) a gennaio 2011, è stata richiesta la determinazione di TnI-V per 3886 pz in PS. Da uno studio precedente, risulta che il range di concentrazioni TnI-V=0.046-0.400 corrisponde al range TnI-R=0.00-0.15 (cutoff per danno miocardico: TnI-V=0.045, TnI-R=0.15). In 839 pz (gruppo A, 21.6%) (M=440, F=399, range di età=22-102 anni), TnI-V è risultata nel range 0.046-0.400 in PS e/o durante il ricovero in reparto mentre in 609 pz (gruppo B, 15.7%), TnI-V era compresa nel range 0.046-0.400 già in PS. Diagnosi principale alla dimissione (gruppo A): infarto miocardico acuto (IMA) (69, 8.2%), patologie (P) cardiache non-IMA (314, 37.4%), dolore toracico di origine non cardiaca (42, 5.0%), P pneumologiche (159, 18.9%), P gastroenteriche (52, 6.2%), P neurologiche (48, 5.7%), P nefrologiche (30, 3.6%), infezioni-sepsi (30, 3.6%), P oncologiche (25, 3.0%), P metaboliche (20, 2.4%), sincope (15, 1.8%), P ortopediche (11, 1.3%), P psichiatriche (4, 0.5%), P ginecologiche (1, 0.1%), altra diagnosi (19, 2.3%). Per i pz del gruppo B, sono state riviste le schede di accesso al PS da un pool di medici esperti, all’oscuro del dato della TnI-V: per 581 pz (95.4%) è stata riconfermata la necessità del ricovero ospedaliero; per 28 pz (4.6%) il ricovero è stato indotto dal solo incremento della TnI-V (>0.045). L’introduzione in routine di un metodo per la TnI di ultima generazione, ha consentito di identificare una maggiore percentuale di pz con valori positivi di TnI (>cutoff) in PS mentre la % di ricovero ospedaliero determinato esclusivamente dal dato biochimico non è aumentata significativamente (4.6%). In particolare, 69 pz del gruppo A (8,2%) sono stati dimessi con una diagnosi di IMA (TnI-V>cutoff, TnI-R<cutoff) anziché di Angina Instabile in base ai valori di TnI-V, confermando la maggiore sensibilità nell’individuazione di danno miocardico del nuovo metodo. U.O.C. Medicina di Laboratorio, Az. Osp. – Univ. di Padova, Padova 2 Clinica Geriatrica, Az. Osp. – Univ. di Padova, Padova Lo studio ha valutato le prestazioni cliniche di 2 metodi di ultima generazione per la misura delle troponine cardiache (Tn) e di 1 metodo di generazione precedente (rispettivamente: Dimension-Vista=TnI-V, Siemens; Modular E170=hsTnT, Roche; DimensionRxL=TnI-R, Siemens; μg/L), in una popolazione di soggetti anziani. Da marzo ad ottobre 2011 sono stati arruolati 384 pazienti (pz) presso la Clinica Geriatrica. GRUPPO 1 (GR1): 30 pz afferenti agli ambulatori (6M+24F; età=69-92 aa); GRUPPO 2 (GR2): 354 pz ricoverati presso la Clinica Geriatrica (114M+240F; età 64-105 aa). Cutoff per danno miocardico: TnI-V=0.045, hsTnT=0.014, TnIR=0.15. Nei pz del GR1 è stato effettuato 1 solo prelievo, mentre nei pz del GR2 sono stati effettuati ≥ 2 prelievi seriali. I pz del GR2 sono stati classificati in base a: A) TnI-V (NEG: ≤0.045 in tutti i prelievi; POS: >0.045 in almeno 1 prelievo); B) diagnosi di dimissione principale (DDP). Studio di comparazione: range di concentrazione di TnI-V, hsTnT, TnI-R misurati in 235 campioni dei pz del GR2, rispettivamente: 0.046-0.437, 0.010-0.550, 0.00-0.88. GR1: TnI-V è risultata <0.045 nel 100% dei pz. GR2: 242 pz (68%) sono risultati NEG mentre 112 pz (32%) POS. DDP nei pz del GR2, n (%; POS): Sindrome Coronarica Acuta SCA 9 (2.5%; 9); Scompenso Cardiaco 46 (13%; 15); Patologia (P) Pneumologica PP 64 (18%; 17); P-Gastroenterica 55 (15.5%; 15); P-Neurologica 60 (17%; 18); P-Nefrologica 35 (10%; 18); P-Metabolica 6 (2%; 3); Anemizzazione 19 (5%; 3); Altro 60 (17%; 14). Nel GR2, 28 pz (7.9%) sono deceduti durante il ricovero: 12 (43%) POS, 16 (57%) NEG. Nello studio di comparazione, 32 (14%) e 232 (99%) campioni sono risultati >cutoff utilizzando rispettivamente TnI-R e hsTnT. In particolare, nei pz con SCA, TnI-R e hsTnT sono risultate >cutoff rispettivamente nel 29% e nel 100% dei campioni analizzati. TnI-V è risultata <cutoff nel 100% dei pz del GR1, confermandone l’attesa specificità. GR2: DDP più frequente=PP (18%). L’aumentata % di TnI-V e hsTnT >cutoff nei pz con SCA (100%), ne evidenzia la maggiore sensibilità vs TnI-R nella diagnosi precoce di danno miocardico. I decessi, risultati più frequenti nei pz con valori di TnI-V>cutoff (11% vs 7%), confermano l’attesa utilità prognostica della nuova metodica di analisi. biochimica clinica, 2012, vol. 36, n. 6 525 44° Congresso Nazionale SIBioC - Riassunti Poster P109 “TRIAGE CARDIO PANEL”: PRESTAZIONI ANALITICHE E CLINICHE DI UN NUOVO PANNELLO DI BIOMARCATORI SU STRUMENTAZIONE POINT OF CARE P110 24S-HYDROXYCHOLESTEROL IN PLASMA: A MARKER OF CHOLESTEROL TURNOVER IN NEURODEGENERATIVE DISEASES V. Leoni , C. Caccia 1 1 1 1 M.M. Mion , G. Bragato , A. Karydi , M. Zaninotto , L.M. 2 1 Biasucci , M. Plebani 1 U.O.C. Medicina di Laboratorio, Az. Osp. – Univ. di Padova, Padova 2 Istituto di Cardiologia, Università Cattolica del Sacro Cuore, Roma L’esigenza di disporre dell’informazione di laboratorio in tempo utile per la gestione del paziente critico, rende necessario il ricorso alle analisi decentrate (Point of care Testing, POCT) presso presidi sanitari distanti dal Laboratorio di Analisi. E’ stato valutato il nuovo pannello biochimico "Triage Cardio 2 Panel": 2 immunodosaggi in fluorescenza per la determinazione della troponina cardiaca I (TnI-T) e del peptide natriuretico di tipo B (BNP), su analizzatore Triage MeterPro (Alere San Diego Inc.). Le prestazioni sono state confrontate con quelle dei metodi per la determinazione del frammento N-terminale del pro-ormone del BNP (NT-proBNP, Dimension ExL), della troponina cardiaca I (TnI-E, Dimension ExL; TnIA, ADVIA Centaur) (Siemens Health Care Diagnostics), della troponina cardiaca T (generazione precedente e ultima: TnT e hs-TnT) (Roche Diagnostics). Studio dell’imprecisione: 44 determinazioni di TnI-T e BNP in un pool di plasma (EDTA) con 2 diversi lotti di reattivo per 22 giorni. Studio clinico: la concentrazione dei biomarcatori è stata determinata nel campione (plasma EDTA) di 68 pazienti non consecutivi (45M+23F; età: mediana, range: 70, 46-94 anni) all’ammissione in pronto soccorso (PS) per dolore toracico. Livello decisionale per danno miocardico: TnI-T=0.02 μg/L, TnI-E=0.045 μg/ L, TnI-A= 0.040 μg/L, TnT=0.03 μg/L, hs-TnT=14 ng/L; livello decisionale per scompenso cardiaco: BNP=100 ng/L; NT-proBNP=450 e 900 ng/L (≤50 anni e >50 anni, rispettivamente). Studio dell’imprecisione: media (CV%) TnI-T=0.02 μg/L (20.00%); BNP=114 ng/L (9.33%). Diagnosi principale alla dimissione: sindrome coronarica acuta 48 (SCA: infarto miocardico acuto 39; angina instabile 9); patologia cardiaca non-SCA 16; altra diagnosi 4. Pazienti con concentrazioni di biomarcatore > livello decisionale, n (%): TnI-T 47 (69%), TnI-E 48 (71%), TnI-A 50 (74%), TnT 42 (62%), hs-TnT 55 (81%); BNP 30 (44%); NT-proBNP 35 (51%). Le caratteristiche di imprecisione sono apparse soddisfacenti. Le prestazioni cliniche sono risultate accurate e in linea con quelle dei metodi in uso di routine nel laboratorio centralizzato, anche quando di ultima generazione e ad elevata sensibilità, suggerendo un impiego affidabile del POCT valutato nella diagnostica di laboratorio decentrata. 526 biochimica clinica, 2012, vol. 36, n. 6 Laboratorio di Patologia Clinica e Genetica Medica, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milano Brain cholesterol is mainly involved in cell membrane structure and in signal transduction, neurotransmitter release, synaptogenesis and membrane trafficking. Impairment of brain cholesterol metabolism was described in neurodegenerative diseases, such as Alzheimer, Huntington Diseases and Multiple Sclerosis. Since the blood-brain barrier efficiently prevents cholesterol uptake from the circulation into the brain, de novo synthesis is responsible for almost all cholesterol present there. Cholesterol is converted into 24S-hydroxycholesterol (24OHC) by cholesterol 24-hydroxylase (CYP46A1) expressed in neural cells. Plasma levels of 24OHC depend upon the balance between cerebral production and hepatic elimination and are related to the number of metabolically active neurons in the brain. Factors affecting brain cholesterol turnover and liver elimination of oxysterols were found to significantly affect its plasma levels, together with the metabolism of plasma lipoproteins, genetic background, nutrition and lifestyle habits. Either increased or decreased plasma 24OHC was described in patients with neurodegenerative diseases. A group of evidence suggest relating reduced levels to the loss of metabolically active cells and the degree of brain atrophy. Other processes, however, such as inflammation, dysfunction of BBB, increased cholesterol turnover might counteract this tendency resulting into increased levels or in not significant changes. The study of plasma 24OHC is likely to offer an insight about brain cholesterol turnover with a limited diagnostic power. Leoni V, Caccia C. Oxysterols as biomarkers in neurodegenerative diseases. Chem Phys Lipids 2011;164:515-24. 44° Congresso Nazionale SIBioC - Riassunti Poster P111 ACCURATEZZA DELLA DIAGNOSI DI SEPSI NEI PAZIENTI AFFERENTI AL PRONTO SOCCORSO: RIVALUTAZIONE DEGLI INTERVALLI DI RIFERIMENTO DELLA PROCALCITONINA 1 2 1 1 G. Grandi , G. Giannazzo , A. Caldini , M. Brogi , T. 1 1 2 1 Biagioli , A. Terreni , B. Casanova , V. Ercoli , A. 1 1 Moscarella , G. Messeri 1 Laboratorio Generale, Dipartimento Diagnostica di Laboratorio, Azienda Ospedaliero Universitaria Careggi, Firenze 2 Pronto Soccorso Medico Chirurgico e Osservazione Breve, DEA, Azienda Ospedaliero Universitaria Careggi, Firenze La diagnosi di sepsi nei pazienti afferenti al PS deve essere effettuata con elevata accuratezza e tempestività. Scopo del lavoro è stato quello di rivalutare, il cutoff della Procalcitonina (PCT; eseguita h24 con test Vidas Brahms PCT, Biomerieux) attualmente fissato a 0.5 ng/mL, mediante analisi retrospettiva nei pazienti afferenti al PS con diagnosi di ingresso di sospetta sepsi/ infezione grave dal 1° gennaio 2011 al 31 maggio 2011. Per ogni paziente sono stati esaminati i dati relativi a PCT, emocromo, e eventuale emocoltura, diagnosi di entrata e di uscita dal PS e eventuale ricovero. Sono stati arruolati 1628 pazienti, di cui 828 (51%) di sesso femminile e 800 di sesso maschile (49%), di età media pari a 69 anni (range: 8-110 anni). Dividendo la popolazione in tre gruppi (PCT, ng/mL <0,05; 0,05-0,49; ≥ 0,5) si nota che, all’aumentare della PCT, aumenta la percentuale di ricoveri (44,07%;73,84%;85,31%) e quella di diagnosi in uscita di sepsi (1,44%; 12,74%; 31,52%). Inoltre, sia il numero di leucociti che la percentuale di granulociti neutrofili, sono risultati significativamente aumentati nel II e nel III gruppo (t-test, p<0.00001). Il numero di emocolture positive risulta più alto nel II e III gruppo (7;54;57), mentre la percentuale diminuisce (78%; 73%; 43%), dato probabilmente attribuibile a terapie antibiotiche pregresse all’accesso al PS. Per la rivalutazione del cut-off è stata utilizzata la ROC curve dividendo i pazienti in base alla diagnosi di sepsi in uscita dal PS. Al cut-off attuale, 0.5 ng/mL, la sensibilità è risultata 61%, la specificità 80% e l’accuratezza 77%, mentre utilizzando un cut-off di 0.25 ng/mL è stata ottenuta una sensibilità del 77%, una specificità del 72% e un’accuratezza del 72% (AUC= 0.814; p<0.0001). Utilizzando il cut-off di 0.25 ng/mL si ottiene un significativo aumento di sensibilità (14%) a discapito di solo il 5% di accuratezza. Dal momento che per i pazienti in ingresso al PS è molto importante una elevata sensibilità diagnostica e sulla base dei risultati ottenuti, il cut-off è stata abbassato a 0,25 ng/ml, soglia peraltro utilizzata anche nello studio RCT PROHOSP. Schuetz P, Christ-Crain M, Thomann R, et al. The ProHOSP Randomized Controlled Trial. JAMA 2009;302:1059-66. P112 C’È UN TEMPO PER L’URGENZA? C. Perani , G. Tiraboschi, B. Saladino, A. Panna, L. Auriemma Medicina di Laboratorio, Azienda Ospedaliera Bolognini di Seriate Obiettivo è stato quello di analizzare la tempistica di gestione degli esami richiesti in urgenza-emergenza. Sono state valutate le richieste urgenti pervenute al Laboratorio di Seriate-Azienda Ospedaliera Bolognini nel primo trimestre 2012, analizzando sia il TAT di Laboratorio (tempo tra la ricezione del materiale biologico e la comunicazione del risultato, prefissato in massimo 60 min) che il TAT clinico (tempo tra la formulazione della richiesta e la disponibilità del dato, auspicato in max. 80 min) di ogni Unità Operativa (U.O.) richiedente dell’Ospedale di Seriate. Il Laboratorio di urgenza, aperto 24/24 ore con guardia attiva tecnica, è integrato nel Laboratorio centrale; il trasporto del materiale biologico è gestito dalle Unità richiedenti e la distanza si percorre mediamente in 5 min; l’U.O. accetta e riceve le risposte per via informatica. Di ogni richiesta è stato rilevato l’orario di accettazione degli esami, di check-in in laboratorio e di rilascio delle risposte. Da 21 U.O. sono pervenute 14.061 richieste in urgenza (30% dalle ore 7 alle 8.30, 35% dalle ore 8.30 alle 14, 35% dalle ore 14 alle 7). Risulta che il 98.4% rientra nei 60 min del TAT di laboratorio (media 30 min), 1.4% tra i 60 e i 70 min per ricontrollo di dati patologici e/o per non conformità preanalitiche, 0.1% tra 70-90 min per ritardata coagulazione delle provette di siero per proteina C reattiva e proteine totali e 0.1% per blocchi strumentali. Il tempo tra la prescrizione degli esami e l’arrivo in Laboratorio del materiale biologico va da un minimo di 1 min alle 5 ore, con un tempo medio per tutte le U.O. di 31 min; il TAT clinico si mantiene per il 76% negli 80 min, per il 4% tra 80-90 min e per il 20% oltre i 90 min. Sheppard C, Franks N, Nolte F, et al. Improving quality of patient care in an emergency department: a laboratory perspective. Am J Clin Pathol 2008;130:573-7. biochimica clinica, 2012, vol. 36, n. 6 527 44° Congresso Nazionale SIBioC - Riassunti Poster P117 INFEZIONI DA MICETI DEL GENERE CANDIDA IN PAZIENTI OSPEDALIZZATI NEL BIENNIO 2009-2011 V. Cortese, L. De Cristofano, A. Pesce, P. Rotondo, A. Monteforte, C. Maisto, M.R. Righetti, R. Miceli, M.T. Polistina Lab. Patologia Clinica P.O. San Giovanni Bosco Introduzione: La Candida è un micete saprofita, che si può presentare o come un abituale commensale dell’uomo o come patogeno. Essendo un microbo “endogeno” le infezioni da Candida vengono definite opportunistiche, poiché tendono a comparire quando si verifica alterazione dell’immunocompetenza dell’ospite, infatti la candidosi,dopo la pneumocistosi, è la più frequente malattia opportunistica in pazienti affetti da AIDS. Materiali e metodi: Nel sospetto della presenza di lieviti le colonie, bianche perlacee, cresciute dopo 24–48 h a 37°C su Agar Sabouraud, sono state identificate con il sistema Vitek 2 della Bio-Merieux. L’antimicogramma, invece, è stato effettuato con tre tecniche, che davano per ogni antimicotico testato le corrispondenti MIC: sistema di sensibilità Sensitrite YeastOne, E-test su agar MuellerHinton e card Vitek2. Il test di sensibilità Sensitrite è un test di microdiluizione colorimetrica. Ogni piastra contiene 96 pozzetti con concentrazioni scalari di antimicotico e un indicatore colorimetrico. Dopo 24-48 ore d’incubazione il viraggio dell’indicatore dal blu al rosso indica la crescita micotica all’interno del pozzetto. Conoscendo il Break Point di ogni singolo antimicotico, il rapporto tra MIC e B.P. indica l’efficacia del farmaco. L’E-Test è un test di diffusione su agar. Si allestisce mettendo su Agar Mueller Hinton una striscia di carta bibula rettangolare, contenente concentrazioni scalari dell'antimicotico di cui si vuole saggiare l'attività. Risultati: Nel biennio 09/11nel nostro ospedale sono stati isolati 82 ceppi di miceti appartenenti al genere Candida. Dai risultati ottenuti, concordemente con altri autori, si evidenzia che la maggior parte delle candidosi si riscontrano nei reparti di terapia intensiva dove sono presenti pazienti immunocompromessi,inoltre si osserva, che nella maggior parte dei casi C.albicans, C.sake, C.dubliniensis e C.norvegensis risultano sensibili agli antimicotici testati, mentre i restanti ceppi hanno acquisito delle resistenze. Conclusioni: I miceti del genere Candida, un tempo sottovalutati per il loro saprofitismo naturale, diventano oggi sempre più causa di complicanze nella degenza ospedaliera, principalmente per due motivi:bassa immunocompetenza dei ricoverati ed elevata tossicità dei farmaci antimicotici. 530 biochimica clinica, 2012, vol. 36, n. 6 P118 INTRODUZIONE DEL TSH FRA GLI ESAMI RICHIEDIBILI DAL PRONTO SOCCORSO: VALUTAZIONE DELLA APPROPRIATEZZA DELLA RICHIESTA 1 1 2 1 A. Giacomini , H. Afshar , D. Foresti , M. Miolo , C. 1 2 1 3 Bacelle , M. Chiesa , P. Carraro , M. Plebani 1 Dip. Medicina di Laboratorio, Lab. Analisi Osp. Sant’Antonio, Padova 2 Pronto Soccorso, Osp. Sant’Antonio, Padova 3 Dip. Medicina di Laboratorio, Azienda Ospedaliera Università di Padova Introduzione e scopo: Abbiamo valutato, in collaborazione con il Pronto Soccorso (PS) dell’Ospedale S.Antonio, l’utilizzo del TSH, test introdotto fra gli esami richiedibili dal Pronto Soccorso (PS) degli ospedali afferenti al Dipartimento Interaziendale Medicina di Laboratorio di Padova. Materiali e metodi: Nel periodo marzo-agosto 2012 sono pervenute dal PS 240 richieste di TSH, riferite nel 25% dei casi a patologie tiroidee anamnestiche. Il TSH è stato determinato con metodo LOCI su strumentazione Dimension EXL (Siemens Healthcare Diagnostics). I livelli decisionali adottati sono stati: TSH>4mU/L per ipotiroidismo, TSH<0.2 mU/L per ipertiroidismo. Per ciascuna richiesta, in base al verbale di PS, sono state valutate: congruità secondo le linee guida adottate dal Dipartimento, efficacia organizzativa e clinica valutate in base ad indicatori di qualità previamente concordati. Risultati: Le richieste di TSH hanno riguardato l’1.7% degli accessi al PS. Il motivo principale di richiesta è stato fibrillazione/flutter atriale (73 casi), seguito da patologia tiroidea nota (56 casi). Il TSH è risultato >4 mU/L in 22 casi (9.2% del campione) e <0.2 mU/L in 5 casi (2.0%). La richiesta del TSH è risultata congrua nel 75.8% dei casi. Il test ha favorito la dimissione sicura del paziente in 134 casi (55.8%), ha contribuito a determinare il ricovero in 15 casi (6.3%), non ha modificato l’atteggiamento del clinico in 91 casi (37.9 %). Il test ha contribuito ad individuare un percorso diagnostico idoneo in 161 casi (67.1%), un percorso terapeutico idoneo in 136 casi (56.7%) e ha determinato il percorso diagnostico e terapeutico in 9 casi (3.8%): 8 aggiustamenti di terapia ed una nuova diagnosi. Discussione e conclusioni: Il TSH si è dimostrato efficace nell’escludere una patologia tiroidea in soggetti afferenti al P.S. per turbe del ritmo e nel rilevare la necessità di aggiustamenti di terapia in presenza di patologia tiroidea; tuttavia il livello di appropriatezza della richiesta di tale test può essere migliorato, incrementandone l’efficacia, ed inoltre una valutazione costi/benefici è necessaria per confermare questa implementazione. Carraro P. Esami di laboratorio raccomandati in alcune tipiche situazioni di Pronto Soccorso. Biochim Clin 2011;35:207-28. 44° Congresso Nazionale SIBioC - Riassunti Poster P119 L’ESAME AUTOMATIZZATO DELLE URINE: APPROCCIO BOTTOM-UP NELLA DIAGNOSI DI RABDOMIOLISI P120 PSEUDOPARAPROTEINEMIA RELATED TO CONTRAST AGENT ADMINISTRATION AFTER ANGIOCARDIOGRAPHY: DETECTION IN THE βFRACTION BY CAPILLARY ELECTROPHORESIS G. Stel, F. De Biasi, P. Sala 1 Dip.di Medicina di Lab., Az. Osp-Universitaria S. Maria d. Misericordia, Udine Introduzione: La rabdomiolisi, patologia a eziologia eterogenea, comporta danno ai muscoli scheletrici con rilascio in circolo di mioglobina, molecola a basso p.m. (17.7 kD), che filtra a livello glomerulare comparendo nelle urine; essa rappresenta un rilevante fattore di tossicità tubulare. Materiali e metodi: Le urine dei tre casi di seguito riportati sono state analizzate come campioni di routine con sistema integrato Instrumentation Laboratory (iChem Velocity - iQ200 Sprint). I dosaggi della mioglobina plasmatica sono stati eseguiti in immunochemiluminescenza (Stat Myoglobin, Abbott; val. rif.: M <155, F <106 ng/mL) dopo l’osservazione della discordanza tra emoglobinuria ed ematuria. Risultati: Caso 1: F, 43 anni, utente esterna. Si rileva incongruenza tra emoglobinuria (Hb >1,00 mg/dL) e assenza di emazie. Il sospetto di rabdomiolisi è confermato dal dosaggio della mioglobina plasmatica (3941 ng/mL). La paziente aveva subito tiroidectomia totale per Ca Papillifero 20 giorni prima e presentava franco ipotiroidismo e un quadro clinico ed elettromiografico di polimiosite. Possibili cause del danno muscolare: ipotiroidismo o anestesia con Propofol. Caso 2: M, 22 anni, ricoverato in Medicina d’Urgenza. Si rileva incongruenza tra emoglobinuria (Hb >1,00 mg/ dL) e assenza di emazie. I parametri ematochimici alterati (CPK 178407 U/L; mioglobina 9461 ng/mL) ci indirizzano ulteriormente verso l’ipotesi di rabdomiolisi. Storia clinica: il paziente si era sottoposto a eccessivo sforzo fisico per ripresa di attività agonistica senza adeguato allenamento. Caso 3: M, 49 anni, utente esterno, esegue esami ematochimici di base. La discordanza tra emoglobinuria ed ematuria ci permette d’individuare la presenza di mioglobina (2600 ng/mL). Il paziente presenta mialgie diffuse e persistenti. In ricovero è formulata diagnosi di dermatomiosite. Conclusioni: L’integrazione dei dati chimico-fisici e della parte corpuscolata in automazione, riducendo il numero di campioni da rivedere, permette al laboratorista di valutare attentamente e interpretare in maniera critica i casi clinicamente più rilevanti, contribuendo a ottimizzare la gestione del paziente, talvolta suggerendo ai clinici elementi essenziali per una rapida diagnosi, con un percorso “bottom-up”. Bagley WH, Yang H, Shah KH. Rhabdomyolysis. Intern Emerg Med 2007;2:210-8. 2 1 L. Troccoli , G. Salerno , M.T. Corsetti , R. Di 1 2 2 2 Costanzo , F. De Iuliis , M.R. Favaroni , M. Falco , R. 2 2 1 1 D'Urso , A. Proietti , F. Tabacco , L. Portaro , P. 2 Cardelli 1 Central Laboratory, S. Andrea Hospital of Rome II Faculty of Medicine and Psychology ‘’Sapienza’’, Rome 2 Aim: Capillary electrophoresis has become a routine method for the detection of serum proteins. The aim of this study, was to analyze the potential interference on serum protein electrophoresis due to a contrast medium which has ultraviolet absorbance as well as serum proteins. Methods: 56 year old man with hypertriglyceridemia, hypertension and kidney failure, was admitted at coronary care unit (CCU) of S’Andrea Hospital of Rome, with acute coronary syndrome. Coronary angiography was performed in emergency using iomeprol as a contrast medium. A first blood sample was withdraw after the intervention and a second one was performed after 24 hours. Each was immediately sent to the laboratory for evaluation of troponin I, creatinine and serum protein electrophoresis. Results: Creatinine and troponin I (Tn-I) serum levels were respectively 2,2 mg/dL and 20.5 ng/mL. The serum protein electrophoresis based on ultraviolet absorbance at 200 nm (Capillarys, Sebia), showed an unusual peak in the anodic ß-fraction. After 24 h a second blood sample was withdrawn and analyzed. The Tn-I and creatinine serum levels were decreased (12.5 ng/mL and 1.9 mg/ dL respectively) while the unusual peak was unchanged. The subsequent immunofixation (Sebia Hydrasys) failed to show any monoclonal protein. Discussion and conclusions: The present case report described how a contrast medium (iohexol) can result as a “monoclonal like peak” in the ß-fraction as confirmed by immunofixation. This artifact was due to the absorbance at 200 nm of both resolved proteins and contrast medium. After 24 h the artifact was still present, because iomeprol has a renal clearance, for this reason in patients with kidney failure who have received iomeprol as contrast medium, during the preceding 2–6 days the serum protein analysis using the capillary electrophoresis should be avoided. Bossuyt X. Interferences in clinical capillary zone electrophoresis of serum proteins. Electrophoresis 2004;25:1485-7. biochimica clinica, 2012, vol. 36, n. 6 531 44° Congresso Nazionale SIBioC - Riassunti Poster P121 QUANTIFICAZIONE DEI LIVELLI INTRACELLULARI DI ATP, ADP E AMP MEDIANTE ELETTROFORESI CAPILLARE UV DETECTION AD INIEZIONE INVERSA P122 SINDROME DELLA SACCA DELLE URINE VIOLA: UN CASO 1 1 2 2 1 B. Scanu , F. Berlinguer , G. Leoni , M.A. Pinna , D. 1 1 1 1 Cambedda , S. Ena , M. Sanna , E. Pisanu , C. 1 1 1 Carru , L. Deiana , A. Zinellu 1 2 M.T. Muratore , R. Carrozza , G. Valeri , B.M. 2 Mongiardo 1 Lab. Analisi Osp. Belcolle, Viterbo U.O.C. Medicina d'Urgenza, Osp. Belcolle, Viterbo 2 1 Dipartimento di Scienze Biomediche; Università di Sassari 2 Dipartimento di Medicina Veterinaria; Università di Sassari L’ATP intracellulare è la più importante fonte di energia della cellula ed il mantenimento dell’omeostasi dei livelli di ATP ADP e AMP è un elemento cruciale per il mantenimento delle corrette attività intracellulari. Vari studi hanno dimostrato l’importanza dei livelli di ATP negli spermatozoi la cui presenza a livelli ottimali garantisce una corretta funzionalità spermatica. É stata dunque sviluppata una nuova metodica in elettroforesi capillare allo scopo di monitorare i livelli di ATP intracellulare. L’analisi dei nucleotidi veniva eseguita in elettroforesi capillare UV detection mediante una procedura di riverseinjection, in cui il campione viene caricato all’outlet per ridurre il percorso elettroforetico ed i tempi analitici. La separazione di ATP, ADP ed AMP in elettroforesi capillare può essere eseguita mediante l’impiego di un tampone sodio acetato 60 mmol/L a pH 3.8 su un capillare da 30 cm di lunghezza totale e 75 μm di diametro. In queste condizioni elettroforetiche ed utilizzando un sistema di iniezione normale i tempi analitici sono di circa di 30 min e possono essere ridotti a 10 min aggiungendo al tampone della corsa metilcellulosa ad una concentrazione finale dello 0.01%. I tempi analitici sono stati ulteriormente ridotti utilizzando il sistema di iniezione inversa che garantiva una separazione degli analiti in meno di 3 min. Le condizioni così adottate garantiscono un’ ottima riproducibilità sia intrasaggio (CV=4%) che intersaggio (CV=8%) ed un buon recupero analitico (99.0%). La metodica è stata applicata allo scopo di valutare la criotolleranza degli spermatozoi nei grifoni. Sono state eseguite delle analisi dei livelli di ATP prima e dopo la crioconservazione del seme di 4 soggetti differenti. Come atteso i livelli di ATP si riducevano a seguito della procedura di congelamento (1.19 ± 0.16 nmol ATP/10*6 spermatozoi nel seme fresco rispetto a 0.22 ± 0.27 nmol ATP/10*6 spermatozoi del seme scongelato, p< 0.001). In conclusione la metodica permette la quantificazione intracellulare di ATP fornendo un utile strumento agli studi di crioconservazione in quanto la valutazione di questo analita permette di valutare la vitalità degli spermatozoi a seguito delle procedure di congelamento. 532 biochimica clinica, 2012, vol. 36, n. 6 Le urine normalmente gialle possono assumere diverse colorazioni: arancio, rosso, verde, blu, marrone, nero, in relazione ad eventi fisiopatologici e/o a contaminanti. Recentemente è giunta alla nostra attenzione un’urina di colore viola di un paziente di anni 78 ricoverato in Medicina, per scompenso cardiaco. Al ricovero indici di flogosi aumentati, creatinina al limite superiore, transaminasi, bilirubina e fosfatasi alcalina normali, emoglobina 12.4 g/dL, globuli bianchi 4130/mmc, piastrine 96000/mmc. In seconda giornata applicazione di catetere vescicale, in diciassettesima giornata comparsa di urine viola nella sacca di raccolta. Esame chimico fisico: densità 1014, pH 8.5, albumina 30-70 mg/dL, emoglobina assente, esterasi leucocitaria 500, nitriti assenti; sedimento: cristalli di triplo fosfato, >40 leucociti pcm, batteri, corpuscoli nero-violacei. Viene consigliata dal laboratorio l’esecuzione dell’urinocoltura e del profilo proteico urinario. Al paziente viene sostituito il catetere, somministrata idratazione con 1000 cc di fisiologica ed effettuati lavaggi vescicali. In diciottesima giornata le urine tornano chiare, il sedimento evidenzia tappeto di leucociti, >2 cilindri ialini pcm, cristalli di triplo fosfato, emazie isomorfe e fosfati amorfi ed assenza dei corpuscoli violacei del giorno precedente. Il profilo proteico urinario evidenzia una lieve proteinuria glomerulare non selettiva. L’urinocoltura evidenzia un’infezione urinaria con carica batterica costituita da Proteus Mirabilis >100000 ufc/mL risolta con chinolonici per os. E’ stata diagnosticata una PUBS (purple urine bag syndrome), patologia attribuibile a infezione del tratto urinario soprattutto in pazienti cateterizzati con costipazione intestinale. Questa rara sindrome riscontrata già nel 1812 al re Giorgio III e descritta in letteratura nel 1978 è dovuta alla presenza nelle urine di batteri (Klebsiella spp, P.mirabilis, E.coli, Providencia stuarti, Enterococcus spp) producenti indossil solfatasi. Il triptofano alimentare, deaminato dalla flora intestinale ad indolo, è poi trasformato in indossile solfato infine ossidato a indaco e indirubina responsabili del colore viola. La sindrome malgrado le apparenze è normalmente benigna. Hadano Y, Shimizu T, Takada S, et al. An update on purple urine bag syndrome. Int J Gen Med 2012;5:707-10. 44° Congresso Nazionale SIBioC - Riassunti Poster P123 STUDIO DI PREVALENZA DELLE DOPPIE O TRIPLE COMPONENTI MONOCLONALI E DELLE COMPONENTI BICLONALI E TRICLONALI NEI LABORATORI DEL SERVIZIO DI PATOLOGIA CLINICA DELL’A.O.O.R. PAPARDO-PIEMONTE DI MESSINA G. Falliti, G. Sauta, M.L. Natoli, L. Baldini, A. Barrile , P. Irrera, P. Noto, F. Tavilla, M.L. Giunta Servizio di Patologia Clinica, A.O.O.R. PapardoPiemonte, Messina Introduzione: Oltre a malattie immunoproliferative caratterizzate dalla produzione di Ig monoclonali e di gammopatie monoclonali benigne esistono situazioni contraddistinte dalla dimostrazione elettroforetica di due o tre CM, la cui presenza non implica necessariamente una diagnosi di processo evolutivo maligno. Esiste sia una doppia o tripla CM di significato indeterminato (65% dei casi), sia la doppia o tripla CM mielomatosa (16%) che quella associata a linfomi, macroglobulinemia di Waldenström, LLC e malattie linfoproliferative non classificate (19%). I pazienti con doppia o tripla CM di significato incerto rimangono solitamente clinicamente stabili, tranne nei rari casi in cui si ha un’evoluzione verso un mieloma multiplo. Esiste inoltre la componente bi-e triclonale,dovuta alla proliferazione di due o tre cloni di cellule immunocompetenti, producenti Ig o catene leggere libere dello stesso tipo. Materiali e metodi: L’elettroforesi proteica capillare si esegue tramite lo strumento “Capillarys” della ditta SEBIA, utilizzato altresì per effettuare l’immunosottrazione. L’immunofissazione su gel d’agarosio si esegue utilizzando lo strumento “Hydrasis” della ditta SEBIA. Risultati: Dall’analisi delle IFEs del quinquennio 2008-2012 si è notata un’ampia variabilità di doppie CM, con una percentuale del 2,45% sul totale di curve presentanti CM e casi di tripli CM (0,38%). E’stato messo in evidenza anche un caso di tripla CM di un paziente ricoverato nel reparto di dialisi. Questa presenza pur rappresentando un campanello d’allarme è stata diagnosticata come condizione transitoria riferibile ad eventi clinici non prettamente ematologici. Si nota una discreta percentuale (1,99%) di componenti biclonali e rari casi di componenti triclonali. Infine nelle IFEu sono state evidenziate alcune doppie CM (0,67%) ed un caso di tripla CM. Conclusioni: La bassa frequenza di curve con doppie o triple CM e componenti bi- e triclonale favorisce l’applicazione di protocolli di monitoraggio della progressività delle condizioni dei pochi pazienti presentanti tali particolari anomalie. In futuro le doppie e triple CM e le componenti biclonali e triclonali saranno studiate in maniera più approfondita per l’applicazione di protocolli di studio sulla “malattia minima residua”. P124 STUDIO DI PREVALENZA DELLE COMPONENTI MONOCLONALI NEI LABORATORI DEL SERVIZIO DI PATOLOGIA CLINICA DELL’A.O.O.R. PAPARDOPIEMONTE DI MESSINA G. Falliti, G. Sauta, M.L. Natoli, G. Siracusa, A. Cavaleri, A. Barbera, R. Gervasi, M. Carilli, M.L. Giunta Servizio di Patologia Clinica, A.O.O.R. PapardoPiemonte, Messina Introduzione. Le CM nel tracciato elettroforetico inducono ad adottare algoritmi diagnostici per la quantificazione delle componenti stesse, fornire indizi sulla loro natura consentendo adeguate diagnosi e trattamenti terapeutici. Quando la CM è <3 g/dL e non è accompagnata da nessuna alterazione nell’organismo si parla di MGUS. Le CM sono tipizzate con l’immunofissazione (IFE) o l’immunosottrazione (ISE). E’ possibile definirne la natura benigna o maligna solo con il criterio di progressività. Materiali e Metodi: L’elettroforesi proteica capillare ed Immunosottrazione si eseguono con lo strumento “Capillarys” della ditta SEBIA. L’immunofissazione su gel d’agarosio si esegue impiegando lo strumento “Hydrasis” della ditta SEBIA. Risultati: Sono stati analizzati i dati riguardanti le curve patologiche della foresi dal 2009 al 2012. Prese in considerazione la provenienza dei pazienti ovvero se ricoverati nei due Presidi Ospedalieri dell’A.O.O.R. Papardo-Piemonte, se utenti esterni, il loro sesso e la loro età, abbiamo evidenziato, scartando le ripetizioni, 24228 tracciati elettroforetici, di cui 1298 patologici e 656 presentanti CM. Nel P.O. “Papardo” si è osservata una media del 7% di curve patologiche ed una media del 3,3% presentanti CM. Nel P.O. “Piemonte” si è evidenziata una media di curve patologiche del 2,16%, ed una media dell’1,56% presentanti CM. Età media di individui con la CM è di 68,51 anni con prevalenza di 1,17 negli uomini (54%) rispetto alle donne (46%). Nelle IFEs si è notata una prevalenza delle CM di tipo IgGκ. Nelle IFEu si è osservata la prevalenza di CM di tipo IgGλ. Conclusioni: La differenza di percentuali di CM tra i due Presidi Ospedalieri è giustificata dalla presenza di pazienti del reparto di Ematologia nel P.O. “Papardo” con una percentuale del 68% rispetto alla totalità dei casi osservati di CM. Tale percentuale ci consente di attuare protocolli operativi e flow-chart dedicati. Di Pietro R, Portera M, Antoci F, et al. Screening di CM in un campione rappresentativo della popolazione siciliana nel distretto nebroideo. Biochim Clin 2005;29:245. Dolci A, Vernocchi A. Aspetti metodologici nella ricerca e caratterizzazione delle componenti monoclonali nel siero. Biochim Clin 2012;36:84-7. biochimica clinica, 2012, vol. 36, n. 6 533 44° Congresso Nazionale SIBioC - Riassunti Poster P125 ULERA CORNEALE DA PSEUDOMONAS E ACANTHAMOEBA IN PAZIENTE PORTATORE DI LENTI A CONTATTO P126 VALUTAZIONE DEL CITOFLUORIMETRO SYSMEX UF-1000i NELLA DETERMINAZIONE DEL NUMERO DI SPERMATOZOI NEL LIQUIDO SEMINALE V. Cortese, G. Carlini, M. Cioffi, C. Maisto, M.R. Righetti, L. De Cristofano, R. Miceli, A. Monteforte, A. Pesce, P. Rotondo, M.T. Polistina G. Previtali, S. Bussaconi, C. Fermi, P. Rossetti, A. Turini Lab. Patologia Clinica P.O. San Giovanni Bosco Introduzione: Il genere Pseudomonas è formato da bacilli Gram negativi. La specie aeruginosa è la più diffusa,le infezioni da essi provocate possono interessare molti distretti anatomici. Un’infezione dell'occhio sostenuta da Pseudomonas aeruginosa spesso risulta secondaria a contaminazione delle lenti a contatto. Oltre ai bacilli del genere Pseudomonas, l'occhio può essere attaccato anche da un protozoo patogeno veicolato dalla polvere l'Acanthamoeba. Caso clinico: Paziente portatrice di lenti a contatto morbide, si è presentata all'attenzione degli oculisti, riferendo dolore intenso all'occhio sinistro, fotofobia, riduzione del visus e presenza di secrezione abbondante. Il materiale purulento è stato raccolto con un tampone ed inviato in Microbiologia, per l’esecuzione dell'esame colturale. Materiali/metodi: Giunto in laboratorio sono state allestite semine su terreni selettivi. Dopo 24 ore a 37 °C su agar cetrimmide si sono sviluppate delle colonie successivamente identificate per Pseudomonas aeruginosa dal sistema Vitek 2 della Bio-Merieux. L'antibiogramma è stato eseguito con il metodo Kirby Bauer utilizzando solo dischetti corrispondenti ad antibiotici disponibili sotto forma di colliri e/o pomate oftalmiche. Risultati: La paziente è stata trattata dagli oculisti, con instillazioni di Levofloxacina collirio e Colistina preparazione iniettabile per instillazione topica. La terapia è proseguita poi con la sola Levofloxacina collirio fino a cinque giorni dopo la completa riepitelizzazione. In seguito si è verificata una riacutizzazione del processo flogistico che ha reso necessario un ulteriore approfondimento diagnostico dal quale è emerso la scomparsa dello Pseudomonas, ma allo scraping si è avuta la presenza di cisti di Acantoameba. A guarigione avvenuta, la paziente è stata sottoposta a trapianto di cornea. Conclusioni: Un’infezione mista della cornea da Pseudomonas ed Acantoameba costituisce, in oftalmologia, un evento di estrema gravità. In caso di infezioni sostenute da tali patogeni è fondamentale approntare subito un idoneo protocollo diagnostico e terapeutico. Questo dimostra che è indispensabile, con pazienti “gravi”, la stretta collaborazione tra microbiologo ed oculista, vista anche la diffusione sempre maggiore che le lenti a contatto stanno avendo. 534 biochimica clinica, 2012, vol. 36, n. 6 U.O. di Patologia Clinica, Osp. di Fidenza, AUSL di Parma La determinazione del numero di spermatozoi è fondamentale nel valutare la fertilità maschile. Da alcuni anni è stato introdotto in commercio il citofluorimetro Sysmex UF-1000i, come evoluzione del Sysmex UF-100,che è un analizzatore automatico dedicato all'esame del sedimento urinario. Scopo di questo studio è stato quello di valutare l'analizzatore Sysmex UF-1000i nella determinazione del numero di spermatozoi confrontando i dati in citofluorimetria con quelli ottenuti con la microscopia ottica in camera di Thoma. Nel rispetto della dichiarazione di Helsinki sono stati utilizzati in maniera anonima 150 campioni di liquido seminale raccolti secondo le indicazioni del manuale WHO. Dopo fluidificazione i campioni, diluiti con soluzione spermicida, sono stati analizzati effettuando contemporaneamente il conteggio degli spermatozoi sia con microscopio ottico (diluizione: 1/20) che con analizzatore UF-1000i (diluizione: 1/100). Le due metodiche sono state messe a confronto mediante regressione di Passing-Bablok e diagramma delle differenze di Bland Altman. La regressione di Passing-Bablok mostrava una retta pari a y = 0,933x + 1,27. L'intervallo di confidenza al 95% (CI) per l'intercetta era compreso tra 0,43 e 2,58; il CI per il coefficiente angolare era compreso fra 0,88 e 0,98. Nel diagramma di Bland Altman risultava una differenza percentuale media di + 0,2% con un CI compreso fra - 3,52% e + 3,92%. I limiti inferiore e superiore delle differenze in percentuale osservate erano rispettivamente : - 38,1% e +38,6%. L'analisi statistica evidenziava una buona correlazione fra i due metodi con un test di Cusum che indicava una non significativa deviazione dalla linearità (p>0,10),anche l'analisi delle differenze percentuali mostrava differenze statisticamente non significative fra i due metodi. La necessità di standardizzazione e le difficoltà di conteggio nelle camere citometriche incoraggiano l'utilizzo del sistema diagnostico Sysmex UF-1000i nella determinazione degli spermatozoi nel liquido seminale. World Health Organization. Laboratory manual for the axamination of human semen and sperm-cervical mucus interaction. Cambrige: University Press, 2009. 44° Congresso Nazionale SIBioC - Riassunti Poster P127 VALUTAZIONE DEL RISCHIO CHIMICO AL QUALE E’ ESPOSTO IL PERSONALE DEL LABORATORIO MEDICO DELL’ASL DI VARESE P128 ALLERGIA ALIMENTARE AL GRANO: UTILITA' DEL TRI A 14 1 L. Bressan, N. Corcione Lab. Medico, Dip. di Prevenzione Medico, ASL Varese Il laboratorio è un ambito lavorativo che presenta rischi per la salute e la sicurezza del personale e spesso tale rischio non è percepito, con la conseguente possibilità di danni per gli operatori. Con lo studio ci proponiamo di valutare il rischio chimico (RC) al quale è esposto il personale dell’U.O. Laboratorio Medico dell’ASL di Varese. Esso prevede una valutazione preliminare e in seguito approfondita del RC. La valutazione preliminare è stata eseguita con la metodologia Hierarchisation des risques potentiels che porta alla determinazione della classe di priorità: A, B o C. Per le sostanze chimiche della classe A, valore numerico (v.n.) tra 1 e 8 o B v.n. tra 9 e 18, è necessario eseguire l’analisi dettagliata del RC poiché è probabile che queste sostanze presentino un rischio non irrilevante per la sicurezza dei lavoratori; per quelle relative alla classe C, con v.n. tra 19 e 25, il rischio è irrilevante. Bisogna precisare che l’algoritmo adottato presenta delle criticità che potrebbero sovrastimare la sostanza chimica collocandola in una classe di priorità più alta. Per ovviare a tale inconveniente, sono stati considerati i prodotti chimici con v.n. da 1 a 15. La valutazione approfondita del RC è stata condotta usando il Movarisch che consente di assegnare un v.n. al rischio in modo da classificare la sostanza nel seguente modo: rischio irrilevante per la salute con R: 0,1≤R<15 e 15≤R<21 (intervallo di incertezza) o rischio superiore al rischio irrilevante per la salute (21≤R≤40, 40<R≤ 80 e R>80). Sono state valutate 81 sostanze. Dall’analisi preliminare è stata accertata la presenza di 17 sostanze appartenenti alle classi A e B; successivamente, esse sono state sottoposte a valutazione approfondita del RC dal quale è emerso che 2 sostanze presentano un valore di R nell’intervallo di incertezza (supplemento di crescita legionella BCYE e NAOH), 7 sostanze hanno un rischio irrilevante per la salute e 8 sostanze presentano un rischio superiore al RC irrilevante per la salute (Supplemento selettivo Bolton Broth e Preston Campylobacter, NIN, ZYM B, metanolo, acetamide, reattivo di Nessler, ipoclorito di sodio). I dati ottenuti ci sembrano confortanti e indicano che RC nel laboratorio medico è basso per la sicurezza e irrilevante per la salute dell’operatore. 