SYSTEM DESCRIPTION
1-SYSTEM OVERVIEW AND SERVICE
The HO-SY System handles every kind of service in the hotel.
The different graphic representations the software handles, are adapted to the client needs according to their use,
and they are divided in three different sectors:
HOTEL
HOSPITAL
HOME
The following description is related to the HOTEL sector.
---------------------------------------------------------------------------------------------------------------------HO-SY can be subdivided into two practically identical systems that differ only for the selected access typology in the
rooms
-ELECTRONIC CARD ACCESS
The electric door lock is activated through a chip-card type.
Special devices in the room will allow to:
-activate the electric services and the air-conditioning system
-signal the guest’s presence or the service staff presence (also specifying their personal particulars)
-ELECTRICAL KEY ACCESS
The panel key at the reception is equipped with special devices signalling to the handling PC the key removal from the
panel.
With this action the PC activates the electric services and the air conditioning in the room.
The staff presence in the room (anonymous personal particulars)is signalled through a special control panel with the
insertion of an apposite service electrical key. This typology has a variation (called Key panel LED) which is a
particularly useful in the structures where the Check-in and Check-out operations must be very quick, free from the
guest’s data immediate entry.
The HO-SY services are explained with the following graph:
TECHNA srl Genova
-General Set-up
-Ready rooms detection
-Cleaning handling
-Air conditioning system
handling
-Temperature display
-Alarms handlings
-Fire-fighting system handling
-Mini-bar handling
-Pay-TV handling
-Safe handling
-Staff positioning in the rooms
-Electronic money
-Internal POS handling
-Video messages
-Accesses authorization
-Check-in
-Check-out
-Police form printing
-Invoice printing
-Guest files
-Rooms moving
-Eportable database
RECEPTION
-Accesses control
-Air-conditioning handling
-Rooms temperature testing
-Power use handling
-Controls and checks on electrical panels
-Controls and checks on equipments
-Electronic money
-Fire-fighting system handling
COMMON
AREAS
SIGNALS
ROOMS
-Staff call
-Staff presence
-Guest presence
-Ready room
-Do not disturb
-Open window
-Front door state
-Mini-Bar use
-Fan coil state
-Fan coil valve state
-Sanitary fixtures water valve
state
-Bathroom radiator valve state
-Power presence
-Room temperature
-Pay-Tv use
-Pay-Tv tampering
-Video message
-Water use telemetry
-Power use telemetry
CONTROLS
-Fan coil valve
-Sanitary fixture water
valve
-Bathroom radiator valve
-Fan coil speed
-Pay-Tv lockup
-Mini-bar lockup
-Safe lockup
-Power lockup
-Courtesy light
-Door opening with coded
electronic support
ALARMS
-Fire
-Bathroom
-Flood
-Intrusion
2
TECHNA srl Genova
HO-SY was realized with the method of distributed intelligence, that is the central PC informs and receives data from
a series of peripheral units equipped with a microprocessor.
This solution allows, in case of PC breakage, or in case of connection BUS breakage, the local running continuation
according to the last data received from PC.
The communication among the different units and the central PC occurs though Polling, the PC calls sequentially all
the units and waits for their answer. HO-SY system consists of 4 units:
1-Central unit of Handing
2-Handing peripheral unit and data interface
3-Data transmission BUS
4-Room equipment
1-HANDLING CENTRAL UNIT(UCG)
It is composed by a Personal Computer, complete with monitor, keyboard and mouse, a handling software and one or
more RS485 interfaces. The unit is complete with modem and teleassistance software.
2-HANDSHAKING PERIPHERAL UNIT
This unit supervises the peripheral and UCG information exchange.
Fig.2
Handshaking peripheral unit-box DIN 9 modules
The microprocessor installed on the edge, according to the installed firmware, makes the following functions
execution:
3
TECHNA srl Genova
A-Chip card reading and writing handling
It writes and reads the authorization codes on the Chip cards. It usually placed at the reception.
B-Rooms services handling (RCU)
This unit controls (through a suitable driver card ) the rooms (maximum 4) connected to it at the same time.
C-Common areas services handling (ACU)
This unit can be supported by the following interface boards installed on a DIN rack with 9 modules, according to the
service you’d like to get:
UNIT NAME
FUNCTION
-I/O (I/O unit)
Controls and signals (I/O) for lights, motors, etc, activation, and systems state
control.
-Fire prevention unit (FIRE unit)
This unit handles 4 independent zones. It controls every zone sensors (with test),
the safe crash alarm bottoms, it carries out the fire-stop doors and sirens
controls.
