bcfeil - Leonardo luce

Transcript

bcfeil - Leonardo luce
BCFEIL
Gennaio 2013
EEI=A3
Articolo
Article
Codice
Code
S/BCFEIL/14
220÷240
0,05÷0,12
50÷60
6÷14
14,7
> 0,6c
-10÷50
80
22x144,5x22
50
S/BCFEIL/14
S/BCFEIL/21
220÷240
0,12÷0,20
50÷60
16÷21
23
> 0,6c
-10÷50
80
22x144,5x22
50
S/BCFEIL/21
S/BCFEIL/24
220÷240
0,12÷0,21
50÷60
18÷26
24,8
> 0,6c
-10÷50
80
22x144,5x22
50
S/BCFEIL/24
Lampade - Lamps - Lampes - Lampen
High frequency electronic ballast for fluorescent lamps.
- Equipped with push-in terminals.
- Max length lamp cables cm 100.
- Cathodes pre-heating, suitable for frequent lighting.
- 25% energy saving compared to conventional ballasts. No flickering.
- 120 V Ac versions available on demand.
Protections:
lamp disconnection, cathodes breaking, lamp end of life and rectifying effect.
Standard reference:
Safety: EN 61347-1; EN 61347-2-3
Radio Interferencies: EN 55015; EN 55015-A1; EN 55015-A2
Harmonics: EN 61000-3-2
Immunity: EN 61547.
Performance: EN 60929.
Ballast électronique à haute fréquence pour lampes fluorescentes.
- Avec bornes à connexion rapide pour les cables d’alimentation.
- Longueur max câbles lampe 100 cm.
- Allumage avec préchauffe des cathodes indiqué pour des allumages fréquents.
- Économie d’énergie de 25% par rapport aux ballasts conventionnels.
- Absence de l’effet stroboscopique.
- Versions à 120V ca disponibles sur demande.
Protections:
lampe débranchée, cathodes coupées, fin de vie de la lampe et effet rectifiant.
Normes de renvoi:
Sécurité: EN 61347-1; EN 61347-2-3
Perturbations radioélectriques: EN 55015
Courants harmoniques: EN 61000-3-2
Immunité: EN 61547.
Prestations: EN 60929.
S/BCFEIL/14
TYPE
T5
T5
T5
T5
TC-DEL
TC-DEL
TC-TEL
TC-SEL
TC-SEL
TC-SEL
T2
T2
T2
T2
TC-DDE
OSRAM
FH
L
L
L
DULUX D/E
DULUX D/E
DULUX T/E
DULUX S/E
DULUX S/E
DULUX S/E
FM
FM
FM
FM
-
TYPE
T5
TC-DEL
TC-TEL
TC-DDE
OSRAM
FH
DULUX D/E
DULUX T/E
-
TYPE
T5
TC-L
TC-L
TC-F
TC-F
T8
TC-DEL
TC-TEL
T5C
TR
TC-DDE
OSRAM
FQ
DULUX L
DULUX L
DULUX F
DULUX F
L
DULUX D/E
DULUX T/E
FC
L..C
-
PHILIPS
TL5 HE
TL
TL
TL
PL-C/4p
PL-C/4p
PL-T/4p
PL-S/4p
PL-S/4p
PL-S/4p
-
W
14
6
8
13
10
13
13
7
9
11
6
8
11
13
10
SOCKET
G5
G5
G5
G5
G24q1
G24q1
Gx24q1
2G7
2G7
2G7
W4,3
W4,3
W4,3
W4,3
Gr10q
W
21
18
18
16
SOCKET
G5
G24q2
Gx24q2
Gr10q
W
24
18
24
18
24
18
26
26
22
22
21
SOCKET
G5
2G11
2G11
2G10
2G10
G13
G24q3
Gx24q3
2Gx13
G10q
Gr10q
S/BCFEIL/21
PHILIPS
TL5 HE
PL-C/4p
PL-T/4p
S/BCFEIL/24
PHILIPS
TL5 HO
PL-L
PL-L
TD-L
PL-C/4p
PL-T/4p
TL5C
TL-E
-
Dimensioni (mm) - Dimensions (mm) - Dimensions (mm) - Maße (mm)
22
Ballast elettronico ad alta frequenza per lampade fluorescenti.
- Con morsetti ad innesto rapido per cavi di collegamento.
- Lunghezza max cavi lampada cm 100.
- Accensione con preriscaldo dei catodi adatto per accensioni frequenti.
- Risparmio di energia del 25% rispetto ai ballast convenzionali. Assenza dell’effetto
stroboscopico.
- Disponibile a richiesta versioni a 120 V Ac.
Protezioni:
lampada scollegata, catodi interrotti, fine vita lampada e effetto rettificante.
Norme di riferimento:
Sicurezza: EN 61347-1; EN 61347-2-3
Radio disturbi: EN 55015; EN 55015-A1; EN 55015-A2
Armoniche: EN 61000-3-2
Immunità: EN 61547.
Prestazioni: EN 60929.
144.5
22
134
Elektronisches Hochfrequenz-Vorschaltgerät für Leuchtstofflampen.
- Mit Schnellsteckklemmen für Anschlusskabel.
- Max. Länge der Lampenkabel 100 cm.
- Vorheizen der Kathoden, geeignet für häufiges Einschalten.
- Energieeinsparung von 25% gegenüber den herkömmlichen Vorschaltgeräten.
- Kein Flimmern.
- Auf Anfrage als 120 V Wechselstrom-Ausführung erhältlich.
Schutz:
Ausfall der Lampe, Kathodenbruch, Ende der Lebensdauer der Lampe und Gleichrichtereffekt.
Bezugsnormen:
Sicherheit: EN 61347-1; EN 61347-2-3
Funkstörungen: EN 55015
Oberschwingungen: EN 61000-3-2
Störfestigkeit: EN 61547
Arbeitsweise: EN 60929.
Via delle Azalee, 6/A
20090 Buccinasco (MI) - Italy
Tel. 02488616.1 - Fax 0245712270
mail: [email protected] - www.relco.it