2 1 1 B. Cinti , L. Antonicelli , V. Viola , G. Ciarrocchi , M. 1 Tocchini 1 Lab. Analisi, Azienda Ospedaliero-Universitaria Ospedali Riuniti, Ancona 2 Allergologia, Azienda Ospedaliero-Universitaria Ospedali Riuniti, Ancona L'introduzione nel nuovo pannello del microarray ImmunoCAP ISAC (ThermoFisher) della LTP (Lipid Transfer Protein) del grano, rTri a14, ha facilitato la gestione di un caso di allergia alimentare complesso. Una paziente, di 35 anni, con già diagnosticata allergia respiratoria (acari, graminacee, cipresso, gatto) e sospetta allergia alimentare (orticaria/angioedema e anafilassi da esercizio fisico dopo assunzione di frutta, mais, grano) è giunta alla nostra osservazione per reazione anafilattica dopo ingestione di una piadina. Le IgE specifiche testate presso un altro centro (ImmunoCAP-ThermoFisher), evidenziavano, oltre agli inalanti, positività per grano, mais, grano saraceno, pomodoro, prezzemolo, assenzio, semi di girasole, e per le LTP alimentari testabili con questo sistema: rPru p3, rAra h9, rCor a8. I prick tests da noi effettuati confermavano le positività verso pesca, arachide, nocciola, pomodoro, farina e mais. La dieta di esclusione, autogestita dalla paziente e sempre più allargata, determinava un vistoso dimagrimento e grave compromissione della vita sociale. E' stato quindi testato il siero su ImmunoCAPISAC (ThermoFisher). Il risultato ha confermato l'allergia verso gli inalanti e ha evidenziato la positività verso tutte le Lipid Transfer Protein (LTP) presenti nel microarray: rAra h9, rCor a8, nJug r3, rPru p3, nArt v3, rPla a3 ed in particolare rTri a14 = LTP del grano, inserita nel nuovo pannello ISAC da 112 allergeni. Non sono state rilevate IgE specifiche verso le altre componenti molecolari del grano. La rTri a14, a differenza delle altre LTP, risulta essere termolabile; il test di esposizione orale ad alimenti con patata cotta, riso cotto, pasta cotta ha dato in effetti esito negativo. E' seguita una normalizzazione della dieta con la graduale reintroduzione di alimenti quali patata, pasta cotta, verdure cotte, mela e pesca sbucciate. La sensibilizzazione a rTri a14, nota anche come causa dell' “asma del fornaio”, è associata a problemi respiratori, più che a problemi alimentari. La cottura dei cibi contenenti grano e derivati, ne permette l'assunzione. Sono da evitare in ogni caso alimenti contenenti farina poco cotta come pizza e piadina. biochimica clinica, 2012, vol. 36, n. 6 535 44° Congresso Nazionale SIBioC - Riassunti Poster P129 ESAMI DI SCREENING PER I NEO ASSUNTI: UTILITA' DELLA CRD NELLA SENSIBILIZZAZIONE AL LATTICE DI GOMMA P130 ESTRATTI E FRAZIONI MOLECOLARI IN SINERGIA NELLA DIAGNOSTICA ALLERGOLOGICA MOLECOLARE: UN CASO CLINICO INTERESSANTE V. Viola, B. Cinti , G. Ciarrocchi , M. D'Anzeo, T. Santini, L. Marinelli, M. Tocchini B. Cinti , L. Antonicelli , V. Viola , G. Ciarrocchi , M. 1 Tocchini Laboratorio Analisi, Azienda Ospedaliero-Universitaria Ospedali Riuniti, Ancona 1 2 1 1 1 Lab. Analisi, A.O.U. Ospedali Riuniti, Ancona Allergologia, AOU Ospedali Riuniti, Ancona 2 La prevalenza di sensibilizzazione al lattice di gomma risulta essere nella popolazione generale del 3,3-18,6% (secondo la popolazione studiata e il test diagnostico utilizzato) e del 3-17% negli operatori sanitari altamente esposti. Nella gestione delle criticità del rischio lavorativo l’Azienda Ospedali Riuniti di Ancona prevede per gli operatori sanitari obbligati ai DPI (dispositivi di protezione individuale), l'inserimento del dosaggio delle IgE specifiche (sIgE) per il lattice di gomma (k82) nel pannello degli esami ematochimici da testare al momento dell'assunzione. Solo in caso di positività (sIgE per k82 >0,10 KUa/L), si procede con la ricerca delle sIgE verso le singole molecole allergeniche in modo da fornire un preciso profilo di sensibilizzazione. Il dosaggio delle sIgE verso il lattice è stato eseguito su un analizzatore UniCap 250 - metodo FEIA (ThermoFisher). Sono stati eseguiti dosaggi su 478 campioni di operatori sanitari (ausiliari, infermieri, tecnici di laboratorio, medici, biologi,..) inviati dal DSTB (Ufficio Medico Competente) nel periodo compreso dal 01/01/10 al 30/06/12. Dei 478 campioni testati, 13 (pari al 2,7%) sono risultati positivi al k82 (0,67 KUa/L– 14,9 KUa/L); nei positivi, la ricerca di sIgE verso le singole molecole allergeniche ha evidenziato in 11 campioni (84,6%) la sola positività verso la profilina rHev b8; un operatore sanitario, chirurgo, ha riportato sIgE per Hev b 5 pari a 4,77 KUa/L, mentre le sIgE di un secondo operatore, infermiere, sono risultate positive per Hev b 6.01=0,80 KUa/L e Hev b 6.02 = 0,72 KUa/L. In questo studio quindi la prevalenza vera di sensibilizzazione al lattice di gomma negli aspiranti operatori sanitari scende al 0,4%. La CRD nella diagnostica allergologica in vitro è fondamentale per smascherare le cross-reattività: in particolare nella sensibilizzazione al lattice di gomma la CRD permette di distinguere una sensibilizzazione alla profilina, panallergene comune all'ambiente vegetale, di scarso significato allergologico, da una più grave verso componenti molecolari, quali Hev b5 e Hev b6, che rivestono una rilevanza clinicamente significativa soprattutto negli operatori sanitari esposti al lattice. 536 biochimica clinica, 2012, vol. 36, n. 6 La diagnostica allergologica in vitro si avvale oggi del dosaggio delle IgE specifiche verso gli estratti allergenici e verso le singole componenti molecolari ricombinanti o altamente purificate. Nell'aprile 2012 è giunta alla nostra osservazione una paziente, di 10 anni, per sindrome orale allergica (SOA) e angioedema al volto, a seguito di ingestione di carne di pollo. Sintesi anamnestica: nel 2003, all'età di un anno, l'ingestione di pesce (sogliola) aveva causato orticaria generalizzata e tosse insistente. Era stato quindi escluso totalmente il pesce dalla dieta e nonostante ciò si erano manifestati successivamemente episodi di eruzioni cutanee al semplice contatto con oggetti contaminati da residui di pesce. Nel 2010 erano insorti disturbi faringei dopo ingestione di noce e venivano segnalati transitori episodi di dispnea da sensibilizzazione verso inalanti (acari e cipresso). Nel 2012 si è manifestata una sindrome orale allergica e angioedema al volto dopo ingestione di carne di pollo; in quell'occasione è stato prelevato il siero e testato con il sistema in microarray ImmunoCAP®ISAC (ThermoFisher). Il risultato ha confermato la presenza di IgE specifiche (sIgE) verso noce (nJug r1), cipresso (nCup a1) e acari (rDer f2 e nDer p1) e verso il pesce (rGad c1 - parvalbumina). Risultavano completamente assenti le sIgE verso le altre albumine sieriche e la livetina, l'albumina sierica del pollo (nGal d 5). L'ipotesi formulata è stata allora che la carne di pollo, fino a quel momento consumata senza problemi, fosse stata causa di reazione in quanto contaminata durante la manipolazione con del pesce o che l'animale fosse stato alimentato con mangimi contenenti farine di pesce. Al fine di confermare quest'ipotesi, abbiamo dosato le sIgE verso l'estratto di pollo (f83) su ImmunoCAP 250 (ThermoFisher). Il risultato è stato sIgE = 0,29 KU/L. E' stato effettuato lo skin prick test con estratti di pollo, di due ditte differenti (Alk Abellò e Lofarma) che ha confermato la positività rilevata in vitro. Il percorso diagnostico seguito per questa paziente, dimostra che la diagnostica sierologica tradizionale basata sugli estratti può essere di supporto e a completamento della più sottile e innovativa diagnostica molecolare su microarray. 44° Congresso Nazionale SIBioC - Riassunti Poster P133 VALUTAZIONE DELLA PERFORMANCE DI UN NUOVO TEST QUANTITATIVO PER IL DOSAGGIO DELLE IgE SPECIFICHE SU SIERO UMANO CON METODICA IN IMMUNOBLOT A. Caccamo, G. Genovese, P. Sarica, D. Mazzacuva, M. Francone, R.E. Saladino, G. Romeo Lab. di Tipizzazione Tissutale, Az. Osp. BMM di Reggio Calabria Scopo: valutare la performance analitica di un nuovo sistema diagnostico immunoblot per la quantificazione di IgE specifiche su siero umano, espresse in UI/ml e classe allergenica con accuratezza decimale. Materiali e metodi: “Allergyscreen”, Mediwiss GmbH, usa tecnologia immunoblot con allergeni o mix fissati su membrane di nitrocellulosa. Ogni banda si riferisce ad un singolo allergene o mix. La membrana contiene 20 bande e il controllo pos. Un lettore automatico legge le strip, il software di analisi elabora i dati ed archivia i referti. I risultati sono espressi in IU e classe allergenica. Il sistema è stato valutato partecipando al programma VEQ gestito da DigitalPT per VEQ membro Internazionale di EQA, presso AOU di BO S.Orsola-Malpighi: programmi ALLY443 (inalanti), FOOD443 (alimenti). I programmi annuali prevedono 4 invii trimestrali. Sono stati raffrontati i risultati ottenuti da “Allergyscreen” con quelli ottenuti da ~ 65 laboratori con tecnologia ImmunoCAP considerata riferimento per la diffusione internazionale. Risultati: in ALLY433 sono stati testati: D1, D2, M6, E1, E2, E5, T3, T4, T9, W19, W21, I1, I3 alcuni con 2/3 invii. I risultati delle due metodiche sono sovrapponibili come da schede riassuntive. Le positività sono state tutte riconosciute: per 14 allergeni veniva data stessa classe, per 10 di questi il valore in KU/L rientrava nella dDS, per 11 allergeni veniva assegnata una classe allergenica diversa (per 8 una/due classi sup., per 2 una classe inf.). In FOOD443 sono stati testati: F1, F2, F4, F13, F17, F25, F26, F49, F84, F95, alcuni in più invii. I risultati delle due metodiche sono sovrapponibili. Le positività sono state così riconosciute: 15 all. stessa classe, per 6 di questi il valore KU/L rientrava nella dDS; per 5 veniva assegnata una classe allergenica diversa (3 una o più classi sup., 2 una classe inf.). Agli all. F2, F26, F95, in due invii, è stata assegnata con entrambe le metodiche classe 0. In un solo episodio, in approfondimento, l’allergeneF17, analizzato in due invii, ha avuto nel I° invio classe 0 contro classe 1, 2 o 3; nel II° ha avuto classe 3 come 31 laboratori su 57. Conclusioni: La metodica Allergyscreen ha confermato la correttezza di tutte le risposte e l’assoluta sovrapponibilità dei risultati con ImmunoCAP. 538 biochimica clinica, 2012, vol. 36, n. 6 P134 DETERMINATION OF URINARY EXCRETION OF CYSTINE BY HPLC-FL ON HEALTHY POPULATION 1 1 1 F. Corrente , J. Gervasoni , A. Cocci , B. 2 1 1 Zappacosta , C. Zuppi , S. Persichilli 1 Laboratorio Analisi I, Policlinico Universitario A. Gemelli, Roma 2 U.O.C. Laboratorio Analisi, Fondazione di Ricerca e Cura Giovanni Paolo II, Campobasso Introduction: Cystinuria is an inheritable autosomal recessive disorder of amino acids transport affecting the epithelial cells of the renal tubules and gastrointestinal tract. It is characterized by abnormal urinary concentrations of cystine and other dibasic amino acids, resulting in formation of crystals increasing risk of kidney stones. Initially in our laboratory cystinuria was measured by a semiquantitative method based on the reaction of cyanide nitroprusside (Brand’s test). However, diagnosis and therapeutic control of cystinuria required an accurate determination of the urinary cystine concentration. Therefore, a quantitative measure by an HPLC method was preferred to Brand’s test. In this work we report cystinuria evaluation on a healthy population proposing cutoff values by HPLC-FL method. Methods: Eighty 24-h urine samples were collected from healthy subjects (37 male and 43 female; 20-80 age range). Our method involves the use of tri-n-butylphosphine to reduce disulfides in urine to their reduced forms. After protein precipitation with trichloroacetic acid, the reduced sulfhydryl groups were derivatized using the thiol-specific fluorogenic reagent 4-(aminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole (ABD-F) in borate buffer (pH 8). The reaction products were separated by HPLC, detected and quantified by fluorescence detection (λex: 385 nm; λem: 515 nm). Integration and elaboration of the chromatographic peaks were carried out by using ChromQuest 5.0 software (Thermo Fisher Scientific). Urinary creatinine was quantified using an enzymatic method (Cobas C311, Roche Diagnostics). Results: We determined the reference values of cystine in urine of healthy subjects. Total cystine was 84,5±42,5 μmol/g creatinine (mean±DS) and it ranged from 14,8 to 166,0 μmol/g creatinine (2,5th - 97,5th percentiles). Conclusions: These values well agree with reference ranges of cystinuria obtained by other Authors using both HPLC and LC-MS/MS analysis. The cystine levels in our group showed a Gaussian distribution with a typical bellshaped curve. No differences were observed between males and females. Kusmierek K, Chwatko G, Glowacki R, et al. Determination of endogenous thiols and thiol drugs in urine by HPLC with ultraviolet detection. J Chromatogr B Analyt Technol Biomed Life Sci 2009;877:3300-8. 44° Congresso Nazionale SIBioC - Riassunti Poster P135 ESTIMATED GLOMERULAR FILTRATION RATE MAY HELP DETECT CHRONIC KIDNEY DISEASE IN ELDERLY PEOPLE WITH SERUM CREATININE STILL IN THE NORMAL RANGE 1 2 3 1 F. Busco , R. Festa , R. Testa , A. Marziali , A.R. 3 1 1 Bonfigli , M. Boemi , R. Galeazzi 1 Laboratorio Analisi Chimico-Cliniche e Molecolari, INRCA, Ancona 2 Dipartimento di Scienze Cliniche e Molecolari, Università Politecnica delle Marche 3 Centro Ricerche Metaboliche sul Diabete e gli Alimenti, INRCA, Ancona Aim: Chronic kidney disease (CKD) is a condition of great impact on both the quality and quantity of life, as well as healthcare costs. It is an age-related disease, with important and common conditions as risk factors: cardiovascular disease, diabetes, hypertension, obesity. So, prevention and early diagnosis are crucial. A simple and cheap lab test correlating closely with the glomerular filtration rate (GFR) would be the ideal approach. Serum creatinine alone is not a reliable marker of CKD, especially in the elderly population, because of the creatinine-blind range. In fact, serum creatinine decreases with age despite the decline in GFR, resulting in an increased number of patients with CKD but a normal creatinine value. The aim of this study was to test the effectiveness of estimated GFR (eGFR) to identify the presence of CKD in elderly patients with serum creatinine in the blind range, i.e. still normal. Methods: Seventy patients from INRCA hospital in Ancona, both outpatients and hospitalized (excluding nephrology and dialysis clinics), aged 75-95 years, with serum creatinine 0.6 to 1.2 mg/dL, were randomly selected. GFR was measured by means of the creatinine clearance test and was estimated using the CKD-EPI formula. Diagnostic cut-off was set at 60 mL/min (CKD stage ≥ 3). Creatinine clearance was used as reference test. The concordance between the two methods was investigated. Results: The prevalence of CKD in this population was 63±11% (95% CI). The eGFRCKD-EPI showed the following performances: sensitivity = 65%±14%; specificity = 73% ±17%; PPV = 80%±13%; NPV = 56%±17%. Conclusions: The prevalence of CKD is high in the elderly population with normal serum creatinine. eGFRCKD-EPI at the cut-off of 60 mL/min is able to identify two-thirds of these cases, with a rate of false positivity of 20%. It looks like a pretty good result for a free-of-charge information, obtained from a serum creatinine value otherwise almost useless. Earley A, Miskulin D, Lamb EJ, et al. Estimating equations for glomerular filtration rate in the era of creatinine standardization: a systematic review. Ann Intern Med 2012;156:785-95. P136 MONITORING OF PLASMA AND ERYTHROCYTES PHOSPHOLIPID FATTY ACID IN THE GENERAL POPULATION AND IN ITALIAN HEMODIALYSIS PATIENTS 1 1 2 A. De Stefano , P. Bertucci , A. Noce , S. 1 1 1 1 Ballerini , M.T. Caliò , P. Casalino , S. Bernardini , M. 1 Dessi 1 Dip. Medicina di Laboratorio Università Tor Vergata Roma 2 Servizio Nefrologia e Ipertensione Università Tor Vergata Roma Epidemiological studies have shown that cardiovascular’s mortality observed in uremic patients aged between 25-35 years, is equal to that observed in the general population over 85 years. This phenomenon can be explained only by considering factors associated with chronic renal failure (proteinuria, malnutrition, inflammatory state, oxidative stress, etc.). It is shown that ω-3 polyunsaturated fatty acids (PUFA) reduce the risk of cardiovascular disease (CVD) in the general population. The goal of our work was to evaluate the plasma total and red blood cell membrane PUFA composition in a group of Caucasians patients in chronic tri-weekly hemodialysis, and in a group of healthy subjects (control group). In addition, the relationship between fatty acids ω-3 and ω-6 (ARA/EPA/DHA and ARA) and the possible differences in PUFAs concentrations were evaluated. We enrolled 99 HD and 160 control subjects, none treated with drugs or antioxidant dietary supplements for at least 90 days. The blood samples were analysed using a gas-chromatographic system coupled to a spectrometric mass detector. The daily intake of total calories, animal protein and vegetable, animal and plant lipids, carbohydrates, of the fibers and of retinol, is significantly lower in patients undergoing dialysis than those belonging to the control group (p <0.001). Plasma levels of triglycerides (p <0.0001), total cholesterol (p <0.05) and LDL cholesterol (p<0.05), are significantly higher in dialysis patients, while the level of HDL cholesterol (p <0.05) was significantly lower. Among the plasma PUFA, C20: 3 (DHA) (p < 0.001), 20: 4 (ARA) (p < 0.001), C18: 2 (p < 0.001), C18: 3 (p < 0.001) and C20: 5 (EPA) (p = 0.0081) were significantly reduced in HD patients. Among the erythrocyte PUFA, C18:2, the DHA, the ARA, C18:3 and the erythrocyte PUFAs ratios were significantly reduced in uremic patients (p < 0.0001). A dieto-therapy treatment to increase PUFAs levels of ω-3 (EPA and DHA) and to optimize the ω-6/ω-3 ratio, could exercise a CV protective action as fatty acid composition reflects that of the myocardium and is influenced by diet. We have found that many classes of PUFAs are lacking in HD patients, due to the removal of nutrients through the dialysis and to persistent malnutrition. biochimica clinica, 2012, vol. 36, n. 6 539 44° Congresso Nazionale SIBioC - Riassunti Poster P139 URINARY EXOSOME PROTEIN COMPOSITION IN HEREDITARY TUBULOPATHIES: TOWARD BIOMARKERS DISCOVERY 1 1 1 F. Raimondo , L. Morosi , S. Corbetta , A. 2 3 1 1 Bettinelli , P.L. Pozzi , P. Brambilla , F. Magni , M. 1 Pitto 1 Dept. of Health Sciences, Univ. Milano-Bicocca, Monza 2 Dept. of Pediatrics, San Leopoldo Mandic Hospital, Merate-Lecco 3 Dept. of Laboratory Medicine, San Leopoldo Mandic Hospital, Merate-Lecco Among the different forms of hereditary renal tubulopathies (HRT) associated with hypokalemia, metabolic alkalosis and normotension, two main types of disorders have been identified: Gitelman disease, which appears to be a homogeneous post-Henle's loop disorder, and Bartter syndrome, a heterogeneous Henle loop disorder. A specific gene has been found responsible for Gitelman disease, encoding the thiazide-sensitive Na-Cl cotransporter (NCCT) of the distal convoluted tubule, while many different genes have been shown to be responsible for Bartter syndrome. Many of these disorders can be diagnosed by a combination of specific disturbances in plasma and urine parameters. However, this field may also benefit from the developments in urinary proteomics. More specifically, most of the transporters along the nephron are excreted in urine in so-called urinary exosomes. Therefore, the aim of this work is the isolation of urinary exosomes and the study of their composition in order to provide urinary biomarkers for HRT. 2nd morning urines were collected from 21 Gitelman patients (age 14,8 ± 9,4), from 17 Bartter ones (age 13,2 ± 9,1) and from 38 ageand sex-matched controls. After urinary vesicle isolation by ultracentrifugation, and exosome characterization by immunoblotting with known markers (TSG101, AQP1), proteins were analyzed by EF and WB with antibodies against the disease-related transporters. The biochemical characterization of urinary vesicles shows the purity of our samples by the assessment of the exosomal markers TSG101 and AQP1 in exosomes of both patients and controls. The IB analysis of NCCT revealed the absence of the protein in urinary exosomes of all Gitelman patients, as expected, but also in some controls’ one, suggesting its possible diagnostic role in excluding, (but not in confirming), the Gitelman syndrome in children with presumptive symptoms. These results suggest that exosome isolation may provide an efficient first step in HRT biomarker discovery in urine. Grants from FIRB: Rete Nazionale per lo studio del proteoma umano (n. RBRN07BMCT). P140 URINARY NGAL AS A VALUABLE MARKER OF KIDNEY GRAFT PERFUSION: A PRELIMINARY PEDIATRIC EXPERIENCE 1 1 1 C. Cosma , M. Zaninotto , M.C. Varagnolo , A. 2 3 3 1 Amigoni , E. Vidal , L. Murer , M. Plebani 1 Dep. of Laboratory Medicine, University-Hospital, Padova 2 Dep. of Paediatrics, Paediatric Intensive Care Unit, University of Padua, Padova 3 Dep. of Oncological and Surgical Sciences, Section of Paediatric Urology, Urology Unit, University Hospital of Padua, Padova Background: The assessment of adequate renal perfusion is essential in the first hrs after kidney transplantation (KTx) and it is usually based on the evaluation of clinical parameters. The common clinical and laboratory markers (diuresis, serum creatinin and/or cystatin C) have low diagnostic accuracy. The purpose of our study was to investigate the role of urinary Neutrophil GelatinaseAssociated Lipocalin (uNGAL) in the monitoring of kidney graft perfusion in the first 72 hrs post-KTx. Materials and methods: Consecutive children undergoing living related (LR) or deceased donor (DD) KTx, were prospectively enrolled between April 2010 and July 2011. uNGAL levels were quantified every 12 h by chemiluminescent microparticle immunoassay (CMIA, Abbott Architect). Urine samples were collected from a ureteral stent draining directly the transplanted kidney. uNGAL levels were correlated with the real-time values of renal regional oxygen saturations (rSO2) using nearinfrared spectroscopy (NIRS). Twenty-three children were included, 6 underwent LR-KTx and 17 DD-KTx. Median age at KTx was 9.2 yrs (range 1.6-17.8) and median weight was 20 kg (range 6.5-65). Results: Basal uNGAL values (ng/mL) were higher in DD-KTx (mean 765.82+931.73) compared with LR-KTx (301.88+363.49; p<0.05). A significant decreasing trend in uNGAL values was observed in both LR- and DD-KTx (121.36+124.99 vs 32.23+23.51 ng/mL respectively), 72 h post-transplantation. In all LR-KTx, uNGAL values were within the proposed normal range (<150 ng/mL) within 12 h after KTx. 71% and 28% of DD-KTx recipients, showed uNGAL levels above-normal at 12 and 72 h post-KTx (729.63+721.18 and 121.36+124.99, respectively). The trend of uNGAL levels showed a significant correlation with renal rSO2 both in DD-KTx (r=-0.96) and LR-KTx (r=-0.89). Conclusions: uNGAL is a reliable marker of renal ischemia. As its decreasing trend was significantly associated with an improvement in renal rSO2, uNGAL levels monitoring could became an useful non-invasive tool for the evaluation of kidney graft perfusion during the first hrs after transplantation, a tricky phase when an ischemic insult could benefit from prompt medical or surgical treatment. biochimica clinica, 2012, vol. 36, n. 6 541 44° Congresso Nazionale SIBioC - Riassunti Poster P141 URINARY SEDIMENT: AN ESSENTIAL ANALYSIS TO IDENTIFY THE OFTEN MISSED CYSTINURIA 1 1 1 P142 VALORI SIERICI DI γ-GLUTAMILTRANSFERASI (GGT) IN SOGGETTI CON ALTERATA FUNZIONE RENALE 1 D. Scribano , C. Rossi , S. Persichilli , J. Gervasoni , B. 2 1 Zappacosta , C. Zuppi G. Lobreglio, F. Sicuro, G. Capuano 1 U.O.C. Patologia Clinica, P.O. "Vito Fazzi", ASL LE, Lecce U.O.C. Analisi 1 Policlinico Universitario “A. Gemelli”Roma 2 *U.O.C. Laboratorio Analisi Fondazione di Ricerca e Cura "Giovanni Paolo II"- Campobasso Introduction: Cystinuria is an autosomal recessive disorder characterized by impairment of the proximal renal tubules which are unable to reabsorb cystine and dibasic amino acids, leading to the formation of recurrent kidney stones. Two types of cystinuria are known : A e B. Type A heterozygotes are generally asymptomatic while type B heterozygotes usually have a three-fold increased incidence of kidney stones compared to general population. Case report: A 46-year-old man was admitted to this hospital because of cardiac arrhythmia and syncope. The patient’s medical history included these episodes that occurred unpredictably and were unrelated to eating or physical activity and occasional episodes of renal colics controlled by himself with hyperhydration. All routine investigations ruled out cardiac pathologies, but the urinalysis (pH = 6.5) showed the presence of several cystine crystals. The determination of cystinuria showed a value above 300 μmol/mmol of creatinine, while the values of homocysteine (HCY), folic acid and vitamin B12 were within the normal range. The urinalysis was reapeted after a month and showed absence of cystine crystals and massive presence of amorphous urates (pH = 6.5) but the value of cystinuria was confirmed and HCY, folic acid and vitamin B12 were again within the normal range, so the clinic diagnosis of cystinuria was supposed. We made recommendation to the patient to carry out genetic investigation supporting the clinical diagnosis. Materials and methods: The urinary sediment (the second urine of the morning) was examined by Sedimax (Menarini), the urinary cysteine and homocysteine were determined by an HPLC-FL method, folic acid and vitamin B12 were determined by CMIA method (Architect PLUS Abbott). Conclusion: The analysis of the urinary sediment is a valuable tool for the diagnosis and monitoring of the diseases of the kidneys and the urinary tract, even if is mandatory to use the correct methodology and it is just a great help to identify the cystinuria often missed. 542 biochimica clinica, 2012, vol. 36, n. 6 Scopo: La γ-glutamiltransferasi è stato a lungo considerato un test di funzionalità epatica ed un marcatore di eccessivo uso di etanolo. Recenti studi epidemiologici hanno esteso lo spettro di condizioni cliniche associate ad un aumento della GGT, mentre non sono ancora del tutto i meccanismi fisiopatologici di queste associazioni. Lo scopo di questo studio è di valutare i livelli sierici di GGT in una popolazione ambulatoriale con alterazioni biochimiche di funzionalità o danno renale (organo molto ricco di strutture vasali). Materiali e metodi: Sono stati valutati 1800 soggetti afferenti all'ambulatorio di Patologia Clinica del nostro P.O. di età compresa tra 18 e 75 anni (960 maschi, 840 femmine) per i quali erano disponibili i valori di GGT, creatinina, eGFR, albuminuria, ALT, AST ed esame emocromocitometrico. La GGT e le transaminasi sono stati misurati con metodi enzimatici-colorimetrici e l'albuminuria con metodo turbidimetrico su analizzatori Roche/Modular P, l'esame emocromocitometrico è stato eseguito su analizzatori ematologici Sysmex, la eGFR (estimated glomerular filtration rate) è stata calcolata con l'equazione MDRD. Risultati: In 243 soggetti è stato riscontrato una alterata funzionalità e o segni biochimici di danno renale con 2 valori di eGFR < 60 mL/min/1,73 m superficie corporea e/o albuminuria < 30 mg/g creatininuria, in assenza di segni biochimici di danno epatico (valori di transaminasi nel range di riferimento) e di aumento di MCV all'esame emocromocitometrico. I valori di GGT sierici di questi soggetti erano statisticamente più elevati rispetto a quelli dei soggetti senza alterazioni della funzionalità renale: 87 ± 54 U/L vs 34 ± 29 U/L; p < 0,001. Discussione: Questo studio ha evidenziato valori più elevati di GGT in soggetti con alterazioni della funzione e/o segni biochimici di danno renale; i meccanismi fisiopatologici più verosimili dell'associazione di GGT con varie condizioni patologiche sono costituiti dalla deplezione del glutatione da parte di sostanze ossidanti che causa un incremento compensatorio di GGT e/o dalla produzione di radicali liberi dalle reazioni catalizzate da GGT. Pertanto, alti valori di GGT possono rappresentare non solo un marker di condizioni cliniche e/o precliniche, ma anche un fattore di rischio che contribuisce alla loro insorgenza ed evoluzione. 44° Congresso Nazionale SIBioC - Riassunti Poster P144 ANALISI MUTAZIONALE DEI GENI APOA1 E LPL NELLA SINDROME DA BASSE HDL P143 VALUTAZIONE DEL SISTEMA “ANALISI AD IMMAGINE” (SEDIMAX) PER LO SCREENING MICROBIOLOGICO 1 1 1 1 2 G. Covili Faggioli , M. Bove , P. Parisi , S. Ambretti , E. 2 1 1 Mirone , E. Di Somma , M.A. Laudadio , T.P. 1 1 1 1 1 Papillo , P. Selva , R. Venturi , E. Beltrandi , R. Motta 1 U.O. Lab. Centralizzato, Policlinico S. Orsola, Bologna U.O. di Microbiologia, Policlinico S. Orsola, Bologna 2 Scopo: Verificare la sensibilità dello strumento Sedimax Menarini Diagnostics nello screening delle infezioni delle vie urinarie, eseguito con la tecnologia "ANALISI AD IMMAGINE”, utilizzando il conteggio dei batteri. Materiali e metodi: Sono stati valutati 1689 campioni di soggetti adulti (1154 F; 535 M), selezionati presso la U.O. Microbiologia-Landini, per i quali era stato richiesto anche l’esame completo urine, eseguito su provetta dedicata presso l’U.O. Laboratorio Centralizzato-Motta. Su questi campioni è stato effettuato l’esame microbiologico con semina in piastra, mediante Seminatore Automatico “Chromagar orientation chima”. In seguito, nei campioni positivi, è stata effettuata l’identificazione biochimica del microrganismo, mediante strumentazione “Vitek 2 Biomerieux”, con successivo antibiogramma. Nei campioni positivi, è stata valutata, nell’esame completo urine, sia la presenza di batteri che dei leucociti, per escludere un eventuale inquinamento del campione stesso. I soggetti sono stati suddivisi in 4 categorie: positivi e negativi all’esame completo urine (cut off >80 num/uL), positivi e negativi all’esame colturale (cut off >10^5/mL), in maniera da poter applicare un Test non parametrico binomiale e verificare la significatività statistica tra le categorie. Risultati: Numerosità osservata con esame completo urine: 255 positivi (15%), 1434 negativi (85%). Numerosità osservata con esame colturale: 365 positivi (22%), 1324 negativi (78%). Il test statistico non parametrico applicato alle suddette categorie è risultato significativo (P <0.001). Conclusioni: Le ottime performance strumentali evidenziate dimostrano che l’utilizzo del sistema “ANALISI AD IMMAGINE” (Sedimax) sarebbe applicabile con grande vantaggio nello screening microbiologico delle urine, permettendo una significativa riduzione del turn around time per i campioni negativi. Si eviterebbe inoltre la prescrizione di terapie chemioantibiotiche empiriche e, si otterrebbe un sostanziale risparmio sui costi dell’urinocoltura. Zaman Z, Fogazzi GB, Garigali G, et al. Urine sediment analysis: Analytical and diagnostic performance of sediMAX-a new automated microscopy imagebased urine sediment analyser. Clin Chim Acta 2010;411:147-54. 2 1 2 G. Truglio , A. Montali , M. Lucarelli , E. Salvia , F. 3 2 1 Martino , M. Arca , R. Strom 1 Dip. di Biotecnologie Cellulari ed Ematologia, Sapienza Università di Roma 2 Dip. di Clinica e Terapia Medica, Sapienza Università di Roma 3 Dip. di Pediatria, Sapienza Università di Roma Le dislipidemie aterogene sono alterazioni del metabolismo lipidico associate ad elevato rischio cardiovascolare. La sindrome da basse HDL rientra in questo quadro di manifestazioni, con numerosi geni potenzialmente coinvolti. Ciò rende particolarmente complessa l’analisi mutazionale. In una casistica pediatrica di 84 bambini con valori di colesterolo HDL < 40 mg/dL, abbiamo preliminarmente effettuato l’analisi mutazionale di 2 geni candidati, quello per l’apoproteina A-I (APOA1) e quello per la lipoproteinlipasi (LPL). L’analisi mutazionale è stata condotta per sequenziamento mediante una piattaforma strumentale automatizzata in formato 96-well comprendente il sistema robotico Microlab Starlet (Hamilton), l’analizzatore genetico ABI PRISM 3130xl (Applied Biosystem) e il software SeqScape (Applied Biosystem) per l’analisi dei dati. Come popolazione di controllo è stata utilizzata quella del database EU SNP. Nel gene APOA1 sono state identificate le seguenti variazioni di sequenza: 1 nel promotore (-75G>A), 21 introniche (9 delle quali nuove) e 1 esonica (A188S). L’unica funzionalmente descritta è la -75G>A (ad elevata frequenza nella popolazione analizzata: 0.161, p<0.05 rispetto ai controlli) che sembra influenzare il tasso di trascrizione del gene ed è associata a bassi valori di HDL. Nel gene LPL sono state identificate le seguenti variazioni di sequenza: 1 al 5’UTR (-281T>G), 9 esoniche (N291S, L365V, D9N, S45N (nuova), R89Q (nuova), V108V, E118E, T106T, S447X) e 15 introniche. Le variazioni N291S, L365V, -281T>G e D9N (ad elevata frequenza complessiva nella popolazione analizzata: 0.233, le prime 2 p<0.01 rispetto ai controlli), sono state associate a fenotipi iperlipidemici con bassi livelli di HDL. La S447X (a bassa frequenza nella popolazione analizzata: 0.071, rispetto ai controlli 0.120, p=0.058), risulta associata ad un’aumentata attività della LPL, con bassi valori di trigliceridi nel siero e diminuito rischio cardiovascolare. Un approccio sperimentale di ricerca mutazionale ad alta produttività risulta indispensabile per la caratterizzazione genetica di questa sindrome. La selezione di numerose variazioni di sequenza non precedentemente caratterizzate funzionalmente, pone il problema della corretta individuazione di un loro significato clinico. biochimica clinica, 2012, vol. 36, n. 6 543 44° Congresso Nazionale SIBioC - Riassunti Poster P145 DELEZIONE DEL BRACCIO LUNGO DEL CROMOSOMA Y IN UN SOGGETTO CON RITARDO MENTALE 1 1 P146 DETERMINAZIONE DEGLI STEROLI PLASMATICI ED ERITROCITARI DI PAZIENTI AFFETTI DA DIFETTI DELLA BIOSINTESI E DEL METABOLISMO DEL COLESTEROLO 1 S. Egiziano , V. Mavaracchio , F. Donà , L. 1 1 2 2 Tognetto , A. Brugnoli , E. Stathaki , S. Gimelli , F. 2 3 1 Sloan Béna , F. Garonna , L. Bartoloni R. Barone , M. Gelzo , S. Clericuzio , G. Corso , A. 1 Dello Russo 1 1 ULSS12 Veneziana, Dipartimento di Patologia Clinica, Venezia 2 Service de Genetique Medicale, HUG, Geneve 3 ULSS12 Veneziana, Dipartimento di Salute Mentale, Venezia È stato analizzato il caso di un signore di 40 anni valutato per ritardo mentale di grado medio con episodi di esibizionismo sessuale. L’analisi citogenetica classica ha evidenziato una delezione a carico del braccio lungo del cromosoma Y [46,XY, del(Yq)]. Tale alterazione è stata confermata mediante l’utilizzo di due kit diversi per l’analisi delle microdelezioni del cromosoma Y, entrambe basate su tecnica di PCR multiplex ed elettroforesi su gel di agarosio (Y Chromosome AZF Analysis System, Promega e AZF- MX, AB Analitica). La delezione inizia tra SY117 (presente) e SY121 (assente) e si estende fino ai telomeri, la cui assenza è stata confermata mediante ibridazione in situ fluorescente (FISH). La delezione comporta l’assenza di gran parte della regione AZFb e la totale mancanza della regione AZFc e dei geni a valle. Mediante ibridazione genomica comparativa su microarray (Agilent 44K) è stata esclusa la presenza di ulteriori grandi delezioni o inserzioni. È noto che nel tratto deleto sono situati geni implicati nella spermatogenesi. Dai risultati ottenuti possiamo quindi ipotizzare una probabile sterilità del paziente. Lo spermiogramma è in corso mentre i dosaggi ormonali sono: FSH 40 UI/L (Val. rif.: 1-20 UI/L); LH 8 UI/L (Val. rif.: 1-10 UI/L); 17-betaEstradiolo (E2) < 20 ng/L (Val. rif.: < 50 ng/L); Prolattina 15 mcg/L (Val. rif.: 3-15 mcg/L) e Testosterone 2,7 mcg/ L (Val. rif.: 1,7-8 mcg/L). Sono invece rarissimi i casi riportati in letteratura di ritardo mentale o disturbi psichici in pazienti con delezione del braccio lungo del cromosoma Y e il gene direttamente responsabile non è stato ancora identificato. Tyson C, Dawson AJ, Bal S, et al. Molecular cytogenetic investigation of two patients with Y chromosome rearrangements and intellectual disability. Am J Med Genet A 2009;149A:490-5. 544 biochimica clinica, 2012, vol. 36, n. 6 1 1 1 2 Dipartimento di Biochimica e Biotecnologie Mediche, Università Federico II, Napoli 2 Dipartimento di Medicina Clinica e Sperimentale, Università degli Studi di Foggia Introduzione: In questo lavoro riportiamo la nostra esperienza sulla diagnosi dei difetti congeniti della biosintesi e del metabolismo del colesterolo (CHOL). Tali difetti causano complessi quadri clinici caratterizzati da malformazioni multiple, ritardo mentale e di crescita e nei casi più gravi, morte intrauterina. La sindrome di SmithLemli-Opitz (SLOS) rappresenta il prototipo di tali difetti ed è causata dal deficit dell’enzima 7-deidrocolesterolo reduttasi con accumulo nel sangue e nei tessuti del 7deidrocolesterolo e dell’isomero 8-deidrocolesterolo. Metodi: Mediante la gascromatografia accoppiata alla spettrometria di massa è stato determinato il profilo completo degli steroli nel plasma e nelle membrane eritrocitarie (EM) di pazienti con sospetto clinico di difetto della biosintesi del CHOL, utilizzando un metodo già standardizzato. Risultati: I valori di riferimento degli steroli plasmatici, ottenuti in 364 soggetti non affetti, sono in accordo con quelli riportati in letteratura. Tra i pazienti investigati dal 2005 ad oggi, riportiamo i dati di 20 pazienti affetti da SLOS, di cui 7 rappresentavano nuovi casi e 13 erano pazienti in follow-up. Inoltre, nello stesso periodo abbiamo identificato un nuovo caso di condrodisplasia punctata Xlinked ed uno di xantomatosi cerebrotendinea. L’incidenza dei casi SLOS è risultata pari a 1 su 53 pazienti sospetti (1.89%). Inoltre abbiamo valutato l’influenza del tempo di conservazione sul rapporto deidrocolesteroli/ colesterolo (DHC/CHOL) nei campioni di plasma e di EM di pazienti SLOS conservati a -20 °C per 22 e 20 mesi, rispettivamente. I risultati hanno mostrato una significativa correlazione lineare negativa tra il tempo di conservazione ed il rapporto DHC/CHOL sia nel plasma che nelle EM. La riduzione del rapporto DHC/CHOL nei campioni di EM era almeno due volte maggiore rispetto al plasma. Conclusioni: I risultati di questo studio possono essere utili per la diagnosi e l’interpretazione dei dati ottenuti in pazienti con quadro clinico suggestivo di un difetto della biosintesi e del metabolismo del CHOL. Corso G, Gelzo M, Barone R, et al. Sterol profiles in plasma and erythrocyte membranes in patients with Smith-Lemli-Opitz syndrome: a six-year experience. Clin Chem Lab Med 2011;49:2039–46. 