When the fire prevention detection is used, each BUS RS485 in output from the
handling PC is provided with an additional unit, to make a continual control on
the PC operation data network.
-Air conditioning unit (HVAC unit)
The interface controls the conditioning of 4 independent zones ( it controls the
temperature and activates the Fan-Coil).
-Access unit (Access unit)
Doors opening authorization of 4 independent zones with two OUT controls
everyone dedicated to door look and
lights.
-Power control unit (PWR unit)
All the electrical equipments are entered with major power use and their
working priority are entered in a database. According to this table, UCG
disactivates the equipments with less priority when their consumption is closer
to the power maximum contractually available at a normal rate.
This board handles up to 16 equipments.
ON-line charge on room/client account for the hotel services.
-Electronic money unit ( POS
It is composed by:
unit)
-keypad for client PIN code typing
-Chip-Card reader for client recognition and PIN code identification
-Operator keypad and alphanumeric display
3-DATA BUS
It is a shielded pair connecting sequentially or radically all the peripheral units with UCG. The BUS connects up to 32
handshaking units to a 800 ml. distance.
When the length or the units number increase, a LINE EXTENDER will be used.
On a unique PC you can connect up to 32 independent BUS
4-ROOM SYSTEM
All the equipments set necessary to the data testing and to the controls execution in the room. It consists of:
a)-ROOM CONTROL
It is composed by two module units:
-I/O board for data exchange (DIN rack with 6 modules )
-Electrical controls board (DIN rack with 4 modules)
4
TECHNA srl Genova
Fig. 3
Racks for ROOM CONTROL unit
The ROOM CONTROL makes the following functions:
CONTROLS REALIZATION
(from PC or locals)
1-Power ON/OFF
2-Courtesy light
3-Electrical lock opening
4-Fan-Coil speed
(0-1-2-3)
5-Fan-Coil solenoid valve
6-toilet napkins heater solenoid
7-Water sanitary fixtures solenoid
8-Pay –TV lock up
9-Pizoelectric bell
10-Safe lock up
11-Minibar lock up
12-Zone pump control
ALARMS
GENERAL PC SIGNALLING
1-Power presence
2-Pay-TV state
3-Pay-TV tampering
4- Minibar opening
5-Safe opening
6-Toilet napkins heater solenoid
state
7-Water sanitary fixtures
solenoid state
8-Fan-Coil solenoid state
9-Front door state
LINKED FUNCTIONS
1-Water solenoid closing with
1-Bathroom
active alarm flood prevention
2-Flood
2-Fire prevention sensor reset
3-Open window (during the client 3-Air conditioning lock-up with
open window
absence)
4-Intrusion prevention
5-Fire prevention
b)-External Chip-Card reader
Unit installed on a embedded 3U rack frame. Polycarbonate covering. It
supports every civil series plates.
LED SIGNALLINGS
CONTROLS
1-Lock opening with Chip-Card codes reading 1-Chip-Card code identification
2-General alarm
2-Doorway courtesy light
3-Do not disturb
3-Bell button
4-Minibar state
5-Client’s presence in the room
LINKED FUNCTIONS
1-Bell working lock-up with do not disturb
on
2-Chamber maid access stopping with client
in the room
3-PC signal of the last Chip-Card code input
5
TECHNA srl Genova
c)-Chip-Card reader within the room
Unit installed on an embedded 3U rack frame. Polycarbonate covering.
It supports every civil series plates.
CONTROLS
1-Exit courtesy light
2-Service button “Ready Room”
3-“DO NOT DISTURB” button
4-Power activation on chip cards
authorized
LED SIGNALLINGS
1-Undelivered messages
2-Cleaning- up/ready room
3-“DO NOT DISTURB” state
LINKED FUNCTIONS
1-PC signal of the presently inserted chipcard
2-Last chambermaid’s code PC signal
3-PC signal of the clean-up condition
d)-Bedhead
Unit installed on an embedded 4U rack frame.
This unit works jointly with a board (9 modules DIN) for B.T.
control of the room light points (5 Vcc) (up to 6 independent
points). The turning on occurs thought N.A. buttons.
CONTROLS
1-Service staff call
2-Do not disturb
3-Door opening
4-Max 6 lights points
LED SIGNALLINGS
1-General alarm
2-Do not disturb inserted
3-Undelivered message
4-Service staff call on
LINKED FUNCTIONS
1-Turn on barware option for all light
points in the client doorway
e)-Thermostat
Unit installed on a 4U rack frame. It supports every civil series plates. This unit has an independent
microprocessor controlling the room temperature according to the set-point entered from UCG.