44° Congresso Nazionale SIBioC - Riassunti Poster P147 DETERMINAZIONE DELL'ASSETTO EMOGLOBINICO AL PRIMO LIVELLO DIAGNOSTICO: RILEVANZA DELLO STUDIO FAMILIARE 1 1 2 3 M. Mercadanti , A. Caleffi , S. Moretti , S. Bigoni , A. 3 1 Ravani , G. Lippi 1 U.O. Diagnostica Ematochimica, Az. OspedalieroUniversitaria, Parma 2 U.O. Neonatologia e terapia intensiva neonatale, Az.Ospedaliero-Universitaria, Parma 3 U.O. di Genetica Medica, Az. Ospedaliera Universitaria, Ferrara Il fenomeno migratorio che da anni interessa il nostro paese ha modificato il tradizionale scenario delle emoglobinopatie della popolazione autoctona, con casi complessi, talvolta di difficile identificazione da parte del laboratorio di primo livello. Riportiamo il caso di un neonato, pretermine, nato alla 23° settimana, di origine nigeriana, per il quale era richiesto l’assetto emoglobinico, essendo i genitori portatori rispettivamente di HbS e HbC. Lo screening in HPLC (Variant II, Bio-Rad) evidenziava un picco anomalo del 9.6%, ad eluizione veloce ed un picco pari all’1.7% eluente in posizione C. L’elettroforesi alcalina confermava la presenza di una banda in zona C ed una in zona J, l’elettroforesi acida rilevava una banda in zona C ed una in zona prossima ad F. Nel sospetto di emoglobinopatia Hb Bart’s e HbC si consigliava rivalutazione dopo il secondo mese di età corretta. Il controllo ad un anno evidenziava un quadro compatibile con eterozigosi HbC (Hb A= 65.5%, Hb F=5.6%, A2=3.2%, Hb C=25.7%). La bassa percentuale della Hb C, in presenza di microcitosi ed ipocromia (MCV=58 fl; MCH=19.8 pg), con sideremia nei limiti, induceva il sospetto di un concomitante difetto dei geni alfa, per cui, nel referto interpretativo, si consigliava approfondimento al secondo livello diagnostico. Con la collaborazione della pediatra sono stati recuperati i referti delle analisi molecolari eseguite in occasione delle precedenti gravidanze della coppia, presso la UO di Genetica, AOU di Ferrara, da cui emergeva: per la madre eterozigosi per HbS e per la delezione alfa talassemica del tipo–alfa 3.7 e per il padre omozigosi per HbC e per la delezione alfa talassemica del tipo –alfa 3.7. Alla luce di questi dati si concordava con la pediatra di non proseguire con gli accertamenti ritenendo verosimile per il neonato un difetto talassemico di uno o due geni alfa, responsabile della microcitosi. Dati i genotipi parentali era esclusa la delezione di tre geni, come supportato dall’assenza di Hb H. E’ importante disporre di cromatografi che rilevino percentuali anche minime di componenti anomale. La consulenza genetica, la collaborazione con la pediatra e l’integrazione delle informazioni hanno permesso di evitare un inutile ricorso a costose indagini molecolari. P148 EFFICACY OF THE ALPHA-1-ANTITRYPSIN DEFICIENT VARIANTS DETECTION BY SEMIAUTOMATED SEBIA ISOELECTROFOCUSING PHENOTYPING AND THE NEED FOR A RE-EVALUATION OF REFERENCE AND INTERPRETATIVE RANGES FOR ALPHA-1ANTITRYPSIN QUANTITATION 1 1 1 1 M. Scarpellini , D. Ricotta , L. Piccioni , M. Borghesi , I. 1 2 3 4 Bianchi , L. Corda , N. Gatta , D. Medicina , L. 1 1 Caimi , I. Zanella 1 Laboratorio Analisi Chimico-Cliniche, A.O. Spedali Civili, Brescia-Sezione di Biochimica e Biochimica Clinica, Facoltà di Medicina, Università di Brescia 2 Medicina Generale 1, A.O. Spedali Civili, Brescia 3 Associazione Nazionale ALFA1-AT, Sarezzo, Brescia 4 Prima Anatomia Patologica, A.O. Spedali Civili, Brescia Alpha-1-antitrypsin (A1AT) is a serum protein that diffuses in the lungs and inhibits neutrophil elastase preventing alveolar elastine degradation. A1AT locus is extremely polymorphic: in addition to the native M allele, more than 100 variants have been identified. Several deficiency alleles have been described. Z and S alleles account for the majority of pathological mutations. A1AT deficiency is a genetic codominant condition that increases the risk of developing lung and liver diseases and rarely panniculitis and vasculitis. Early identification of at risk subjects is crucial since disease progression can be slowed by therapy and minimizing exposure to environmental agents. However the disorder is largely under-recognized due to the fact that many AAT deficient individuals do not have clinical manifestations until the age of 40-50. Although the deficiency can result in a disease state in homozygous ZZ, compound heterozygous SZ or nullmutations harbouring subjects several data suggest that people with even only one Z allele may be at risk in the case of other liver or lung insults. Laboratory evaluation of A1AT deficiency involves serum measurement by nephelometry and characterization by phenotyping or genotyping. The normal range of serum levels is reported between 200/220 and 80/120 mg/dL. However the cutoff value below which it might be useful to evaluate the phenotype/genotype is still a matter of debate. The main purposes of the present study were: 1-to evaluate a semi-automated protocol (Sebia IEF) as a diagnostic tool to identify deficient phenotypes; 2-to establish phenotype interpretation efficacy comparing the results with genotype whenever possible; 3-to ascertain the phenotype in different patients: patients with serum levels of A1AT below the cut-off value of 80-120 mg/dL, subjects identified as heterozygous by serum electrophoresis evaluation and subjects with low alpha 1 globulin fraction at serum protein electrophoresis. Our results confirm the efficacy of Sebia phenotyping protocol in identifying the main deficient S and Z alleles. We also confirm the necessity to use higher serum level cut-off for selecting subjects for phenotyping/genotyping to minimize the risk of missing subjects susceptible to A1AT deficiency related manifestations. biochimica clinica, 2012, vol. 36, n. 6 545 44° Congresso Nazionale SIBioC - Riassunti Poster P149 INTRA- AND EXTRACELLULAR FOLATE LEVELS IN A PATIENT AFFECTED BY HEREDITARY FOLATE MALABSORPTION (HFM) AFTER DIFFERENT FOLINIC ACID POSOLOGY: A BIOCHEMICAL EVIDENCE FOR CLINICAL THERAPY IMPROVEMENT 1 1 2 2 G. Canu , R. Penitente , I. Russo , A. Ruggiero , P. 2 1 1 1 Maurizi , C. Zuppi , A. Minucci , B. Giardina , E. 1 Capoluongo 1 Laboratory of Clinical Molecular Diagnostics, Institute of Biochemistry and Clinical Biochemistry, Catholic University of Rome, Italy 2 Institute of Pediatrics, Catholic University of Rome, Italy Background: Folate is an essential nutrient involved in a range of one-carbon metabolic reactions. Serum concentrations are commonly measured to assess the folate status, while erythrocyte (RBC) concentrations considered the best way for the measure of usual or longterm status. Folate supplementation increases serum and RBC folate concentrations. However, the duration of supplementation required for RBC folate concentrations to reach a new steady state is uncertain. HFM is characterized by folate deficiency with impaired intestinal folate absorption and impaired folate transport into the central nervous system. Herein, we report the folate status [serum, RBC and cerebrospinal fluid (CSF)] in a one year old female suffering from HFM after different folate treatment protocols in order to evaluate the optimal therapy. Methods: Patient underwent to folinic acid administrations [oral, intravenous (IV) and intramuscular doses (IM)]. After 5 mg IV or IM administrations, 5 serial blood samples and 2 CSF samples were collected. 24 days after, patient underwent to IM administration (5mg). After one week, one more blood sample was collected. For two weeks, patient underwent to three IM administrations (5mg/dose). At the end of each week a blood sample was collected. Samples were analyzed on Architect® Abbott using Architect® Folate kit. For the RBC folate assay, an manual pre-treatment step was required. Results: After oral folinic acid administration, serum folate levels remained under cut-off. Folate IV-treatment restored the normal folate levels in serum and RBCs for 22 days, and determined also an increasing of the CSF folate levels. Contrastingly, 6 days after the single IM administration, serum and RBC folate concentrations decreased, while after 3 IM administrations/week normal levels were restored. Discussion: For steady-state folate concentrations, IV administration is optimal but invasive. For this reason, an IM treatment (3 folinic acid administration/week) may be used as alternative since it maintained stable the folate concentrations in serum and RBCs. These results may indicate that different routes of folate absorption may exist at gastrointestinal and peripheral levels. 546 biochimica clinica, 2012, vol. 36, n. 6 P150 POSSIBILITA’ DIAGNOSTICHE DEL LABORATORIO DI 1° LIVELLO PER I DIFETTI STRUTTURALI DELL’EMOGLOBINA 1 1 2 2 G. Barberio , L. Caberlotto , D. Leone , A. Citana , G. 2 Ivaldi 1 U.O.Medicina di Laboratorio, Ospedale Cà Foncello, Treviso 2 Laboratorio di Genetica Umana, Ospedali Galliera, Genova Al centro del percorso diagnostico di laboratorio che porta ad individuare o ad escludere la presenza di un difetto dell’emoglobina (Hb) troviamo la valutazione quali-quantitativa delle frazioni dell’emoglobina (Hb)e le recenti Raccomandazioni per il laboratorio di 1°livello della Società Italiana per lo studio delle Talassemie ed Emoglobinopatie (SITE) hanno ribadito tale concetto. Materiali e metodi: Il nostro recente confronto tra metodi separativi diversi, al fine anche di avvalorare i concetti espressi dalle Raccomandazioni SITE, si è basato sull’analisi di 210 campioni anonimizzati e per i quali era stato ottenuto il consenso all’approfondimento diagnostico. Questi campioni sono stati esaminati in HPLC mediante tre diversi sistemi (8160-Menarini, Variant II-BioRad, G8-Tosoh) e in CE (Capillarys 2 Analyzer – Sebia). Risultati: Abbiamo ottenuto buoni risultati nella quantificazione dell’HbA2 e dell’HbF da tutte le strumentazioni utilizzate. Nella separazione delle varianti Hb, sia per le più comuni e frequentemente riscontrate sia per quelle più rare, i quattro sistemi hanno rivelato comportamenti differenti in alcuni casi. L’aspetto rilevante, e ben messo in evidenza dalle Raccomandazioni SITE, è rappresentato però dal fatto che non può essere un unico metodo separativo a consentire una diagnosi definitiva dei difetti strutturali dell’Hb. Associando un metodo cromatografico con uno elettroforetico e altri eventuali test biochimici specifici si sono così potute concludere, per i campioni esaminati, tutte le diagnosi relative alle quattro varianti più frequenti (Hb S, C, E e Hb Lepore), senza dover ricorrere all’analisi molecolare. Conclusioni: Si ritiene pertanto che qualora un laboratorio sia in grado di affrontare, in presenza di varianti Hb, alcuni esami di conferma in un ambito non molecolare (livello intermedio) possa proficuamente utilizzare i metodi HPLC abbinati all’elettroforesi capillare per una conclusione definitiva nel 93% dei casi che normalmente si possono presentare al laboratorio di 1° livello. Avere la possibilità di poter giungere ad una conclusione diagnostica non presuntiva, senza dover ricorrere sempre all’analisi molecolare può costituire un modo per contenere significativamente la spesa sanitaria. 44° Congresso Nazionale SIBioC - Riassunti Poster P151 ANALISI RETROSPETTIVA DEI VALORI DI IGF1 IN PAZIENTI PEDIATRICI E ADULTI 1 2 2 2 S. Suppressa , M. Brugia , F. Balducci , V. Scocco , M. 2 Tocchini 1 Patologia clinica Università di Bologna 2 Laboratorio Biochimica Clinica e Microbiologia Azienda Ospedali Riuniti Ancona Premesse: Il dosaggio di IGF1 è largamente utilizzato nella diagnosi dei disordini della secrezione dell’ormone della crescita (GH) e nel follow-up dei pazienti in terapia. L’introduzione del metodo automatizzato in chemiluminescenza (standard WHO 87/518) ha apportato delle modifiche rispetto ai metodi radioimmunometrici precedentemente utilizzati in termini di appropriatezza diagnostica e range di riferimento. Scopo del lavoro è stato quello di valutare, nella nostra popolazione, la distribuzione dei valori di IGF1 per fasce di età e per genere e confrontarle con quelle suggerite dalla letteratura scientifica. Materiali e metodi: Tra l’1/01/2008 e 1/06/2012 sono stati esaminati 9778 campioni di siero afferenti al laboratorio dai reparti interni e dagli Ospedali di tutta la regione Marche. Il dosaggio dell’IGF1 è stato effettuato mediante metodo chemiluminescente (Immulite 2000 Siemens sensibilità 20ng/mL). La popolazione è stata suddivisa in 2 gruppi: il primo tra 0-20 anni è stato studiato in dettaglio, mentre il secondo (21-100 anni) è stato suddiviso per fasce d’età di 5 anni. L’analisi statistica è stata effettuata mediante SPSS. Risultati: Nei pazienti al di sotto dell’anno di età la mediana del dosaggio dell’IGF-1 è stata pari a 45 ng/mL. Tale valore aumenta gradatamente fino all’età di 15 anni (397 ng/mL) per poi decrescere fino a 20 (253 ng/mL). Tali mediane, soprattutto nella fascia di età tra 6-11 anni, mostrano un andamento diverso tra maschi e femmine. Tra 21-100 anni si nota poi un progressivo decremento dei valori di IGF-1 fino a 98 ng/mL. Conclusioni: Dall’elaborazione dei dati, si evidenzia che l’IGF-1 presenta una distribuzione ben distinta per fasce d’età e sesso e presenta una buona correlazione con i range suggeriti dalla letteratura scientifica, sebbene si pone la necessità di rivedere gli intervalli di normalità per migliore l’efficacia del test nella pratica clinica soprattutto nei primi 20 anni. Chaler EA, Meazza C, Guercio G, et al. Serum IGF-I and IGFBP-3 reference values from a chemiluminescent assay in normal children and adolescents of hispanic and italian origin: presence of sexual dimorphism in IGF-I values. J Pediatr Endocrinol Metab 2009;22:1127-35. P152 CLINICAL UTILITY OF ANTI-MÜLLERIAN HORMONE ON THE EVALUATION OF FERTILITY PRESERVATION IN YOUNG FEMALE PATIENTS AFTER TREATMENT FOR HEMATOLOGICAL MALIGNANCY 1 2 2 G.L. Salvagno , R. Di Paola , S. Zaffagnini , M. 1 2 3 2 Gelati , A. Perandini , C. Tecchio , C. Costantini , R. 2 2 1 Montemezzi , M. Franchi , G.C. Guidi 1 Sez. di Biochimica Clinica , Dip. di Scienza della Vita e della Riproduzione, Univ. di Verona 2 Sez. di Ostetricia e Ginecologia, Dip. di Scienza della Vita e della Riproduzione, Univ. di Verona 3 Sez. di Ematologia, Dip. di Medicina, Univ. di Verona Background: The new advances in the treatment of cancer have greatly increased the life expectancy of premenopausal women with haematological malignancies.The susceptibility of the ovarian reserve to chemotherapy is highly variable from one patient to another. Anti-Mullerian hormone (AMH), has been shown to be one of the most sensitive markers of ovarian reserve and fertility preservation. Aim: To better characterize the evolution of fertility preservation, based antral follicle counts (AFC), serum anti-Müllerian hormone (AMH) assay, follicle stimulating hormone (FSH), and inhibin B were assayed in female patients treated for lymphoma and leukemia. Materials and methods: 63 consecutive women diagnosed with a hematological disease (48 with Hodgkin's lymphoma; 9 Non Hodgkin's lymphoma; 6 acute myeloid leukemia) were eligible for enrolment. All patients [median age 31 yr (range 17-40 yr)] were in complete remission with a median follow-up time of 9.0 yr after therapy. 64 normal controls were also evaluated [median age 31 yr (range 20-42 yr)]. Participants had a baseline blood drawing during the early follicular phase of the menstrual cycle for AMH, FSH, and inhibin B measurements. Antral follicle counts (AFC) were performed by transvaginal ultrasonography on menstrual cycle day 2. Serum levels of AMH and inhibin B were determined using AMH Gen II Elisa assay and Inhibin B Gen II ELISA (Beckman Coulter) respectively, both assessed on a Triturus® EIA Analyzer (Grifols). FSH was performed by using an automated chemiluminescence assay system (Immulite 2000®, Siemens). Results: A significant variation of AFC [9.8 vs 16.0, p<0.005)], AMH [2.02 ng/mL vs 2.97 ng/mL, p<0.05], FSH [16.9 mU/mL vs 8.1 mU/mL, p<0.05] and inhibin B [33.7 ng/L vs 69.4 ng/L, p<0.005] were observed by KruskalWallis one-way analysis of variance between patients and controls. The ROC curve analysis comparing AMH and FSH values of patients (at the same AFC cut-off point of 8) revealed that AMH had a better area under the curve (AUC)(0.904; p=0.005) than FSH (0.678; p=0.005). Conclusions: Ovarian reserve is reduced in female patients affected by lymphoma. AMH is the most reliable serum marker of fertility preservation outcomes, together with AFC as a biophysical marker, in girls receiving treatment for cancer. biochimica clinica, 2012, vol. 36, n. 6 547 44° Congresso Nazionale SIBioC - Riassunti Poster P154 DEFINIZIONE DEL LIMITE DI RILEVAZIONE (LOD) DEL [-2]PROPSA IN VISTA DI UN SUO POSSIBILE UTILIZZO COME INDICATORE PRECOCE DI RECIDIVA DEL TUMORE PROSTATICO P153 CORRELATION OF SERUM CYSTATIN C WITH GLOMERULAR FILTRATION RATE IN PATIENTS RECEIVING PLATINUM-BASED CHEMOTHERAPY V. Barchiesi, S. Cecere, D. Cerasuolo, M. Di Maio, F. Di Paola, S. Pignata, E. Cavalcanti Istituto Nazionale Tumori - IRCCS, Fondazione G. Pascale, Napoli We measured serum concentrations of cystatin C and creatinine and calculated Glomerular Filtration Rate (GFR, Cockcroft-Gault equation) in a series of cancer patients (pts), before and during platinum-based chemotherapy. Serum creatinine, cystatin C, and GFR were determined simultaneously in all pts, before the first cycle and before subsequent administrations. Pearson correlation coefficients (r) were calculated. To assess the diagnostic accuracy of serum cystatin C in predicting 2 2 GFR<80 mL/min/1.73m and GFR<60 mL/min/1.73m , ROC (receiver operating characteristics) plots were performed (pROC package for R), calculating the area under the curve (AUC) and 95% confidence interval (CI). Overall, 31 patients were studied (7 males and 24 females), 18 receiving carboplatin-based and 13 cisplatinbased chemotherapy. Overall, 155 measurements were performed (range 1 – 12 per patient, 37 in males, 118 in females). Median baseline cystatin value was 1.39 mg/l (range 0.75–1.94). Median baseline GFR 2 was 87.8 mL/min/1.73m . Out of 31 pts, 14 had a baseline GFR<80: all 14 pts had a baseline cystatin > upper normal limit, whilst serum creatinine value was within normal range in 13 (93%). Of pts starting treatment with baseline normal GFR, 2 pts subsequently developed GFR<80, both with high baseline cystatine and normal creatinine value. In the overall series, linear regression showed a significant relationship (p<0.001) between GFR and concomitant value of serum cystatin C (r=0.56). The relationship was statistically significant in both males and females, but r coefficient was higher in females (0.62 vs 0.43 in males). In the overall series, for GFR<80, the AUC of ROC curve for cystatin was 79.5% (95%CI 72.6%–86.5%). The best threshold was 1.285 mg/L (sensitivity 83.3%, specificity 60.2%, negative predictive value 84.8%, positive predictive value 57.5%). AUC was 81.2% (95%CI 73.6% – 88.8%) and 74.5% (95%CI 57.1%–91.9%) in females and males, respectively. For GFR<60, the AUC for cystatin was 88.0% (95%CI 81.0%–94.9%). The best threshold was 1.62 mg/L (sensitivity 81.8%, specificity 81.7%, negative predictive value 96.4%, positive predictive value 42.9%). The AUC for cystatin was 88.6% (95%CI 80.8%–96.5%) and 88.5% (95%CI 73.9%–100%) in females and males, respectively. 548 biochimica clinica, 2012, vol. 36, n. 6 1 1 1 2 F. Ceriotti , M. Pontillo , L. Fasoli , M. Lazzeri , G. 2 2 2 3 Lughezzani , G. Lista , A. Larcher , G. Fuzzi , G. 2 Guazzoni 1 Diagnostica e Ricerca San Raffaele, Istituto Scientifico Ospedale San Raffaele, Milano 2 Dipartimento di Urologia, Ospedale San Raffaele Turro, Università Vita-Salute San Raffaele, Milano 3 Istituto Ricerche Cliniche “M. Fanfani”, Firenze Introduzione: Il [-2]proPSA è una molecola che si genera nella prostata durante la sintesi del PSA e passa in circolo in quantità più elevata in presenza di tumore prostatico. Data la sua maggiore specificità per la diagnosi precoce di tumore rispetto al PSA totale si potrebbe ipotizzare una sua utilità anche nell’individuazione precoce di recidive dopo la prostatectomia totale. Scopo del lavoro è la valutazione della possibilità tecnica di questo utilizzo verificando il limite di rilevazione (LoD) della molecola. Materiali e metodi: Sono stati utilizzati campioni residui da prelievi di 10 pazienti con recidiva biochimica e patologica di Ca prostatico, dopo prostatectomia radicale. I campioni sono stati diluiti con pool di sieri di soggetti di sesso femminile con PSA totale non misurabile e portati ad una concentrazione di PSA totale pari a circa 0.2 ng/ mL (valore che definisce una ripresa di malattia dopo prostatectomia radicale). I campioni diluiti sono stati aliquotati, congelati a -80 °C ed il [-2]proPSA è stato misurato in duplicato in 5 diverse giornate. Seguendo il documento CLSI EP 17-A il LoD è stato poi calcolato secondo la formula seguente: LoD = limite del bianco (LoB) + Cß x DS cumulativa (dove Cß è il 95° percentile della distribuzione Gaussiana standard corretto = 1.645/ (1-1(4 x f) [f = gradi di libertà = 90]). Risultati: I valori di [-2]proPSA nei campioni diluiti dei 10 soggetti sono risultati compresi tra 0.73 e 3.67 pg/mL con una DS cumulativa pari a 0.1979 pg/mL. Come limite del bianco si è utilizzato il valore fornito dalla ditta (0.5 pg/mL). In queste condizioni il LoD è risultato 0.8 pg/mL. Discussione: Il valore di LoD ottenuto è tale da prospettare la possibilità di utilizzo della misura del [-2]proPSA come marcatore precoce di recidiva dopo prostatectomia totale per Ca prostatico. Sarà ora necessario verificare se questa applicazione potrà dare vantaggi clinici rispetto alla misura del PSA totale. 44° Congresso Nazionale SIBioC - Riassunti Poster P155 DETERMINAZIONE DEL TESTOSTERONE SIERICO: CONFRONTO TRA METODO IMMUNOMETRICO E HPLC-MS/MS 1 1 1 2 C. Artusi , M. Marinova , L. Brugnolo , G. Antonelli , M. 1 1 Zaninotto , M. Plebani 1 UOC Medicina di Laboratorio, Azienda OspedalieraUniversità degli Studi, Padova 2 Dip. di Medicina, Università degli Studi di Padova Introduzione: La sindrome dell’ovaio policistico (PCOS) è uno dei più comuni disordini ormonali nelle donne, essendo presente nel 5-10% delle donne in età fertile e rappresenta una delle più comuni cause di infertilità. Attualmente la diagnosi di PCOS richiede anche la determinazione dei livelli sierici totali di testosterone (Te). La letteratura scientifica evidenzia come i numerosi metodi analitici utilizzati siano altamente imprecisi ed innacurati con conseguente mancanza di standardizzazione. Obiettivi: Confrontare il sistema diagnostico immunometrico in uso nella nostra routine con un metodo HPLC-MS/MS per la determinazione del testosterone sierico nelle donne. Materiali e metodi: Sono stati raccolti 123 campioni di siero di pazienti donne afferenti al Servizio Medicina di Laboratorio con richiesta di testosterone sierico. Tutti i campioni sono stati analizzati con un metodo in immunochemiluminescenza (ECLIA) sullo strumento Modular E170 (Roche Diagnostics) e con un metodo HPLC-MS/MS a triplo quadrupolo (Agilent Technologies). I risultati sono stati elaborati statisticamente con Analyseit® Software (Ltd, Leeds, UK). Risultati: I due metodi, messi a confronto attraverso la regressione lineare e l’analisi di Bland-Altman, 2 presentano una buona correlazione (R =0.80, y=0.9224x +0.2758) e un bias statisticamente non significativo nel range di concentrazioni 0.08-6.70 nmol/L. Anche nella valutazione del limite di quantificazione (ECLIA LOQ=0.120 nmol/L vs HPC-MS/MS LOQ=0.165 nmol/L) e dell’imprecisione analitica (ECLIA CV=5.3% vs HPCMS/MS CV=5.9%) i due metodi presentano entrambi prestazioni adeguate alla diagnostica di PCOS. Conclusioni: Il metodo immunometrico attualmente in uso nella nostra routine ha mostrato una buona correlazione con il metodo di riferimento, universalmente riconosciuto, HPLC-MS/MS (sviluppato e validato). I dati ottenuti confermano quindi che il metodo ECLIA applicato su Modular E-170 è analiticamente affidabile per la determinazione del testosterone sierico nelle donne come segnalato dal programma di standardizzazione degli ormoni del Center of Disease Control and Prevention. P156 DIFFERENTI ISOTIPI DI GAMMOPATIE MONOCLONALI IN UNA SERIE DI 1187 CASI A. Frezzotti, M. Galeazzi, C. Paladini, R. Mazzoni, G. Pennesi, M. Tocchini Lab. Analisi, Ospedali Riuniti, Ancona Introduzione: In laboratorio è frequente il riscontro di una gammopatia monoclonale la cui prevalenza è più frequente nelle persone anziane. Descriviamo le caratteristiche delle componenti monoclonali (CM) osservate in un periodo di tre anni. Materiali e metodi: Negli anni 2009-2011 sono stati studiati i campioni di 1187 pazienti (678 maschi e 509 femmine) che presentavano per la prima volta anomalie del tracciato elettroforetico (Capillarys-Sebia) identificate come CM alla immunofissazione su gel di agarosio (Hydrasys-Sebia). E’ stata calcolata la frequenza delle gammopatie monoclonali e biclonali e dei diversi isotipi di CM. E’ stata valutata la differenza tra gruppi per età e sesso. Risultati: In 1133 pazienti (95,45%) era presente una CM; i maschi erano 640 (56,49%) con età di 67±12,7 e le femmine 493 (43,51%) con una età di 68±12,9; il 50% dei pazienti sia maschi che femmine avevano più 70 anni. La CM in 747 casi (62,90%) era di tipo IgG, in 203 (17,10%) IgM, in 203 (12,22%) IgA, in 3 (0,25%) IgD; in 32 casi (2,70%) erano presenti solo catene leggere e in 3 (0,25%) solo catene pesanti. In 54 pazienti (4,55%), 38 (70,4%) maschi con età 69,7±14,4 e 16 (29,6%) femmine con età 66,3±14,8 era presente una doppia CM; il 50% aveva più 73 anni. Le CM erano in 13 casi (1,09%) IgG-IgG, in 17 (1,43%) IgG- IgM, in 10 (0,84%) IgG IgA, in 7 (0,59%) IgAIgM e in 7 (0,59%) IgM-IgM. Nelle gammopatie con una CM le catene leggere erano di tipo κ in 685 casi (60,60%) e di tipo λ in 445 casi (39,40%). Nelle gammopatie con doppia CM erano presenti catene leggere dello stesso tipo κ o λ in 22 casi (40,74%) e catene leggere di tipo sia κ che λ in 32 casi (59,26%). Nei maschi la frequenza di doppia CM rispetto ad una CM era significativamente più elevata (p=0,04) senza differenza per l’età. Per i diversi isotipi di CM non si osservava nessuna differenza significativa né per età né per sesso. Conclusioni: La ripartizione dei diversi isotipi e la frequenza di doppia CM risultano simili ai dati riportati in letteratura. Lo studio delle frequenze ha evidenziato che la presenza di doppia CM è più elevata nei maschi. Decaux O, Rodon P, Ruelland A, et al. Epidemiology of monoclonal gammopathy in a general hospital and a university internal medicine department. Rev Med Interne 2007;28:670-6. biochimica clinica, 2012, vol. 36, n. 6 549 44° Congresso Nazionale SIBioC - Riassunti Poster P157 ESPERIENZA DI UTILIZZO DI HE4 E CA125 NELLA DIAGNOSTICA DEL CARCINOMA OVARICO EPITELIALE 1 1 1 1 L. Bani , F. Cappellini , R. Falbo , M. Bertona , P. 2 Brambilla 1 Servizio Universitario di Medicina di Laboratorio, A. O. di Desio e Vimercate, Desio (MB) 2 DIMS, Università degli Studi di Milano - Bicocca, Monza (MB) Introduzione: HE4 è una glicoproteina espressa in elevate concentrazioni nel siero di pazienti affetti da carcinoma ovarico epiteliale (EOC); grazie a queste caratteristiche HE4 è stato proposto come marker complementare a CA125. Scopo: Verificare le performance diagnostiche di HE4 nella diagnosi del carcinoma ovarico rispetto a CA125 e valutare l’algoritmo ROMA. Materiali e metodi: Nel periodo compreso tra Agosto 2011 e Marzo 2012 sono stati raccolti 132 campioni di siero su cui è stata determinata la concentrazione di HE4 tramite dosaggio immunoenzimatico su BEP 2000 (Siemens). 99 delle 132 donne presentavano anche contemporaneo dosaggio di CA125 eseguito su Modular (Roche). Ai fini dello studio sono state incluse sole le 99 pazienti con entrambi i dosaggi le quali sono state classificate in 4 categorie: nessuna patologia o patologie non tumorali, tumori benigni, tumori maligni e carcinoma ovarico. Risultati: 42 sono state le pazienti con nessuna patologia o patologie non tumorali, 42 i casi di tumori benigni 9 di tumori maligni e 6 di carcinoma ovarico. HE4 risulta al di sopra del cutoff di 70 pM in tutti i casi di carcinoma ovarico e non risulta alterato in nessuna condizione benigna ad eccezione di un caso gravato da IRC. Di converso CA125 non identifica un caso di carcinoma ovarico e presenta valori al di sopra del cutoff (35 UI/L) in 4 casi di condizioni benigne. Sui 42 casi con nessuna patologia entrambi i marcatori presentano valori al di sopra dei rispettivi cutoff in 3 casi. L’utilizzo dell’algoritmo ROMA ha permesso di identificare correttamente tutti i pazienti con carcinoma come casi ad elevato rischio e tutti i pazienti con patologie benigne come soggetti a basso rischio. Conclusioni: Sebben con ristretta casistica, la valutazione dei risultati ottenuti evidenzia che HE4 è un marcatore più sensibile di CA125, che l’associazione tra HE4 e CA125 risulta essere la soluzione ottimale per la discriminazione tra carcinomi ovarici e neoplasie benigne. Un caso di carcinoma viene perso con la sola valutazione di CA125 ma viene comunque identificato con l’utilizzo dell’algoritmo ROMA. 550 biochimica clinica, 2012, vol. 36, n. 6 P158 ESPERIENZA PLURIENNALE SULL'UTILIZZO DELLA PROTEINA S100B NEL MONITORAGGIO DEL MELANOMA MALIGNO 1 1 1 1 C. Cocco , B. Caruso , L. Lippa , N. Melloni , E. 2 2 1 Vigato , M. Governa , M.S. Graziani 1 Lab. Analisi dO, Az. Osp. Univ. Integrata di Verona Chirurgia Plastica dO, Az. Osp. Univ. Integrata di Verona 2 Introduzione: La proteina S100B è utilizzata nel monitoraggio post-chirurgico del melanoma maligno poichè numerosi studi hanno evidenziato la correlazione fra elevate concentrazioni sieriche della proteina e la progressione della malattia. Scopo del presente lavoro è quello di verificare se la misura di S100B possa essere un parametro utilizzabile nelle decisioni terapeutiche (trattamento intensivo vs standard) di questi pazienti. Materiali e Metodi: Dal 2003 al 2011 la concentrazione sierica della proteina S100B è stata misurata in n= 3097 campioni di siero ottenuti da n=588 pazienti affetti da melanoma maligno istologicamente confermato e a diverso stadio clinico. La misura di S100B è stata effettuata con l’analizzatore Liaison XL (DiaSorin) in chemiluminescenza. Tutti i risultati ottenuti sono stati integrati con i parametri clinici e la diagnostica per immagini (Ecografia, TAC, RMN). Risultati: L’analisi della performance diagnostica della proteina S100B nel predire la progressione della malattia impiegando un cut-off di 250 ng/L ha mostrato una sensibilità=79% (IC 95%: 68.9-86.5), una specificità= 97.4% (IC 95%: 95.3-98.6). Il valore predittivo positivo e negativo sono risultati rispettivamente 86.4 (IC 95%:76.8-92.4) e 95.7 (IC 95%: 93.2-97.3) mentre l’efficienza è stata di 94.2% (IC 95%: 91.7-96). L’analisi con la curva ROC di diversi cut-off (100, 120, 150, 170, 200, 220, 250) ha confermato il valore 250 ng/L come migliore compromesso fra sensibilità e specificità. Conclusioni: La nostra esperienza risulta a favore dell’uso della proteina S100B nella gestione dei pazienti con melanoma cutaneo maligno anche alla luce della recente disponibilità di una terapia adiuvante che si è dimostrata efficace in stadi avanzati della malattia (stadio III e oltre). Kruijiff S, Hoekstra HJ. The current status of S-100B as a biomarker in melanoma. Eur J Surg Oncol 2012;38:281-5. 44° Congresso Nazionale SIBioC - Riassunti Poster P159 GAMMOPATIE MONOCLONALI IN UNA SERIE DI 9237 DONATORI DI SANGUE 1 1 1 1 A. Frezzotti , M. Galeazzi , C. Paladini , P. Caprini , R. 1 1 2 2 Mazzoni , M. Tocchini , G. Riganello , M. Piani 1 Lab. Analisi, Osp. Riuniti, Ancona Dip. Reg. di Medicina Trasfusionale 2 Introduzione: Il riscontro occasionale di una componente monoclonale (CM) in soggetti adulti sani è relativamente frequente: circa 1,7% in soggetti di 50-59 anni e 5% in soggetti con più di 70 anni. Il riscontro di una CM nel siero è importante poiché essa può non essere accompagnata da segni clinici o dati di laboratorio alterati o essere la prima manifestazione di una concomitante malattia linfoproliferaitva. Dal 2003 il Consiglio d’Europa e dal 2005 la Legge Italiana prevede per i donatori di sangue tra gli esami di controllo standard anche la elettroforesi proteica. Materiali e metodi: Negli anni 2007-2011, è stata eseguita la elettroforesi proteica serica con metodo capillare (Capillarys-Sebia) su 9237 donatori, 6193 maschi (67%) e 3044 femmine (33%) di 18-65 anni di età. La immunofissazione è stata eseguita su gel di agarosio (Hydrasys-Sebia). I donatori sono stati suddivisi in 4 gruppi: maschi e femmine di 18-50 e 50-65 anni. E’ stata calcolata la frequenza delle CM nei diversi gruppi e la frequenza dei diversi isotipi. Risultati: I maschi avevano 37,9 (±11,3) anni e le femmine 34,8 (±11,2). I tracciati elettroforetici mostravano anomalie in 174 casi; la immunofissazione su 168 casi evidenziava una CM in 52 (0,56%): 50 su 6193 maschi (0,81%) e 2 su 3044 femmine (0,07%)(p<0,0001). Nei maschi di 18 - 50 anni (5139) si osservavano 21 CM (0,41%) e in quelli di 50 - 65 anni (1054) si osservavano 29 CM (2,75%) mentre solo nelle femmine di 50 – 65 anni (359) si osservavano 2 CM (0,56%). Le CM erano di tipo IgG in 36 casi (69,23%), IgM in 9 (17,31%), IgA in 6 (11,54%) e IgD in 1 (1,92%). La catena leggera era di tipo κ in 34 casi (65,38%), e λ in 18 (34,62%). Conclusione: La presenza di una CM nella nostra popolazione di donatori ha una frequenza simile ai dati riportati in letteratura. La presenza di una CM nelle femmine è significativamente più bassa rispetto ai maschi. Quando si osserva una CM il donatore viene avviato a consulenza ematologia e per misura precauzionale viene escluso dalla donazione. Maisnar V, Tichy M, Rehacek V, et al. Monoclonal gammopathies in a series of 1743 plasma donors. Acta Medica 2006;49:119-21. P160 HIGH DETECTION RATE OF GENOMIC IMBALANCES IN CD138-POSITIVE ENRICHED PLASMA CELLS FROM MULTIPLE MYELOMA PATIENTS E. Danese, S. Munari, M. Montagnana, E. Meneghelli, F. Aprili, G.C. Guidi Dip. di Scienze della Vita e della Riproduzione, Sezione di Biochimica Clinica, AOUI Verona Background: Multiple Myeloma (MM) is a heterogeneous disease, which is characterized by the occurrence of specific genomic abnormalities that are both of diagnostic and prognostic relevance. The detection of these abnormalities through molecular-genetic techniques is hampered by the overall low percentage of proliferating plasma cells (PCs) present in whole bone marrow (BM) aspirates. To overcome the risk of false-negative results, the International Myeloma Working Group has recently suggested to perform interphase FISH (i-FISH) on enriched PCs samples. Aims: (a) to develop and optimize a protocol of magnetic cell sorting (MACS) for the selection of CD138-positive PCs from whole BM aspirates; (b) to compare the diagnostic efficacy of i-FISH in enriched PCs with that in whole BM samples. Methods: 140 samples from patients with MM (n=120) and benign monoclonal gammopathy of undetermined significance (MGUS, n=20) were divided into two groups representing two different phases for analysis: (1) 120 cases referred to our diagnostic centre before June 2012 were evaluated by i-FISH performed on unsorted BM cells from routine chromosomal preparations; (2) 20 cases collected after June 2012 were assessed by iFISH performed on CD138+ sorted BM cells. Magnetic cell separation of PCs was performed using the Whole Blood CD138 MicroBeads (Miltenyi Biotec, Auburn, CA) according to the manufacturer’s protocol. The MACS enrichment was verified by flow cytometric analysis. The i-FISH panel included probes for the identification of t(11;14)(q13;q32), t(4;14)(p16;q32) and 13q14/17p13 aberrations. 300 nuclei were scored for each sample. The detection threshold for gains, losses and translocations was set at 10% for all probes. Results: The percentage of plasma cells after magnetic cell separation varied between 30% and 78%. One or more genomic abnormalities were detected in enriched PCs in 10/20 (50%) cases, whereas in whole BM samples these abnormalities were detected in only 23/120 (19%) of the cases (P<0.001). Conclusion: MACS-enrichment technique results in a significantly increased detection rate of clinically relevant genomic abnormalities in intherphase cells. Ross FM, Avet-Loiseau H, Ameye G, et al. Report from the European Myeloma Network on interphase FISH in multiple myeloma and related disorders. Haematologica 2012;97:1272-7. biochimica clinica, 2012, vol. 36, n. 6 551 44° Congresso Nazionale SIBioC - Riassunti Poster P161 INHIBIN B: A USEFUL MARKER OF TESTICULAR FUNCTION IN CONGENITAL HYPOGONADOTROPIC HYPOGONADISM 1 1 1 A. Gubbiotti , L. Scarnecchia , L. Rosengart , S. 2 Scommegna 1 U.O.C. Biochimica Clinica Azienda Ospedaliera San Camillo Forlanini Roma 2 U.O.C. Pediatria ed Ematologia Pediatrica Azienda Ospedaliera San Camillo Forlanini Roma Background: Inhibin B (InB) is a dimeric glycoproteic hormone produced by testicular Sertoli cells since fetal life. Its main function is providing feed-back regulation on pituitary FSH secretion. Plasmatic InB is detectable in males since birth up to adulthood in a characteristic pattern, so it is widely considered as a marker of future spermatogenesis even in pediatric age. Objectives: to describe the usefulness of plasmatic InB assay in diagnosis and follow-up of congenital hypogonadotropic hypogonadism (CHH) since infancy. Methods: InB B Gen II ELISA, enzymatically amplified three-step “sandwich “ assay (manufactured by Beckman Coulter Inc. and distributed by Pantec) was used for the quantitative measurement of plasmatic InB in human serum. Results: an infant male with multiple pituitary hormone deficiency due to severe anterior pituitary hypoplasia was demonstrated to have CHH, by typical clinical picture (micropenis and small testicular volume), and very low levels of Testosterone, LH, FSH, and InB, during the expected hormonal surge of minipuberty (2nd – 6th month of life). Treatment with recombinant FSH was able to increase testicular volume for age, and restore plasmatic InB levels within the normal range for age. Medium-term follow up (4 years) demonstrated persistence of normalfor-age both testicular volume, evaluated clinically and by testicular sonography, and InB plasmatic levels. Conclusion: this case report demonstrates that InB is a valuable marker of testicular function for diagnosis and follow-up of CHH even in infancy. Crofton PM, Evans AEM, Groome NP, et al. Inhibin B in boys from birth to adulthood: relationship with age, pubertal stage, FSH and testosterone. Clin Endocrinol 2002;56:215–21. 552 biochimica clinica, 2012, vol. 36, n. 6 P162 LA DETERMINAZIONE DELL’ALDOSTERONE CON METODO CHEMIOLUMINESCENTE AUTOMATIZZATO NEL PLASMA E NELLE URINE A. Fortunato, C. Marchetti, G. Soffiati Laboratorio di Chimica Clinica ed Ematologia - Ospedale "San Bortolo" Vicenza Introduzione: L’aldosterone svolge un importante ruolo nella regolazione del bilancio elettrolitico e del rapporto di volume e pressione del sangue. La determinazione della sua concentrazione risulta molto utile nel percorso diagnostico dell’ipertensione per la possibilità di evidenziare fenomeni di iper o ipo secrezione. Materiali e metodi: La concentrazione di aldosterone è stata misurata in 88 campioni di urina delle 24 ore e 95 campioni di plasma EDTA di pazienti afferenti al nostro laboratorio. La popolazione analizzata era costituita complessivamente da 93 donne e 90 uomini. Oltre al metodo correntemente utilizzato, ALDOCTK DiaSorin RIA, le determinazioni sono state eseguite con il sistema completamente automatizzato IDS-iSYS. Le concentrazioni di aldosterone erano comprese tra 1,3 e 40,5 ng/dL e tra 12,6 e 94,1 ng/dL rispettivamente per i campioni di urina e di plasma. La riproducibilità del metodo IDS-iSYS nelle urine è stata valutata secondo il documento CLSI EP5-A2 per concentrazioni di Aldosterone comprese tra 14,1 e 97,7 ng/dL. Risultati: La regressione di Passing-Bablok del sistema iSYS verso il metodo RIA mostra una pendenza di 1,20 (IC95% = 1,11-1,28) ed una intercetta di 2,1 (IC95% = 1,08-3,19) per le urine ed una pendenza di 0,84 (IC95% = 0,76-0,92) ed una intercetta di 3,78 (IC95% = -6,28-13,57) per i campioni di plasma. Il coefficiente di correlazione di Pearson è risultato di 0,951 (P <0.0001) e 0,953 (P <0.0001) rispettivamente per i campioni di urina e plasma. La distribuzione dei valori nel diagramma di Bland-Altman Media% (+ 1.96 DS) è risultata di -39,7 (da -99,8 a 20,3) per le urine e di 5,8 (da -77,9 a 89,5) per i campioni di plasma. Nella valutazione della ripetibilità nei campioni di urina sono stati riscontrati valori di CV compresi tra 5,5 e 12,7 per le determinazioni nella serie e tra 2,8 e 8,4 tra le serie. Conclusioni: La correlazione positiva dei risultati riscontrata tra il metodo IDS-iSYS ed il metodo RIA DiaSorin, considerato come riferimento, associata alla buona riproducibilità dei risultati, ai limitati interventi manuali dell’operatore e tempi brevi necessari per l’ottenimento dei risultati conferiscono al nuovo metodo un ruolo importante nel percorso diagnostico dell’ipertensione. 44° Congresso Nazionale SIBioC - Riassunti Poster P163 LOW LUTEINIZING HORMONE (LH) LEVELS IN MEN WITH LONG TERM EFFECTS AFTER USE OF FINASTERIDE AGAINST ANDROGENIC ALOPECIA 1 1 2 P164 PANCREATIC CANCER (PaCa)-DERIVED SOLUBLE MEDIATORS INDUCE DENDRITIC CELLS (DC) TO ACQUIRE AN IMMUNESUPPRESSIVE PHENOTYPE BY DOWNREGULATING CTLA4 2 S. Cauci , G. Stel , S. Mazzolini , G. Barbina , F. La 1 3 3 3 Marra , G. Mazzon , G. Chiriacò , C. Trombetta 1 Dip. Scienze Mediche e Biologiche, Università di Udine, Udine 2 Laboratorio Analisi d'Elezione, Azienda Ospedaliero Universitaria, Santa Maria della Misericordia, Udine 3 Dip. Clinico di Scienze Mediche, Chirurgiche e della Salute, Clinica Urologica, Università di Trieste, Trieste Background: Finasteride is widely used for benign prostatic hyperplasia (at 5 mg/die) and alopecia (at 1 mg/ die). Finasteride is an inhibitor of the enzyme 5-alphareductase, that impairs the conversion of testosterone (T) to dihydrotestosterone (DHT). So far only 2 studies addressed the impact of finasteride on side effects, particularly depression, among patients treated for alopecia. Only preliminary information is available on hormonal profile of patients with adverse sideeffects. However, the results of the alopecia studies require confirmation and a deeper evaluation of reasons producing long-term persistence of sexual dysfunctions. We aimed to characterize 9 patients with long-term postfinasteride syndrome in comparison to 30 healthy controls. Methods: Nine patients (36 ± 5 years old) with persistent (over 6 months) adverse effects including erectile dysfunction, loss of libido and depression, and 30 healthy matched controls were enrolled. Luteinizing hormone (LH), follicle stimulating hormone (FSH), estradiol (E2), total testosterone, free testosterone, and available testoterone levels were evaluated in morning serum of all subjects. Results: LH was nearly 2-fold lower in cases (P = 0.01), whereas FSH was not statistically different between groups. Testosterone concentrations (including total, free and available forms) were lower in cases than in controls, P < 0.01. Interestingly, the ratio of T/E was lower in cases than in healthy controls, P < 0.01. Conclusions: The percentage of subjects having postfinasteride syndrome is still to be determined and reasons of such persistent effects are unknown. Our study was the first to determine a peculiar hormonal profile in these patients suggesting an impairment of the endocrine interplay of hypothalamus, pituitary and the testis, which specifically dampens LH, one of the gonadotrophins released from the pituitary gland, that helps to produce testosterone. La Marra F, Di Loreto C, Mazzon G, et al. Preliminary evidence of a peculiar hormonal profile in men with adverse effects after use of finasteride against androgenetic alopecia. Am J Pathol 2012;181:S8. 1 1 1 2 E. Gnatta , P. Fogar , A. Aita , C. Frasson , S. 3 3 1 1 Teolato , M. Facco , D. Bozzato , S. Moz , G. 1 2 1 1 Semenzato , G. Basso , D. Basso , M. Plebani 1 Department of Medicine - DIMED, University of Padova, Padova 2 Department of Women’s and Children’s Health, University of Padova, Padova 3 Laboratorio Oncoematologia pediatrica, University of Padova, Padova Objective: An altered function of lymphocytes, DC and immature myeloid cells appears to be an hallmark of tumor-mediated immune suppression and the two inhibitory co-stimulatory receptors PDL-1 and CTLA4 might have a role in this context. The aim of the present in vitro study was to assess whether PaCa cells cross-talk with normal mononuclear circulating cells (PBMC) causing them to acquire an immunesuppressive phenotype and to evaluate whether PDL1 and CTLA4 are involved. Methods: PBMC from blood donors were cultured for 4 days in Control (CTL) and in the PaCa cancer cell line Capan1 conditioned media (CM). Lymphocytes subsets (CD4+, CD8+, CD4+CD25+) and CD33+ immature myeloid cells subsets (CD14+/-; HLA-DR+/-) expressing or not PDL1 and/or CTLA4 were analysed by flow cytometry. To assess immunesuppressive function, myeloid cells were FACS sorted and co-coltured with allogenic total T lymphocytes in 1:20 and 1:40 ratio. Total T lymphocytes proliferation was determined by 3HThymidine uptake. Results: Capan1 CM caused an expansion of CD4+CD25+ (p=0.01) and a reduction of CD33+CD14HLA-DR+ (p=0.03) cells. In this latter cellular subset, CM caused also an increase of PDL1 (p=0.046) and a decrease of CTLA4 (p=0.05) positive cells. FACS sorted CTL and CM CD33+CD14-HLA-DR+ cells did not significantly affect the proliferation of allogenic total T lymphocytes at 1:20 (p=0,54) or at 1:40 ratio (p=0,81). The CD33+CD14-HLA-DR+ PDL-1+ cells did not significantly modify allogenic T cells proliferation with respect to PDL- cells (p=0,11), while those cells which were CTLA4 negative caused a significant inhibition of T cell proliferation in comparison of CTLA4 positive cells (p=0,008). Conclusions: PaCa-derived soluble factors induce the expansion of the inhibitory lymphocytes subset CD4+CD25+ and a reduction of the immature CD33+CD14-DR+ dendritic cells. The tumor associated reduced expression of the inhibitory molecule CTLA4 in this cell population was demonstrated to characterize an immunosuppressive phenotype and this study suggests to take care in the use of anti-CTLA4 therapies. biochimica clinica, 2012, vol. 36, n. 6 553 44° Congresso Nazionale SIBioC - Riassunti Poster P165 RICERCA DEL SANGUE OCCULTO FECALE E STABILITA’DELL’EMOGLOBINA FECALE: CONFRONTO TRA DUE TAMPONI DI CONSERVAZIONE P166 SIMULTANEOUS CORTISOL AND CORTISONE MEASUREMENT IN URINE BY LC-MS/MS IN A ROUTINE LABORATORY 1 E. Gnatta, M.G. Epifani, M. Zaninotto, M. Plebani UOC Medicina di Laboratorio, Azienda OspedalieraUniversità degli Studi, Padova 2 2 2 G. Antonelli , C. Artusi , M. Marinova , L. Brugnolo , M. 2 2 Zaninotto , M. Plebani 1 Dip di Medicina, Università degli Studi di Padova Dip interaziendale Azienda Ospedaliera-Università degli Studi, Padova Servizio Medicina di Laboratorio 2 Obiettivo: La determinazione del Sangue Occulto Fecale (SOF) è di fondamentale importanza per una diagnosi precoce del cancro colon-rettale. Scopo dello studio è valutare la stabilità dell’emoglobina Fecale (HbF) a diverse temperature (T) in campioni SOF positivi con due diversi dispositivi di raccolta del campione (Sentinel CH): FOB Gold Tube Screen e FOB Gold Tube NG con tampone di conservazione H (BH) e N (BN) rispettivamente. Inoltre sono state analizzate le prestazioni analitiche di BH, progettato per lo screening con l’obiettivo di ridurre la degradazione di HbF a temperatura (T) ambiente. Metodi: LOQ, imprecisione totale (2 livelli di controllo; 2 campioni; range: 66.3-447.6 ng/mL), linearità ed effetto prozona sono stati valutati mediante uso di Hb umana di sintesi in BH. Le prove di stabilità per FOB Gold Tube Screen sono state condotte su 3 campioni fecali (HbF=96.5, 227.8 e 649.5 ng/mL): da ciascuno si è ricavato un pool (50 mL da 30 campionamenti). I 3 pools sono stati aliquotati e conservati 15gg a T 4, 23, 30 e 37 °C . Stesso procedimento è stato seguito per FOB Gold NG con altri 3 campioni (HbF=131.9, 277.2 e 632.3 ng/ mL). Un’aliquota di ogni campione per ogni temperatura è stata testata, in triplicato, ai giorni 0, 1, 4, 5, 8, 11, 14 e 15 sullo strumento Cobas 6000 (Roche Diagnostics) ed è stata valutata la percentuale (%) di degradazione dell’HbF. Risultati: Prestazioni analitiche: LOQ=18,9 ng/mL; imprecisione totale=6.5-9.41%; assenza di effetto prozona fino a 20.000 ng/mL; ottima linearità (slope=0.99 intercept=1.26, range: 74.8-800.8 ng/mL) anche in campioni con varianti emoglobiniche (HbS, HbC e HbA1c). Degradazione media % HbF dopo 5gg T 4 °C: BN=5.3, BH=-3.2; T 23 °C: BN=-12.8, BH=-9.66; T 30 °C: BN=-49.9, BH=-28.5; T 37 °C: BN=-66.0, BH=-54.6. Degradazione media % HbF dopo 8gg T 4 °C: BN=-4.8, BH=-4.6; T 23 °C: BN=-16.3, BH=-10.31; T 30 °C: BN=-56.1, BH=-38.3; T 37 °C: BN=-80.0, BH=-72,3. Conclusioni: Il tampone BH, a differenza di BN, sembra garantire all’HbF una maggiore stabilità. Entrambi i dispositivi non permettono una conservazione dell’HbF ad alte T (>23 °C). La degradazione % osservata non risulta essere concentrazione-dipendente per BH mentre BN conserva meglio i campioni a bassa concentrazione. 554 biochimica clinica, 2012, vol. 36, n. 6 Introduction: Cortisol (F) is a steroid hormone produced by adrenal gland under the influence of adrenocorticotrophic hormone. It’s metabolized via the action of the enzyme 11 ß-hydroxydehydrogenase type 2 (11 ß-HSD2), expressed in the kidney, colon and salivary tissue, which converts F to the inactive form cortisone (E). Urine free E and the ratio of urine F to E are considered indices of 11 ß-HSD2 in the kidney and the simultaneous analysis of F and E is potentially useful in patients with adrenal disorders, but also in athletes in relation to physical exercise and training status. Historically, immunoassay were widely used for F analysis, but successively chromatographic methods have been preferred because less susceptible to interference from E and other steroid metabolites. Few LC-MS/MS methods for F and E analysis have been reported, but these methods are time- and labor-intensive. Aim: Development and validation of a LC-MS/MS method to measure simultaneously F and E in urine with simple sample preparation. Methods: After the urine acidification, the samples were processed to the LC-MS/MS system that includes an online SPE. Chromatographic separation of F and E was achieved by use a Zorbax Eclipse XDB-C18 (4.6 mm x 50 mm, 1.8 μm). F, E, d4F and d7E were detected in the multiple-reaction monitoring mode. Both quantitative and qualitative mass to charge transitions were used to monitor F (363±121, 363±327) and E (361±163, 361±145), with single transitions for the internal standards (d4F 367±121, d7E 369±169). Tests for linearity, LOD, LOQ, imprecision and recovery were carried out. Results: Calibration curves were linear throughout the studied ranges (F: 5-680 nmol/L, E: 11-1385 nmol/L) with correlation coefficient >0.998 for both analytes. LOD and LOQ were 4 and 5 nmol/L for F and 5 and 6 nmol/L for E. The intra-day and inter-day imprecisions were <10% for F and E. Recoveries ranged from 91 to 112%. Conclusions: The proposed method demonstrated satisfactory linearity, analytical sensitivity, imprecision and accuracy for F and E. The pre-analytical variability has to be investigated as well as the reference ranges. Taking into account the obtained data, we should conclude that the method can be proposed for the application in a routine clinical laboratory. 44° Congresso Nazionale SIBioC - Riassunti Poster P167 TRE CASI DI GAMMAPATIE MONOCLONALI DI TIPO IgD P168 UNA RARISSIMA CONDIZIONE: DESCRIZIONE DEL SECONDO CASO DI MGUS IgE M. Galeazzi, A. Frezzotti, C. Paladini, P. Caprini , G. Pennesi , M. Tocchini G. Avveduto , F. Balboni , T. Biagioli , A. Caldini , M. 1 1 2 1 Brogi , A. Terreni , B. Morrocchi , F. Cassani , A. 1 1 1 Gironi , L. Reggiani , G. Messeri Lab. Analisi, Osp. Riuniti, Ancona Introduzione: Le componenti monoclonali (CM) di tipo IgD sono rare e nel 60% sono di tipo IgDλ e quasi sempre associate a mieloma multiplo (MM); rarissimi sono i casi di gammapatia monoclonale di incerto significato (MGUS). Materiali e metodi. L’elettroforesi serica è stata eseguita con la tecnica capillare, (Capillarys-Sebia); l’immunofissazione è stata eseguita su gel di agarosio (Hydrasys-Sebia). Sono state determinate le immunoglobuline e le catene leggere libere κ e λ (Freelite TM –Binding Site su BNA II-Dade Bhering). Risultati: Caso 1. Maschio di 63 anni: nel febbraio 2009 veniva identificata una CM IgDλ; il rapporto κ/λ era 0,05 (IR 0,26-1,65). Le IgG risultavano leggermente diminuite, 5,52 g/L; normali erano Hb: 14,1 g/dL e creatinina: 1,1 mg/dL. L’esame urine evidenziava la perdita di 5g/24h di proteine e la presenza di catene leggere libere di tipo λ. La diagnosi clinica era di MM. Il paziente è attualmente in terapia. Caso 2. Maschio di 60 anni: nel settembre 2009 veniva identificata una CM IgDλ; il rapporto κ/λ era 0,08. Le IgG risultavano leggermente diminuite, 5,47 g/ L; normali erano Hb: 13,6 g/dL e creatinina: 1,0 mg/dL. Assente era la proteinuria di Bence Jones. La biopsia midollare evidenziava plasmacellule atipiche pari all’8%. La diagnosi clinica era di MGUS. A tre anni di distanza i dati di laboratorio sono pressoché invariati ed il paziente è asintomatico. Caso 3. Femmina di 62 anni: nel febbraio 2010 venivano identificata una CM IgDκ e la presenza di catene libere di tipo κ; alterati erano i valori di Hb: 9,4 g/dL e creatinina: 2,6 mg/dL. La diagnosi clinica era di MM e la paziente moriva dopo 4 mesi per insufficienza renale. Conclusione: Le CM vanno accuratamente tipizzate e la identificazione di una IgD è importante poiché è caratterizzata da rapida evoluzione e quindi richiede un attento monitoraggio. Inoltre è importante che in caso di insufficienza renale di dubbia eziologia si proceda ad uno studio approfondito dell’assetto proteico poiché è elevato il rischio di misisinterpretare le nefropatie secondarie a discrasie plasmacellualri. Kuliszkiewicz-Jnus M, Zimmy A, Sokolska V, et al. Immunoglobulin D myeloma-problems with diagnosing and staging (our experience and literature review). Leuk Lynphoma 2005;46:1029-37. 1 2 1 1 1 Laboratorio Generale, Dipartimento Diagnostica di Laboratorio, Azienda Ospedaliero Universitaria Careggi, Firenze 2 Laboratorio Analisi Chimico Cliniche, IFCA, Firenze Il Mieloma Multiplo (MM) IgE è il più raro e rappresenta circa lo 0.01% di tutti i MM. Il primo caso è stato descritto nel 1967 e ad oggi sono 46 i casi riportati in letteratura. Il MM IgE è più aggressivo e con una prognosi più infausta: la sopravvivenza media dalla diagnosi è infatti 16 mesi, contro 30 degli altri tipi di MM. Scopo di questo lavoro è descrivere un caso clinico di MGUS IgE, condizione ancora più rara del MM IgE, di cui in letteratura è riportato solo un altro caso, descritto nel 1980. A luglio 2012, il signor PP di 69 anni viene ricoverato presso l’AOU Careggi per un intervento neurochirurgico (glioblastoma parasagittale destro), ed in seguito ricoverato in Riabilitazione Neurologica (IFCA, Firenze). Agli esami di ingresso l’elettroforesi sieroproteica mostra una spiccata ipogammaglobulinemia, ed una lieve alterazione in zona beta 2. L’esame emocromocitometrico, e gli altri parametri ematochimici risultano nella norma. Viene eseguita l’immunofissazione (IFE) che evidenzia una componente monoclonale IgE Lambda, corrispondente all’alterazione del tracciato in zona beta 2. La misura delle catene leggere libere sieriche risulta nella norma. Il signor PP riferisce che già nel 1994 era stato sottoposto ad esami di approfondimento in seguito al riscontro di un incremento di IgE sieriche. Consultando i dati archiviati presso Laboratorio Generale AOUC, è stato ritrovato il tracciato elettroforetico e l’IFE eseguiti nel 1994 che risultano sovrapponibili a quelli attuali, così come l’IFE urinaria risultava negativa. Negli anni successivi fino al 1999 il sig PP si sottopone a controlli con cadenza annuale: l’entità della componente monoclonale rimane costante e la proteinuria di Bence Jones resta negativa. In seguito il signor PP riporta di aver volontariamente interrotto i controlli periodici. Dal 1994 a oggi il paziente non ha mai avuto sintomatologia clinica che possa essere associata al MM. Pertanto si può concludere di essere in presenza di un caso di MGUS IgE Lambda, rimasto stabile per 18 anni, a conferma del fatto che le discrasie plasmacellulari IgE, malgrado la maggior aggressività del MM IgE, non sono sempre associate ad un fenotipo maligno. Ludwig H, Vormittag W. "Benign" monoclonal IgE gammopathy. Br Med J 1980;281:539-40. biochimica clinica, 2012, vol. 36, n. 6 555 44° Congresso Nazionale SIBioC - Riassunti Poster P169 UTILIZZO DELLA TIREOGLOBULINA ULTRASENSIBILE NEL FOLLOW-UP DI PAZIENTI CON CARCINOMA TIROIDEO 1 1 1 P170 EXTRAMEDULLARY HAEMATOPOIESIS IN ADULT POLYTRANFUSED PATIENTS WITH THALASSAEMIA: THE HIGH PREVALENCE OF THE GENETIC COMPOUNDS IVS 1-6/CODON 39 1 M. Brugia , S. Suppressa , A. Serpilli , V. Scocco , M. 1 2 2 2 Tocchini , A. Taccaliti , F. Silvetti , G. Palmonella , M. 2 Boscaro 1 1 2 P. Ricchi , M. Ammirabile , T. Di Matola , A. 1 1 1 1 Spasiano , S. Costantini , P. Cinque , L. Pagano , L. 1 Prossomariti 1 Laboratorio Biochimica Clinica e Microbiologia Azienda Ospedali Riuniti Ancona 2 Clinica Endocrinologica Azienda Ospedali Riuniti Ancona Premesse: Il carcinoma papillare e follicolare della tiroide o carcinomi tiroidei differenziati (CTD) sono le neoplasie endocrine più frequenti e la prevalenza di recidive è piuttosto elevata. Nel follow-up dopo trattamento chirurgico e ablativo la Tireoglobulina (Tg) nel siero dovrebbe essere indosabile. Secondo le recenti linee guida la presenza di livelli di Tg >1 ng/mL in terapia o livelli >2 ng/mL dopo stimolo con rhTSH, deve essere considerata come ripresa di malattia. Scopo del lavoro è stato quello di verificare l’utilità del dosaggio della Tg ultrasensibile (Tg us), che insieme ai dati ecografici, potrebbe ridurre il ricorso alla stimolazione con rhTSH e altri test aggiuntivi. Materiali e metodi: Tra 1/11/2011 e 01/03/2012 sono stati esaminati 65 campioni di siero di 19 pazienti maschi e 46 femmine sottoposti a tiroidectomia totale per CTD e seguiti presso la Clinica Endocrinologica dell’Ospedale di Ancona. Su tutti i pazienti è stato effettuato il dosaggio della Tg basale e di quella dopo stimolo (ECLIA Modular E170). La Tg basale è stata dosata anche con metodo ultrasensibile (Access Beckman Coulter). Su tutti i pazienti inoltre è stata effettuata la ricerca di anticorpi anti-Tg (CMIA Architect Abbott). Risultati: Tutti i pazienti sono risultati negativi per la ricerca degli anticorpi anti-Tg. La correlazione tra Tg us e quella dopo stimolo è risultata statisticamente significativa. I pazienti, in base all’ecografia del collo, ai referti istologici e ai valori di Tg us, sono stati suddivisi in 5 gruppi. Gruppo A Tg ≤0.03 ng/mL (9 pazienti) nessuno ha presentato recidiva di malattia. Gruppo E Tg #1 ng/mL (8 pazienti) tutti hanno presentato recidiva. Nei restanti gruppi B, C, D Tg 0,04-0,99 ng/mL (48 pazienti) 7 hanno presentato recidiva. Conclusioni: Dall’elaborazione dei dati, si evidenzia che la Tg us è in grado di individuare recidiva di malattia anche nei pazienti con valori di Tg <1 ng/mL. Il dosaggio della Tg us nel follow-up del CTD può essere utile in quanto evita la stimolazione esogena con rhTSH contenendo i costi sanitari (circa 1000 € a paziente) e riduce il disagio per il paziente. Medical guidelines for clinical practice for the diagnosis and management of thyroid nodules. Endocr Pract 2006;12:63-102. 556 biochimica clinica, 2012, vol. 36, n. 6 1 UOSD Centro delle Microcitemie AORN Cardarelli, Napoli 2 Patologia Clinica Ospedale dei Colli, AORN Monaldi, Napoli Introduction: The mechanisms responsible for the sporadic occurrence of Extramedullary Hematopoiesis (EMH) in polytransfused thalassaemic patients have not yet been clarified. In this study we tried to clarify the influence of genotype and of other factors on the presence of EMH. Material and methods: We performed a retrospective database review of our polytransfused thalassaemic patients between January 2006 and December 2011. Demographics, transfusion, genetic, radiologic and biochemical data were collected and statistically analysed. Results: EMH was found in 18 patients. Patients with EMH were older, had higher number of erythroblasts and higher level of the soluble form of transferrin receptor (sTfR) with respect to patients without EMH; on the other hand, patients with EMH had a lower iron intake and a higher pre-transfusion Hb level as compared with those without EMH. 9 out of 18 patients with EMH had the genetic compounds IVS 1-6/codon 39. A high frequency of thrombotic events was also recorded among patients with this genetic compounds. Conclusion: Overall, among the cohort of our transfused patients, these data identify the presence of a category of patients mostly with the genetic compounds IVS 1-6/codon 39 which have increased sTfR level and excessive expansion of erythroid marrow, despite the optimal transfusion regimen, probably responsible for the tendency to develop EMH. 44° Congresso Nazionale SIBioC - Riassunti Poster P171 BIOLOGICAL VARIABILITY OF LYMPHOCYTE SUBSETS OF HUMAN ADULTS’ BLOOD F. Tosato, G. Pantano, M.C. Sanzari, D. Bernardi, A. Padoan, P. Fogar, M. Plebani P172 DETECTION OF SERUM IGA MONOCLONAL COMPONENTS IN PATIENTS EVALUATED FOR AL AMYLOIDOSIS, USING HEAVY CHAIN/LIGHT CHAIN IMMUNOASSAY (HEVYLITE) 1 Dip. Medicina di Laboratorio, Az. Osp. Padova Introduction: Lymphocyte subpopulations are altered in many immune diseases. To evaluate the effect of medical treatment or to follow the course of disease, the distribution and changes of the lymphocyte populations are followed for longer periods, both in the clinical setting and for research. In order to properly estimate longitudinal changes it is important to take into consideration the biological variation. Objective: We considered biological variability in order to provide an insight into the performance of lymphocyte populations allowing to define quality specifications of their determination, and to define the utility of traditional population-based values. Methods: Four-colour-flow cytometry was used to investigate biological variation of lymphocyte populations in peripheral blood of 20 adult healthy subjects (eleven women, nine men aged 25–58 years) recruited from our laboratory staff and followed for 3 months. Absolute counts and proportions were determined for T-cells (CD3+), T-helper cells (CD3+CD4+), cytolytic T-cells (CD3+CD8+), B-cells (CD3-CD19+), NK-cells (CD3-CD16+/56+), non-MHC restricted cytolitic T-cells (CD3+CD56+) and activated T-cells (CD3+HLA-DR+). Results: CVintra, CVbetween and Individuality Index are: 0.04, 0.10 and 0.13 for CD3; 0.08, 0.17 and 0.20 for CD4; 0.05, 0.26 and 0.03 for CD8; 0.11, 0.29 and 0.14 for CD19; 0.25, 0.49 and 0.28 for CD56; 0.23, 0.45 and 0.21 for CD16; 0.38, 0.62 and 0.43 for CD56+CD3+; 0.23, 0.56 and 0.14 for CD3DR. Quality specifications: CV desirable, CV minimum and CV optimum are: 0.020, 0.030 and 0.010 for CD3; 0.040, 0.060 and 0.020 for CD4; 0.025, 0.038 and 0.013 for CD8; 0.055, 0.083 and 0.028 for CD19; 0.125, 0.188 and 0.063 for CD56; 0.015, 0.173 and 0.058 for CD16; 0.190, 0.285 and 0.095 for CD56+CD3+; 0.115, 0.173 and 0.058 for CD3DR. Conclusions: Data on the components of biological variation can be applied to set quality specifications for allowable precision, bias and total error. Data on withinsubject biological variation and analytical precision can be used to determine the change that has to occur to an individual’s serial results before the change is significant (reference change values). Comparing withinand between-subject biological variation allows us to define the uselessness of normal ranges. 1 2 1 F. Lavatelli , G. Palladini , G. Sarais , V. Valentini , T. 2 1 1 3 1 Bosoni , A. Foli , M. Nuvolone , S. Harding , G. Merlini 1 Amyloidosis Research and Treatment Center, Dept. of Molecular Medicine, Fond. IRCCS Policlinico San Matteo and University of Pavia, Italy 2 Clinical Chemistry Dept., Fond. IRCCS Policlinico San Matteo, Pavia, Italy 3 The Binding Site, Birmingham, UK Background: AL amyloidosis patients often have small monoclonal components (MC), difficult to quantify by densitometry. IgA are most problematic, due to anodic TM migration and masking under ß-zone proteins. Hevylite IgA assay (The Binding Site) separately quantifies IgAκ and IgAλ and infers clonality from IgAκ/IgAλ-ratio. This study aimed at assessing Hevylite performance in identifying serum IgA MC in a series of patients referred for suspected systemic AL amyloidosis, in whom agarose gel electrophoresis/immunofixation (IFE) had detected IgAκ or IgAλ MC, or IgA bands without identifiable associated light chains (LC), or increased IgA background without clear MC. Methods: Serum MC were assessed by IFE and free light TM chain (FLC) quantification (Freelite ) in 35 consecutive patients. Hevylite reference ranges are: IgAκ 0.48-2.82 g/ L; IgAλ 0.36-1.98 g/L; IgAκ/IgAλ-ratio 0.8-2.04. Results: At IFE, 28/35 patients had complete IgA components (8 IgAκ; 20 IgAλ), 17 of which (6 IgAκ; 11 IgAλ) could be quantified by densitometry. 2 patients had IgA bands without identifiable LC; 5 had increased IgA background. Using Hevylite, IgAκ/IgAλ-ratio was elevated in all cases with IgAκ MC at IFE; 6 of them also had high IgAκ concentration (range: 2.94-30.1 g/L). IgAκ/IgAλ-ratio was low in 18/20 cases with IgAλ MC (13 had increased IgAλ; range: 2.01-22.4 g/L), normal in the remaining two. In both patients with IgA bands without detectable LC, IgAκ/IgAλ-ratio was normal; 2/5 patients with increased IgA background had high IgAκ/IgAλ-ratio, with normal κ/λ FLC ratio. AL amyloidosis was eventually diagnosed in 20 patients; in all, IFE showed complete IgA MC (quantifiable by densitometry in 12). In 18/20, IgAκ/IgAλ-ratio was abnormal; in the remaining two, who had IgAλ at IFE, monoclonal λ FLC were detected by κ/λ ratio. No patients with IFE polyclonal background had AL. Conclusions: Hevylite showed good diagnostic sensitivity (90%) in IgA AL amyloidosis, which can be improved with combination of FLC measurement. Calculation of IgAκ/ IgAλ ratio and quantification of IgAκ and IgAλ allowed quantitative estimation of the MC in the majority of AL amyloidosis patients with IgA components, comparing favorably with SPEP. biochimica clinica, 2012, vol. 36, n. 6 557 44° Congresso Nazionale SIBioC - Riassunti Poster P173 EARLY DETECTION OF CD4+CD26-CD38+ SUBSET IN HODGKIN’S LYMPH NODES 1 1 1 V. Gasparetto , B. Callegari , L. Candiotto , A. 2 1 1 Padoan , N. Toffano , R. Di Gaetano , M.C. 2 1 Sanzari , G. Tagariello P174 EFFICACIA DI UN SISTEMA MULTIREGOLE NEL RICONOSCIMENTO DI PATOLOGIE ONCOEMATOLOGICHE MEDIANTE ESAME EMOCROMOCITOMETRICO 1 1 1 1 C. Parma , F. Cappellini , G. Limonta , M. Bertona , P. 2 Brambilla 1 U.O. Trasfusionale ed Immunologia, C.Reg. per le Malattie del Sangue, Osp San Giacomo, Castelfranco Veneto, ULSS 8 Veneto 2 Dip. di Medicina di Laboratorio, Az Osp. Universitaria, Padova 1 Introduction: Hodgkin lymphoma (HL) is characterized by a minority of neoplastic cells-Hodgkin and ReedSternberg cells (HRS)-that express the membrane CD30 and grow in typical microenvironment composed of reactive elements. The HRS with disturbed cytokine production appear to regulate their surrounding and for example attract activated but anergic CD4 T. Studies have shown that the presence of CD30 and the resulting cytokine network to inhibit also the expression of the activation marker CD26 on CD4,contribute to the impaired immune response observed in HL. We explored with a simple cytometric test whether the absence of CD26 was able to differentiate HL from reactive Lymph Node (RLN) and to use it in HL patient’s follow up. Methods: Cells suspension from LN (102 HL and 43 RLN) were analyzed by flow cytometry (FC) using antibodies such as CD45, and CD3, CD4 for T cells, CD19 for B cells and marker of activation CD38 than CD26.Data were analyzed with box plot diagrams and ROC curve. Results: Compared with RLN, HL showed some statistically significant differences: reduced CD19+, increased CD3+ and expanded subset CD4+CD26CD38+. The area under ROC curve was 0,8639. Comparison between RLN and histotype-differenciated HL confirm these results, in particular the mixed-cellularity and scleronodular histotypes. Clinical data show, with the increase of the stage of HL, an increase of CD3+ cells while a reduction of CD19+ cells is observed. Peripheral blood (PB) from HL at diagnosis, compared with a control group of blood donors, show an increased CD4+CD26CD38+ subset (results not statistically significant due to the small sample size) that were also back to normal values in patients reaching complete remission. Conclusions: These results demonstrate that increased CD4+CD26-CD38+ in lymph node of HL seems to be a useful tool to differentiate them from RLN. Data from PB at diagnosis and following therapy suggest to use this subset as a possible marker for monitoring HD. Introduzione: L’esame emocromocitometrico è un valido supporto nello screening oncoematologico. Sono state prese in considerazione le neoplasie mieloproliferative (NM) e la Leucemia Linfatica Cronica (LLC). Le NM sono malattie clonali della cellula staminale mieloide compredenti Leucemia Mieloide Cronica (LMC), Policitemia Vera (PV), Trombocitemia Essenziale (TE) e Mielofibrosi Idiopatica (MI). La prevalenza delle NM nella popolazione è di 0.02%. La LLC è una patologia caratterizzata dalla proliferazione clonale di linfociti B piccoli e maturi, con una prevalenza dello 0,04% nella popolazione generale. Nel laboratorio analisi dell’ospedale di Desio sono attualmente in uso specifiche regole di validazione che contribuiscono al riconoscimento delle patologie oncoematologiche. Scopo: Valutazione dell’efficacia delle regole di validazione nel riconoscimento delle patologie oncoematologiche Materiali e metodi: Mediante il sistema di validazione Sysmex SIS sono state impostate regole atte al riconoscimento delle NM ed LLC. Le regole WBC 20, 25, 28, che prendono in considerazione alterazioni della linea mieloide correlate a dati anagrafici del paziente, sono specifiche per il riconoscimento delle NM. La regola WBC 13, che blocca i campioni di pazienti con più di 12 anni, 558 biochimica clinica, 2012, vol. 36, n. 6 Servizio Universitario di Medicina di Laboratorio Azienda ospedaliera di Desio e Vimercate, Desio (MB) 2 DIMS, Dipartimento di Medicina Sperimentale, Università degli studi di Milano – Bicocca, Monza (MB) 3 aventi un valore di linfociti superiore a 5000 /mm , è specifica per la LLC. Risultati: Le regole impostate per le NM hanno sensibilità (Sn.) del 41% e specificità (Sp.) del 98%. La prevalenza della malattia è di 0,02%, la probabilità post test in caso di test positivo (PPT+) sale allo 0,6%, la probabilità post test in caso di test negativo (PPT-) scende allo 0.0007%. Per la LLC la regola mostra una Sn. dell’82% ed una Sp. del 99%. La prevalenza della LLC è di 0,04%, la PPT+ sale al 2,6%, mentre la PPT- scende allo 0.0006%. Conclusioni: Le regole di validazione introdotte per identificare le patologie oncoematologiche si sono rivelate utili in quanto le PPT per entrambe le patologie oncoematologiche considerate si discostano sensibilmente dalle rispettive “probabilità pre test”. 44° Congresso Nazionale SIBioC - Riassunti Poster P175 EVALUATION OF THE DIAGNOSTIC PERFORMANCE OF THE SYSMEX XE-2100 AND OF THE ADVIA 120 AUTOMATED HEMATOLOGY ANALYZERS IN TERMS OF MORPHOLOGIC FLAGS P176 EVALUATION OF THE RETICULOCYTE COUNTING BY THE MINDRAY BC 6800 AUTOMATED HEMATOLOGY ANALYSER: COMPARISON WITH ABX PENTRA 120, COULTER LH750 AND MICROSCOPY S. Colarossi, N. Mangialetto, G. Palumbo, S. Capalbo 1 U.O.C. Ematologia, Azienda Ospedaliero-Universitaria Ospedali Riuniti, Foggia Introduction: Automated hematology analyzers produce morphologic flags when processing samples with abnormal cells. Methods: The aim of this study was to evaluate the diagnostic performance of two hematology analyzers, ADVIA 120 (Bayer) and Sysmex XE-2100 (Dasit), in terms of morphologic flags, in comparison with manual microscopy review (NCCLS H20-A). The morphologic flags of each analyzer were divided into four categories: Blasts, Immature Granulocytes and/or Left Shift, Atypical Lymphocytes and Nucleated RBCs. The suspect message Abn Lympho/L_Blasts? is only created by the XE-2100. One hundred blood samples analyzed in our routine haematology laboratory were included in this study. Results: To compare the results from XE-2100, ADVIA-120 and the reference procedure, truth tables were constructed. The predictive value of instrument flagging for the presence of abnormal WBCs and of nucleated RBCs after clinical review was expressed by the following parameters: sensitivity, specificity, efficiency. Nine of 100 blood films showed ≥1% blasts on microscopic examination; the rates of false negative (FN) results were 2% for the ADVIA 120 whereas the sensitivity of blast flag was 100% on the XE-2100. Nine samples contained ≥1% immature granulocyte; only one sample was missed by ADVIA 120 flagging. Three blood smears showed ≥1% atypical lymphocytes; the rate of FN results was 1% for both analyzers. Seven samples contained NRBCs and were flagged by both instruments. The specificity of ADVIA 120 were 90%, 83%, 77%, 91%, in terms of blasts, IG and/or LS, Atypical Lympho, NRBCs, respectively. The false positive (FP) rates produced by the automated analyzer XE-2100 were 4%, 7%, 16%, 4%, in terms of blasts, IG and/or LS, Atypical Lympho, NRBCs, respectively. The Abn Lympho/L_Blasts flag occurred in 22 of 100 samples; 18 samples contained abnormal lymphocytes or lymphoid blasts; two positive samples were missed by XE-2100 flagging. Conclusions: The XE-2100 represents improvement in terms of specificity and sensitivity for the detection of abnormal WBCs and of NRBCs. Buttarello M. GdSE-SIMeL. Risultati della sperimentazione multistrumentale in ematologia automatizzata: lo stato dell’arte. Riv Med Lab-JLM 2004;5:136-41. 1 1 R. Grillone , M. Buonanno , A. Chiefalo , M. 1 1 1 1 Conticelli , A. Contina , A.M. Riccio , C. Saglioccolo , A. 1 1 2 Scognamiglio , F. Tagliaferri , E. Grimaldi , F. 2 1 Scopacasa , B. Dente 1 U.O.C. di Medicina di Laboratorio, Ospedale San Paolo ASL NA1 centro, Napoli 2 Dipartimento di Biochimica e Biotecnologie Mediche, Università degli Studi di Napoli Federico II The Mindray BC 6800 analyzer (Mindray Bio-Medical Electronics Co) is a new developed automated hematology analyser with high throughput rate. It provides 33 reportable and 14 research parameters of leukocyte, red and platelet series, a differential leukocyte count (DLC), reticulocytes and erythroblast (NRBC). The technologies used for the DLC include fluorescence, laser light scatter (forward and side scatter) and analyzing a 3 dimensional scattergram (“SF Cube” technology). For reticulocyte analysis the analyser uses a cyanine dye to stain the reticulocye’s RNA, and fluorescence intensity, scatter light intensity at two angles and cell size are registered. The aim of this study was to evaluate the reticulocyte counting from the Mindray BC6800 in comparison with those obtained from the ABX Pentra DX120 (Horiba ABX), Beckman Coulter LH750 and microscopic count used as reference. The obtained results demonstrated no carryover. Precision was good with low coefficients of variation (CV= 2.61%). Although the analysis of results evaluated with Wilcoxon test revealed significant differences between BC6800 and the other methods (p<0.05), the Spearman rank correlation coefficients revealed that BC6800 gave reticulocyte count results that correlate well with those obtained by manual method (rs = 0.963); a slightly lower correlation was observed between BC6800 and ABX Pentra as well as between BC6800 and LH750 (rs = 0.863 and rs = 0.903 respectively). BC 6800 results compared very well with those obtained by manual method and these data were confirmed by Bland-Altman analysis: no significant bias (mean of difference: -0.06) was observed between BC6800 and manual method. Slight difference between BC6800 and both ABX Pentra 120 and Coulter LH750 (mean of difference: -0.15 and -0.147 respectively) was found and a slight bias was revealed by Bland-Altman analysis. In conclusion we have found that for reticulocyte counting, the Mindray BC6800 provides accurate and reliable results. Piva E, Brugnara C, Chiandetti L, et al. Automated reticulocyte counting: state of the art and clinical applications in the evaluation of erythropoiesis. Clin Chem Lab Med 2010;48:1369–80. biochimica clinica, 2012, vol. 36, n. 6 559 44° Congresso Nazionale SIBioC - Riassunti Poster P177 IMPATTO DELL’IMPLEMENTAZIONE DELLE REGOLE DI VALIDAZIONE DELL’ESAME EMOCROMOCITOMETRICO MEDIANTE IL SISTEMA SYSMEX SIS NEL LABORATORIO ANALISI DELL’OSPEDALE DI DESIO 1 1 1 1 Servizio Universitario di Medicina di Laboratorio, Azienda ospedaliera di Desio e Vimercate, Desio (MB) 2 DIMS, Dipartimento di Medicina Sperimentale, Università degli studi di Milano – Bicocca, Monza (MB) Introduzione: L’esame emocromocitometrico è, per semplicità di esecuzione e capacità di fornire informazioni, uno degli esami più richiesti in laboratorio analisi. Il processo di validazione dei dati utilizza algoritmi complessi, composti da regole fondate su dati analitici, allarmi strumentali ed informazioni sui pazienti. L’applicazione degli algoritmi permette la validazione automatica dei campioni che non hanno violato le regole e l’identificazione di quelli che, bloccati dalla violazione di almeno una regola, necessitano di revisione. Presso il laboratorio analisi dell’ospedale di Desio è in uso un set di regole impostate mediante il sistema di validazione Sysmex SIS. Scopo: Valutazione dell’impatto delle regole di validazione in uso sull’attività di laboratorio. Materiali e metodi: Le analisi sono state eseguite sul contaglobuli Sysmex XE 2100. Nel periodo compreso tra Marzo ed Agosto 2012 sono stati raccolti i dati relativi agli esami emocromocitometrici sottoposti alle regole di validazione impostate a Gennaio 2012. Risultati: Dei 69964 campioni (media giornaliera = 578 campioni), l’8,4% ha richiesto una revisione: il 4,5% da parte del personale medico, il 3,9% da parte di quello tecnico. Dei campioni rivisitati dal personale tecnico il 34% è stato ripetuto per allarmi relativi alla conta differenziale dei globuli bianchi, il 39% per allarmi relativi ai parametri emometrici e il 54% per allarmi riguardanti le piastrine. Dei campioni revisionati dal personale medico il 76% ha richiesto la valutazione della formula leucocitaria, l’9% la revisione per sospetta presenza di schistociti e il 20% per la ricerca di aggregati piastrinici, con una media giornaliera di 26 vetrini. Conclusioni: Il sistema di regole di auto validazione, introdotto da Gennaio 2012 con il nuovo software, ha permesso una riduzione del numero degli emocromi da rivisitare pur mantenendo la stessa efficienza di screening del passato e l’integrazione del lavoro del personale tecnico e medico nel rispetto delle professionalità specifiche. biochimica clinica, 2012, vol. 36, n. 6 G. Introcaso, A. Cavallero, M. Raggi, T. D'errico, A. Ratto, D. Riggio, M. Rossi 1 C. Parma , F. Cappellini , G. Limonta , S. Signorini , P. 2 Brambilla 560 P178 PERFORMANCE DELL'EMOCITOMETRO SYSMEX XE 2100 NELLA RILEVAZIONE DEGLI AGGREGATI PIASTRINICI U.O. di Medicina di Laboratorio, Centro Cardiologico ''Monzino'', Milano Introduzione: I conteggi piastrinici effettuati con gli attuali sistemi analitici possono essere inaccurati e gli aggregati piastrinici causare conteggi sottostimati. La validazione tramite regole automatizzate di rilevazione aggregati è adottata nella routine di laboratorio. Scopo del presente studio è verificare le performance analitiche per la rilevazione degli aggregati piastrinici tramite software Dasit management system (DMS). Materiali e metodi: Sono stati estratti dal DMS i risultati di 414 campioni positivi per la regola di ricerca degli aggregati piastrinici (PLT 03) analizzati su Sysmex XE 2100 in un periodo di due anni. Tale regola valuta la presenza di cluster caratteristici per gli aggregati almeno in uno dei seguenti canali: canale DIFF, canale IMI, canale NRBC con conteggio piastrinico inferiore a 130(x10exp9/ L). Tutti i campioni sono stati analizzati secondo gli emogrammi completi compreso lo scattergram del canale WBC/BASO. Sono stati inoltre eseguiti gli strisci ematici per la ricerca degli aggregati piastrinici su vetrino. Abbiamo valutato la sensibilità della regola (PLT 03) = Vp/(Vp+Fp) in riferimento a due gruppi di pazienti: (a) cure intensive/postoperatorie (N= 261) e (b) degenza/ ambulatoriali (N= 153). Risultati: La regola (PLT 03) ha dimostrato una sensibilità del 9.8% per il gruppo (a) e dell’86.6% per il gruppo (b). Tale differenza è dovuta alle caratteristiche dei campioni del gruppo (a): alti e patologici conteggi WBC con frammenti cellulari che causano un elevato numero di falsi positivi Fp=138, rilevati nel canale DIFF. La comparazione dei dati dei canali Diff e IMI ha mostrato che lo scattergram del canale IMI è il più efficace nella rilevazione degli aggregati PLT, come confermato allo striscio ematico periferico, con sensibilità analitica uguale al 100% (N=111). Abbiamo trovato inoltre come interferenti filamenti di fibrina e frammenti tissutali(N= 98). Conclusioni: La regola (PLT 03) del DMS è utile per lo screening dei campioni ematologici. Richiede tuttavia implementazione tramite modifica della regola su canale IMI e gating automatizzato sui cluster specifici per gli aggregati piastrinici. Wu W, Guo Y, Zhang L, et al. Clinical utility of automated platelet clump count in the screening for ethylene diamine tetraacetic acid-dependent pseudothrombocytopenia. Chin Med J 2011;124:3353-7. 44° Congresso Nazionale SIBioC - Riassunti Poster P179 PERFORMANCE EVALUATION OF DM BODY FLUID SOFTWARE MODULE USING THE AUTOMATED DIGITAL CELL MORPHOLOGY ANALYZER CELLAVISION DM96 P180 PRIMA VALUTAZIONE DEL NUOVO STRUMENTO DI ELETTROFORESI CAPILLARE CAPILLARYS II FLEX PIERCING (SEBIA) PER LO SCREENING DELLE EMOGLOBINOPATIE SU SANGUE DI CORDONE OMBELICALE B. Peruzzi, R. Caporale, A.M.G. Gelli, A. Fanelli 1 Laboratorio Generale, AOU-Careggi, Firenze Background: Differential count and morphological analysis of nucleated cells in body fluids (BF) (eg, cerebrospinal (CSF), ascitic (AF), pleural (PlF), pericardic (PeF), synovial (SF) is very useful to the clinician. We evaluate the use of the Sysmex XE-5000 hematology analyzer in combination with the CellaVision DM96, an automated digital cell morphology system with BF application, for cell differential count in BF. Methods: A total of 40 body fluids samples (10 CSF, 12 AF, 16 PlF, 1 SF, 1 PeF) were analysed with the XE-5000 to obtain cell count and WBC differentiation into Mononuclear (MN) and Polymorphonuclear (PMN) cells. A cytospin preparation (Cytofuge2, Iris Int.) were performed using 250-300 ul of a cells suspension (20 cells /ul) to obtain a cell pellet of approx. 5000 cells; slides were left to air-dry and stained with the Wright-Giemsa method. Slides were analyzed using the DM96. PMN% and MN% reported by the XE-5000 were compared with PMN% (Neutr.+Eos.) and MN% (Lymph.+Mono/Macroph.) obtained at the DM96 after cells re-classification. Statistical analysis was performed by Pearson correlation and by Bland-Altman plot. % of Other cells classified with the DM96 (eg. Mesothelial, Tumor cells) were compared by Spearman correlation with % HF (High Fluorescence cells) reported by the XE-5000. Results: The comparison between XE-5000 and DM96 show very good correlation for PMN% (r=0,97; p<0,0001) and MN% (r=0,96; p<0,0001). The Bland-Altman plot (mean bias; 95% IC) shows no significant differences for MN% (-1,37; -4,34 to 1,60; p=0,36). A slight positive bias of the XE-5000 (3,71; 0,87 to 6,54; p=0,032) was observed for low PMN counts. HF-BF% shows a significant correlation with Other cells (r=0,50; p=0,0011). Conclusions: From our experience the use of the XE-5000 in combination with the DM96 can significantly improve automation and standardization in the diagnostic workup of body fluids analysis. Furthermore, DM96 represents a valuable tool to increase diagnostic accuracy, overall quality in morphological analysis, documentation of analysis results (digital archiving) and of the identification of the responsibility of slide interpretation. 