The handling firmware avoids the client to make regulations outside the
limits established by the SET-POINTS and locks up the conditioning
system when the window is opened.
The client can operate from the external temperature up to the
maximum limit (winter) or to the minimum (summer) limit set from PC.
When the client is out the Fan-Coil speed cannot be locally regulated
and it is set at the medium speed (Stop includes).
6
TECHNA srl Genova
CONTROLS
1-Client temperature SET
2-F.C.+ speed
3-F.C.- speed
4-Measure precision set and control (only
for service)
DISLAY SIGNALLINGS
1-Fan-Coil speed
2-Fan-Coil on/off state
3-present temperature
4-adjusted temperature
5-Window state
LINKED FUNCTIONS
1-Fan-coil stoppage with window opened
2-Dispay on general PC:
-Room temperature
-Fan-coil state
Operation Description
a)-Terminology
∆T= Temperature difference between adjusted temperature and room temperature
Tm= Maintenance temperature, that is the temperature ain the free room (not assigned) with difference between winter and
summer.
con distinzione tra estate e inverno.
Tc= Confort temperature, that is the room temperature at the first client entrance with difference between winter and summer.
Tp= Temperature adjusted by the client.
Tmc= Maintenance temperature with assigned room and absent client with difference between winter and summer.
Tmax= Maximum temperature in the room with client in (winter).
Tmin= Minimum temperature in the room with the client in (summer).
b)-Fan-Coil automatic working
The Fan-Coil speed, when authorized, is set out as follows (only with client in the room)
V1 (minimum) for ∆T higher then 0°C and less than 2°C
V2 (medium) for ∆T between 2°C and 4°C
V3 (maximum) for ∆T higher than 4°C
c)-Operative cycle with absent client.
-In this phase the thermostat controls are not accessible.
-The room temperature is stabilized on Tm temperature and the Fan- Coil speed is fixed to medium speed (Fan-Coil maximum power
efficiency).
-The Tm temperature is default equal for every day hour, but you can change it in ten times automatically set (generally or room by
room) with the
CRONOTERMOSTAT control on the communication PC.
d)-Operative cycle with client in the room
-At check-in the room temperature will be set to maintenance temperature Tmc. This setting will be cancelled at the check-out and
will be
replaced by the Tm value.
-At Guest’s entrance in the room, the temperature is set at confort temperature Tc and it is maintained until the Guest operates on
the
temperature adjust control.
-The Fan-Coil speed automatic control is on until the Guest operated on it. The control is set on manual mode for all the Guest’s
stay in the room.
-The Guest ca ad just the room temperature up the Tmax and Tmin limit determined by the handling PC. In particular circumstance,
this setting can
be changed room by room: at check-out they will be set at standards levels.
-Through handling PC it is possibile to automatically reset the temperature set by the Guest, after a freely set time (equal for all
rooms), and replace it with the Tc confort temperature.
f)-Flood prevention feeler
It is placet at bathroom floor level inside a proper housing (embedding rack 3u).
Its actuation causes the automatic closing of the water sanitary fixtures solenoid.
g)- Water consumption measuring unit
It consist of a wet analogic meter (not included with the supply) connected to an electronic interface equipped
with a lithium buffer battery (embedding rack 3U).
h)- Power consumption measuring unit
It consist of a wet analogic meter (not included with the supply) connected to an electronic interface equipped
with a lithium buffer battery (embedding rack 3U).
7
TECHNA srl Genova
i)- Messages display
It consists of a dot matrix display (available space 93x70)
and the buttons for the following functions:
-Up/Down text scroll
-Pages scroll
-Pointer shifting
-Messages acceptance (bill,pay-tv,orders,minibar
orders,etc)
-The display is not visibile in the dark and in the standby state it display the present time and date.
This unit is supplied installed an appropriate aluminium
support with policarbonate panel and it is suited for
installation on embedding standard rack. (TICINO
E215/12S)
2-ELECTRICAL CHARACTERISTICS
♦Power supply 24 Vcc
♦Single-point or multi-point network handling with minimal configuration PC:
CPU 500Mhz - Ram 64Mb - HD 1,2 Gb - floppy 3,5" – 3 ports RS232
- 1 parallel port- 1 Mouse PS2 port- 1 Keyboard PS2 port – Modem
♦Operating system : Windows NT4
♦Main network BUS
support : RS485
asynchrounous protocol type CSMA/CD and Polling with univocal addresses
parity:
parity control at 32bit
type-approval:
♦secondary BUS
RINA and LR for safety systems
: ELTBUS max. lenght 70 ml.
♦Peripheral handler
: µP HITACHI
♦Independent BUS RS485 max number: 32.
♦URC or OAC max number on each BUS RS485 without Line-extender: 32
♦Hotel rooms max number on each RCU : 4 (theoretic max 4096 rooms)
♦BUS RS485 max. length without Repeater : ml. 800
8
TECHNA srl Genova
9
TECHNA srl Genova
10
HO-SY
TECHNICAL INFORMATION
ROOM UNIT CONTROL - RCU
Case that may be fastened to DIN EN 50022 standard guides
according to DIN 43880 standard.
Material:self-extinguishing NORYL UL94 V-O
ROOM D
F1=fuse 3A
F2=fuse 1A
F3=fuse 1A
F4=fuse 1A
F5=fuse 1A
ROOM C
24 Vcc/1,5A
JP1-JP2-JP3-JP4=
FEMALE SHIELDED TELEPHONE
CONNECTOR 8/8
JP7-JP8= FEMALE TELEPHONE
CONNECTOR 4/4
ELTBUS ( I²C power BUS
-max length 60 ml.)
8 wires (and shield):
-data
-clock
-direction data
-+15Vcc
-+15Vcc
-GND
-GND
-GND
BUS RS485
JP7=line
Jp10=test
ROOM A
ROOM B
RS485 BUS
-2 shielded twisted pairs
-smt technology
-forced ventilation (only for tropical country)
-Microprocessor (version1) : motorola 68HC705B16
-Clock
: 4MHz
-External Memory: 8K
-I/0
: 256 (64 each ELTBUS )
-Microprocessor (version2) : HITACHI FD64F2134
-Clock
: 4MHz
-External Memory: 16K
-I/0
: 1024 (128 each ELTBUS )
TECHNA srl. via Cassanello 51 - 16155 GENOVA - ITALY
♦tel. +39-0106121129 ♦ fax +39-0106120670 ♦Internet:http://www.techna.it ♦e-mail:[email protected]♦
♦
P.IVA 03756940106 CCIA GENOVA :2060/1999 REA:376935
HO-SY
ROOM I/O
TECHNICAL INFORMATION
RIO
Case that may be fastened to DIN EN 50022 standard guides
according to DIN 43880 standard.
Material:self-extinguishing NORYL UL94 V-O
TO RCU
ROOM DEVICES
TO RPU
ELTBUS (power I²C BUS)
8 wires (and shield):
-data
-clock
-direction data
-+15Vcc
-+15Vcc
-GND
-GND
-GND
RPU CABLE (FLAT
CABLES)IS INCLUDED IN
THE SUPPLY
Local Digital In/Out:
-Fire prevention
-Fire sensor power
-Bathroom Alarm
-Flood Alarm
-Intrusion prevention
-Reset Alarms
-Open Window
-Mini Bar opening
-Safe opening
-Front Door state
-Power presence
-Toilet napkins heater solenoid
state
-Water sanitary fixtures solenoid
state
-Fan-Coil solenoid state
TO PAY TV BOARD
8 WIRES
JP1-JP2-JP3-JP4-JP6=
FEMALE SHIELDED
TELEPHONE CONNECTOR
8/8
JP7=
TERMINAL BLOCK (20
poles)
-smt technology
TECHNA srl. via Cassanello 51 - 16155 GENOVA - ITALY
♦tel. +39-0106121129 ♦ fax +39-0106120670 ♦Internet:http://www.techna.it ♦e-mail:[email protected]♦
♦
P.IVA 03756940106 CCIA GENOVA :2060/1999 REA:376935
HO-SY
TECHNICAL INFORMATION
ROOM POWER UNIT - RPU
Case that may be fastened to DIN EN 50022
standard guides according to DIN 43880
standard.
Material:self-extinguishing NORYL UL94 V-O
Minimum 4M Max:9M
RPU STANDARD
LEDS
(OUTS STATE)
FROM RIO
TERMINAL BLOKS:
JP6=FAN-COIL SPEED(0-1-2-3)
JP3= POWER ON /OFF
JP2=COURTESY LIGHT (3’)
JP5=ELECTRIC LOOK (12/24 Vca)
JP4= FAN-COIL VALVE (12/24 Vca)
-optotriac driver with “zero crossing” (for each out)
-OUT TRIACS (nominal current= 4A)
RPU IS DESIGNED AS CLIENT REQUEST
TECHNA srl. via Cassanello 51 - 16155 GENOVA - ITALY
♦tel. +39-0106121129 ♦ fax +39-0106120670 ♦Internet:http://www.techna.it ♦e-mail:[email protected]♦
♦
P.IVA 03756940106 CCIA GENOVA :2060/1999 REA:376935
HO-SY
TECHNICAL INFORMATION
External Chip-Card reader ERU
Unit installed on a embedded 3U rack frame.