1 1 2 G. Avveduto , M. Brogi , A. Caldini , S. Urbani , A. 1 1 1 1 Terreni , T. Biagioli , G. Grandi , A. Moscarella , V. 1 1 2 1 Ercoli , L. Reggiani , M. Santosuosso , G. Messeri 1 Laboratorio Generale, Dipartimento Diagnostica di Laboratorio, Azienda Ospedaliero Universitaria Careggi, Firenze 2 Banca del Cordone Ombelicale, Dipartimento Biomedicina, Azienda Ospedaliero Universitaria Careggi, Firenze Il sangue cordonale (CB), ricco di cellule staminali ematopoietiche, viene impiegato da oltre 20 anni a scopo di trapianto allogenico in malattie ematologiche, immunologiche e metaboliche. Secondo gli Standard Internazionali NetCord FACT (IV ed, 2010), l’idoneità al trapianto di una sacca di CB, è garantita da uno studio dell’assetto emoglobinico che escluda la presenza delle più comuni Hb varianti (S, C, D e E) e di talassemia major. Lo screening, da anni impiegato in paesi con consolidata realtà multietnica, è diventato di crescente rilevanza clinica in Italia. Sono state valutate le performances dello strumento Capillarys 2 Flex Piercing, (SEBIA) confrontando i risultati ottenuti (metodo Screening Cord Blood) con quelli ottenuti in HPLC (Dual Kit, Variant II, Biorad), in termini di imprecisione, correlazione e sensibilità di rivelazione di HbS. L’imprecisione è stata valutata ripetendo per 6 giorni 5 aliquote di CB conservate a -80°C (protocollo NCCLS EP5-A2), ottenendo un CVtot (HbA) di 1.56% in HPLC e 1.30% in CE. La presenza di talassemia viene valutata dalla % di HbA, in quanto la sintesi di HbA2 non è ancora sufficiente per la sua quantificazione. Sono stati quindi analizzati in parallelo 50 campioni di CB: l’analisi statistica dei risultati ottenuti per HbA (regressione di Deming) evidenzia un coefficiente 2 angolare di 1.17 ed un’intercetta di 1.29 con un r = 0.976. L’analisi di Bland-Altman mostra una differenza media di +4.42%, tale differenza sistematica è dovuta alla mancanza di calibrazione di HbA, rendendo necessario stabilire intervalli di riferimento metodo specifici. La rivelazione di varianti emoglobiniche in eterozigosi su CB richiede una buona capacità separativa e una notevole sensibilità dato che la sintesi delle catene beta è ancora scarsa (Hb F 80% circa). Un campione di sangue di adulto con HbS in omozigosi (privo di HbA) è stato diluito serialmente con CB: la sensibilità di rilevazione di HbS è risultata dello 0,2% in HPLC e dello 0.8% in CE. Le prove effettuate su HbS hanno dimostrato un’eccellente sensibilità della CE nella rivelazione della più comune tra le varianti emoglobiniche. Sebbene questi dati debbano essere confermati su un numero più ampio di campioni e per le altre emoglobine varianti comuni, il nuovo strumento SEBIA sembra essere adeguato per lo screening su CB. biochimica clinica, 2012, vol. 36, n. 6 561 44° Congresso Nazionale SIBioC - Riassunti Poster P181 SMUDGE CELLS IDENTIFICATION IN CLL PATIENTS USING AUTOMATED MICROSCOPY CELLAVISION DM96 P182 STUDIO PRELIMINARE DI CORRELABILITA’ TRA DUE METODICHE PER LA DETERMINAZIONE DELLE FRAZIONI DI HbA2 E HbF B. Peruzzi, A. Fanelli, R. Caporale, A.M.G. Gelli A. Amato, D. Zei, D. Ponzini, P. Di Biagio, E. Melis, O. Sarra, D. Gianni Laboratorio Generale, AOU-Careggi, Firenze Background: Blood films from CLL patients show characteristic smudge cells (or basket cells or Gumprecht's shadows) were initially considered as artefact of slide preparation; their formation were later demonstrated to be related to the content of cytoscheletal proteins present in CLL cells. Recent literature demonstrate smudge cells index (SCI) as an independent predictor of overall CLL patients survival. Introduction of virtual microscopy have been demonstrate to offers advantages to blood smear examination: we evaluate the performance of the CellaVision DM96, an automated digital cell morphology analyzer, to enable smudge cells identification in previously untreated CLL patients. Methods: 33 samples from patients suspected to have CLL (multicolour flow cytometry with a panel of antibodies including CD19, CD20, CD22, CD5, CD23, CD38, CD79b, FMC-7, CD200, sKappa/sLambda light chain and CD45 was used to confirmer the diagnosis) and 67 normal donor samples were obtained from the routine workload. WBC analysis of all samples was assessed with the Sysmex XE-2100 cell counter. All blood smears were prepared using the automated slide maker and stainer Sysmex SP-1000 and finally analyzed using DM96 system set to analyse 200 WBC. Results: We calculated SCI on blood smear of all the samples using the ratio between smudge cells/smudge cells + intact lymphocytes. The SCI in CLL patients is not correlated to sex and age and there was no correlation of SCI with absolute lymphocyte count (r= 0,29; p-value= 0,1076) or with lymphocyte percentage (r=0,05; p-value= 0,7789). The median SCI was significantly elevated in CLL patients (median of 33,3%; range: 9,3-69,1 %) compared to normal donor (median of 11,8% range: 3,8-29,4%) with a p-value <0,0001. Moreover SCI was significantly lower in CD38+ patients (median of 17,3%; range: 10,3-33,3%) when compared with CD38- patients (median of 48,8%; range from 9,3% to 69,1%) with a p-value=0,0056. Conclusions: Our investigation indicates that DM96 Digital Morphology Analyzer allows to obtain a good agreement between our results and the study published by Nowakowski et al (JCO 2009;27;11 1844-1849) in the estimation of SCI giving the possibility to improve quality assurance, transferability of results, and traceability of the method. 562 biochimica clinica, 2012, vol. 36, n. 6 A.N.M.I. Onlus - Centro Studi Microcitemie Roma, Italia Il Centro Studi Microcitemie di Roma si occupa da oltre 40 anni di prevenzione e diagnostica di talassemie ed emoglobinopatie. La determinazione delle frazioni di HbA2 e HbF, parametri molto significativi ai fini diagnostici, viene effettuata quotidianamente su pazienti inviati al nostro centro utilizzando prevalentemente una strumentazione in HPLC. In questo studio preliminare, effettuato su un ristretto gruppo di pazienti, abbiamo voluto confrontare i risultati ottenuti per i valori di HbA2 e HbF con quelli ottenuti utilizzando uno strumento di nuova commercializzazione la cui metodica si basa sull’elettroforesi capillare al fine di valutarne l’accuratezza. Questa stessa metodica è stata inoltre utilizzata per valutare la capacità e la precisione nel riconoscere e quantificare frazioni emoglobiniche anomale quando presenti. Un pool di 100 campioni di sangue intero prelevati random da pazienti dell’ambulatorio, preliminarmente analizzati come di routine in HPLC con strumentazione Variant II (Bio Rad Laboratories), sono stati successivamente esaminati in elettroforesi capillare utilizzando MINICAP Flex Piercing (Sebia). I risultati ottenuti sono stati messi a confronto utilizzando il coefficiente di correlazione di Pearson. Non avendo riscontrato la presenza di varianti emoglobiniche nel pool di pazienti considerato, in un momento successivo sono stati accuratamente selezionati alcuni campioni in cui l’HPLC aveva già rilevato tali emoglobine. L’analisi dei risultati ottenuti con le due metodiche ha evidenziato un coefficiente di correlazione di 0,987 per l’HbA2 e 0,980 per l’HbF. Questi valori sono indice di una correlazione molto forte. I cromatogrammi ottenuti dalle due metodiche da campioni con varianti emoglobiniche hanno evidenziato entrambe le diverse frazioni presenti mostrando una buona corrispondenza sia a livello qualitativo che quantitativo. In questo studio preliminare si può quindi ritrovare una sostanziale sovrapponibilità tra i risultati acquisiti con le due diverse strumentazioni. 44° Congresso Nazionale SIBioC - Riassunti Poster P183 VALUTAZIONE NRBC IN SOGGETTI TALASSEMICI CON I SISTEMI SYSMEX XE-2100 E ADVIA-2120I 1 1 1 S. Buoro , M. Vavassori , P. Gherardi , R. 1 1 1 1 Gustinetti , C. Saleri , E. Lochis , P. Dominoni , A. 2 2 2 1 Falanga , M. Marchetti , A. Trinchera , A. Crippa P184 WHITE BLOOD CELL ANALYSIS (WBC DIFFERENTIAL COUNT) IN BODY FLUIDS: COMPARISON BETWEEN THE SYSMEX XE5000 AND MANUAL FLOW CYTOMETRY B. Peruzzi, A.M.G. Gelli, A. Fanelli , R. Caporale Laboratorio Generale, AOU-Careggi, Firenze 1 Lab. Analisi Chimico Cliniche, Az. Osp. Ospedali Riuniti Bergamo 2 Servizio di Immunoematologia e Medicina Trasfusionale, Az. Osp. Ospedali Riuniti Bergamo Scopo: Nel sangue periferico (SP) di pazienti talassemici (TAL) è nota la presenza di eritroblasti (NRBC) e questa sembra essere correlata ad un’eritropoiesi inefficace. Nella moderna organizzazione di Laboratorio il conteggio NRBC in microscopia ottica (MO) su striscio di SP è di scarsa praticabilità per i tempi richiesti e le risorse dedicate. Gli analizzatori ematologici di ultima generazione sono dotati di diversi metodi di conta degli NRBC caratterizzati da rapidità e precisione. Obiettivo di questo studio è la comparazione del conteggio NRBC fornito da Sysmex XE-2100 e ADVIA-2120i verso MO in tre categorie di pazienti: ß-TAL, Trait-TAL e Controlli. Metodi: 49 campioni di SP raccolto in EDTA (29 ß-TAL, 7 Trait-TAL, 13 Controlli) sono stati analizzati con XE-2100 e ADVIA2120i. Il conteggio NRBC è stato confrontato con il metodo di riferimento (conteggio manuale in MO effettuato da due operatori secondo LG H20-A2). La concordanza tra la media dei conteggi manuali e l’automazione è stata valutata con regressione lineare (coefficiente r) e Bias di Bland-Altman, l’accuratezza diagnostica con analisi curve ROC. Risultati: Il confronto rispetto al conteggio NRBC in MO 2 ha fornito i seguenti risultati: per XE-2100 R =0.994, Bias –2.61(IC95% da –4.88 a –0.34), Concordanza 98%, Sensibilità (SE) e Valore Predittivo Negativo (VPN) 100%, Specificità (SP) 96.2%, Valore Predittivo Positivo VPP 95.8% a un cut-off NRBC≥0,9%. Per ADVIA 2120i 2 R ==0.949, Bias –5.80 (IC95% da –9.83 a –2.33), Concordanza 73.5%, SE 43.5%, VPN 66.7%, SP e VPP entrambi del 100% a un cut-off NRBC≥2%. Conclusioni: I risultati ottenuti su questa popolazione critica di soggetti indicano performance diagnostiche superiori di XE-2100 con il canale di conteggio degli NRBC attivato rispetto ad ADVIA-2120i. L’impiego di ADVIA 2120i su queste popolazioni selezionate implica la necessaria costruzione di algoritimi diagnostici che prevedano opportuni reflex test, sfruttando i possibili parametri di ricerca forniti dallo strumento, al fine di migliorarne le perfomance analitiche e diagnostiche. Danise P, Maconi M, Barrella F, et. al. Evaluation of nucleated red blood cells in the peripheral blood of hematological diseases. Clin Chem Lab Med 2011;50:357-60. Background: Accurate and rapid analysis of body fluids (BFs) are important for the diagnosis and treatment of several disease. Manual microscopy is the “gold standard” for quantification and differentiation of WBC in BF but this method is time-consuming and has a high imprecision. Aim of this study was to evaluate the Sysmex XE5000 hematology analyzer in WBC differential on BFs obtained from routine workload. Methods: WBC differential and count cells of a total of 43 BFs (5 cerebrospinal, 23 ascitic, 15 pleural fluids) were performed on the XE5000 using the dedicated BF mode. Flow cytometry (CFM) analysis of all samples was assess in a FACS Canto II using moAb CD45 FITC; the analysis was performed using a gate strategy of a combination of side scatter (SSC) vs CD45 expression to differentiated granulocytes (PMN) from monocytes/macrophages and lymphocytes (MN). Debris were excluded by eliminating all the events that were smaller than lymphocytes. We compared: 1. % MN and % PMN XE5000 vs % MN and % PMN CFM (SSC vs CD45); 2. %WBC XE5000 vs %WBC CFM (CD45+); 3. %HF_TC XE5000 vs % NO WBC CFM (CD45-). Statistical analysis was performed by Pearson correlation and by Bland-Altman plot. Results: The comparison between XE5000 and CFM show very good correlation for: 1. PMN% (r=0,90; p<0,0001); mean bias -2,30 (95% IC from -5,02 to 0,41; p-value=0,0944); 2. MN% (r=0,91; p<0,0001); mean bias 1,77 (95% IC from -0,81 to 4,35; p-value=0,1741); 3. WBC% XE vs %WBC CFM (CD45+cells): r=0,89; p value <0,0001; mean bias -1,25 (95% IC from -2,73 to 0,23; p-value=0,0961); 4. %HF_TC XE vs % NO WBC CFM (CD45- cells): r=0,89; p-value<0,0001; mean bias 1,25 (95% IC from -0,23 to 2,73; p-value=0,0961). All those analysis shown no significant differences. Conclusions: Our works demonstrate that the BF mode of the Sysmex XE5000 is a suitable tool for a rapid and reliable screening of WBC differential counts in BF analysis, providing also a good discrimination between WBC and non WBC cells. biochimica clinica, 2012, vol. 36, n. 6 563 44° Congresso Nazionale SIBioC - Riassunti Poster P187 ELIA IMMUNOCAP AVIDITY DETERMINATION OF IGG ANTI BETA2-GLYCOPROTEIN I ANTIBODIES IN PATIENTS WITH AND WITHOUT ANTIPHOSHOLIPID SYNDROME 1 1 2 3 B. Montaruli , C. Marchese , S. Stella , A. Kuzenko , A. 2 3 2 1 Vaccarino , M.T. Bertero , M. Bazzan , M. Migliardi 1 Laboratory Analysis, AO Ordine Mauriziano - Turin CMID-University of Turin, Torino Nord Emergenza San Giovanni Bosco Hospital 3 Immunology Department AO Ordine Mauriziano - Turin P188 EVALUATION OF A NEW QUANTITATIVE HIGHLY SENSITIVE LATEX D-DIMER (Dd) ASSAY IN PATIENTS WITH CLINICALLY SUSPECTED DEEP VEIN THROMBOSIS (DVT) C. Legnani, M. Cini, M. Sartori, B. Cosmi, G. Palareti Dept. Angiology and Blood Coagulation “Marino Golinelli”, University Hospital S. Orsola-Malpighi, Bologna, Italy 2 Background: Anti-B2-glycoprotein I antibodies (aB2-GPI), one of the subgroups of antiphospholipid antibodies (aPL), present a huge heterogeneity due to epictopic specificity, involvement in pathogenesis and avidity. The objective of our study was to evaluate avidity of IgG aB2-GPI in patients with and without Antiphospholipid Syndrome (APS) by using EliA ImmunoCAP chaotropic determination. Materials and methods: 28 patients with primary and/ or secondary APS (17 out of 28) and with autoimmune or infection diseases (11 out of 28) were studied by evaluating LA, anticardiolipin (aCL) EliA immunoassay, aB2-GPI EliA (ImmunnoCAP) and ELISA (Varelisa) immunoassays and IgG aB2-GPI chaotropic ELISA (Varelisa) and EliA (ImmunoCAP) assays. Results: Good agreement was found between ELISA and EliA chaotropic avidity assays (k = 0.88). 7 and 21 patients had respectively high and low EliA chaotropic avidity. All the patients with high avidity had APS while no subjects with high avidity were found in autoimmune/ infectious patients group (p <0.05). The most common clinical APS feature among patients with high avidity aB2-GPI was vascular thrombosis (6 vascular thrombosis and 1 pregnancy morbidity, p = 0.31), in all cases due to venous thrombosis (6 venous thrombosis and 1 pregnancy morbidity, p = 0.36). Conclusions: EliA chaothropic is as suitable as ELISA assay for the determination of aB2-GPI avidity but fully automated and easier for basic/routine laboratories. In our preliminary study high aB2-GPI avidity was associated with clinical features of the syndrome (mainly venous thrombosis) while in patients with autoimmune/infection diseases low avidity prevailed. Determination of aB2-GPI avidity should be considered for clinical differentiation of patients with aB2-GPI. Cucnik S, Kveder T, Artenjak A, et al. Avidity of anti-ß2glycoprotein I antibodies in patients with antiphospholipid syndrome. Lupus 2012;21:764-5. Dd testing is widely used in conjunction with clinical pretest probability (PTP) for venous thromboembolism (VTE) exclusion. In patients presenting negative Dd and low/intermediate PTP, VTE can be excluded without performing imaging tests. However, each Dd assay should be validated in prospective outcome studies before clinical use. We report on the evaluation of a new, automated, latex turbidimetric immunoassay for Dd measurement, the Sclavo Auto D-Dimero (Sclavo Diagnostics Int.), provided by Dasit. Consecutive patients referred to our outpatient clinic for suspected leg DVT were included. The exclusion criteria were: previous DVT event, symptoms lasting > 15 days, anticoagulant treatments already underway at presentation, pregnancy. Patients were classified as DVT positive/negative according to the results of the following diagnostic work-up: PTP, Dd and compression ultrasound (CUS) to assess proximal DVT, to be repeated after 5-7 days in patients with negative initial CUS and high PTP or altered Dd. Negative patients received a phone call after 3 months. The PTP (high/moderate/low) was evaluated using the Wells score. Dd levels were measured by the STA Liatest (Diagnostica Stago). Plasma aliquots were frozen for further analysis. The new Dd assay was evaluated on two analyzers (Sysmex CA-7000 and Sysmex CS-2100, provided by Dasit). Only patients with low/intermediate PTP were included. Plasma of 300 patients was tested. The DVT prevalence was 11.3%. The cut-off level providing the highest sensitivity was 200 ng/mL. Since no false negative patients were detected, the sensitivity and negative predictive (NPV) values were 100% [sensitivity = CA-7000: 100% (95%CI: 90-100), CS-2100: 100% (95%CI: 90-100); NPV = CA-7000: 100% (95%CI: 98-100), CS-2100: 100% (95%CI: 98-100)]. Specificity was 65% (95%CI: 59-71) and 69% (95%CI: 63-75) for CA-7000 and CS-2100, respectively. The reproducibility of the assay was good being the total CVs < 10% for Dd level around the cut-off value. In conclusion, the Sclavo Auto D-Dimero assay proved to be accurate when used for DVT diagnostic work-up in outpatients. Based on 100% sensitivity and NPV and lower limit of the 95% CI higher than 90% and 95%, respectively, it can be used as a stand-alone test in patients with low/moderate PTP. biochimica clinica, 2012, vol. 36, n. 6 565 44° Congresso Nazionale SIBioC - Riassunti Poster P189 LMWH ANTI XA ACTIVITY IN SELECTED POPULATIONS P190 VALUTAZIONE DI UN NUOVO APPARECCHIO AUTOMATICO PER LA COAGULAZIONE, COAG30 S. Testa, O. Paoletti, A. Zimmermann , L. Bassi, E. Cancellieri, A. Cogrossi, S. Zambelli R. Canonico, D. Ercolini, A. D'Antonio, C. Alone, E. Paone, L. Atripaldi Haemostasis and thrombosis center- clinical pathology division - Azienda Istituti Ospitalieri - 26100 Cremona Laboratorio di Analisi Ospedale D. Cotugno, Napoli Background: Anti-Xa activity (aXa) can be used as biological marker of LMWH, but aXa routine monitoring is not recommended. Anyhow, anti-Xa monitoring could be indicated in selected conditions. Aim: Describe the incidence of aXa levels out of range, both in prophylaxis and in therapeutic regimen, in special populations (pregnancy, renal disease, over/under weight and in elderly/critical patients), treated with enoxaparin for at least two weeks. Material and methods: We retrospectively analyzed data collected during 2011. 373 aXa activity were performed on patients treated with enoxaparin at standard or adjusted dose. 252 determinations were on patients treated with therapeutic and 121 with prophylactic regimen. Blood samples were collected after 4 hours from the last LMWH injection, in patient treated at least from 2 days. AXa was measured by Stago Rotachrom chromogenic assay on STA-R . Results: Out of range aXa levels were 38% and 34% of the total therapeutic and prophylaxys regimen, respectively. We found a reduction in out of range in population treated with adjusted doses in comparison with standard regimen. Conclusion: Out of range aXa levels are frequently observed both in prophylaxis and in therapeutic regimen in special patient populations. AXa could guide LMWH dose adjustment to improve the maintenance of prophylaxis/ therapeutic levels, avoiding dangerous out of range. 566 biochimica clinica, 2012, vol. 36, n. 6 Lo scopo del lavoro è quello di valutare nel nostro Laboratorio le performances dell’apparecchio automatico Coag30 per coagulazione della Medical Systems prodotto dalla TND Elettronica su progetto e collaborazione esperta della ICD&Partners. La valutazione della qualità analitica di questo strumento ha previsto la correlazione con il nostro apparecchio ACL Advanced ed utilizzo di due tromboplastine Recombiplastin lotto EO315307 ISI 0,91 della IL e Thromboplastin Li Lotto 10929288 ISI 1.12 della Helena utilizzate sugli apparecchi ACL n 05121348 della IL e Coag30 n 10019 della Medical Systems mantenendo medesime caratteristiche di lavoro valutando ripetibilità DV CV tempo di decadimento della Tromboplastina. Su entrambi gli apparecchi è stato fatto MNPT da plasmi freschi normali, le calibrazioni sono state fatte sia dal MNPT che da plasmi riferimento esprimendo tempi concentrazioni e INR in base all’ISI delle tromboplastine sopra indicate. La curva di calibrazione eseguita sulla macchina ACL Advanced IL ottenuta con con la Tromboplastina Helena rispetto a quella ottenuta con Ricombiplastin IL risulta meno dolce, troppo ripida e non permette anche su valori percentuali alti differenze di tempi significative tra varie concentrazioni determinando un errore sulla ripetibilità e sul calcolo dell'INR. La calibrazione con il SARP Plasma di riferimento Helena eseguita con Thomboplastin Helena ha dato risultati analoghi a quelli ottenuti con MNPT dei plasmi freschi. Con i plasmi freschi è stato preparato un pool congelato analizzato per 20 giorni 10 volte al giorno sia sull'apparecchio Coag che su IL. Quando è stata utilizzata il Ricombiplastin entrambe le macchine si sono comportate in modo identico mostrando un CV 2% a differenti livelli di attività e concentrazioni utilizzando la Tromboplastina Helena i CV sono risultati maggiori del 5% evidenziando gli stessi problemi di ripetibilità e conservazione dovute all’alta torbidità e mancanza di stabilità pur avendo applicato una forzata e continua agitazione del reagente. I risultati di correlazione tra i due apparecchi sono validi mostrando valori di R tra 0,978 e 0,989. 44° Congresso Nazionale SIBioC - Riassunti Poster P191 A CASE OF KETONE BODIES POSITIVE INTERFERENCE IN THE TRINDER METHOD FOR SALICYLATE MEASUREMENT P192 A SIMPLE TOXICOLOGICAL ANALYSIS OF ANABOLIC STEROID PREPARATIONS FROM THE BLACK MARKET C. Lo Cascio, M. Bertolani, B. Caruso, M.S. Graziani M. Pellegrini, M.C. Rotolo, R. Di Giovannandrea, R. Pacifici, S. Pichini Lab. Analisi dO, Az. Ospedaliera Universitaria Integrata Verona Introduction: In the diagnostic pathway of paediatric acute metabolic acidosis, salicylate intoxication is sometimes considered. We report here a case of a young child with marked ketosis, due to a genetic metabolic disorder, with a false positive result in salicylate determination. Methods: An 11 month old child, presented to paediatric emergency unit with important ketoacidosis. Salicylate was determined with SAL reagent (Siemens) applied on Dimension Vista (Siemens) according to the manufacturer instructions. The method is based on the Trinder method and uses the reaction between salicylate and Fe-nitrate to form a coloured complex. Samples from blood donors were spiked with sodium salt of 2-ketobutirric acid (Aldrich). Results: Serum samples from the patient gave persistent positive results, showing values slowly decreasing as the clinical situation improved (60 mg/L, 54 mg/L, 34 mg/L, <17 mg/L). Since parents firmly denied salycilate ingestion, samples were tested with an immunoenzymatic method and resulted negative. Salicylate measurements on blood donor samples spiked with 2-ketobutirric acid, showed results positively correlated with the amount of the added substance. Discussion: Ketone bodies interference with Trinder method has been already reported, but it is not specifically mentioned in the manufacturer reagent sheet. It is important to be aware of this positive interference because it can cause a delay in the diagnosis or treatment of a ketoacidosis or rise doubts on the capacity of parents to create a safe environment for their children. Tilbrook LK, Slater J, Agarwal A, et al. An unusual cause of interference in a salicylate assay caused by mitochondrial acetoacetyl-CoA thiolase deficiency. Ann Clin Biochem 2008;45:524–6. Department of Therapeutic Research and Medicine Evaluation, Istituto Superiore di Sanità, Rome, Italy Anabolic steroids are synthetic substances related to the male sex hormones They have a number of physiological effects, most notably an anabolic effect that promotes the growth of skeletal muscle and androgenic effects that foster the development of male sexual characteristics. Abuse of anabolic steroids is motivated in most cases by a desire to build muscles, reduce body fat, and improve sports performance. Abuse is estimated to be very high among competitive bodybuildersand spread among elite and recreational athletes. After opening the borders to Eastern Europe an explosionof the black market for anabolic steroids occurred. During the last 10 years, numerous products that supposedly support athletic performance and muscle growth were obtained from different websites, but also confiscated in house searches. Several of those were identified as counterfeit substances Objectives: A simple and rapid gas chromatography (GC) method with mass spectrometry (MS) detectionwas developed for the identification and quantification of anabolic steroids in pharmaceutical preparations from the black market. Material and Methods: After a liquid-liquid extraction of pharmaceutical products at acidic, neutral andbasic pH with chloroform-isopropanol (9:1, v/v), the different steroids were separated by fused silica capillary column and detected by electron impact (EI)-MS in positive ionization mode. Results and conclusion: The assay was validated in the range from 10 mg to 250 mg/g powder preparations and 0.02 mg to 200 mg/mL liquid preparations with good 2 determination coefficients (r _ 0.99) for the calibration curves. At three concentrations spanning the linear dynamic ranges of the calibration curves, mean recoveries were always higher than 90% and intra-assay and inter-assay precision and accuracy were always better than 15%. This method was successfully applied to the analysis of 15 pharmaceutical preparations sold by illegal sources. In only two cases the content was the one reported on the labels. In the other cases, no substances at all, or steroids different from those reported on the labels or different amounts from those declared were found. biochimica clinica, 2012, vol. 36, n. 6 567 44° Congresso Nazionale SIBioC - Riassunti Poster P193 APPROCCIO ALLO SVILUPPO SPERIMENTALE DI UN METODO ANALITICO PER LA RICERCA DELL’ETILGLUCURONIDE (ETG) NELLA MATRICE CHERATINICA P194 CONFIRMATION OF CARBOHYDRATE-DEFICIENT TRANSFERRIN GENETIC VARIANTS BY CAPILLARY ZONE ELECTROPHORESIS IN A CLINICAL PATHOLOGY LABORATORY A. Peruzzini, F. Svaizer, M. Gottardi C. Canali , T. Trenti , G. Manieri , V. Galli , R. Bedin Lab. LIESP APSS Trento 1 Questo lavoro di applicazione del metodo per il dosaggio dell’EtG su una matrice cheratinica ha previsto la verifica della qualità di alcuni parametri quali la precisione, l’accuratezza, la sensibilità e la specificità per il suo utilizzo nello screening dei campioni. I risultati ottenuti relativamente ai parametri elencati sono stati soddisfacenti; solo la sensibilità non si è rivelata sufficientemente idonea al valore di cut-off suggerito di 30 pg/mg. Tale valore dovrà necessariamente essere aumentato al di sopra di 50 pg/mg, limite comunque da accertare. Nonostante siano state eseguite diverse prove per riuscire a discriminare i negativi dai positivi con un cut-off fissato a 30 pg/mg, ne saranno necessarie ulteriori di approfondimento per la validazione del metodo allo scopo di migliorare la sensibilità analitica aumentando la quantità del campione, oppure aumentando il cut-off allo scopo di diminuire i falsi positivi, senza però vanificare il tentativo di miglioramento delle altre prestazioni analitiche descritte. Con questo studio, infatti, si è riusciti a discriminare bene solo i campioni negativi da quelli la cui concentrazione di metabolita era superiore a 50 pg/ mg. Si è rivelato come punto critico in questo studio la disponibilità di un numero di campioni esiguo sul quale poter evidenziare con certezza la concentrazione dei campioni a livello prossimi al cut-off. Infatti, nonostante in Italia ci sia un abuso diffuso di alcol, è stato difficile trovare persone che abusano di alcol disponibili alla raccolta del campione. Sono state introdotte alcune modifiche sostanziali al metodo per quanto riguarda la preparazione del campione nella fase di lavaggio ed estrattiva. E’ stato verificato che, in virtù dell’alta polarità dell’EtG, anche l’H2O risulta un solvente idoneo per il lavaggio alla pari del diclorometano e metanolo. Si è deciso di utilizzare per l’estrazione del campione il solvente VMAT come per le droghe di abuso uniformando,quindi,la pratica di estrazione. E’ importante rilevare che a fronte di quantità notevole di EtG superiore a 280 pg/mg occorre intervenire con un’opportuna diluizione del campione per evitare l’effetto negativo dell’eccesso di Ag (effetto Hook). L’applicazione del metodo alla matrice cheratinica resta pertanto condizionato da ulteriori idonei approfondimenti. 568 biochimica clinica, 2012, vol. 36, n. 6 1 1 1 2 2 Lab. Tossicologia Clinica e Diagnostica Avanzata, Nuovo Ospedale Civile S. Agostino Estense, Modena 2 Dip. di Neuroscienze-Lab. Neuroimmunologia, Nuovo Ospedale Civile S. Agostino Estense, Modena Background: The detection of CDT, a marker for chronic alcohol abuse, is performed by chromatographic, electrophoretic and immunoassays methods, in this assay the presence of VG (genetic variant) may bring to misleading interpretations with false positives or negatives. IEF is recognized as the gold standard method to characterize and to classify the VG, however it is extremely laborious not suitable for routine use. Aim: Our aim is to confirm the presence and characterize VG in doubtful samples by capillary electrophoresis assay only, as routine technique, without IEF (isoelectric focusing) method. Methods: In our study we considered 85 patients: 49 patients whose electrophoretic profile was suggestive for VG presence and 36 patients whose profile was normal. Between the 36 normal patients we had 16 CDT positives ad 20 CDT negatives. These 85 samples were confirmed with IEF/Immunoblot using a specific antibody anti-transferrin (Dako). Further we investigated 39 samples classifyed as “ Non detectable CTD due to analytical interference” during the year 2011. All our samples (85+39) were tested by capillary electrophoresis (CZE) P/ACE MDQ Beckman Coulter using CEofix CTD Kit (Analis, Belgium), after neuraminidase (Clostridium perfringens, Sigma) digestion 24 h, 37°C, to eliminate the sialic acid residues from the protein chain. Results: The CZE analysis has confirmed the presence of VG in the group of 49 patients and has excluded in the group of 36. In the group of 39 patients were definitively detected 28 VG (71,8%): 6 CD and 22 BC. However 11 samples remained unexplained and non detectable as no sure interpretation was possible. Conclusions: Our study focuses on the fact that the only electrophoresis is not enough to evaluate the VG presence a crucial point due the legal implications of the CDT test. As it is necessary a confirmatory method to give clear and defendable results, the digestion with neuraminidase before coupled by CZE method could be suitable for routine purpose to set up in a clinical pathology laboratory. Wuyts B, Delanghe J, Kasvosve I, et al. Determination of carbohydrate-deficient transferrin using capillary zone electrophoresis. Clin Chem 2001;47:247-55. 44° Congresso Nazionale SIBioC - Riassunti Poster P197 INDAGINI DI LABORATORIO PER L’ASSOLVIMENTO DEGLI OBBLIGHI DI LEGGE DERIVANTI DALL’APPLICAZIONE DEL CODICE DELLA STRADA Art.186/187 P. Bucchioni, F. Evangelisti , M. Vignali , G. Petricciani , I.M. Sbarbaro Lab. Analisi Osp. S.Bartolomeo Sarzana Sez. Tossicologia Il Codice della Strada riporta i protocolli operativi per gli accertamenti delle sostanze d’abuso: art 186 e 187 del DL 30.4.1992 n. 285, rispettivamente per alcool e droga. Per soddisfare queste esigenze operative, nel 2010, abbiamo studiato, condiviso e reso operativo con la Prefettura di La Spezia un “ Protocollo tossicologico-codice stradale”,con la finalità di disciplinare e razionalizzare il servizio in oggetto, in piena osservanza della normativa vigente. Ciò ci ha permesso di seguire tutte le procedure previste: dall’attivazione della “catena di custodia” fino alla conferma dei risultati con indagini di “secondo livello” in spettrometria di massa, allo scopo di produrre un referto finale proprio conforme e sostenibile in sede amministrativa e/o giudiziaria. Ed è proprio questo il punto più critico e al contempo più qualificante: superare il valore indiziario degli esami di screening (I livello) su urine, per raggiungere il valore probatorio delle conferme (II livello) su sangue. A tal fine, andremo a valutare uno studio retrospettivo che va a dimostrare come il percorso virtuoso che inizia con gli aspetti formali del “consenso informato” e della “catena di custodia” e giunge al raggiungimento della certezza di guida sotto effetto di sostanze stupefacenti e/o di alcool, abbia portato a partire dall’applicazione dell’accordo con la Prefettura (luglio 2010), un decremento significativo dei risultati positivi a fronte di un incremento dei controlli effettuati. Nelle tabelle che verranno esposte nel poster sono riportati i risultati analitici di tale studio. Dall’osservazione dei nostri dati emerge la necessità di rendere omogenei e corretti i percorsi operativi che la Legge ci impone. In altri termini gli operatori chiamati ad espletare tali indagini, sono tenuti ad implementare un iter procedurale che sia aderente alla normativa vigente con due scopi entrambi irrinunciabili: fornire all’autorità giudicante le prove di condotta di guida illecita ed, al contempo, garantire la non punibilità per i conducenti che non hanno commesso il fatto 570 biochimica clinica, 2012, vol. 36, n. 6 P198 MAGIC TRUFFLES OR PHILOSOPHER’S STONES: A LEGAL WAY TO SELL PSILOCYBIN? 1 1 1 1 E. Marchei , M. Pellegrini , M.C. Rotolo , S. Pichini , R. 1 2 Pacifici , F. Saggio 1 Department of Therapeutic Research and Medicines Evaluation, Istituto Superiore di Sanità, Rome, Italy 2 Comando Carabinieri per la Tutela della Salute, Rome, Italy Introduction: “Magic mushrooms” is the most common name given to hallucinogenic fungi containing the psychoactive alkaloids psilocybin and psilocin. In recent years, “magic truffles” have become a new form of supply of psychoactive Psilocybe alkaloids, since Psilocybe sclerotia are not specifically included in the laws banning the sale, the purchase and the use of such substances and mushrooms containing them. Methods: A liquid chromatography –tandem mass spectrometry (LC-MS/MS) method was developed for the rapid determination of psilocybin and psilocin in Psilocybe sclerotia. Following a simple step extraction with methanol, the alkaloids were separated on a reversed-phase column using a gradient of 0.1% formic acid – acetonitrile s a mobile phase at a flow rate of 0.2 mL/ min. Separated analytes were detected by electrospray ionization tandem mass spectrometry in the positive ion mode using multiple reaction monitoring. Results: The developed method was linear over the calibration range for all two substances under 2 investigation, with a r 0.99. The detection and quantification limits were 0.3mg and 1mg per 100mg truffles, for both psilocin and psilocybin and the intraand inter-day coefficients of variation were always better than 15%. Using this method, the presence of only psilocybin was demonstrated in examined Psilocybe sclerotia. The content of psilocybin was found to vary over a concentration range of 59.3 to 167.8 mg per 100 mg truffles corresponding to 0.06-0.16% alkaloid per fresh sclerotia. Conclusion: The results of our analyses can be an incentive for the policy makers to include Psilocybe sclerotia in the list of controlled plants or herbal products that contain psychotropic alkaloids in the corresponding laws banning the sale, the purchase and the use of illegal drugs in European and non European Countries. 44° Congresso Nazionale SIBioC - Riassunti Poster P199 METABOLIC ALTERATIONS INDUCED BY METHACRILIC MONOMERS IN HUMAN PULPAR FIBROBLASTS P200 METODI IMMUNOMETRICI E HPLC-MS/MS A CONFRONTO NELLO SCREENING TOSSICOLOGICO 1 1 2 3 3 C. Callà , A. Lupi , M.L. Gozzo , L. Cicillini , B. 1 1 Giardina , G. Nocca 1 1 2 M. Marinova , C. Artusi , L. Brugnolo , G. Antonelli , M. 1 1 Zaninotto , M. Plebani 1 1 Laboratorio Analisi I, Policlinico A. Gemelli, Roma 2 Ist. Chimica Riconoscimento Molecolare CNR, Roma 3 Laboratorio Analisi, Osp. G. Vannini, Roma Aim: Composite resins were introduced in the 1960s for the restoring of anterior teeth in substitution of the amalgam that presented both aesthetical and biocompatibility problems. However, since the polymerization of methacrylates is never complete, the need to appraise the biocompatibility of composite resins became evident. The incomplete conversion causes in fact the release of monomers that may implement adverse effects in the organism, i.e. allergic reaction, systemic toxicity, cytotoxicity. Given that very little information has been so far delivered on the effects of methacrylic monomers on cell metabolism, the aim of this work was the evaluation of the biochemical interactions between methacrylates and human fibroblasts. Methods: The effects of triethylenglycol-dimethacrylate (TEGDMA), 2-hydroxyhethyl methacrylate (HEMA), and 1,4-butanediol dimethacrylate (BDDMA) on 1) cellular energetic metabolism (oxygen consumption rate, glucose consumption, G6PDH, lactate production) 2) cellular redox status (GSH concentration, the activity of the enzymes regulating glutathione metabolism and REDOX status of cells) were analysed according to Nocca et al. Data are expressed as the mean ± statistical error of the mean (SEM). The means were compared by analysis of variance (ANOVA) followed, when appropriate, by a multiple comparison of means by Student-Newman-Keuls test: p < 0.05 was considered significant. Results: The results showed that TEGDMA, HEMA and BDDMA induce a statically significant decrease of oxygen consumption, an enhancement of glucose consumption, lactate production and also GSH depletion. Conclusions: The alterations in energy metabolism, REDOX status and glutathione balance – produced in the cellular metabolism by HEMA, TEGDMA and BDDMA – can be considered among the mechanisms inducing the clinical and sub-clinical adverse effects that have been occasionally reported during the use of dental resins. In our opinion, such investigations can therefore be helpful to test the behavior of materials especially designed to be applied inside the human body. Nocca G, De Palma F, Minucci A, et al. Alterations of energy metabolism and glutathione levels of HL-60 cells induced by methacrylates present in composite resins. J Dent 2007;35:187-94. Dip interaziendale Azienda Ospedaliera-Università degli Studi, Padova Servizio Medicina di Laboratorio 2 Dip di Medicina, Università degli Studi di Padova Introduzione: Il laboratorio di Farmacotossicologia assume un ruolo importante nel Servizio Medicina di Laboratorio nella problematica delle sostanze d’abuso poiché deve essere in grado di produrre dati sostenibili sia scientificamente sia legalmente e garantire l’affidabilità di tutte le fasi del processo. Per tale motivo, la scelta delle metodologie più idonee rappresenta un impegno importante che il laboratorio deve garantire. Obiettivi: Valutare le prestazioni analitiche delle metodiche DRI (homogeneous enzyme immunoassay) e KIMS (Kinetic Interaction of Microparticles in a Solution), applicate su due diversi analizzatori automatici presenti in commercio, evidenziando le problematiche relative alla diversità di riconoscimento delle classi di sostanza come conseguenza dei diversi principi analitici e degli anticorpi presenti nei reagenti. Al fine di realizzare una valutazione più completa possibile è stata eseguita l’analisi di conferma mediante LC-MS/MS. Materiali e metodi: Sono stati analizzati 211 campioni di urine di pazienti afferenti al Servizio Medicina di Laboratorio con richiesta di screening tossicologico con pannelli differenziati. I campioni sono stati processati contemporaneamente con Cobas 6000 versione c501 e ILab Taurus. L’analisi di conferma è stata eseguita su i campioni con risultati discrepanti utilizzando il sistema HPLC-MS/MS Agilent 6430. Risultati: Anfetamine: KIMS 12 FP (12/166=7%); DRI 1 FN (1/166=0.6%) con un valore di poco inferiore al cutoff (1000 μg/L). Oppiacei: KIMS 9 FP (9/185=5%) e 3 FN (3/185=1,6%); DRI 1 FP (1/185=0.5%). Metadone: KIMS 14 FP (14/169=8.2%); DRI 1 FN (1/169=0.6%). Cannabinoidi: KIMS 5 FP (5/179=2.8%) e 1 FN (1/179=0.6%) con un valore ai limiti del cut-off (50 μg/ L); DRI 5 FN (5/179=2.8%) dei quali 3 campioni (1.7%) con un valore ai limiti del cut-off. Cocaina: DRI 1 FN (1/176=0.6%). Conclusioni: Dai dati ottenuti si evidenza una percentuale di discordanza tra metodi pari al 24% attribuibile principalmente al diverso principio di misura che privilegia la sensibilità (KIMS) o la specificità (DRI). Di conseguenza ogni laboratorio sulla base della popolazione di afferenza e della possibilità di eseguire il test di approfondimento dovrà scegliere la tecnologia di screening più adatta alla specifica realtà clinica. biochimica clinica, 2012, vol. 36, n. 6 571 44° Congresso Nazionale SIBioC - Riassunti Poster P201 MONITORAGGIO BIOLOGICO DELL’ESPOSIZIONE A GAS ANESTETICI: ESPERIENZA ASL-BR T. Voi, P. Robert, R. Incalza, M. Scoditti Lab. di Patologia Clinica distrettuale e Tossicologia "A. Di Summa", Brindisi Si definiscono anestetici quei farmaci che determinano una abolizione dello stato di coscienza ed una inibizione temporanea della sensibilità dolorifica limitatamente al periodo della loro somministrazione. Gli anestetici per inalazione sono distinti in due gruppi: gassosi e volatili. In riferimento alle linee guida sulla prevenzione e sicurezza nelle sale operatorie, il nostro laboratorio ha monitorato l’esposizione di lavoratori della ASL-BR al fine di valutare il rischio sanitario da esposizione a gas anestetici. Un’esposizione cronica a tali gas infatti produce effetti tossici a livello di diversi apparati (riproduttivo, epatico, emolinfopoietico). L’esposizione può essere dovuta a perdite di gas dalle apparecchiature per anestesia, comportamenti scorretti degli anestesisti, insufficiente manutenzione degli impianti e dei sistemi di aspirazione e convogliamento all’esterno dei gas, inadeguatezza dei sistemi di ricambio dell’aria. Il metabolismo di questi gas, ne consente il dosaggio urinario, infatti nel secondo trimestre 2012 sono stati analizzato campioni urinari provenienti da 18 lavoratori operanti nelle sale operatorie della asl br. I campioni sono stati prelevati all'inizio e alla fine del turno lavorativo e sono stati esaminati in Gas cromatografia con detector MS tramite l’impiego di una colonna cromatografia del tipo Poraplot Q. I risultati ottenuti hanno dimostrato che l’esposizione rientra nei limiti degli Indici Biologici di Esposizione per 16 campioni, mentre in due casi la concentrazione riscontrata risulta superiore. A conclusione del nostro studio, possiamo confermare l’importanza del monitoraggio biologico come sistema efficace di controllo nell'ambito della sorveglianza sanitaria. Mushlin PS, Mark JB, Elliott WR, et al. Inadvertent development of subatmospheric airway pressure during cardiopulmonary bypass. Anesthesiology 1989;71:459-62. Ozanne GM, Young WG, Mazzei WJ, et al. Multipatient anesthetic mass spectrometry. Anesthesiology 1981;55:62-70. Able M, Eisenkraft JB. Erroneous mass spectrometer readings caused by desflurane and sevoflurane. J Clin Monit 1995;11:152-8. 572 biochimica clinica, 2012, vol. 36, n. 6 P202 MONITORAGGIO DELL’ABUSO ALCOLICO E INTERAZIONE TRA FARMACI E TRASFERRINA CARBOIDRATO CARENTE: PRESENTAZIONE DI UN CASO CLINICO 1 2 1 1 M. Vidali , V. Bianchi , M. Bagnati , N. Atzeni , G. 1 Bellomo 1 Azienda Ospedaliero-Universitaria Maggiore della Carità e Università del Piemonte Orientale, Dip. di Scienze della Salute, Novara 2 Azienda Ospedaliera S.S. Antonio e Biagio e C. Arrigo, Alessandria Introduzione: Sebbene siano stati condotti numerosi studi per identificare potenziali fattori associati a false positività all’esame della Transferrina Carboidrato Carente (%CDT), il problema dei falsi negativi è stato valutato solo marginalmente. In questo lavoro riportiamo il possibile effetto della terapia farmacologica sui livelli di CDT in un paziente forte bevitore con storia clinica nota (lug 2007-apr 2012). Materiali e Metodi: XY maschio 70 anni. La concentrazione di CDT (%disialotransferrina, cut-off 2,0%) è stata misurata con “%CDT kit by HPLC” (BioRad) su HPLC 1200 Agilent. La concentrazione urinaria di etilglucuronide (EtG) è stata valutata su ADVIA 2400 (Siemens Healthcare) con kit DRI-EtG EIA (MicrogenicsThermo Fischer) (cut-off 0,5 mg/L). Risultati: Il paziente a fine 2007 presentava AST 137 U/L, ALT 120 U/L, GGT 434 U/L, MCV 101 fl e CDT 3,3%; a dic 2007 dopo intervento per duplice by-pass aorto-coronarico iniziava terapia con amlodipina, perindopril, atorvastatina, isosorbide mononitrato, carvedilolo, ticlopidina e pantoprazolo. Nei mesi successivi l’abuso progressivamente riprendeva; tuttavia, a dispetto di ciò che riferiva la famiglia, a lug 2009 presentava una CDT di 0,8%. A set 2009 il paziente veniva ricoverato per frattura di bacino a seguito di caduta (il tasso alcolemico dopo 16 h dal ricovero era 0,8 g/L). Su pressione della famiglia si sottoponeva a gen 2011 (senza preavviso) al test della CDT risultato negativo (1,1%), presentando tuttavia GGT 555 U/L, MCV 101 fl e livelli di EtG urinario, valutati 3 volte/settimana per 2 settimane, notevolmente aumentati (>50 mg/L). Da feb 2011, in carico al SerT, iniziava terapia con Disulfiram, ma continuava a bere, come testimoniato dalla famiglia e da ulteriore indagine con EtG urinario. A mag 2011, dopo ricovero d’urgenza (tasso alcolemico di 1,2 g/L), veniva trasferito presso struttura privata dove attualmente vive. Conclusioni: Questo caso evidenzia in modo significativo le criticità dell’uso di un marcatore a bassa sensibilità come la CDT nel monitoraggio di un paziente con storia di abuso alcolico cronico accertato. Inoltre, i dati suggeriscono una possibile interferenza di alcuni farmaci nel processo di formazione delle varie glicoforme di transferrina. 44° Congresso Nazionale SIBioC - Riassunti Poster P207 EBV: PROFILO SIEROLOGICO CON PRESENZA CONTEMPORANEA DI ANTI-EBNA IgG, ANTI-VCA IgG e ANTI-VCA IgM P208 EPIDEMIOLOGIA DELL’INFEZIONE DA TOXOPLASMA IN DONNE IN ETÀ FERTILE: DATI DEGLI ULTIMI 8 ANNI M. Della Strada, P. Billi, S. Pelliconi, S. Semprini L. Tomasicchio, A. Viniero, R. Genco, A.M. Rutigliano, V. Masellis, R. Luce, R. Scarcella, F. Di Serio U. O. Microbiologia-Centro Servizi Laboratorio Unico Area Vasta Romagna-Azienda USL Cesena Introduzione: I test sierologici per la diagnosi di infezione da Epstein-Barr Virus (EBV) comprendono tradizionalmente la ricerca di anti-EBNA IgG, anti-VCA IgG e anti-VCA IgM. La presenza contemporanea dei tre anticorpi può rappresentare un problema interpretativo. Materiali e metodi: In un anno (2011) di attività routinaria, si sono effettuati nel Laboratorio di Area Vasta Romagna 9294 test sierologici per EBV su analizzatore automatico in chemiluminescenza Liaison® (DiaSorin) impiegando reattivi Liaison® VCA IgG, Liaison® EBNA IgG e Liaison® EBV IgM. Risultati: La contemporanea presenza dei tre anticorpi è stata riscontrata su 261 campioni (corrispondenti a 220 pazienti) pari al 2,8% delle determinazioni. Dei 220 pazienti, 197 (89,5 %) sono stati testati per CMV (IgG e IgM); di questi 67 (34%) sono risultati CMV IgM positivi. Per altri 17 pazienti, nel corso degli accertamenti richiesti, sono emerse altre possibili cause di reattività crociata (Toxoplasma, Bartonella, Herpesvirus 1-2, Enterovirus, Adenovirus, Micoplasma), mentre per quattro pazienti è stato documentata la persistenza di IgM dopo infezione primaria (dati storici del Laboratorio). Conclusioni: Rimane un'elevata percentuale (60%) di casi in cui con i test richiesti di routine non è stato possibile una interpretazione del risultato (differenziazione tra: aspecificità, persistenza di IgM, o riattivazione). Per tali casi, su indicazione clinica, si ipotizza l'introduzione di blot per confermare la specificità delle IgM e l'esecuzione del test di avidità per distinguere tra persistenza di IgM dopo infezione primaria o riattivazione. U.O. Patologia Clinica I, Azienda Ospedaliero Universitaria Policlinico, Bari Introduzione: Quanto più precocemente nel periodo gestazionale viene contratta l’infezione da Toxoplasma gondii, tanto più gravi sono i danni fetali che essa procura. Grazie all’osservazione attenta dello stato di immunizzazione delle donne in età fertile e al miglioramento delle norme alimentari, negli ultimi anni si è avuta in Italia una riduzione di tali problematiche. Scopo del nostro studio è valutare tale evidenza fra le donne in età fertile sottoposte al test di screening, mediante dosaggio degli anticorpi anti-Toxoplasma IgG e IgM, afferenti alla nostra Unità Operativa nel periodo 2004-2012. Metodi: La ricerca di anticorpi anti-Toxoplasma (IgG e IgM) è stata effettuata in 8939 donne di età compresa tra i 13 e i 45 anni, suddivise in 3 classi di età, con metodo in chemiluminescenza (principio sandwich) a due step, su strumentazione Liaison (Dia Sorin). Con lo stesso metodo è stato effettuato il test di avidità delle IgG per individuare eventuali infezioni in atto. Risultati: La prevalenza di IgG anti-Toxoplasma nelle 8939 donne testate è stata del 14%, diminuendo dal 20% nel 2004 all’11% nel 2012. Considerando l’età, essa è stata del 10% per la classe di età 13-24 anni ed è aumentata progressivamente fino al 18% nella classe 35-45 anni. Si è osservata altresì una riduzione delle infezioni in atto dal 2% nel 2004 allo 0,7% nel 2012. Conclusioni: Una sieroprevalenza per Toxoplasma gondii del 14% costituisce un dato in linea con il generale trend di riduzione della sieropositività riscontrato in Italia e in altri Paesi (USA, U.K., Norvegia). Verosimilmente ciò è legato alla migliore sorveglianza alimentare rispetto ad altri Paesi come il Brasile dove la percentuale di immunizzazione si aggira intorno al 60%. L’aumento della prevalenza con l’età concorda con tali risultati. Masini L, Casarella L, Grillo RL, et al. Studio epidemiologico sulla prevalenza di anticorpi antiToxoplasma gondii in una popolazione ostetrica. It J Ginaecol Obstet 2008;20:159-66. Dubey JP. Toxoplasmosis: a waterborne zoonosis. Vet Parasitol 2004;126:57-72. biochimica clinica, 2012, vol. 36, n. 6 575 44° Congresso Nazionale SIBioC - Riassunti Poster P209 IL DOSAGGIO DEI MARKERS D'INFIAMMAZIONE E DEL NT-proBNP NEL FOLLOW-UP TERAPEUTICO CON PMX NELLA STRATIFICAZIONE DEL RISCHIO DEL PAZIENTE CON SEPSI SEVERA 1 1 2 1 A.M. Rosa , M. Sarno , A. Lepore , V. Plutino , R. 1 Antonetti 1 Dip. di Patologia clinica, II Lab. Analisi Azienda OspUniv. Foggia 2 Centro Antiveleni Introduzione: La diagnosi clinica di sepsi severa comporta, oltre ai segni clinici che caratterizzano la S.I.R.S. anche la presenza di disfunzione d'organo almeno in un sistema come quello cardiocircolatorio. Scopo del lavoro: Monitorare l'outcome del dosaggio dei markers di infiammazione quali PCR, procalcitonina (PCT), citochine e NT-proBNP nel follow-up terapeutico del paziente con sepsi severa. Materiali e metodi: Sono stati studiati 23 pazienti ricoverati nel reparto di Rianimazione con diagnosi di sepsi grave da Gram negativi (Endotossinemia > 0.6). Il dosaggio in chemiluminescenza di NT-proBNP è stato eseguito utilizzando il sistema Vitros 3600 della Ortho Clinical Diagnostics; i livelli delle citochine sono stati dosati all'inizio dello studio in chemiluminescenza con Immulite (Medical Systems); in seguito gli stessi pazienti sono stati analizzati con il sistema Evidence (tecnologia Biochip Array Randox) distribuito dalla Medical Systems e quelli della procalcitonina con tecnologia ELFA (Vidas Biomerieux). Risultati: Nei pazienti in trattamento con emoperfusione con cartuccia di PMX (Polimixina B) abbiamo osservato una correlazione positiva tra i valori dell'NT-proBNP con le citochine IL6, IL8 e MCP-1 (73%) e con la PCT (62.5%). Al tempo T0 i valori di NT-proBNP erano significativamente alti ed una costante riduzione si è avuta al T72 dopo terapia. I due sistemi Immulite e Evidence hanno presentato una buona correlazione tra i valori positivi e negativi dei campioni analizzati, anche se con diversi range di riferimento. Conclusioni: Nei pazienti con sepsi grave aumentano i livelli delle citochine, del NT-proBNP e della PCT e il trattamento con PMX determina una riduzione significativa delle loro concentrazioni sieriche. E' emerso un possibile utilizzo del NT-proBNP come marcatore di danno miocardico reversibile in caso di sepsi, non solo per i noti effetti cardiovascolari, ma anche immunomodulanti. 576 biochimica clinica, 2012, vol. 36, n. 6 P210 INNOVAZIONE TECNOLOGICA, SPENDING REVIEW E APPROPRIATEZZA DELLA RICHIESTA Z. Napoli, M. Donati, S. Turrisi, R. Lari, L. Bianchi U.O. Lab. di Analisi Chimico Cliniche e Microbiologiche, Ospedale del Ceppo, Pistoia Introduzione: Le nuove tecnologie quali microarray proteici, RT-PCR multiplex, automazione e informatica stanno trasformando progressivamente il modo di gestire la diagnostica microbiolgica. L’impiego di metodiche multistep amplia lo spettro diagnostico riducendo il turn around time (TAT) e permettendo un percorso diagnostico più efficace. Obiettivo: Scopo di questo studio è analizzare come inappropriatezza e inadeguatezza del campione possono ridurre il rapporto costo/benefico apportato dalle nuove metodologie incrementando la spesa sanitaria. Metodi: Con metodiche RT-PCR sono stati analizzati 189 campioni di LCR per la ricerca di batteri (EuSepscreen lattanti/adulti) e virus (BioMerieux) e 933 tamponi cervicali (TC) per ricerca di C.trachomatis (CT), N.gonorrhoeae (NG), ureaplasmi (UU e UP) e micoplasmi (MH e MG). Il cut-off di cellularità scelto è 1000cell/PCR (differenza di positività: p<0.001). Risultati: Per LCR il TAT complessivo è 2-3h. Si osserva il 12% di richieste inadeguate per il pannello batterico con esame chimico-fisico negativo e solo il 4% per le richieste virologiche: costo complessivo €3280 (12% della spesa complessiva). Per TC si osserva il 18% di inadeguati per cellularità scarsa, il 25% di casi con richiesta di 1 patogeno e il 12% su 2 o più matrici: costo complessivo di €32400 (45% della spesa complessiva). Conclusioni: I dati di questa analisi mostrano che diversi sono i fattori che possono far incrementare la spesa, valutata in questo studio solo per i reattivi, fino al 45%. La scelta della tecnologia (multiplex di più patogeni) può incidere del 24% sulla spesa con possibile diminuzione della qualità analitica, l’inadeguatezza per il 15% e l’inappropriatezza della richiesta, sottostimata in misura maggiore per le richieste ambulatoriali rispetto a quelle degli interni, per il 9%. Ne consegue che al microbiologo spetta il difficile onere di intervenire nell’integrazione migliore tra metodiche ormai consolidate e tecnologie emergenti (microarray e RT-PCR) e lo sforzo, oggi più che mai necessario vista la diminuzione delle risorse disponibili, per accrescere in prospettiva l’impatto clinico del referto molecolare, attraverso una maggiore appropriatezza e razionalizzazione delle richieste (che può produrre risultati negativi sul paziente) e una sempre maggiore efficacia della risposta. 44° Congresso Nazionale SIBioC - Riassunti Poster P211 INTRODUZIONE DEL TEST CMV AVIDITÀ A PIOMBINO: PRIME VALUTAZIONI P212 ACETYLCHOLINE RECEPTOR BINDING AUTOANTIBODIES IN PEMPHIGUS P. Brunori, L. Faggiani, L. Ceccarelli, L. Villani, P. Masi, C. Quintavalle, U. Paoletti, C. Centini, S. Del Chierico, A. Tognini, L. Biondi, V. Pappalardo G. Lobreglio, R. Torsello Analisi Chimico Cliniche (Aziendale) - Sezione Piombino, USL6 Livorno Generalità: L’infezione da Citomegalovirus (CMV) è frequente e spesso asintomatica, ma nel corso della gravidanza una infezione primaria può causare gravi danni al feto. La sola determinazione delle IgM antiCMV come screening nella gravidanza non permette di distinguere fra infezione primaria e riattivazione secondaria (meno pericolosa rilevata in circa il 20% dei casi). Nei campioni positivi per IgG e IgM, l‘avidità delle IgG è uno strumento per differenziare le infezioni primarie (bassa avidità) da quelle recidivanti o persistenti (alta avidità). L‘avidità, infatti, aumenta già nel primo mese dopo la sieroconversione per CMV e raggiunge un “plateau“ verso i 4-6 mesi successivi alla sieroconversione. Materiali e metodi: A giugno 2012 il test Architect (Abbott) CMVavidity è stato introdotto nel nostro laboratorio, in aggiunta protocollo precedente, che prevede la conferma della positività IgM con metodo alternativo (Vidas, Biomerieux). Il presente lavoro riassume la nostra esperienza allo scopo di affinare un protocollo diagnostico aziendale. Risultati: Su 1044 determinazioni di CMV IgG ed IgM, nel periodo considerato sono stati selezionati i 55 pazienti risultati positivi per IgM o comunque testati per CMVavidity. Il 53% dei casi ha fornito un risultato di avidità alta, il 41% bassa, ed il 6% in zona grigia (GZ). In 42 casi sono state determinate le IgM anche con il metodo alternativo che non ha sempre confermato la positività (il 29% dei casi è risultato negativo). Su 24 pazienti IgM+ sono stati eseguiti sia il test CMVavidity sia il dosaggio alternativo. Fra questi 7 hanno dato valori discordanti (Architect+ Vidas-), tutti con alta avidità, mentre 4 pazienti Architect+ sono risultati GZ con Vidas, 3 di questi sono risultati a bassa avidità. Con il metodo IgM Architect la percentuale di pazienti che risulta positiva è maggiore che con Vidas. Conclusioni: L’assunzione di un protocollo automatizzato permette di gestire agevolmente il maggior numero di casi risultati IgM+, anche negli stadi di sieroconversione durante l’ infezione primaria, che spesso risultano GZ con il metodo alternativo. U.O.C. Patologia Clinica, P.O. "Vito Fazzi", ASL LE, Lecce Background: The binding of autoantibodies to cell-surface antigens on keratinocytes results in blistering of the skin and oral cavity in a variety of dermatologic conditions. In pemphigus some autoantibodies with acantholytic activity bind to keratinocytes desmosomal cadherins, desmoglein (Dsg) 1 and Dsg 3. However pemphigus autoimmunity is not limited to antidesmoglein antibodies; non-desmoglein antibodies induce pemphigus-like lesion in neonatal mice and cholinergic receptors expressed by keratinocytes accumulate within regions of the cell membrane associated with the desmosomes. Therefore we sought to determine whether autoantibodies against the acetylcholine receptor (ARAb) are present in sera of patients with phemphigus. Methods: We studied 34 patients with pemphigus vulgaris ( 12 men and 22 women ), 11 patients with bullous pemphigoid; 8 patient with SLE, 13 patient with chronic urticaria, 7 patients with Duhring's dermatitis herpetiformis, and 21 normal subjects. The presence of circulating intercellular-substance antibodies was determined by indirect immunofluorescence on monkey esophagus; anti-desmoglein 1 and 3 antibodies were determined by an ELISA method; quantitative ARAb by a radioreceptor assay, which measure antibody binding to 125I-α-bungarotoxin-labeled acetylcholine receptor. Results and conclusions. ARAb were detected in 23 patients with pemphigus (67.6%) at variable titers, but not in sera of patients with other conditions or normal subjects: p<0.001. In 18 of the 23 patients with ARAb we detected also anti intercellular-substance antibodies directed against Dsg 1 or Dsg 3, but in 7 patients (17%) we found only the autoantibodies directed against the acethylcholine receptor. These results suggest that ARAb could lead to reversible detachment and acantholysis of keratinocytes in some patients with pemphigus. Further work will be needed to determine the target epitope of the ARAb on the keratinocytes and how these antibodies contribute to the pathogenesis of pemphigus. biochimica clinica, 2012, vol. 36, n. 6 577 44° Congresso Nazionale SIBioC - Riassunti Poster P213 ANTICORPI ANTI-GLICOPROTEINA 2 (GP2): UN NUOVO MARCATORE ASSOCIATO A FENOTIPI DELLA MALATTIA DI CHRON 1 1 1 1 L. Marinelli , G. Ciarrocchi , B. Cinti , V. Viola , M. 1 2 2 2 d'Anzeo , E. Bendia , G. Falcioni , A. Benedetti , S. 3 3 3 Gatti , V. Romagnoli , C. Catassi P214 DETERMINAZIONE DEI LIVELLI CIRCOLANTI DI FARMACO E DELLA PRESENZA DI ANTICORPI ANTI-FARMACO IN PAZIENTI CON PATOLOGIE INFIAMMATORIE CRONICHE AUTOIMMUNI IN TERAPIA CON INFLIXIMAB 1 1 1 1 C. Guiotto , L. Germano , M. Vizzini , E. Miotto , M. 2 3 2 1 Daperno , R. Pellerito , R. Rocca , M. Migliardi 1 SO Laboratorio Analisi, Sierologia, Ospedali Riuniti Policlinico – Ancona 2 SO Clinica di Gastroenterologia, Università Politecnica delle Marche - Ancona 3 SO Clinica di Pediatria, Università Politecnica delle Marche - Ancona Introduzione: Studi recenti hanno dimostrato che una glicoproteina di membrana (GP2) presente nei granuli di zimogeno costituisce il target di autoanticorpi antipancreas, associati alla Malattia di Crohn (MC). Lo studio intende dimostrare l’associazione di anticorpi anti-GP2 con alcuni fenotipi della malattia. Materiali e metodi: Un totale di 83 sieri di pazienti adulti e pediatrici, 51 con diagnosi di MC e 32 con Retto-Colite Ulcerosa (RCU), sono stati esaminati per la ricerca di anticorpi anti-GP2 e anticorpi anti-ASCA mediante test elisa (GA-Generic Assays; Alifax). Un gruppo di controllo di 25 donatori sani (DS) è stato esaminato in parallelo. Il test anti-GP2 impiega un antigene di GP2 umana ricombinante. Il valore di 20 U/mL è stato considerato quale cut-off per entrambi i test. Risultati: 15 sieri (29,4%) risultarono positivi per IgG e/ o IgA anti-GP2 nel gruppo di pazienti MC; 4 pazienti (12,5%) erano positivi nel gruppo RCU. Nessun donatore sano risultò GP2 positivo. Presenza di anticorpi antiASCA è stata riscontrata in 24 (47%) pazienti MC, ma in nessun siero RCU e DS, rispettivamente. Dei 15 sieri GP2 positivi, 9 erano GP2 e ASCA positivi, 6 erano ASCA negativi. Dei 24 casi ASCA positivi, 15 risultarono GP2 negativi. Sommando la positività di anti-GP2 e antiASCA, la sensibilità complessiva nel gruppo MC salì al 58,8% (30 casi). Nessuna variazione è stata osservata nei gruppi RCU e DS. Riguardo all’associazione di anti-GP2 con fenotipi di MC, 11/15 pazienti GP2 positivi avevano una localizzazione ileo-colica, 10/11 mostravano gradi di attività endoscopica (SES) da moderata a severa, in 9/15 è stato evidenziato un fenotipo stenosante. Quest’ultimo aspetto è risultato statisticamente significativo con il riscontro di anticorpi anti-GP2 (p=0.002). Conclusioni: Il nuovo test sierologico anti-GP2 appare in via preliminare un marcatore specifico e selettivo di MC, significativamente associato con una localizzazione ileo-colica della malattia. Dettagli clinici e di laboratorio saranno discussi. Roggenbuck D, Hausdorf G, Martinez-Gamboa L, et al. Identification of GP2, the major zymogen granule membrane glycoprotein, as the autoantigen of pancreatic antibodies in Chron's disease. Gut 2009;58:1620-8. 578 biochimica clinica, 2012, vol. 36, n. 6 1 Lab. Analisi, Osp. Ordine Mauriziano, Torino Gastroenterologia, Osp. Ordine Mauriziano, Torino 3 Reumatologia, Osp. Ordine Mauriziano, Torino 2 Obiettivi: Scopo di questo studio pilota è il confronto di due metodi per la determinazione dei livelli circolanti di Infliximab (IFX) e degli anticorpi anti-Infliximab (ATI) e la valutazione della relazione tra i diversi profili clinici e la presenza in circolo del farmaco e/o degli anticorpi antifarmaco in soggetti con patologie infiammatorie croniche autoimmuni, gastroenteriche o reumatiche, in terapia con Infliximab, farmaco biologico diretto contro il TNFα. Metodi: Sono stati arruolati 25 pazienti con patologie gastroenteriche (n=13) e reumatiche(n=12): 23 in terapia con IFX e 2 con Adalimumab (altro biofarmaco) precedentemente trattati con IFX. I campioni di siero sono stati prelevati prima dell’infusione del farmaco. Sono stati valutati due tipi di metodi: Promonitor IFX Determination of Drug and Anti-drug Antibodies Concentration (Menarini) e TNFα Blocker monitoring/Antibodies against TNFα Blocker (ImmunDiagnostik). Risultati: I due metodi per la misura del farmaco sono ben correlati (R di Spearman 0.821, p <0.0001), ma la concordanza tra i risultati ottenuti è scarsa (y=2.55x +0.713). Nei due pazienti in terapia con Adalimumab, l’IFX risulta indosabile con il metodo Promonitor (<0.053 mg/ mL), mentre con il metodo ImmunDiagnostik si ottengono valori pari a 6.5 e 20.1 μg/mL, probabilmente dovuti a reazione crociata tra i due farmaci. Con entrambi i metodi è stata osservata la presenza di ATI in due pazienti, condizione che correla con la perdita clinica della risposta al trattamento. Conclusioni: I risultati ottenuti con i due metodi correlano con il quadro clinico e presentano una buona correlazione tra loro. La misura combinata di IFX e ATI si rivela un utile supporto per monitorare e ottimizzare la terapia con Infliximab. La valutazione di casistiche più ampie e omogenee sarà necessaria per confermare i risultati ottenuti. Lo studio è stato realizzato grazie al contributo della Fondazione Scientifica Mauriziana Onlus. Chaparro M, Guerra I, Munoz-Linares P, et al. Systematic review: antibodies and anti-TNFα levels in inflammatory bowel disease. Aliment Pharmacol Ther 2012;35:971-86. 44° Congresso Nazionale SIBioC - Riassunti Poster P216 TIPIZZAZIONE HLA NELLA DIAGNOSI DEL MORBO CELIACO: ESPERIENZA SU POPOLAZIONE PEDIATRICA DEL TORINESE P215 MARCATORI IMMUNOLOGICI DI ARTRITE REUMATOIDE: DALLE LINEE GUIDA ALL’APPLICAZIONE PRATICA 1 1 2 1 2 2 2 C. Alpini , S. Valaperta , F. Bobbio-Pallavicini , G.B. 1 1 Vadacca , G. Merlini T. Manetta , M.F. Rostagno , M. Pozzato , I. Dagna , A. 2 3 Cristiano , C. Barbera 1 1 Servizio Analisi Chimico Cliniche, Fondazione I.R.C.C.S. Policlinico S.Matteo, Pavia 2 Unità di Reumatologia, Fondazione I.R.C.C.S. Policlinico S.Matteo, Pavia Scopo: L’algoritmo proposto da Jaskowski et al. per la diagnosi dell’artrite reumatoide (AR) si basa sulla determinazione degli isotipi del fattore reumatoide (RF) e degli anticorpi anti peptide ciclico citrullinato (CCP). Nel presente lavoro abbiamo valutato l’impatto di due saggi ELISA per la determinazione degli isotipi del RF sulla classificazione di 100 pazienti con diagnosi clinica di AR. Materiali e metodi: 1) 100 sieri di pazienti con diagnosi di Early AR (F 69, 46aa±18, M 31, 52aa±11); 2) RF IgA-IgG-IgM ELISA, Orgentec, strumentazione DSX; 3) RF IgA-IgM-IgG EliA e CCP 2 IgG EliA, Phadia ab, strumentazione ImmunoCap250. Risultati: Stratificando i pazienti in base all’algoritmo proposto abbiamo ottenuto i seguenti risultati: Classe 1 “diagnosi quasi certa”: 6% di pz con RF EliA vs 11% con RF ELISA; Classe 2 “diagnosi molto probabile”: 3% di pz con entrambi i saggi; Classe 3 “diagnosi probabile”: 3% di pz con RF EliA vs 6% con RF ELISA; Classe 4 “diagnosi possibile”: 84 % pz con RF EliA vs 69% con RF ELISA. Discussione e conclusioni: Questa esperienza di lavoro ha dimostrato che il dosaggio di test immunologici di laboratorio, per altro inclusi nei criteri dell’American College of Rheumatology per la diagnosi di artrite reumatoide, e la loro applicazione nell’algoritmo di Jaskowski, sono un valido supporto per la conferma di una diagnosi, ma insufficienti come profilo diagnostico per AR. Questo conferma che nonostante i progressi del laboratorio, la diagnosi di questa patologia è ancora essenzialmente clinica, soprattutto in fase precoce di malattia. Jaskowski TD, Hill HR, Russo KL, et al. Relationship between rheumatoid factor isotypes and IgG anticyclic citrullinated peptide antibodies. J Rheumatol 2010;37:1582-8. Laboratorio Citoimmunodiagnostica, Dipartimento Scienze della Sanità Pubblica e Pediatriche AO OIRMS.Anna, Torino 2 Dipartimento Diagnostica e Servizi AO OIRM-S.Anna, Torino 3 Servizio di Gastroenterologia, Dipartimento Scienze della Sanità Pubblica e Pediatriche AO OIRM-S.Anna, Torino La celiachia è conseguenza di una alterata risposta al glutine in soggetti con determinate varianti geniche degli alleli HLA, ovvero il DQ2 (osservato nel 90-95% dei celiaci) ed il DQ8 (presente in circa il 5% dei pazienti). Esiste una quota di pazienti celiaci (meno del 2%) che non possiede né il DQ2 né il DQ8, così come circa il 30% della popolazione generale (non celiaca) presenta i suddetti alleli predisponenti. Nel nostro studio sono stati esaminati 514 pazienti (età 2-16 anni, periodo Gennaio 2009-Dicembre 2011) con diagnosi di sospetta celiachia; ciascuno è stato sottoposto al dosaggio degli anticorpi anti-endomisio (IFA test, celiac Monkey Distal Esophagus EMA kit- Diamedix), anti transglutaminasi (Elia autoimmunity Thermofisher- Celikey IgA-Acy) e ad una tipizzazione HLA con tecniche di biologia molecolare (SSO INNO-LIPA). Scopo del lavoro è stato quello di verificare, laddove si accertasse una diagnosi di celiachia, con positività degli anticorpi anti-endomisio ed anti-transglutaminasi, quale fosse il fenotipo HLA correlato, per documentare se la presenza di un HLA DQ2 e/o DQ8 rappresenti una condizione predisponente alll’insorgere della patologia nella nostra popolazione. Obiettivo secondario è stato accertare quali fossero gli altri HLA DQ presentati dai pazienti celiaci DQ2 e/o DQ8 negativi ed i DQ dei pazienti “sierologicamente” negativi. Dei 514 pazienti esaminati, 417 sono risultati negativi e 97 positivi; nei negativi, 178 presentavano un eterodimero HLA predisponente; nei positivi, 16 possedevano un eterodimero HLA non predisponente. Il contributo della genetica potrebbe "modificare" l'approccio diagnostico per il morbo celiaco, ma non va dimenticato che il contributo della biopsia intestinale è ancora molto importante per la definizione stessa della malattia. Fino a quando i metodi sierologici non saranno ulteriormente migliorati e la costituzione genetica dei celiaci meglio definita sembra prudente, per la diagnosi di celiachia, affidarsi ad un approccio combinato di criteri clinici, genetici, sierologici ed istologici. Husby S, Koletzko S, Korponay-Szabó IR, et al. European Society for Pediatric Gastroenterology, Hepatology, and Nutrition guidelines for the diagnosis of coeliac disease. J Pediatr Gastroenterol Nutr 2012;54:136-60. biochimica clinica, 2012, vol. 36, n. 6 579 44° Congresso Nazionale SIBioC - Riassunti Poster P217 TUMOR NECROSIS FACTOR ALPHA (TNF) PROMOTER HAPLOTYPE CONCURS WITH HLADQA1-DQB1 IN DETERMINING CELIAC DISEASE RISK P218 VALUTAZIONE DEL DOSAGGIO DI ANTICORPI ANTI-RECETTORE TSH CON METODO DI TERZA GENERAZIONE 1 1 1 1 1 E. Rossi , C. Zambon , F. Navaglia , E. Greco , D. 1 1 1 1 1 Bozzato , M. Pelloso , A. Aita , P. Fogar , S. Moz , G. 2 1 1 Guariso , D. Basso , M. Plebani 1 Dipartimento di Medicina di Laboratorio, Azienda Ospedaliera Università di Padova, Padova 2 Dipartimento di Pediatria, Azienda Ospedaliera Università di Padova, Padova The rare A alleles at -308 and -238 positions of the TNFa gene have been associated with CD. Although they may be candidate disease susceptibility factors, it is likely that they act as part of TNFa haplotypes resulting from the combination of more SNPs of the promoter. The scopes of this study were to ascertain whether five SNPs in the TNFa promoter (-1031T>C,-857C>T,-376G>A,-308G>A,-238G>A) are associated singly or as haplotypes with CD and whether their effect is HLA-DQA1/–DQB1 dependent or independent. 527 children (250 CD, 277 controls) were studied. TNFa gene polymorphisms and HLADQA1 and –DQB1 alleles were analysed by RTPCR. The TNFa-1031C (OR=2.540,95%CI:1.157-5.575), -857T (OR=0.421,95%CI:0.282-0.627), -376A (OR=2.037,95%CI:1.109-3.741) and -308A (OR=4.486,95%CI:3.076-6.541), but not -238 alleles, were significantly CD-associated, this finding being confirmed at multivariate logistic regression analysis. The possible haplotypes derived from the combination of these four SNPs were estimated using the Arlequin statistical software. Six haplotypes were obtained: two (CCGG,TTGG) were more frequent in controls; three (CCAG,TCGA,CCGA) were more frequent in CD; one (TCGG) was equally found in controls and CD. TNFa promoter genotypes inferred from haplotypes were classified in six categories: 1)CD-associated/CD-associated; 2)CDassociated/TCGG; 3)CD-associated/control-associated; 4)control-associated/TCGG; 5)TCGG/TTG; 6)controlassociated/control-associated. A strong correlation was found between the first two categories and CD and between the last category and controls not only considering all cases, but also considering only those bearing HLA-DQA1/–DQB1 risk alleles. Binary logistic regression analysis performed by including among predictors TNFa promoter genotypes and HLA-DQ haplotype, documented a strong association between CD and homozygous HLA-DQ2 (OR=481;95%CI:112-2068), heterozygous HLA-DQ2 (OR=73;95%CI:26-208) or HLA-DQ8 (OR=14;95%CI:5-45), but also an HLAindependent correlation with CD-associated TNFa promoter homozygous (OR=7;95%CI:1,48-34,31) or heterozygous (OR=5;95%CI:1,56-16,59) genotypes. In conclusion the TNFa promoter haplotypes CCAG, TCGA and CCGA was shown to increase CD risk independently from HLA-DQ alleles suggesting the pivotal role of TNFa in the disease pathogenesis. 580 biochimica clinica, 2012, vol. 36, n. 6 2 1 1 M. Brugia , S. Suppressa , F. Balducci , R. Ferroni , M. 1 Tocchini 1 Lab. Biochimica Clinica e Microbiologia. Azienda Ospedali Riuniti Ancona 2 Patologia Clinica Università di Bologna Premesse: Gli anticorpi anti-recettore del TSH (TrAb) stimolano la ghiandola tiroidea a produrre una maggiore quantità di ormoni in quanto stimolano il recettore del TSH. Il loro dosaggio è utile per diagnosticare il morbo di Graves-Basedow, per monitorare le donne in gravidanza e il rischio di recidive. Nella prassi clinica, la rilevazione dei TrAb avviene tramite dosaggi di seconda generazione che utilizzano TSHr umano o suino immobilizzato con anticorpi (RIA, ELISA). Un anticorpo monoclonale stimolante la tiroide umana (M22) ha reso possibile la messa a punto di un nuovo dosaggio dei TrAb automatizzato. Materiali e metodi: Tra luglio e agosto 2012 sono stati esaminati 76 campioni di siero afferenti al laboratorio dai reparti interni e dagli Ospedali della regione Marche. Il dosaggio dei TrAb è stato effettuato sia mediante metodo RIA (Stratec SR300 Brahms; sensibilità 0,3 IU/L, cutoff 1,5 IU/L TSHr umano) che elettrochemiluminescente (Modular E170 Roche; sensibilità 0,3 IU/L, cut- off 1,75 IU/ L). L’analisi statistica è stata eseguita con SPSS. Risultati: Il dosaggio dei TrAb, eseguito con entrambe le metodiche, è risultato essere al di sotto dei rispettivi cutoff in 60 campioni; in 14 campioni, invece, ha presentato valori positivi al test. Solo 2 campioni positivi al test RIA (1.6-2 UI/L) sono risultati invece negativi con metodo ECLIA (0,30-1,33 UI/L). La curva di regressione lineare ha mostrato un buona correlazione tra i 2 metodi (R 0,88). Conclusioni: Nonostante la differenza dei metodi utilizzati in quanto utilizzano anticorpi e tecniche di rilevazione diverse, la correlazione è comunque risultata buona. I soli 2 casi con discrepanza avevano concentrazioni di TrAb molto basse vicine al cut-off RIA. L’utilizzo in routine di un metodo automatizzato di terza generazione potrebbe apportare un miglioramento sia in termini di rapidità di refertazione che riduzione del rischio radioattivo. Kamijo K, Ishikawa K, Tanaka M. Clinical evaluation of 3rd generation assay for thyrotropin receptor antibodies: the M22-biotin-based ELISA initiated by Smith. Endocr J 2005;52:525-9. Sanders J, Jeffreys J, Depraetere H, et al. Characteristics of a human monoclonal autoantibody to the thyrotropin receptor: sequence, structure and function. Thyroid 2004;14:560–70. 44° Congresso Nazionale SIBioC - Riassunti Poster P221 CORRELATION BETWEEN LIPID PROFILE AND INTIMA MEDIA THICKNESS AT DELIVERY IN PREGNANCIES COMPLICATED BY INTRAUTERINE GROWTH RESTRICTION 1 1 1 2 P222 DETERMINAZIONE DEI LIVELLI DI PRESEPSINA (SCD14-ST) SU SANGUE CORDONALE DI NEONATI SANI MEDIANTE PATHFAST™ PRESEPSIN (MITSUBISHI CHEMICAL) 1 2 1 1 C. Cosma , D. Faggian , M. Zaninotto , S. Visentin , E. 2 3 1 Cosmi , A. Lapolla , M. Plebani S. Sale , A. Casani , M. Fumi , Y. Pancione , L. 2 1 Orfeo , V. Rocco 1 1 Dep. of Laboratory Medicine, University-Hospital, Padova, Italy 2 Dep. of Health of the Woman and Child, University of Padua, Padova, Italy 3 Dep. of Medical and Surgical Sciences, University of Padua, Padova, Italy Background: Low birth weight is known to be associated with an increased in cardiovascular risk. Aim: This study has examined the associations between abdominal aortic fetal intima media thickness (aIMT) measured in utero during the early third trimester of pregnancy and neonatal and maternal lipid profile at delivery in pregnancies complicated by intrauterine growth restriction. Materials and methods: 165 patients were enrolled and divided in control (AGA=97), small for gestational age with (SGA=57) and intrauterine growth restriction (IUGR=11). The aIMT was determinated by ultrasonography in the early third trimester of pregnancy. The lipid profile was measured in mothers and fetuses at delivery. Data were expressed in median, considering significant p<0.05. Results: The groups are similar for pre-pregnancy BMI and age. IUGR groups presented a lower birthweight than the other two (1919 gr vs 2567 gr vs 3254 gr, respectively, p< 0.05). aIMT was significantly higher in IUGR than SGA and AGA (1,05 mm vs 0.77 mm vs 0.59 mm respectively, p<0.05). Total cholesterol, HDL, LDL, oxidized LDL, and triglycerides maternal were significant higher compared to neonatal. The fetal concentration of leptin is lower than maternal but this difference is only significantly in IUGR (p=0.0343). Fetal leptin was positively correlated with birthweight (p<0.05). The fetal concentration of oxidized LDL was significantly higher in IUGR than SGA and AGA (18 mmol/L vs 12.59 mmol/L and 13.51 mmol/L, respectively, p<0.05). Higher fetal cholesterol and LDL were significantly associated with lower neonatal weight (p<0.05). There was a hypertrigliceridemia in SGA and IUGR groups than AGA (p= 0.05) and among SGA fetuses we found a significant positive correlation between fetal aIMT and trygliceride concentration (p<0.05). Finally we found a negative correlation between oxidized LDL and aIMT that among IUGR and SGA was not significantly positive. Conclusion: Lipidic profile of the mother is correlated with lipidic profile of the fetus and newborns with low birthweight had higher chances to present higher colesterol and LDL. Low birthweight was associated with dislipidemic state as well as high tryglicerids were associated with increase aIMT in intrauterine growth restricted fetuses. 582 biochimica clinica, 2012, vol. 36, n. 6 U.O.C Patologia Clinica, A.O.R.N. "G. Rummo" di Benevento 2 TIN, A.O.R.N. "G. Rummo" di Benevento La sepsi è una delle principali cause di morbidità e mortalità nelle TIN. La necessità di una diagnosi precoce, che non può attendere l’esito delle colture, ha reso necessario lo sviluppo di test sierologici rapidi come ausilio diagnostico. La presepsina, ovvero la frazione solubile del CD14 (sCD14), è risultata significativamente più elevata in adulti con sepsi. Pochi studi hanno dimostrato il valore diagnostico anche nei neonati. Scopo del lavoro è stato valutare i livelli plasmatici di sCD14 su sangue cordonale in neonati a termine sani, mediante PATHFAST™ Presepsin (Mitsubishi Chemical). Metodologia: Il PATHFAST™ Presepsin con metodica immunoenzimatica in chemiluminescenza può effettuare determinazioni su piccole quantità di sangue intero in pochi minuti. I campioni sono stati ottenuti in sala parto attraverso puntura del cordone subito dopo clampaggio. Dopo separazione, il plasma, refrigerato a T=2-8 °C, è stato analizzato entro 3 giorni. Risultati: Il valore medio di sCD14 cordonale è risultato 953 pg/mL (±419) (95% ICmedia: 848-1058 pg/mL) con un range tra 290 e 1943 (2.5°-97.5°centile). I valori riscontrati risultano più elevati rispetto a quelli ottenuti con la medesima metodica in una popolazione di adulti sani. Per cui, in riferimento ad altri studi circa la scarsa capacità dei neonati di produrre sCD14, in condizioni normali, è probabile che la discordanza sia dovuta all’utilizzo di metodiche differenti. Nonostante la significatività del valore medio, l’ampio range di valori di sCD14, ci ha indotto a tentare una correlazione con altri indici di flogosi/infezione: conta # e % dei monociti, ratio I/T dei neutrofili, analisi citofluorimetrica dei monociti (CD14,CD64,CD16,CD45). Conclusioni: I risultati ottenuti dimostrano che un valore di sCD14 pari al 95% IC mediana (967 pg/mL) è correlato, sia alla conta monocitaria fornita dall’emocitometro (Siemens ADVIA 2120i) (p=0.0004), sia alla conta % ottenuta mediante analisi citofluorimetrica (p<0.0001), che al valore I/T dei granulociti neutrofili (p=0.0008). Ad ogni modo, sono necessari ulteriori studi, sia sui neonati a termine sani, che su quelli settici, per la validazione clinica di questo test. 44° Congresso Nazionale SIBioC - Riassunti Poster P223 DIAGNOSTIC ACCURACY OF sFlt-1, PlGF, sFlt-1/ PlGF RATIO AND PTX3 IN PREECLAMPSIA 1 2 2 F. Cappellini , P. Algeri , S. Ornaghi , D. 3 1 4 5 Bernasconi , S. Signorini , P. Brambilla , G. Urban , P. 2 Vergani 1 University Dept. of Laboratory Medicine, Hospital of Desio, Desio, Monza e Brianza, Italy 2 Dept. of Obstetric and Gynaecology, Univ. of MilanBicocca, Monza, Monza e Brianza, Italy 3 Clinical Medicine and Prevention, Center of Biostatistic for Clinical Epidemiology, Univ. of Milan-Bicocca, Monza, Monza e Brianza, Italy 4 Dept. of Experimental Medicine, School of Medicine, Univ. of Milan-Bicocca, Monza, Monza e Brianza, Italy 5 Dept. of Obstetric and Gynaecology, Hospital of Desio, Desio, Monza e Brianza, Italy Introduction: Preeclampsia (PE) is a common, pregnancyspecific syndrome defined by elevated blood pressure combined with proteinuria and edema. The incidence has been reported in 2±7% of all pregnancies. Abnormal levels of endothelial dysfunction markers, such as soluble Fmslike tyrosine kinase 1 (sFlt-1), Placental Growth Factor (PlGF), and of systemic inflammation marker, such as Pentraxin 3 (PTX3), have been observed in maternal blood during the disease. Aim of the study was to define the diagnostic sensitivity (sens) and specificity (spec) of sFlt-1, PlGF, sFlt-1/PlGF ratio and PTX3 in PE. Materials and methods: Twenty-two singleton preeclamptic patients (cases) and 23 controls, represented by gestational age homogeneous women compared to cases, were included in the study; controls were represented by singleton pregnancies complicated by preterm delivery, intrauterine growth restriction and preterm premature rupture of membranes. Maternal serum samples were collected at delivery in Obstetric and Gynaecology department of San Gerardo Hospital, Monza between January 2005 and December 2007. Samples analysis were performed in May 2012 at laboratory of Desio Hospital, Desio. sFlt-1 and PlGF were measured on Cobas 8000 by electrochemiluminescence assay (Roche Diagnostics), PTX3 was measured on BEP 2000 Advance (Siemens Healthcare Diagnostics) using an ELISA assay (Diesse Diagnostica Senese). ROC curves for each marker was performed. Results: sFlt-1 had an AUC of 0,927; the optimal cut-off was 5579 pg/mL with a sens of 95,5% and a spec of 78,3%. PlGF showed a lower value of AUC (0,82), a cutoff equal to 48,9 pg/mL, with sens of 87,0% and spec of 77,3%. sFlt-1/PlGF ratio showed the best performance with an AUC value of 0,949. The cut-off was 132,3 with a sens of 90,9% and a spec of 91,3%. PTX3 had the lowest AUC value (0,772) with a cut-off of 2,1 ng/mL (sens = 86,4%; spec = 69,6%). Conclusion: Our results suggested sFlt-1/PlGF ratio as the most accurate marker for identification of PE at delivery. Collecting samples of new preeclamptic patients at different gestational ages could be useful in order to establish the sFlt-1 and PlGF rising times. P224 EVALUATION OF ANTI-MÜLLERIAN HORMONE IN YOUNG GIRLS WITH TURNER'S SYNDROME 1 2 2 1 G.L. Salvagno , R. Gaudino , C. Piona , M. Gelati , P. 2 2 1 Cavarzere , F. Antoniazzi , G.C. Guidi 1 Sezione di Biochimica Clinica, Dipartimento di Scienza della Vita e della Riproduzione, Università di Verona 2 Sezione di Pediatria, Dipartimento di Scienza della Vita e della Riproduzione, Università di Verona Background: Turner syndrome (TS) is a chromosomal anomaly characterized by the complete or partial deletion of the second sex chromosome responsible for a heterogeneous constellation of clinics events of which the most important are the short stature, ovarian dysgenesis and infertility. Recently, anti-Mullerian hormone (AMH) has been suggested as an indirect marker of ovarian reserve in women with hypogonadism and infertility. Aim: The aim of our study was to determine AMH serum concentration, the genotypic characteristics, phenotype and health status of patients with TS in different stages of life. Materials and methods: We evaluated AMH concentration in 23 patients with Turner’s syndrome follow at the Centre for Paediatric Endocrinology. AMH concentration was determined using AMH Gen II Elisa (Beckman Coulter), assessed on a Triturus® EIA Analyzer (Grifols). The genotypic characteristics, phenotype and health status of patients was evaluated during the routine pediatric visit. Results: First of all, this study showed the extreme phenotypic heterogeneity and genotypic of this syndrome, highlighted especially by the variability of response to treatment with growth hormone. The second important result was that AMH was not detectable in 91.3% (21/23) of patients with TS that differs statistically significantly from AMH’s levels in healthy volunteers. Finally, 33.3% of our patients were positive for searching of Y-chromosome material, an important risk factor for the development of gonadal tumors. Conclusions: From the analysis of auxological parameters evaluated in our patients who have reached the final height , emerges the need to perform new studies in order to identify clinical, laboratory or genetic factors able to better predict the response to therapy for short stature. A systematic search for a hidden Y-chromosome mosaicism, and AMH levels in TS patients could help us to evaluate the risk of development of germ cell tumors and ovarian preservation improving the quality of life of these patients. biochimica clinica, 2012, vol. 36, n. 6 583 44° Congresso Nazionale SIBioC - Riassunti Poster P225 INFLAMMATORY MARKERS, INTRAUTERINE GROWTH RESTRICTION AND AORTA INTIMA MEDIA THICKNESS AT DELIVERY 1 1 1 2 C. Cosma , D. Faggian , M. Zaninotto , S. Visentin , E. 2 3 1 Cosmi , A. Lapolla , M. Plebani 1 Dep. of Laboratory Medicine, University-Hospital, Padova, Italy 2 Dep. of Health of the Woman and Child, University of Padua, Padova, Italy 3 Dep. of Medical and Surgical Sciences, University of Padua, Padova, Italy Background: Intrauterine growth restriction (IUGR) and neonatal low birth weight are often associated with increased intima/media thickness of the abdominal aortic wall (aIMT). Studies performed on the abdominal aortic wall of a stillbirth presenting with IUGR and aIMT have suggested an association among IUGR, aIMT, and inflammation. This studies led us to analyzed a profile inflammatory (IL6, TNF-alfa and protein C reactive). Aim: This study has compared maternal and fetal inflammatory markers at delivery in pregnancies complicated by intrauterine growth restriction and examine the association with aIMT. Materials and methods: 165 patients were enrolled and divided in control (AGA, n=97), small for gestational age (SGA, n=57) and intrauterine growth restriction (IUGR, n=11). We measured aIMT by ultrasonography in the early third trimester of pregnancy. Inflammatory profile (PRC, IL-6 and TNF-alfa) was evaluated in mothers and fetuses at delivery. Exclusion factors were diagnosis of maternal chorioamnionitis or maternal diseases that may support an ongoing inflammatory state. Data was analyzed by Analyse.it and expressed in median considering significant p<0.05. Results: There were not differences in maternal age, parity and pre-pregnancies BMI among the groups. The 97 AGA delivered at a mean gestational age of 38.27 weeks (±2.21) significantly higher than IUGR fetuses (35.18 weeks ±2.44) (p<0.05) but not than SGA (38.23 weeks±1.61) (p=0.6). aIMT was significantly higher in IUGR than SGA and AGA (1,05 mm vs 0.77 mm vs 0.59 mm respectively, p<0.05). TNF-alfa and PCR were not significantly different in cases compared to AGA for both mothers and fetuses. Moreover, we not found differences among the groups as regards IL-6 and no significant correlation was observed between aIMT and fetal or maternal inflammatory status. Conclusion: Our data do not confirm previous reports where higher inflammatory markers were found in fetuses with intrauterine growth restriction. Considering our results inflammatory markers could not be linked to signs of possible vascular damage in SGA and IUGR fetuses as well as it could be connected to a particular maternal or fetal metabolic status. 584 biochimica clinica, 2012, vol. 36, n. 6 P226 LA BIOCHIMICA URINARIA DEL FETO OTTENUTA CON CISTOCENTESI: UTILITA' CLINICA NELLE GRAVI UROPATIE FETALI 1 2 2 2 C. Rossi , M. Pellegrino , G. Noia , L. Masini , C. 2 2 2 2 Manzoni , A. Giona , A. Facente , A. Caruso , C. 1 1 Zuppi , C. Callà 1 Dipartimento di Diagnostica e Medicina di laboratorioPoliclinico universitario "A.Gemelli", Roma 2 Dipartimento per la tutela della salute della donna e della vita nascente-Policlinico universitario "A.Gemelli", Roma Introduzione: La gestione delle uropatie ostruttive in fase prenatale non può prescindere dalla diagnostica invasiva e non. L’approccio diagnostico invasivo più frequente è la cistocentesi ecoguidata, con prelievo di urina fetale nel punto di transfissione. La biochimica urinaria fetale è determinante nella scelta dell’approccio invasivo più appropriato.Scopo del lavoro è stato dimostrare che cistocentesi ripetute (2 casi) possono essere diagnostiche e terapeutiche, determinando miglioramenti pressori nel detrusore vescicale fetale, contribuendo al buon esito perinatale. Materiali e metodi: Prima paziente: 26a settimana con diagnosi di massa fetale addominale sin (sospetto rene displasico multicistico). Seconda paziente: 14a settimana con diagnosi di megavescica fetale. In entrambe sono state effettuate 7 cistocentesi ecoguidate. Sui campioni di urina fetale sono stati dosati: elettroliti, creatinina, microalbuminuria ed osmolalità (C 311 Roche, BNII Siemens, Osmometro AI). Risultati: I parametri di funzionalità renale, nel primo caso, sono risultati sempre elevati indice di una funzionalità compromessa. A 4 giorni di vita, il bambino è stato sottoposto a nefroureterectomia sn, con diagnosi definitiva di forma segmentale di displasia renale. La cistouretrografia effettuata a 3 mesi di vita ha evidenziato: parenchima renale dx sano, con funzionalità renale nella norma. Nel secondo caso i test biochimici sull’urina fetale hanno evidenziato una normale funzionalità del parenchima renale pur in presenza di megavescica (sindrome di Prune-Belly), confermata postnatalmente. Alla nascita le condizioni generali sono risultate discrete con parametri biochimici e ecografia dell’apparato urinario nella norma. Conclusioni: L’uso delle tecniche invasive ecoguidate ha permesso di considerare il feto come "paziente" e l’approccio invasivo può essere effettuato con un rapporto rischio-beneficio basso.Le indagini biochimiche nei distretti indagati hanno permesso di monitorare l’evoluzione della patologia, conducendo le gravidanze fino alla 37°e 38° settimana, rispettivamente, con un intervento appropriato e senza accanimento terapeutico. I test biochimici sono stati di grande supporto per la formulazione della diagnosi confermata alla nascita dei bambini e per detendere la distensione della megavescica fetale. 44° Congresso Nazionale SIBioC - Riassunti Poster P229 PROTEOMICS IDENTIFIES PLACENTAL PROTEINS ALTERED BY GESTATIONAL DIABETES MELLITUS 1 2 3 3 A. Lapolla , G. Desoye , G.B. Nardelli , G. Bogana , M. 3 1 4 Carrozzini , M. Roverso , P. Traldi 1 Dep. of Medical and Surgical Science, University of Padova 2 Dep. of Obstetrics and Gynecology, Medical University of Graz, Austria 3 Dep. of Gynecological Sciences and Human Reproduction, University of Padova 4 ISTM-CNR, Padova The role of placenta during the fetal grown is well known. This tissue is exposed to the regulatory influence of many different substrates present either in maternal or in fetal circulation. Its functionality can be affected by changes of active substances present in both circulations and it can produce active molecules affecting mother and fetus independently. A pathological state, as the onset of gestational diabetes mellitus (GDM) necessarily reflects on the change of these equilibria. The present investigation was focused on the possible changes occurring in the placenta protein profile in presence of GDM. For this aim either the top-down or the bottom-up approaches were employed. The placenta samples from 20 healthy and from 20 GDM pregnant women were pooled. The two samples so obtained were analyzed by MALDI/MS and the proteins detected were tentatively identified on the basis of their molecular weight. Alternatively the two pools were analyzed by electrophoresis and the different bands obtained were digested by trypsin and the digestion products were analyzed by MALDI. Interestingly, aside quantitative changes observed in the protein profiles of healthy and GDM subjects, some glycated proteins have been detected. An example is represented by the SRRM1 protein, identified either in the diabetic placenta homogenate pool or in the control one by means of SDS-PAGE followed by MALDI/MS analysis of the in-gel tryptic digested. MALDI spectrum of the SRRM1 digestion products shows, in the case of diabetes, the presence of molecular species ascribable to glycation processes. Species at m/z 1406, for instance, can be explained by the condensation of three methylglyoxal (MGO) molecules. MS/MS experiments supports this hypothesis showing the presence of four arginine residues in the aminoacidic sequence of this molecular species, which could bind the MGO. 586 biochimica clinica, 2012, vol. 36, n. 6 P230 VALUTAZIONE COMPARATIVA DI UN METODO ENZIMATICO PER LA MISURA DEGLI ACIDI BILIARI CONIUGATI TOTALI SUL SISTEMA OLYMPUS AU 2700 RISPETTO AD UNA METODICA RADIOIMMUNOLOGICA R. Rosso, L. Motta, G. Vignati Laboratorio Analisi Chimico Cliniche e Centro Malattie Endocrine e Metaboliche, Ospedale "G.Fornaroli", Magenta (MI) La colestasi intraepatica in gravidanza (ICP) è sospettata nelle gravide che presentano combinazione di prurito cutaneo diffuso ed alterazioni dei test di funzionalità epatica. E’ un fattore di rischio per morte fetale in utero, frequente dopo la 37 WOP. La somministrazione di acido ursodesossicolico (UDCA) è il trattamento medico più efficace per migliorare la sintomatologia e arrivare al termine naturale della gravidanza. Misurazione e monitoraggio degli acidi biliari sono utili nel confermare la diagnosi e nel monitoraggio terapeutico. Materiali e metodi: Il metodo in uso (acidi biliari coniugati totali RIA, in fase solida ad esecuzione manuale; ICN Biomedicals, Pantec) ha come limite la tempestività della risposta; per migliorarla abbiamo valutato la determinazione del parametro sulla strumentazione automatica AU2700 (Beckman Coulter). Il metodo impiegato (Dyazime Laboratories) si basa sulla reazione reversibile di conversione degli acidi biliari in 3chetosteroidi e tio-NADH catalizzata dall’enzima 3-αidrossisteroide deidrogenasi. La formazione di tio-NADH viene determinata misurando la variazione di assorbanza a 405 nm. Abbiamo testato i campioni (n =145) pervenuti nel periodo con la metodica RIA e su AU2700; effettuato una verifica degli intervalli di riferimento; verificata la potenziale interferenza sui risultati da parte di UDCA, dichiarata dal produttore, sulle pazienti con ICP in trattamento con tale farmaco. Risultati: Variabilità analitica (inter-assay): CV tra 2.84 e 3,13%. Confronto su campioni di routine (n=113: y = 2.70 + 0.875x; r = 0.956. Parametri popolazione di riferimento (n=115): mediana=2,80; 2,5°-97,5° percentile=0,69-9,78. Pazienti in trattamento con UDCA (n=32): nessuna diversità di classificazione dei risultati rispetto al metodo RIA (che non risente di tale interferenza). Conclusioni: Visti i risultati ottenuti si è optato per l’introduzione del dosaggio su AU2700. Il tempo di risposta pienamente rispondente alle necessità cliniche (60 min) evidenzia un sicuro beneficio nella gestione delle pazienti con ICP. Favre N, Bourdel N, Sapin V, et al. Importance of bile acids for intra-hepatic cholestasis of pregnancy. Gynecol Obstet Fertil 2010;38:293-5. 44° Congresso Nazionale SIBioC - Riassunti Poster P231 DETERMINAZIONE DELL’EMOGLOBINA GLICATA IN CAMPIONI CON VARIANTI EMOGLOBINICHE: CONFRONTO TRA SEI DIVERSI ANALIZZATORI P232 DETERMINAZIONE DELL’EMOGLOBINA GLICATA MEDIANTE ELETTROFORESI CAPILLARE 1 1 1 2 1 L. Brugnolo , C. Artusi , G. Antonelli , M. Marinova , M. 1 1 Zaninotto , M. Plebani 1 1 2 M. Marinova , S. Altinier , C. Artusi , G. Antonelli , L. 1 1 1 Brugnolo , M. Zaninotto , M. Plebani 1 1 UOC Medicina di Laboratorio, Azienda OspedalieraUniversità degli Studi, Padova 2 Dip. di Medicina, Università degli Studi di Padova Introduzione: Il principio analitico di riferimento per la misura dell’emoglobina glicata (HbA1c) è la cromatografia di affinità al boronato che permette la separazione della frazione glicosilata dalla non-glicosilata. Per la sua determinazione routinaria, l’HPLC rappresenta la tecnica più diffusa in grado di offrire migliori prestazioni analitiche. Obiettivo: Confrontare sei diversi analizzatori per valutare le differenze nelle misure di HbA1c in presenza di diverse varianti emoglobiniche. Materiali e metodi: Sono stati raccolti campioni di sangue di pazienti afferenti all’UOC Medicina di Laboratorio con richiesta di HbA1c che presentavano alcune delle più comuni varianti emoglobiniche: HbS (n=35), HbD Punjab (n=15), HbHasharon (n=16), HbC (n=6), HbE (n=3) e altre non identificate (n=6). Tutti i campioni sono stati analizzati con Adams HA8160 TP (A Menarini Diagnostics), HLC-723 G8 (Tosoh Bioscience), Variant II modalità dual-kit e Turbo (Bio-Rad), Cobas 6000 (Roche Diagnostic) e confrontati con lo strumento Afinion (Sentinel CH) scelto come metodo di riferimento. I risultati sono stati elaborati statisticamente con Analyseit® Software. Risultati: I sei metodi sono stati messi a confronto attraverso la regressione lineare e l’analisi di BlandAltman. È stato riscontrato un bias statisticamente significativo (range) nella misura di HbA1c con tutti gli analizzatori: HbS (-4.6% Tosoh +11.3% BioRad Turbo), HbHasharon (-7.4% Menarini +6.1% BioRad dual-kit), HbD Punjab (-5.5% Menarini +7.8% BioRad Turbo). Per quanto concerne le altre varianti, data la scarsa numerosità, è stato valutata la mediana dei bias (range) dei valori ottenuti con tutti gli analizzatori confrontati con Afinion: HbC (-8.6% Roche +7.0% BioRad dual-kit), HbE (-71.0% BioRad dual-kit +2.2% BioRad Turbo), per le varianti non definite (-5.9% Menarini +5.1% BioRad Turbo). Conclusioni: I risultati ottenuti per la determinazione di HbA1c evidenziano differenze statisticamente significative in presenza di varianti emoglobiniche in base al sistema diagnostico utilizzato, con conseguente scarsa confrontabilità tra i differenti sistemi analitici. È stato invece precedentemente verificato che in campioni che non privi di varianti emoglobiniche gli analizzatori presentano una buona correlazione. Dip interaziendale Azienda Ospedaliera-Università degli Studi, Padova Servizio Medicina di Laboratorio 2 Dip di Medicina, Università degli Studi di Padova Introduzione: L’emoglobina glicata (HbA1c) è un biomarcatore “chiave” per il monitoraggio dell’equilibrio glicemico a medio-lungo termine nei pazienti diabetici. Attualmente, per la sua determinazione la HPLC rappresenta la tecnica di elezione per la maggiore sensibilità, precisione, accuratezza e specificità. Recentemente è stato introdotto in commercio Capillarys 2 Flex piercing, un sistema automatico di elettroforesi capillare per la separazione e la quantificazione di HbA1c. Obiettivi: Valutare le performance analitiche dello strumento Capillarys 2 Flex Piercing nella determinazione di HbA1c e valutare come variazioni quantitative o qualitative del pattern emoglobinico possano influenzare la sua quantificazione. Materiali e metodi: Sono stati raccolti campioni di sangue intero di pazienti privi di varianti emoglobiniche (n=79) e con alcune delle più comuni varianti: HbS, HbC, HbE e HbD (n=17). I campioni sono stati analizzati contemporaneamente con Capillarys 2 Flex Piercing (Sebia) e con Adams HA8160 TP (A. Menarini Diagnostics) e i risultati sono stati elaborati statisticamente con Analyse-it® Software. Risultati: I risultati ottenuti dalle prove di imprecisione, sia nella serie sia tra le serie, mostrano un CV< 3.7%. I due metodi, messi a confronto attraverso la regressione lineare e l’analisi di Bland-Altman, nel gruppo di pazienti privi di varianti emoglobiniche, presentano un’ottima correlazione (R2=0.97, p<0.0001) e un bias di 0.8 mmol/mol, statisticamente ma non clinicamente significativo. La scarsa numerosità del gruppo di pazienti con emoglobinopatie non consente di ottenere dati statistici affidabili. In pazienti con varianti HbS, HbC, HbD e HbE le concentrazioni di HbA1c ottenute con i due metodi, appaiono sovrapponibili. Conclusioni: Le prestazioni analitiche, sia in termini di imprecisione che correlazione con il metodo di riferimento, sono risultate molto soddisfacenti. Le più comuni varianti emoglobiniche studiate non hanno dimostrato interferenza analitica nel sistema di determinazione. La facilità d’uso, la robustezza e la produttività oraria attestano la possibile applicazione nella diagnostica clinica di laboratorio. biochimica clinica, 2012, vol. 36, n. 6 587 44° Congresso Nazionale SIBioC - Riassunti Poster P233 EMOGLOBINA GLICATA E APPROPRIATEZZA DELLE RICHIESTE NEL MONITORAGGIO DEL PAZIENTE DIABETICO 1 2 R. Marozzi , G. Catanoso P234 EVALUATION OF ANALYTICAL PERFORMANCE OF A NEW METHOD FOR HbA1c DETECTION C. Novembrino, N. Failla, M.G. Ratti, M.G. Meroni, L. Villanova, R. Maiavacca 1 Lab. Centrale Analisi Chimico Cliniche e Microbiologia, Fond. IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Milano Nel monitoraggio del paziente diabetico numerose linee guida sottolineano l'importanza del dosaggio dell'emoglobina glicata ad intervalli basati sui valori dell'esame stesso. Una corretta tempistica è in grado di garantire efficienza ed efficacia sia per il paziente che per il sistema sanitario. Come suggerito da ADA e NICE si è considerato come cut-off di buon controllo del diabete il valore di 53 mmol/mol. Sono stati estratti i dati dal 2002 al 2012 dei dosaggi delle emoglobine glicate eseguiti presso il Laboratorio di Iseo. Ognuno dei 127907 risultati ottenuti ed elaborabili in modo anonimo per paziente è stato classificato secondo il grado di coerenza alle linee guida, ottenendo una suddivisione in richiesta corretta o anticipata (sovra-richiesta) o in ritardo (sotto-richiesta). Si è così ricavato che il 57,8% delle richieste è stata eseguita in tempi corretti (34,8% diabete non sotto controllo e 23,0% in controllo), il 22,7% in anticipo (media 99,6 giorni), il 19,5% in ritardo (media 370 giorni). Non sono state osservate differenze significative rispetto al sesso o all'età (cut-off 40 anni). Risultati diversi sono stati riscontrati tra medici di base e specialisti. Applicando una tolleranza di 14 giorni ai tempi d'esecuzione, si ricava che il 65,0% delle richieste è stata eseguita nei tempi corretti (38,9% diabete non sotto controllo e 26,1% in controllo); il 19,6% in anticipo, il 15,4% in ritardo. Il risultato del 42,2% delle richieste effettuate in tempi non adeguati (35,0% se corretto per tolleranza) permette di affermare che esiste un margine di miglioramento nella gestione del paziente diabetico, in particolare per garantire un'efficace valutazione del controllo della patologia. Sarebbe quindi opportuno attivare un progetto di informazione e sensibilizzazione dei medici affinché le richieste siano maggiormente coerenti alle linee guida. American Diabetes Association. Standards of medical care in diabetes: 2012. Diabetes Care 2012;35(Suppl 1): S11-63. Background: Glycated hemoglobin (HbA1c) is a biomarker for monitoring long-term glycemic status in diabetic patients. Capillarys 2 Flex Piercing is a capillary electrophoresis (CE) system produced by Sebia; the Capillarys HbA1c kit is designed (according to IFCC recommendations) for separating and quantifying HbA1c on the above-mentioned analyzer and, due to the enhanced resolution, is able to detect hemoglobin variants. Aim of this study was to assess the analytical performance of this new method for routinely HbA1c quantification in diabetic patients, including uremic and carriers of inherited hemoglobin disorders. A method comparison was therefore performed on 535 blood samples correlating results with those obtained with our routine method (HPLC Variant II Biorad); the presence of interfering substances was evaluated with special attention to fetal hemoglobin (HbF), carbamylated Hb (cHb) and frequent Hb variants. The interference of cHb was assessed by incubating blood samples with different levels of HbA1c (low, medium, high) with increasing concentrations of sodium cyanate (0.25 mM-0.5mM-1mM-2mM). The effect of HbF concentration was investigated by mixing adult blood samples (at 3 different HbA1c concentrations) with neonatal blood in order to obtain different HbF levels in the final pool. Results: Our results showed a good correlation with a coefficient r=0.992; Bland-Altman plot showed that only 28/535 samples (5.2%) were discordant with differences outside the range mean ±2SD. HbA1c quantification was accurate and independent of the presence of hemoglobinopathies and common hemoglobin interferences. HbA1c detection on CE system was not affected by HbF percentages in the evaluated range (up to 15% of HbF) and by cHb up to 9.2%, resulting from in vitro carbamylation with 2 mM solution of sodium cyanate. Conclusions: On the basis of the present results and given the short time of the analysis and the high throughput, the use of Capillarys HbA1c kit on Capillarys 2 Flex Piercing is suitable for routinely glycemic control in diabetic patients. Urrechaga E. High-resolution HbA(1c) separation and hemoglobinopathy detection with capillary electrophoresis. Am J Clin Pathol 2012;138:448-56. Lab. Analisi P.O. di Iseo - A.O. Chiari (BS) 2 Lab. Analisi P.O. di Chiari - A.O. Chiari (BS) 588 biochimica clinica, 2012, vol. 36, n. 6 44° Congresso Nazionale SIBioC - Riassunti Poster P237 RELATIONSHIP BETWEEN ß-C-TELOPEPTIDES OF TYPE I COLLAGEN (ß-CTX) AND FASTING PLASMA GLUCOSE IN AN UNSELECTED POPULATION OF OUTPATIENTS 1 2 1 M. Montagnana , G. Lippi , E. Danese , G. 1 1 Brocco , G.C. Guidi 1 Sez. di Biochimica Clinica, Dip. di Scienze della Vita e della Riproduzione, AOUI di Verona 2 U.O. di Diagnostica Ematochimica, Azienda Ospedaliero-Universitaria di Parma Background: Although it is conventionally recognized that bone metabolism is influenced by ambient glucose levels, controversial information is available on the relationship between markers of bone turnover and glucose status. Methods: We performed a retrospective analysis on the database of our Laboratory Information System to retrieve results of fasting plasma glucose (FPG) and serum ß-Ctelopeptides of type I collagen (ß-CTX) tests, which were performed on consecutive outpatients referred by general practitioners for routine blood testing over the last 2 years. Results: Cumulative results for FPG and serum ß-CTX tests were retrieved for 733 outpatients >20 years old. The mean ß-CTX value of subjects (n=34) with FPG ≥7.0 mmol/L was significantly lower than that of the euglycaemic (FPG <5.6 mmol/L, n=533) population (0.334 ng/mL, 95%CI: 0.068-0.651 ng/mL versus 0.417 ng/mL, 95%CI: 0.118-1.853 ng/mL; p=0.03). Moreover, the mean ß-CTX value of subjects (n=204) with Impaired Fasting Glucose (FPG levels 5.6 mmol/L to 6.9 mmol/L) was significantly lower than that of the euglycaemic population (0.405 ng/mL, 95%CI: 0.114-0.850 versus 0.417 ng/ mL, 95%CI: 0.118-1.853 ng/mL; p=0.01). A negative significant correlation (Spearman’s test) was observed between ß-CTX and FPG (r=-0.10, p=0.007). Conclusions: Results of our retrospective analysis on an unselected population of outpatients are consistent with the hypothesis that bone turnover, as reflected by serum ß-CTX values, might be somehow down regulated in hyperglycaemic subjects. 590 biochimica clinica, 2012, vol. 36, n. 6 P238 STUDIO CROSS-OVER RANDOMIZZATO, IN DOPPIO CIECO, CON PLACEBO PER VALUTARE L’EFFETTO DELL’ACIDO α-LIPOICO COME INTEGRATORE ALIMENTARE SULL’OMEOSTASI DEL GLUCOSIO NEI PAZIENTI CON DIABETE DI TIPO 2 1 1 2 1 R. Testa , M. Boemi , R. Festa , M. Cucchi , A. 3 1 4 4 Ceriello , A.R. Bonfigli , F. Busco , R. Galeazzi , A. 4 Marsiali 1 Centro Ricerche Metaboliche sul Diabete e gli Alimenti, INRCA, Ancona 2 Dip. Scienze Cliniche e Molecolari, Università Politecnica delle Marche 3 August Pi Sunyer Institute of Biomedical Investigations, Spain 4 Laboratorio Analisi, INRCA, Ancona Scopo: L’acido alfa-lipoico (ALA), composto antiossidante che ricopre un ruolo chiave nel metabolismo energetico cellulare, ha molte potenziali applicazioni per vari aspetti della patologia del diabete contribuendo alla normalizzazione del livello di glucosio nel sangue. Obiettivo primario di questo studio è stato quello di investigare l’effetto della somministrazione di ALA come integratore alimentare sull’omeostasi del glucosio nei pazienti con diabete di tipo 2 in terapia combinata con metformina-sulfaniluree. Metodologia: Sono stati studiati 34 pazienti (età media 66.7±4.3 anni) con diabete di tipo 2. Lo studio presentava il seguente schema: studio cross-over, randomizzato, in doppio cieco. I pazienti sono stati randomizzati in due gruppi: il primo gruppo (n=17) è stato trattato con ALA, 1 compressa da 600 mg/die, per 30 giorni, il secondo gruppo (n=17) è stato trattato con 1 compressa di placebo/die, per 30 giorni. Al termine del primo periodo di trattamento è seguito un periodo di 15 giorni di washout e quindi il cross-over e la seconda fase di trattamento, sempre di 30 giorni, in cui i pazienti appartenenti ai due bracci sono stati incrociati per le loro rispettive terapie. Risultati: Nessuna differenza statisticamente significativa è stata trovata per la variabile KITT (indice K del test di tolleranza all’insulina) e per l’indice HOMA-IR dopo trattamento, evidenziando che l’ALA non ha determinato variazioni significative dell’insulino resistenza. Al contrario, la concentrazione della glicemia a digiuno dopo trattamento con ALA era significativamente più bassa rispetto ai valori dopo trattamento con placebo (p=0.008). Differenze significative sono state trovate anche per l’Insulina a digiuno (p=0.011), il C-peptide (p=0.038), e il GLP-1 (p=0.016). Conclusioni: La somministrazione orale di ALA in pazienti diabetici di tipo 2 trattati con metformina e sulfaniluree comporta dei miglioramenti sull’omeostasi del glucosio probabilmente mediati da un effetto “incretinico” sulla produzione del GLP-1. Ceriello A, Motz E. Is oxidative stress the pathogenic mechanism underlying insulin resistance, diabetes, and cardiovascular disease? The common soil hypothesis revisited. Arterioscler Thromb Vasc Biol 2004;24:816-23. 44° Congresso Nazionale SIBioC - Riassunti Poster P239 TERAPIA COMBINATA NEL TRATTAMENTO DEL DIABETE MELLITO TIPO II: ATTIVITA’ FISICA E PROGRAMMA DIETETICO CONTROLLATO 1 2 P240 THE INTEGRATED MANAGEMENT OF THE DIABETIC PATIENT "COLLABORATION BETWEEN BLOOD DRAWING CENTER AND THE GENERAL PRACTICE DOCTORS OF THE DISTRICT" 3 G. Mattera , M. Di Meglio , L. Mattera , A. 1 1 Castagliuolo , M.C. Stanziola A.M. Basile, C. Mastrorocco, S. Lenoci 1 Centro Prelievi Lab. di Patologia Clinica Osp. Miulli, Acquaviva delle Fonti, Bari U.O. Patologia Clinica , Osp. A.Rizzoli, Lacco Ameno Ischia (Na) 2 Università di Napoli "Parthenope", Scienze delle attività motorie preventive ed adattative 3 M.G., Ischia (Na) Il diabete mellito di tipo II mostra un trend in ascesa in termini di morbidita’ e mortalita’ anche per la mancanza di programmi terapeutici ed educazionali standardizzati. Sebbene i presidi terapeutici medici attuali determinano generalmente un buon controllo dei livelli glicemici ematici, la progressione e l’impegno multi organico restano tuttavia immodificati nella storia naturale di malattia. L’obesita’ e le abitudini sedentarie favoriscono una scarsa “compliance” ed una difficile attuazione dei programmi di training proposti. E’ stato condotto uno studio pilota in 18 pazienti (50-70 anni), affetti da diabete mellito tipo II da almeno 10 anni in trattamento regolare con antidiabetici orali in scarso compenso glicemico, valutato mediante dosaggi di HbA1c (media 8.63%) suddivisi in 3 gruppi di sei persone e per un periodo di 12 settimane. Un primo gruppo è stato sottoposto esclusivamente ad un programma di attività fisica prima di modica intensita’ e poi aerobica fino al raggiungimento dello steady state. Un secondo gruppo di pazienti è stato sottoposto ad attività fisica e ad un piano alimentare con dieta ricca in fibre ed apporto calorico di circa 1500 kcal/ die. Un terzo gruppo era di controllo. La determinazione dei livelli di HbA1c veniva eseguita al T0 e dopo 3 mesi. Il gruppo di soggetti sottoposto sia ad un regime alimentare controllato che ad esercizio fisico adeguato mostrava, dopo 12 settimane, una riduzione dei livelli di HbA1c statisticamente significativa rispetto ai valori basali di circa 1.1% (p < 0.01) ed una migliore endurance sia in termini di resistenza fisica che di aderenza al trattamento. Questo studio pilota ha evidenziato come il trattamento combinato che prevede un’attivita’ fisica moderata ed un programma alimentare possa determinare: - risposte favorevoli in particolare sul controllo della glicemia; - migliore performance dei pazienti diabetici sia in termini di resistenza che di adeguamento al trattamento non farmacologico; - identificare i pazienti responder scegliendo programmi di attività fisica personalizzati. Introduction: Diabetes takes the sixth place among the most common chronic diseases in Italy, with an increasing trend in recent years. Apulia confirms this trend with an increase from 5.4% in 2003 to 6.5% in 2008. The blood drawing center in Miulli Hospital participates in the Regional Project "Development of taking care of the diabetic patient to reduce the risk of complications" through an active collaboration between Hospital and General Practitioners (GPs). Objectives: Reporting on an "acceptable" range, through a careful and constant monitoring, the following parameters: blood pressure, glycated hemoglobin, BMI, total cholesterol, HDL, LDL, creatinine, micro albuminuria, GFR. Methods: In the first three months of 2012, 158 diabetic patients were subjected to blood tests: (glycosylated hemoglobin, total cholesterol, HDL, LDL, creatinine, microalbuminuria). The data contained in a database were sent to GPs. Results: 97.9% of patients have type 2 diabetes, the remaining have type 1, aged 68.7 ± 12.0 years, disease duration 11.1 ± 7.5 years, BMI 28.6 ± 5.1 kg/m². Insulin dependent patients are 12%, patients receiving hypoglycemic 83%, 5% no therapy. Glycosylated Hb <48 mmol/mol -37% (53-98 mmol/mol) - 57% (100-113 mmol/ mol) -6%, total cholesterol >200 mg/dL -36%, HDL >96 mg/dL -1%; LDL (130-159 mg/dL) -27%, (160-189 mg/ dL) -9%; creatinine >1,30 mg/dL -3.9%; microalbuminuria >30.0 mg/L -23%; GFR <90 mL/min/1.73 m² -0.8%. Conclusions: The project is in the initial phase. The first results say diabetic patients assisted by GPs show a fair compensation glyco-metabolic. Italian data show that the synergy between the expert assistance of the structures of diabetes and General Medicine reduces up to 65% of hospitalization of diabetic patients, recovery up to 25% and triples the likelihood that the patient is monitored according to the guidelines. biochimica clinica, 2012, vol. 36, n. 6 591 44° Congresso Nazionale SIBioC - Riassunti Poster P241 VALUTAZIONE DEL SISTEMA HPLC “HA-8180V” PER LA DETERMINAZIONE DELL’EMOGLOBINA GLICATA P242 VALUTAZIONE DELLE PERFORMANCE DI GLUCOMETRI IN USO PRESSO L’ASUR MARCHE AREA VASTA 2, SEDE SENIGALLIA C. Villa, G. Scarsi S. Barocci , M. Vidali , L. Petrolati , A. Tarsi , M. 1 1 3 3 3 Mecozzi , G. Carta , G. Tinti , S. Rilli , S. Manfrini Laboratorio Analisi A.O. "S. Antonio Abate" Gallarate L’utilità della determinazione dell'emoglobina glicata (HbA1c) nel mantenimento del controllo glico-metabolico su pazienti con diabete mellito è ampiamente documentata in letteratura. In questi ultimi anni, per migliorare le performances analitiche del test, IFCC ha prodotto uno standard internazionale sul quale calibrare i sistemi in uso; inoltre sono state redatte raccomandazioni riguardanti la determinazione di HbA1c, l’espressione dei risultati e l’errore analitico totale massimo accettabile. Scopo del lavoro è la valutazione dello strumento ADAMS A1C HA-8180V, distribuito da Menarini S.p.a., sia per gli aspetti analitici che gestionali. Imprecisione nella serie: sono stati analizzati campioni con HbA1c bassa, normale, border line ed alta; ogni campione è stato ripetuto 20 volte i risultati sono: basso: media 25,78 mmol/mol c.v. 0,72%, normale: media 38,33 mmol/mol c.v. 0,25%, borderline: media 49.97 mmol/mol c.v. 0,22%, alto: media 106,9 mmol/mol c.v. 0,24%. Imprecisione tra serie: sono stati analizzati per 15 giorni due controlli (Glyco Hb control) con valori di HbA1c normale e patologico. I risultati sono: low: media 41,47 mmol/mol c.v. 1,12%, high: media 96,87 mmol/mol c.v. 0,92%. Confronto: HA-8180V vs Variant II; è stata determinata l’HbA1c di 329 soggetti (293 diabetici e 36 non diabetici) sugli strumenti HA-8180V e Variant II (Bio-Rad). La retta di regressione ha una pendenza di 0,9965 con intercetta di 0,7539 e un coefficiente di correlazione r di 0,995. Lo strumento in prova risponde alle raccomandazioni proposte. L’imprecisione è molto contenuta in un ampio range di concentrazioni sia nella serie che tra serie; inoltre l’impiego di calibratori allineati allo standard IFCC ha ridotto l’inesattezza della misura come dimostra il confronto effettuato con un altro sistema analitico. Si apprezzano anche la semplicità operativa e l’alta cadenza analitica. 592 biochimica clinica, 2012, vol. 36, n. 6 1 2 1 1 1 ASUR MARCHE AV2, U.O. Patologia Clinica, Senigallia (AN) 2 Dipartimento di Scienze Mediche, Università Amedeo Avogadro del Piemonte dell'Est e Unità di Chimica Clinica dell'Ospedale Maggiore della Carità, Novara 3 ASUR MARCHE AV2, Centro Antidiabetico, Senigallia (AN) Obiettivi: Gli strumenti portatili per la determinazione rapida della glicemia su sangue capillare (glucometri) sono indispensabili per l’autocontrollo glicemico del paziente. L'obiettivo del presente studio è la valutazione delle performance dei glucometri in dotazione presso il Presidio Ospedaliero di Senigallia. Metodologia: Sono stati selezionati, come popolazione di studio, n. 50 pazienti del Centro Antidiabetico del Presidio Ospedaliero di Senigallia, che sono stati sottoposti nello stesso tempo a prelievo ematico e puntura con lancetta per la determinazione diretta della glicemia con glucometro. Sono stati considerati nello studio n. 6 glucometri delle aziende Sanofi-Aventis, Bayer, Roche, Lifescan e due della Menarini, posti a confronto con il sistema Vitros 5600 (Ortho-Clinical Diagnostics), utilizzato come metodo di riferimento. Questo strumento permette anche la determinazione dell’idoneità del campione (presenza di emolisi o meno). Sui dati ottenuti dai sei glucometri, rispetto al metodo di riferimento, sono state eseguite le analisi di regressione non parametrica di Passing-Bablok e quella di Bland-Altman. Risultati: L’analisi di Passing-Bablok ha evidenziato un errore sistematico costante nei reflettometri n. 1 (intercetta 12,8; LL95% 3,38-UL95% 21,31), n. 3 (intercetta 20,16; LL95% 6,63-UL95% 30,40) e n. 6 (intercetta 13,6; LL95% 4,69-UL95% 22,57), che potrebbe essere dovuto alla differente matrice utilizzata (sangue intero vs siero), effetto che invece non è rilevante nei glucometri n. 2, n. 4 e n. 5. L’analisi di Bland-Altman ha evidenziato una buona performance di tutti i glucometri. Tutti hanno un valore negativo della media delle differenze, rispetto al saggio di riferimento, ad indicare che tutti i sistemi sovrastimano. I glucometri che hanno le migliori performance, secondo l’analisi di regressione, sono il n. 2 ed il n. 5, sebbene l’analisi di Bland-Altman abbia evidenziato che il primo, il secondo, il quinto ed il sesto sono caratterizzati da errore proporzionale all’aumentare dei valori della glicemia. La sovrastima massima dei glucometri (media delle differenze fra metodo di riferimento e glucometro) è risultata essere quella del 4 (16,37 mg/dL). 44° Congresso Nazionale SIBioC - Riassunti Poster P245 CRP ED EMOCROMO IN POCT: VALUTAZIONE ANALITICA DEL METODO MICROSEMI CRP-HORIBA L. Varraso, R. Lovero, E. Mascolo, A. Mileti, I. Specchia, E. Cleopazzo, F. Di Serio P246 FUNZIONALITA’ OPERATIVA E PERFORMANCE ANALITICHE DI EMOGAS ANALIZZATORI A CARTUCCIA E DI SISTEMI ANALITICI TRADIZIONALI IN UN REPARTO DI TERAPIA INTENSIVA 1 U.O.C. Patologia Clinica I Azienda Ospedaliera Policlinico Bari Il dosaggio della CRP e la valutazione dell’emocromo sono eseguiti di routine anche nei reparti di neonatologia: la peculiarità dei piccoli pazienti, spesso prematuri, pone delle criticità legate alla difficoltà della raccolta del campione ematico. Scopo: Valutare l’accuratezza del metodo Microsemi CRP (HORIBA) quale POCT per la determinazione della CRP e dell’emocromo su campione da capillare. Materiali e metodi: Tre livelli di controllo (HORIBA) sono stati utilizzati per la valutazione della precisione. La CRP e l’emocromo di 50 pazienti neonati, sono stati determinati sull’analizzatore HORIBA e i dati confrontati con quelli misurati nei rispettivi campioni di siero (Dimension Vista; CRP = 3-210 mg/L) e di sangue-EDTA ( ADVIA 2120). I dati sono stati valutati con la regressione di Passing and Bablok e l’analisi di Bland and Altman. Risultati: Valutazione della CRP. Lo studio di precisione mostrava CVs% compresi tra 0.80 e 3.6. Lo studio di comparazione con il metodo Vista evidenziava i seguenti risultati: y = 1.09 (95% CI, da -0.28 a 2.97) + 0.98 (95% CI, da 0.91 a 1.04) x; bias assoluto = -0.91 mg/ L (95% CI = -5.52 a 3.69). Valutazione dei parametri emocromocitometrici. WBC: CVs% da 0.5 a 2.5; bias assoluto = -0.54 (95% CI -0.79 a -0,19). RBC: CVs% da 0.5 a 1.0; bias assoluto = -0.27 (95% CI -0.22 a -0.13). PLT: CVs% da 2.4 a 2.9; bias assoluto = -6.84 (95% CI -12.92 a 1.54). HB: CVs% da 0.27 a 0.83; bias assoluto = 0.033 (95% CI -0.045 a 0.12). Conclusione: I dati preliminari mostrano che il metodo Microsemi CRP fornisce risultati riproducibili. La presenza di un bias non statisticamente significativo per CRP, HB e PLT non pone rischi di interpretazione rispetto ai risultati ottenuti in laboratorio. La semplicità d’uso e la possibilità di misurare su capillare contestualmente CRP ed emocromo, suggeriscono che l’analizzatore Microsemi CRP può essere utilizzato quale POCT in reparti particolarmente critici quale la neonatologia. 594 biochimica clinica, 2012, vol. 36, n. 6 1 2 1 S. Salti , S. Rapi , M. Bonizzoli , F. Veroni , A. 2 1 2 Peris , A. Ognibene , P. Dammiano 1 Laboratorio Centrale, Dipartimento di Laboratorio A.O.U. Careggi Firenze 2 Unità Terapia Intensiva, A.O.U. Careggi Firenze Introduzione: Le linee guida sul Risk managements (EP23-A) introducono l’uso di standard interni per il controllo della strumentazione rendendo i sistemi analitici a cartuccia un opzione pienamente praticabile. In questo studio un sistema a cartuccia (GEM 400 IL) è stato affiancato alla strumentazione attualmente in uso (ABL 800 Radiometer) allo scopo di verificare le performance diagnostiche e l’impatto dei 2 sistemi nel flusso di lavoro. Materiali e metodi: Lo studio è stato condotto presso un reparto di terapia intensive con 10 letti (circa 3000 emogas/mese). I 26 infermieri sono stati invitati ad eseguire gli emogas su entrambi i sistemi ed a registrare gli eventi significativi (codificati come: ritardi >5’, ritardi < 5’, errori di campionamento, errori analitici). Le registrazioni degli operatori sono state integrate con i system log strumentali. Le performance dei test principali (pH, Hb, Hct, PO2, PCO2, K, Na, Cl, Ca2+, Glu, TBil, Lattato) sono state valutate mediante regressione lineare ed analisi di Bland Altman. Risultati: Sono stati analizzati 2784 campioni sull’ABL; 1205 sul GEM e 1157 su entrambi i sistemi. I principali blocchi operativi sono risultati 214 flag (7.7%) su ABL e 83 problemi di campionamento, (6.9%) sul GEM. Sono state raccolte 264 segnalazioni; 89 (33.7%) riguardavano l’ABL (28% ritardi < 5 min, 16% ritardi > 5 min, 4 errori campionamento, 46 flag analitici) e 175 (66.3%) il GEM (50% ritardi < 5 min, 13% ritardi > 5 min, 35% errori campionamento e 3 flag analitici). Le performance analitiche sono state studiate su 1002 campioni. I coefficienti angolari dei test sono risultati compresi tra 0.92 ed 1.047, l’intercetta tra -3.14 e 5.21 ed i coefficienti di correlazione di Pearson tra 0.92 e 0.996. Un Errore totale di -38.8% è stato trovato per la bilirubina totale mentre per gli altri analiti gli errori totali sono risultati <4%. Discussione: Lo studio conferma la buona correlazione esistente tra i 2 sistemi. Si evidenzia la maggiore disponibilità del sistema aperto e la strategia più ‘garantista’ in fase di refertazione dei sistemi a cartuccia. Indipendente dal sistema analitico utilizzato resta l’importanza di una revisione dei risultati analitici prima del loro utilizzo nella pratica clinica 44° Congresso Nazionale SIBioC - Riassunti Poster P247 IL LABORATORIO NELLA DIAGNOSI DI DIABETE MELLITO: CONFRONTO TRA DUE SISTEMI DI DOSAGGIO DEL GLUCOSIO EMATICO IN POCT P248 POINT OF CARE TESTING E SUA INTEGRAZIONE NEL LIS: VALUTAZIONE DELLE NON CONFORMITÀ UN ANNO DOPO M.A. Isgrò, R. Morelli, L. Colacicco, C. Zuppi, D. Scribano L. Varraso, R. Lovero, I. Speccia, F. Di Serio Dip. Medicina di Laboratorio, Cattedra di Biochimica Clinica e Biologia Molecolare Clinica, U.O.C. Analisi 1, Pol." A. Gemelli", Università Cattolica del Sacro Cuore, Roma Introduzione: L’utilizzo dei glucometri nelle strutture ospedaliere è una sfida organizzativa per il laboratorio che deve scegliere la strumentazione analitica, addestrare il personale infermieristico e soprattutto assicurare la qualità dei risultati con un costante CQI. Data l’importanza che ha la determinazione seriata della glicemia nel monitoraggio della terapia antidiabetica, abbiamo valutato l’accuratezza di due sistemi di dosaggio in Point-of-Care Testing (POCT) del glucosio ematico: StatStrip Xpress (Menarini) e Breeze®2 (Bayer) in uso presso il nostro policlinico. Materiali e metodi: Sono stati arruolati 148 pazienti afferenti presso la nostra struttura ospedaliera per una valutazione dello stato glico-metabolico. A ciascun paziente è stata determinata la glicemia da sangue intero sugli strumenti StatStrip Xpress e Breeze®2 e da plasma fluorurato con esochinasi (Roche/Hitachi Cobas 8000). Sono stati calcolati i valori di media, D.S. e CV intraed inter-assay dei controlli ed analizzati statisticamente i risultati delle determinazioni. Risultati e conclusioni: I valori di media e CV intraed inter-assay dei controlli hanno confermato il corretto funzionamento dei glucometri. Entrambi gli strumenti mostrano una buona correlazione rispetto al sistema 2 di riferimento (R = 0.9459 e 0.9420, rispettivamente). Tuttavia l’analisi mediante plot di Bland-Altman ha rivelato una maggiore sovrastima del sistema StatStrip Xpress rispetto al sistema Breeze®2 (13.73 mg/dL vs. 4.57 mg/dL, rispettivamente); l’entità della sovrastima per il sistema Breeze®2 tende a ridursi per valori elevati di glicemia (>150 mg/dL). Entrambi i sistemi si presentano come strumentazioni affidabili, di facile comprensione ed utilizzo e sicuri in quanto dotati di espulsione automatica della striscia reattiva dopo l’utilizzo. Inoltre, il sistema Breeze®2 è in grado di aspirare il campione di sangue tramite sistema capillare. Tuttavia soltanto lo StatStrip Xpress ha a disposizione un sistema di connettività in rete (StatStrip Connectivity meter), imprescindibile dalla gestione del POCT nell’ambito del laboratorio, facilitando le fasi di riorganizzazione che passano attraverso il processo di consolidamento e decentralizzazione degli esami. U. O. Patologia Clinica I Azienda Ospedaliero Universitaria Policlinico Bari Scopo: Nei 12 mesi che hanno fatto seguito all’interfacciamento dei GEM 4000 al LIS e con il conseguente avviamento di una nuova modalità operativa, sono state monitorate tutte le attività focalizzando l’attenzione su eventuali punti di forza e punti di debolezza. Un passo avanti rispetto allo status precedente è stato fatto reclutando una U.O di particolare criticità, quale il Pronto Soccorso. Materiali e metodi: Le non conformità (NC) che hanno determinato il blocco della trasmissione dei dati dai POCT al LIS sono state valutate e confrontate con lo stesso trimestre dell’anno precedente (Marzo-Maggio 2011). Le NC sono state classificate in tre classi: esame programmato ma non eseguito in modalità LIS (classe I); esame programmato con codice di accettazione errato (classe II); riutilizzo dello stesso barcode (classe III). Risultati: Il carico di lavoro nel trimestre 2012 (n. 3081 emogas) evidenziava un incremento del 39,4% rispetto al periodo precedente (n. 2210 emogas); contestualmente si registrava un decremento delle NC dal 5.5% al 3.5%. L’analisi delle NC per singole classi, evidenziava una diversa distribuzione rispetto al 2011. La NC a più alta frequenza era quella di classe I: 76% vs 52% nel 2011. La NC di classe II presentava un significativo decremento: 7% vs 32% nel 2011. La NC di classe III confermava il dato del 2011: 19%. Conclusioni: L’inclusione della U.O. di Pronto Soccorso, a causa dell’iniziale inesperienza da parte degli operatori, ha mascherato il significativo decremento delle NC registrate negli altri reparti sottoposti già da un anno a monitoraggio costante. In contrapposizione a questa (negativa) evidenza, tuttavia, dobbiamo sottolineare l’impatto positivo che l’introduzione di questa nuova modalità di lavoro ha avuto sull’operatività del PS, anche in rapporto alla collaborazione degli operatori del PS con il laboratorio. I dati suggeriscono che un reclutamento graduale dei reparti per l’interfacciamento dei GEM 4000 al LIS, attraverso il sistema GEM Web Plus, unitamente ad un feedback costante e percorsi di formazione da parte del laboratorio, consente una progressiva riduzione delle NC e un miglioramento del flusso operativo, adeguato alle specifiche esigenze dei reparti. biochimica clinica, 2012, vol. 36, n. 6 595 44° Congresso Nazionale SIBioC - Riassunti Poster P249 QUALITY ASSESSMENT PROGRAM ON POCT GLUCOSE METERS ACCUCHECK INFORM II OPERATED BY CENTRAL LABORATORY: PERFORMANCE OF DEVICES AND METHOD RELIABILITY S. Salti, B. Peruzzi, F. Veroni, S. Rapi Lab. generale, Dipartimento di Laboratorio, A.O.U. Careggi Firenze Background: POCT guidelines require to submit devices at EQA program or at periodic evaluation of performance using control material different to normal reference. EQA program available in Italy for POC glucometer don’t allow monitoring of more than 20 devices moreover monitoring of a large number of devices results in a significant increasing of cost. Aims of the present reports was to verify performance of devices and reliability and working time of a quality assessment strategy operated by Laboratory. Materials and methods: 2 pool of human serum was obtained by residual materials from inpatients and tested for viral infections. Glucose concentration with laboratory method (ADVIA 2400, Siemens) results: L1=70.3+/-0.02 mg/dL and L2=296+/-0.05 mg/dL (mean and s.d by 8 runs). Both samples were analyzed in two different days (at least one month of delay) on 50 POCT devices (Accuchech Inform2. Roche); overall results were used for analytical performance evaluation. Working time for sample preparations, delivery and running were separately registered. Results: Mean values of all instruments results L1=80.23+/-1.85 and L2=308.3+/-8.3, bias between Laboratory and POC device (without reference method) results L1=6.59% and L2=2.03%. No total error over 15% were observed in the 200 of collected data; 1 data show a total error >10%; and 7 samples show a total errors > 5%. Working time results of 15 min for single device for laboratory and 7+/-5 min for devices for nurses. Discussion: Overall comparison confirm the good correlation between POCT an laboratory; a bias >5% may be expected for low values. Inter-devices variability and samples with significant standard error results very low. An accurate evaluation of available instruments may be performed in hospital starting from laboratory residual materials; the overall procedure results time consuming and is not so easy to perform in a hospital spread in many building. Main difficult are related to samples selections and delivered. A total amount of 24 working hours for nurses and 18 hours for laboratory operators results in our experience. EN ISO 22870:2006. Point of care testing (POCT) – Requirements for quality and competence. 596 biochimica clinica, 2012, vol. 36, n. 6 P250 THE GOVERNANCE PROCESSES OF THE LABORATORY FOR PERFORMING EXAMINATIONS OF POCT AT UTAP 1 1 1 1 S. Bedendo , M. Fagiano , N. Braga , D. Zaghi , A. 2 3 1 Menardo , A. Pozzato , A. Camerotto 1 SOC Medicina di Laboratorio, ULSS 18 Rovigo UTAP "Medici piu'" Lendinara, ULSS 18 Rovigo 3 SOC Ostetricia e Ginecologia, ULSS 18 Rovigo 2 Objective: The UTAP (Territorial Unit of Primary Care) clinics are general practitioners associated with the purpose of providing assistance to patients, integrated with the hospital. In the area of ULSS 18, there are two active UTAP locations. Describe the process management of POCT tests performed at the UTAP to ensure tests with TAT and adequate quality standards to improve clinical decision making. Methodology: The choice of instrumentation was carried out considering as priority areas: - impact in the organizational process POCT: simplicity and ease of use by operators; - specifications of instrumentation and reagents: instrumental analytical quality, storage conditions and expiry date of reagents. Our tools and equipment are inventoried as the SOC Laboratory Medicine; reagents order to the companies is provided by a Technical Coordinator of the Laboratory and codified in cost centers. The instruments are connected by a HL7 standard network management software (Net Care, Menarini) to the Laboratory for the purpose of a real-time governance (QC, monitoring results). Results: We have defined the administrative procedures for acceptance of patients, the management procedures throughtout the analytical process and in particular: traceability of the sample, values of clinical alerting, management and quality assurance of analytical instrumentation. Roles - With specific management procedures have been defined roles and responsibilities for the various operators involved in the process: UTAP operator (doctor or nurse), nursing POCT Manager, Technical Manager of the Laboratory POCT, POCT Manager computer, UTAP Medical Director, Laboratory Supervisor. Responsibility - Director of Laboratory Medicine: responsibility of the acquisition of equipment, software and materials, the results of tests performed in the manner provided. General Practitioners: responsibility of clinical use of the results. UTAP operators: they are not accountable for results, but the respect of the timely and correct procedures. Conclusions: The laboratory governance of processes POCT UTAP is a necessary foundation to ensure proper management efficiency and analytical quality. SiBioC Documents. Recommendations for the implementation and management of the POCT. Biochim Clin 2011;35:242-52. 44° Congresso Nazionale SIBioC - Riassunti Poster P251 ASSESSING 25-HYDROXYVITAMIN D NUTRITIONAL STATUS IN THE NORTH-WESTERN ITALY P252 PROTEOMICS OF ARTICULAR OSTEOARTHRITIC CHONDROCYTES EXPOSED TO ELECTROMAGNETIC FIELDS M. Vidali, G. Bellomo, M. Basile 3 Dept. of Health Sciences, University “Amedeo Avogadro” of East Piedmont, and Clinical Chemistry Unit, Maggiore della Carità Hospital, Novara, Italy Introduction: Many studies have recently reported on the widespread prevalence of deficiency/insufficiency of vitamin D across European countries, particularly in the elderly and adolescents. However, the variation in vitamin D status both between as well within countries is very high. Most of the published studies on vitamin D levels in Italy have been performed in specific ageor disease- subgroups; however, few data are available on the nutritional status of vitamin D in the adult general population. We report on vitamin D levels evaluated with a single analytical method in a large sample of adults from North-Western Italy. Association with age, sex and season was also evaluated. Materials and methods: 13110 cases (24% males, 76% females; median age 67y, IQR 56-77) were collected in the North-Eastern of Piedmont (North-Western Italy) and 25-OH-vitamin D levels were measured by Liaison® 25 OH Vitamin D total (DiaSorin) test. Results: Median total vitamin D level was 19.9 ng/mL, IQR 11.2-28.8, with up to 3592 (27.4%) and 10185 out of 13110 (77.7%) respectively below 12 and 30 ng/mL. Vitamin D levels were significantly higher in women than men (20.5 vs 18.1 ng/mL; p<0.0005), in summer than in winter (21.4 vs 18.5 ng/mL; p<0.0005), and in the ≤45y or 46-64y than in the ≥65y subgroup (20.3 and 21.3 vs 18.8 ng/mL). Lowest vitamin D levels were displayed in winter by men aged ≥65y (14.7 ng/mL, IQR 8.1-23.1) and 46-64y (16.8 ng/mL, IQR 10.3-24.7). In comparison, women of the same age subgroups displayed considerably higher values (women aged ≥65y: median 18.2 ng/mL, IQR 8.7-27.9; women aged 46-64y: median 20.6 ng/mL, IQR 12.7-28.2). Multivariate analysis confirmed that age (p<0.0005), sex (p=0.002), season (p<0.0005) and their interaction (p=0.034) were independently associated to vitamin D concentrations. Conclusions: This study suggests that the majority of adult Italian population living in the North-Western Italy is at risk to develop serious bone diseases. However, these data must be interpreted with caution if considering the lack of standardization of vitamin D assays. 1 1 4 D. Vannoni , C. Corallo , G. Landi , A. Albanese , E. 4 1 3 2 Battisti , S. Giglioni , R. Leoncini , C. Scapellato 1 Dep.Internal Medicine, Endocrine-Metabolic Sciences and Biochemistry, University of Siena, Italy 2 U.O.C. Clinical Pathology, AOUS, Siena, Italy 3 U.O.S Standardizzazione e sviluppo in Biochimica Clinica, AOUS, Siena Italy 4 TAMMEF Centre, University of Siena, Italy Objectives: To compare human primary osteoarthritic chondrocytes submitted to electromagnetic fields (EMFs), which positively interfere with patients affected by OA, by a proteomic approach. Materials and methods: Osteoarthritic chondrocytes, isolated from the femoral heads of OA patients, were cultured in vitro and exposed 30 min/day for two weeks to extremely low frequency electromagnetic field (ELF) with fixed frequency (100Hz) and to therapeutic application of musically modulated electromagnetic field (TAMMEF) with variable frequencies, intensities and waveforms. Sham exposed (S.E) cells served as control group. Cell viability was measured at days 2, 7 and 14. After two weeks of treatments, a proteomic approach, using 2DElectrophoresis and mass spectrometry, was performed. Results: Cell viability was different in chondrocytes exposed to ELF and TAMMEF system compared to S.E. Proteome analysis showed different expression levels of proteins derived from nucleus, cytoplasm, and cell organelles, due to the treatments. Particularly, were identified proteins functionally related to energetic metabolism (glyceraldeyde-3-phosphate dehydrogenase), stress response (Mn-superoxide dismutase, heat shock proteins), cytoskeletal regulation (actin), proteinase inhibition (cystatin-B) and inflammation regulatory functions (S100-A10, S100-A11). Conclusions: EMFs do not cause damage to cultured chondrocytes, besides stimulate safely OA chondrocytes and are responsible of different protein expression in the three groups. Furthermore, protein analysis of OA chondrocytes treated with ELF and the new TAMMEF system could be useful to clarify the pathogenetic mechanisms of OA and to identify biomarkers of the disease. Battisti E, Piazza E, Rigato M, et al. Efficacy and safety of a musically modulated electromagnetic field (TAMMEF) in patients affected by knee osteoarthritis. Clin Exp Rheumatol 2004;22:568-72. biochimica clinica, 2012, vol. 36, n. 6 597 44° Congresso Nazionale SIBioC - Riassunti Poster P255 Aß OLIGOMERS: A NEW CSF BIOMARKER FOR THE DIAGNOSIS OF ALZHEIMER'S DISEASE 1 1 P256 CONSOLIDAMENTO DI CMV AVIDITY E MIGLIORAMENTO DEL TAT DURANTE LA GRAVIDANZA PRESSO L'AUSL MODENA 2 G.M. Sancesario , M. Nuccetelli , M.T. Cencioni , Z. 3 2 3 1 Esposito , G. Borsellino , G. Sancesario , S. Bernardini S. Tagliavini, D. Carra, M. Varani, P. Natali, A.M. Cenci 1 Corelab - Dipartimento Patologia Clinica - Nuovo Ospedale Civile San Agostino Estense - AUSL Modena Dept. of Experimental Medicine and Surgery, Univ. Tor Vergata, Rome 2 Lab. of Neuroimmunology, Santa Lucia Foundation, Rome 3 Dept of Systems Medicine, Univ. Tor Vergata, Rome Aß oligomers are soluble aggregates of a variable number of Aß monomers and constitute the precursors of insoluble large fibrils that deposit in amyloid plaques in the brain of Alzheimer’s disease (AD). The neurotoxic role of Aβ oligomers in vitro has stimulated an extensive search for their presence in the cerebrospinal fluid (CSF) of AD patients. In fact, whereas the insoluble fibrils deposit in brain tissue, soluble oligomers can diffuse into the CSF and, if detected in sensitive assays, they would constitute a useful biomarker for the amyloid pathogenic cascade. The aim of this study is to investigate whether measurement Aß oligomers in the CSF could be effective in the diagnosis of AD aside from Aß42 monomers, total tau (T-tau), and phosphorilated tau (P-tau). We analyzed 137 CSF using fluorescence resonance energy transfer (FRET) applied to flow cytometry. Levels of Aß oligomers are lower in the CSF of probable AD (n = 46) (P< 0.05) than in patients with other dementia (OD) (n = 35) or with other neurological disorders (OND) (n = 56). CSF of AD showed typical T-tau and P-tau increase (P<0.01) and Aß42 decrease (P<0.01) compared to OD or OND. In addition, the ratio Aß oligomers/P-tau was lower in AD than in OD (P<0.01) and OND (P<0.05) patients, (sensitivity 75%, specificity 64%), whereas the ratio of Aß oligomers/T-tau was significantly lower in AD compared to OND (P<0.01) (sensitivity of 78% and a specificity of 71%) but not to the OD group. Such values were comparable to sensitivity and specificity yielded by the other biomarkers alone or in combination. Our study demonstrates that the levels of Aß oligomers are lower in the CSF of probable AD than in control patients. Then, by analogy to monomeric, we could suggest that the oligomeric Aß in the CSF are decreased because aggregated Aß is deposited in plaques in the brain. Under our experimental setting, FRET analysis of the CSF Aß oligomers is as useful as the other biomarkers in the diagnosis of AD. Sancesario GM, Cencioni MT, Esposito Z, et al. The load of amyloid-ß oligomers is decreased in the cerebrospinal fluid of Alzheimer's disease patients. JAD 2012;31:865-78. Durante i primi mesi della gravidanza una recente infezione da CMV può causare danni al feto. Per tale motivo, in positività sia di IgG sia di IgM, è importante eseguire la determinazione dell’avidità delle IgG, la quale, crescendo con il tempo, aiuta a dirimere fra prima infezione e riacutizzazione. Presso il Corelab dell' AUSL di Modena alle pazienti positive per entrambe le classi Ig veniva tradizionalmente consigliata la determinazione dell’avidità CMV-IgG. La paziente si ripresentava mediamente con una nuova prescrizione dopo qualche giorno dalla prima determinazione ed il campione veniva avviato alla conferma presso un altro centro. Il TAT medio dalla prima determinazione era di due settimane e, per ridurlo, abbiamo studiato l’introduzione di un test sugli analizzatori in dotazione al laboratorio, in grado di determinare l’avidità in completa automazione entro la giornata. Il metodo adottato (Abbott CMV avidity su Architect) presenta un CV totale del controllo basso (media 28%) pari a 12% ed un CV del controllo alto (media 82%) pari ad 1.6%. Il metodo su Architect presenta una concordanza del 78% con il metodo precedente (DSX-Dynex, TechnoGenetics). La maggior parte dei casi discordanti (15%) riguarda campioni risultati greyzone con uno dei due metodi. Nello studio di correlazione il coefficiente di Pearson r=0.72 (C.I.95%=0.53-0.84) conferma che i risultati, pur essendo in generale accordo, non sono direttamente correlabili. Nel mese di settembre 2012 sono stati esaminati mediamente 26 +/- 6 campioni/ die, con una incidenza di positività IgM pari al (6+/-3)% . Di queste ultime, il 5.9% è risultata a bassa avidità. La tempestività delle risposte, tutte fornite in giornata, ha contribuito ad una più consona gestione clinica del paziente, licenziando velocemente il referto definitivo o avviando il campione ai necessari approfondimenti. Munro SC, Hall B, Whybin LR, et al. Diagnosis of and screening for cytomegalovirus infection in pregnant women. J Clin Microbiol 2005;43:4713-8. biochimica clinica, 2012, vol. 36, n. 6 599 44° Congresso Nazionale SIBioC - Riassunti Poster P257 DESCRIZIONE DEL PRIMO CASO DI ATASSIA CEREBELLARE ASSOCIATO AD ANTICORPI ANTI HU E GANGLIONEUROMA TORACICO 1 2 1 1 P258 DIAGNOSTIC POWER OF 24SHYDROXYCHOLESTEROL IN CEREBROSPINAL FLUID 1 2 3 4 E. Corsini , R. Fancellu , G. Del Mese , A. Mancano , S. 2 1 1 1 Salvarani , M. Lazzaroni , I. Gabrieletto , G. Bernardi V. Leoni , A. Solomon , L. Minthon , K. Blennow , M. 2 4 Kivipelto , I. Bjorkhem 1 1 UO Laboratorio Patologia Clinica e Genetica Medica, Fondazione IRCCS Istituto Neurologico C.Besta Milano 2 SC Neurologia, Ospedale Villa Scassi – ASL3, Genova Gli anticorpi anti-Hu sono autoanticorpi contro antigeni onconeurali associati a sindromi neurologiche paraneoplastiche. Sono diretti contro il nucleo delle cellule del SNC e dei gangli dorsali e l’antigene bersaglio è una proteina che lega l’RNA. L’immunofluorescenza indiretta è il test di screening e l’immunoblot test di conferma. Anticorpi anti-HU sono più frequentemente associati a tumore polmonare a piccole cellule in pazienti con neuropatie periferiche o degenerazione cerebellare ma sono stati descritti anche in altri tumori. Una donna di 27 anni manifestava dall’età di 19 una atassia progressiva; l’esame neurologico confermava la patologia cerebellare. Dall’età di 23 anni la risonanza magnetica mostrava un’atrofia cerebellare progressiva. I livelli plasmatici di analiti associati a patologia cerebellare erano normali, i test genetici erano negativi. Gli anticorpi anti Nucleo (ANA) erano positivi (1:320) così come gli anticorpi anti SSB (1+). Si riscontrava una positività anti nucleo neuronale in immunofluorescenza (1:640) confermata in immunoblot per antigeni HU ricombinanti, dimostrando la contemporanea presenza di ANA e anti cervelletto. Una Tac evidenziava una lesione espansiva nel mediastino sinistro. In seguito all’asportazione del tumore, l’esame istologico diagnosticava un Ganglioneuroma. Sezioni istologiche di tumore della paziente testate in immunoistochimica con il siero della stessa, risultavano debolmente positive. Dopo l’intervento, il titolo anticorpale scendeva a 1:160 dopo 4 mesi ed a 1:80 dopo 8 e 10 mesi. La sintomatologia cerebellare peggiorava leggermente dopo l’intervento per poi stabilizzarsi. Questo è il primo caso finora descritto di associazione di anticorpi anti Hu e ganglioneuroma, un tumore benigno del gruppo dei tumori neuroblastici. Tra questi, il neuroblastoma è stato associato a opsoclono-mioclono-atassia, assente nella nostra paziente. La mancanza di caratteristiche istologiche distintive potrebbe spiegare l’associazione di questo tumore benigno con anticorpi anti-Hu e un’atassia cerebellare che si è presentata con lento decorso, simulando una forma degenerativa progressiva. McKeon A, Pittock SJ. Paraneoplastic encephalomyelopathies: pathology and mechanisms. Acta Neuropathol 2011;122:381-400. 600 biochimica clinica, 2012, vol. 36, n. 6 Laboratory of Clinical Pathology and Medical Genetics, AmadeoLab R17, Foundation IRCCS Institute of Neurology “Carlo Besta”, Milano, Italy 2 Aging Research Center, Karolinska Institutet, Huddinge, Sweden 3 Clinical Memory Research Unit, Department of Clinical Sciences, Lund University, Malmö, Sweden 4 Department of Psychiatry and Neurochemistry, Institute of Neuroscience and Physiology, The Sahlgrenska Academy, University of Gothenburg, Mölndal, Sweden Previously we reported that 67% of patients with Alzheimer´s disease (AD) and 50% of patients with mild cognitive impairment (MCI) had increased levels of the oxysterol 24S-hydroxycholesterol (24OH) in cerebrospinal fluid (CSF). In the same populations an ADlike biomarkers pattern (increased Tau, P-tau and reduced #-Amyloid (Ab42)) were found at similar frequency (AD) or lower frequency (MCI). In the present work we investigated 5 groups of patients at our memory clinic: healthy volunteers who did not later develop cognitive problems (n=26), subjects with subjective cognitive impairment (n=33), patients with MCI (n=27), patients with MCI with a later progression into AD at follow up (n=10) and patients with AD (n=24). We calculated the fraction of positive or negative tests for each subgroup of patients with use of previously published cut-off levels for 24OH, Tau, P-tau and A#42. The fraction of the population with pathological levels of 24OH was 4% in the controls, 34% in SCI, 37% in MCI stable, 80% in MCI progressive and 42% in AD. The corresponding figures for Tau, P-tau and A#42 were lower in the case of SCI and MCI stable but higher in the case of controls and AD. In case of MCI progressive the fraction of pathological levels of 24OH and Ab42 were the highest, 80% and 63% respectively. The diagnostic power of 24OH in CSF seems to be similar to or lower than that of the established biomarkers Tau, P-tau and A#42 in the diagnosis of established AD. The lower frequency of pathological levels of 24OH in CSF in patients with established AD may be due to a reduced number of dying neuronal cells releasing the oxysterol at a late stage of the disease. The high proportion of pathological levels of 24OH in SCI and stable MCI is of interest and suggest that 24OH may be more sensitive than the classical biomarkers in an early phase of the neurodegenerative process. Leoni V, Caccia C. Oxysterols as biomarkers in neurodegenerative diseases. Chem Phys Lipids 2011;164:515-24. 44° Congresso Nazionale SIBioC - Riassunti Poster P261 IL DOSAGGIO DEI MARCATORI TUMORALI SU LIQUOR CON ARCHITECT PLUS ABBOTT P262 INFORMATIZZAZIONE DI LABORATORIO DEL RISCHIO NEFROLITIASICO M. Lazzaroni, E. Corsini, S. Diciocia, A. Porini, G. Bernardi G. Cangiano , A. Latte , E. Di Maina , G. Buccino , C. 1 1 1 Taranto , A. Garofalo , M.M. D'Ambrosio , M. 3 1 D'Amora , A. Sarappa U.O. Patologia Clinica e Genetica Medica, Istituto Neurologico "C. Besta", Milano 1 2 1 1 1 Il dosaggio dei marcatori tumorali su liquor è importante nella diagnosi e nel monitoraggio di tumori primitivi o metastatici del sistema nervoso centrale. Le carcinomatosi meningee sono particolarmente frequenti ed in costante aumento: i referti autoptici documentano oggi carcinomatosi meningee nel 5-8% dei casi di tumore esaminati. L’esame citologico è l’esame di elezione, con limitazioni date dall’estrema fragilità delle cellule tumorali liquorali e dalla necessità di personale qualificato. Recentemente sono comparse in letteratura diverse proposte per la ricerca di marcatori tumorali su liquor. In caso di carcinomatosi meningee si trovano nel liquor concentrazioni elevate di CEA e dei marcatori mucinici Ca19.9 Ca125 Ca15.3; alfa-fetoproteina e beta-HCG si elevano in presenza di tumori germinali cerebrali. Abbiamo utilizzato l’analizzatore automatico Architect Plus Abbott per valutarne un possibile utilizzo clinico nel dosaggio dei marcatori tumorali su liquor. Per prima cosa abbiamo verificato l’assenza di segnale di fondo utilizzando 20 liquor di soggetti sicuramente non affetti da patologia tumorale: i risultati hanno documentato assenza di effetto matrice e dosaggi inferiori al limite della sensibilità dei metodi. Abbiamo testato replicati di diluizioni seriate per verificare la linearità alle basse concentrazioni e abbiamo inoltre verificato la ripetibilità intra e interserie. I risultati ottenuti mostrano un’ottima sensibilità e permettono di fare il dosaggio nei marcatori nella pratica clinica come documentato dalla concordanza dei risultati ottenuti su 10 campioni di pazienti con diagnosi certa. I risultati vanno obbligatoriamente espressi come presenza o assenza di sintesi intratecale, con quantificazione della frazione intratecale, particolarmente utile nel monitoraggio della terapia cui vengono sottoposti i pazienti. Corsini E, Bernardi G, Gaviani P, et al. Intrathecal synthesis of tumor markers is a highly sensitive test in the diagnosis of leptomeningeal metastasis from solid cancers. Clin Chem Lab Med 2009;47:874–9. Kim A, Ji L, Balmaceda C, et al. The prognostic value of tumor markers in newly diagnosed patients with primary central nervous system germ cell tumors. Pediatr Blood Cancer 2008;51:768–73. 602 biochimica clinica, 2012, vol. 36, n. 6 U.O. Lab. di Patologia Clinica, Osp. dei Pellegrini, ASL NA 1 Centro Napoli 2 Lab. Patologia Clinica ed Ematologia, Azienda Ospedaliera apss Trento 3 Direzione Generale, ASL NA 3 Sud Lo screening metabolico urinario effettuato su pazienti a rischio nefrolitiasico necessita di raccolte delle 24 ore (in acido cloridrico e clorexidina) ma anche di dosaggi praticati su urine estemporanee. L’informatizzazione presente nel nostro Laboratorio ed i relativi collegamenti con le strumentazioni biochimiche in uso risultano abbastanza problematici per tali specifici campioni così come l’archiviazione, le ricerche e principalmente la stampa del referto finale. Per tali motivazioni ma anche per calcolare ed ottenere un foglio finale indicante le componenti quali/quantitative di un calcolo renale (dosati con metodi completamente strumentali) si è creato un programma in Access di facile gestione. Il data base è costituito da una serie di tabelle (esami, paziente, reparti, ecc.) facilmente accessibili grazie alla costruzione di maschere e da diversi report, scaturiti da opportune relazioni (query) utili alla stampa finale del referto. L’utilizzo di piccoli programmi (macro) all’interno dello stesso data base rendono più semplici le ricerche e la immissione dei dati urinari (dosati su comuni analizzatori biochimici), delle supersaturazioni, la ricerca di pazienti, l’inserimento di esami non routinari, di grafici bitmap, ecc. L’utilizzo di relazioni tra più tabelle concorreranno alla estrapolazione dei campi anagrafici e di quelli laboratoristici, questi ultimi opportunamente elaborati, utili alla creazione del referto finale. Il grafico di supersaturazione viene opportunamente ritagliato ed inserito all’interno della maschera esami sotto forma di immagine bitmap collegata. Rispetto al sistema informatico presente nel nostro Laboratorio il programma in Access da noi proposto evidenzia in un unico foglio di stampa il rischio nefrolitiasico in modo evidente, conciso e di facile interpretazione. Notevole appare la possibilità di referto “diretto”, compresa l’immagine, del calcolo urinario. L’utilizzo della nostra applicazione ridurrà notevolmente i tempi di risposta quando sarà in grado di estrapolare anche il grafico di supersaturazione e di interfacciarsi con gli analizzatori biochimici. Cangiano G, Russo M, Forte F, et al. Diagnostica di laboratorio della calcolosi urinaria. Biologi Italiani 2008;8:40-7. 44° Congresso Nazionale SIBioC - Riassunti Poster P263 L’ELF-TEST (SIEMENS): L’IMPORTANZA DELLA VALIDAZIONE CLINICA IN UN LABORATORIO OSPEDALIERO “DI PROVINCIA” 1 1 1 1 V. De Rienzo , M. Fumi , Y. Pancione , V. Piscopo , S. 1 2 2 2 1 Sale , S. Alessio , M. Talamo , A.S. Megna , V. Rocco 1 UOC Patologia Clinica, A.O.R.N. “G. Rummo” di Benevento 2 Malattie Infettive, A.O.R.N. “G. Rummo” di Benevento La stadiazione della fibrosi epatica è fondamentale per la prognosi e l’orientamento terapeutico: lo sviluppo di metodi non invasivi, quali biomarkers sierici ed elastografia transiente, rappresenta un progresso in epatologia. I marcatori sierici possono essere raggruppati in due categorie: ”diretti” per la presenza in circolo di peptidi coinvolti in fibrinogenesi, fibrinolisi o flogosi e “indiretti” costituiti da una miscela di alterazioni biochimiche e parametri clinici riscontrati nelle CLDs. La capacità predittiva di molteplici combinazioni di questi marcatori è incrementata dalla loro inclusione in un algoritmo matematico. Scopo del lavoro è stato testare l’utilità diagnostica del test ELF (Enhanched Liver Fibrosis), soprattutto nella individuazione dei casi di fibrosi limitata. Metodologia: L’ELF combina 3 marcatori sierici diretti: Ac. Ialuronico, Propeptide amino-terminale del procollagene di tipo III e Inibitore Tissutale della Metalloproteinasi I. Lo studio è stato condotto su 3 gruppi di pazienti: 31 donatori sani, 48 soggetti afferiti al servizio di epatologia per vaghi disturbi digestivi e/o persistente o intermittente incremento delle transaminasi e 51 soggetti con grave epatopatia accertata mediante biopsia. Risultati: Tra i donatori, 26 soggetti presentavano ELF-t <7.7 (assenza di fibrosi), nei restanti 5 l’ELFt >7.7 (range 7.91-8.55) orientava per presenza di moderata fibrosi epatica. In questi, con FIBROTEST ed HEPASCORE negativi, ulteriori indagini (marcatori indiretti, BMI) evidenziavano: in 1 aumento della GGT, in 3 aumento dell’ BMI (>25), in 1 assenza di altre alterazioni. Nel II gruppo di pazienti, 28 presentavano valori di ELF test <7.7, 15 (HCV positivi) mostravano 7.7<ELF-t<9.8 mentre i restanti 5 presentavano ELF-t >9.8. Infine il III gruppo, costituito da soggetti con grave epatopatia, presentava ELF-t >9.8. Conclusioni: I risultati ottenuti dimostrano l’efficacia dell’ELF test nella individuazione dei casi di severa fibrosi, ma, sorprendentemente, la possibilità di identificare casi di sospetta lieve fibrosi in soggetti teoricamente sani (donatori) e di stratificare quelli che richiedono conferma bioptica dell’ELF test. Pinzani M. The ELF panel: a new crystal ball in hepatology? Gut 2010;59:1165-7. P264 L’USO DI ALCUNI ALGORITMI DIAGNOSTICI E LA PRESA IN CARICO DEL RISULTATO PATOLOGICO NELLE EPATITI VIRALI E. Tili, G. Forconi, C. Martini, S. Secondini, P. Pauri U.O. Patologia Clinica Jesi, Area Vasta 2 - ASUR Marche Scopo: L’uso di algoritmi diagnostici è una risorsa per il miglioramento dell’appropriatezza della richiesta e per dare maggior valore alle professioni che operano all'interno dei laboratori. Materiali e metodi: Nella nostra realtà abbiamo introdotto nel tempo alcuni algoritmi, anche allo scopo di migliorare la gestione delle risorse sanitarie. In particolare, per epatite B, in accordo con specialisti ospedalieri e MMG, in caso di positività per HBsAg, effettuiamo a cascata tutti i marker di epatite e HBV DNA. Per gli operatori sanitari nati dopo il 1991 abbiamo introdotto in prima battuta la ricerca di anticorpi anti-HBs e, solo se negativi, la ricerca di HBsAg e anti-HBc. Per HCV, l’espressione dei risultati come sample/cutoff (S/CO) permette di costruire algoritmi di conferma, in base alla storia clinica ed all’età, evitando sprechi per test di conferma. Nel caso di soggetti con sospetta epatite acuta, per evitare il ricorso a test multipli contemporanei per epatite A, B o C, suggeriamo in mancanza di fattori di rischio solo la ricerca di IgM antiHAV, HBsAg, anti-HBc IgG (eventualmente IgM). Per il follow-up delle epatiti croniche HBV o HCV controlliamo la cadenza di richiesta dei test molecolari per la scelta e la valutazione dell’efficacia della terapia (HBV DNA, HCV RNA e HCV genotipo), lavorando in un’ottica di presa in carico integrata fra Territorio e Ospedale, in cui il laboratorio svolge un ruolo centrale. Risultati: Dal database del laboratorio abbiamo estratto i dati relativi alle richieste dei marcatori delle epatiti virali giunte nell’anno 2011 e primo semestre 2012. A fronte di 6851 HBsAg, i test di approfondimento (anti-HBc IgM, HbeAg, anti-HBeAg) sono stati effettuati solo in 250 casi; sono stati effettuati 1910 anti-HBs. Il 4,6% dei pazienti è positivo per anti HCV e di questi il 30% supera i 65 anni di età, non sottoposti quindi alla ricerca di HCV RNA in quanto non eleggibili per terapia antivirale. Discussione: L’analisi dei dati raccolti dimostrano l’efficacia degli algoritmi diagnostici, accompagnati dalla presa in carico del paziente, sulla strada del miglioramento continuo dell’appropriatezza della richiesta. biochimica clinica, 2012, vol. 36, n. 6 603 44° Congresso Nazionale SIBioC - Riassunti Poster P266 STUDIO DELLE BANDE OLIGOCLONALI IgG LIQUORALI IN UN GRUPPO DI PAZIENTI HIV POSITIVI P265 SERUM CONCENTRATION DEFICIENCY OF 25OH VITAMIN D IN PATIENTS WITH MYOTONIC DYSTROPHY TYPE 1 1 2 2 2 M. Morello , C. Terracciano , E. Rastelli , R. Massa , S. 1 2 Bernardini , R. Zenobi Lab. Analisi Chimico Cliniche A.O. S. Gerardo di Monza 1 Department of Experimental Medicine and Surgery, Faculty of Medicine, University of Rome Tor Vergata 2 Department of Neurosciences, Faculty of Medicine, University of Rome Tor Vergata Introduction: Myotonic Dystrophy type 1 (DM1) is the most common form of adult onset muscular dystrophy. DM1 is a multisystemic disorder involving skeletal muscle, as well as heart, eye, endocrine and central nervous systems. Distal muscle weakness and myotonia are the prevalent muscular symptoms. Vitamin D is a regulatory molecule involved in calcium homeostasis, endocrine and immune systems. In addition, vitamin D seems to influence muscle metabolism through stimulation of IGF1 axis. Vitamin D deficiency is a recognized pathological condition characterized by muscle weakness, rickets or osteomalacia. Objective and methods: To assess whether vitamin D might contribute to DM1 severity, serum levels of vitamin D (25-OH vitamin D), parathyroid hormone (PTH) and IGF1 were measured. Sixty-one subjects were enrolled in this study: 31 patients with adult-onset DM1 (16 premenopausal women and 15 men, mean age 41.6 years) and 30 age-matched normal controls. Results: In DM1 patients vitamin D showed a 55% reduction compared to controls (p<0.01), with a mean value of 16.3 ng/mL, indicative of vitamin D deficiency. PTH levels were normal in both groups, while IGF 1 was slight decrease (p<0.05) in DM1 compared to control patients. Inflammatory parameters (Interleukin-6, TNF-α and C-reactive protein) were also assayed and did not show any differences compared to controls. In DM1 patients, Vitamin D reduction is statistically correlated to cholesterol levels (total and LDL: r = -0.44 and r =-0.37 respectively p<0.05), while no correlations were found between Vitamin D and other biochemical parameters. Discussion: The IGF 1 low levels might explain some of symptoms of DM1 patients and also the decrease of vitamin D due to IGF 1 action on the epithelial cells; further, the lack of correlation between vitamin D and PTH show that in these patients the vitamin D concentrations don’t alter the PTH release. Whether 25-OH vitamin D reduction in DM1 is due to an impairment of UV skin synthesis or a defective hepatic hydroxylation need to be investigated. 604 R. Brivio, L. Pirovano, D. Corti, L. Carati, V. Minolfi, N. Spinoni biochimica clinica, 2012, vol. 36, n. 6 Introduzione: Molteplici studi evidenziano che il Virus dell’Immunodeficienza Umana (HIV) mostra un peculiare neurotropismo e infetta molto precocemente il Sistema Nervoso Centrale (SNC). I sintomi possono essere transitori nel periodo della sieroconversione o interessare sia il SNC che il Sistema Nervoso Periferico nelle fasi avanzate della malattia. Uno studio evidenzia che più dell’80% dei pazienti neurologicamente asintomatici ha mostrato anomalie nel Liquido Cefalo Rachidiano quali: leggera pleiocitosi (di cellule mononucleate), aumentata concentrazione di IgG liquorali, aumento dell’indice di Link, normale indice di funzionalità della Barriera Emato Encefalica (BEE) e nel 50% dei casi presenza nel liquor di Bande Oligoclonali IgG (BO) assenti nel siero. Scopo: Analizzare retrospettivamente i reperti liquorali rilevati in pazienti HIV positivi afferenti all’A.O. S. Gerardo di Monza negli anni 1995-2011. Metodi: Ricerca BO in isoelettrofocalizzazione con rivelazione immunologica specifica (Medical System); dosaggio di Albumina e IgG plasmatiche e liquorali con metodo immunonefelometrico (APS, Beckman); calcolo dell’indice di Link e di funzionalità di BEE. Risultati: Sono stati analizzati i campioni sierici e liquorali di 54 pazienti (F=8 età media 41 anni e M=46 età media 42 anni); 33 pazienti (61% F=7 e M=26) sono risultati positivi per presenza di BO liquorali, in 2 casi era contemporaneamente presente un’infezione luetica. L’indice di Link è risultato sopra i limiti di riferimento (>0.85) in 16 pazienti con BO liquorali presenti, più alto, ma non significativamente, rispetto ai pazienti con BO assenti (mediana 0.84 vs 0.61). L’indice di funzionalità di BEE medio è risultato sovrapponibile nei due gruppi (8.48 vs 8.43). Conclusioni: L’elevata percentuale di BO nei pazienti HIV positivi, confermata anche nel nostro studio, suggerisce l’opportunità di indagare l’eventuale infezione da HIV in pazienti con sintomi neurologici altrimenti inspiegabili. Sebbene non sia completamente chiara la patogenesi delle BO in tali circostanze, pur considerando l’invasività della rachicentesi e la complessità analitica, la loro ricerca potrebbe fornire un utile compendio in questi pazienti. 44° Congresso Nazionale SIBioC - Riassunti Poster P267 UTILIZZO DI UN SISTEMA ESPERTO NELL’ ANALISI DEL SEDIMENTO URINARIO V. Sbolci, D. Borgi, D. De Ninno, R. Palumbo, G. Salerno, F. Veroni, S. Rapi, A. Ognibene Dipartimento di Diagnostica di Laboratorio, Laboratorio Generale, Azienda Ospedaliero-Universitaria Careggi, Firenze L’introduzione, nei laboratori clinici, di nuove tecniche automatizzate per la lettura del sedimento urinario, tra cui la microscopia a flusso con digitalizzazione ed analisi delle immagini tramite reti neurali (iQ 200 IL), ha contribuito a migliorare la standardizzazione dell’analisi microscopica urinaria. Tale tecnica, seppur affidabile, richiede ancora una valutazione manuale per verificare e, se necessario correggere, i risultati mediante analisi microscopica. L’utilizzo di sistemi esperti (SE) in grado di combinare parametri chimici e morfologici, può offrire un aiuto interessante in termini di risparmio di tempo e di riduzione dei campioni da verificare, senza inficiare la correttezza del dato. Lo strumento di analisi iQ200 è stato integrato con un SE (i-WARE, IL) che utilizza inferenze logiche in grado di comparare i parametri chimici e fisici del campione urinario. Il rispetto o meno delle condizioni dettate dalle regole impostate, permette di selezionare più accuratamente i campioni da sottoporre a verifica di II livello mediante microscopia ottica. Il SE è stato applicato alla validazione di 16264 campioni urinari, giunti in laboratorio nel periodo 1 aprile-30 giugno 2012 ed è stato valutato per solo sette delle regole impostate: Hb≥0.06 e RBC<20/uL, esterasi ≥75 mg/dL e WBC<20/uL, esterasi ≤25 mg/dL e WBC>20/uL, nitriti≥+1 e WBC<20/uL, nitriti >0 e batteri presenti e EPD>10000/ uL, nitriti≥+1 e batteri assenti e EPD≤ 10000/uL, proteine> 5 mg/dL e Hb≥0.06 mg/dL e RBC> 10/uL e età≤12 anni, esterni e proteine≥30 mg/dL. Il 69.8% dei risultati non hanno superato il filtro delle regole ed è stato verificato manualmente sul sistema iQ200 dall’operatore, il restante 30.2% è passato automaticamente alla validazione tecnica e clinica permettendo all’operatore di dedicarsi più tranquillamente ai campioni fermati in griglia. L’elevata percentuale di campioni bloccati dal S.E. risente verosimilmente di variabili preanalitiche (raccolta e conservazione del campione) e, in maniera minore, strumentali. Sebbene debba essere sottoposto ad ulteriori indagini ed implementazioni, il sistema i-Ware può velocizzare il flusso di lavoro quotidiano, permettendo una refertazione più rapida ed affidabile, con indubbi vantaggi diagnostici. biochimica clinica, 2012, vol. 36, n. 6 605