Polycarbonate covering. It supports every civil series
plates.
JP4
JP5
I/0:
-CARD READER
(Disable for Maid when the
Guest is into the room)
-DO NOT DISTURB
(Red Led)
-GENERIC ALARM
(Red Led)
-MINIBAR OPENED
(Orange Led)
-GUEST INTO THE ROOM (Red Led)
-CALL PUSHBUTTON
(Is disable when “Do Not
Disturb” is enable)
-BLINKING LED RED/GREEN
(for chip-card code enable led
go Green àDoor is open)
ELTBUS ( I²C power BUS)
8 wires (and shield):
-data
-clock
-direction data
-+15Vcc
-+15Vcc
-GND
-GND
-GND
JP4-JP5=
FEMALE SHIELDED TELEPHONE
CONNECTOR 8/8
-smt technology
TECHNA srl. via Cassanello 51 - 16155 GENOVA - ITALY
♦tel. +39-0106121129 ♦ fax +39-0106120670 ♦Internet:http://www.techna.it ♦e-mail:[email protected]♦
♦
P.IVA 03756940106 CCIA GENOVA :2060/1999 REA:376935
HO-SY
TECHNICAL INFORMATION
Chip-Card reader within the room
IRU
Unit installed on a embedded 3U rack frame.
Polycarbonate covering. It supports every civil series
plates.
JP4
JP5
I/0:
-CARD READER
-DO NOT DISTURB
-SERVICE PUSH-BUTTON
-ROOM CLEANING STATE
-MESSAGES
(Led and Push-button)
(for Room cleaning state)
(Green/Red Led)
(Orange Led-The Guest
must call the Reception)
-BLINKING LED RED/GREEN
(for chip-card code enable led
go Green à Power go ON))
ELTBUS ( I²C power BUS)
8 wires (and shield):
-data
-clock
-direction data
-+15Vcc
-+15Vcc
-GND
-GND
-GND
JP4-JP5=
FEMALE SHIELDED TELEPHONE
CONNECTOR 8/8
-smt technology
TECHNA srl. via Cassanello 51 - 16155 GENOVA - ITALY
♦tel. +39-0106121129 ♦ fax +39-0106120670 ♦Internet:http://www.techna.it ♦e-mail:[email protected]♦
♦
P.IVA 03756940106 CCIA GENOVA :2060/1999 REA:376935
HO-SY
TECHNICAL INFORMATION
Thermostat
THC
Unit installed on a embedded 4U rack frame.
Polycarbonate covering. It supports every civil series
plates.
ELTBUS ( I²C power BUS)
JP4
JP5
IN/OUT:
-Temperature SET + : pushbutton
-Temperature SET - : pushbutton
-FAN speed (0-1-2-3-): pushbutton
-Temperature sensor
-LCD display 8 digit
8 wires (and shield):
-data
-clock
-direction data
-+15Vcc
-+15Vcc
-GND
-GND
-GND
JP4-JP5=
FEMALE SHIELDED TELEPHONE
CONNECTOR 8/8
Operation Description
a)-Terminology
∆T= Temperature difference between adjusted temperature and room temperature
Tm= Maintenance temperature, that is the temperature ain the free room (not assigned) with difference between winter and
summer.
Tc= Confort temperature, that is the room temperature at the first client entrance with difference between winter and summer.
Tp= Temperature adjusted by the client.
Tmc= Maintenance temperature with assigned room and absent client with difference between winter and summer.
Tmax= Maximum temperature in the room with client in (winter).
Tmin= Minimum temperature in the room with the client in (summer).
b)-Fan-Coil automatic working
The Fan-Coil speed, when authorized, is set out as follows (only with client in the room)
V1 (minimum) for ∆T higher then 0°C and less than 2°C
V2 (medium) for ∆T between 2°C and 4°C
V3 (maximum) for ∆T higher than 4°C
c)-Operative cycle with absent client.
-In this phase the thermostat controls are not accessible.
-The room temperature is stabilized on Tm temperature and the Fan- Coil speed is fixed to medium speed (Fan-Coil maximum power
efficiency).
-The Tm temperature is default equal for every day hour, but you can change it in ten times automatically set (generally or room by
room)
with the CRONOTERMOSTAT control on the communication PC.
d)-Operative cycle with client in the room
-At check-in the room temperature will be set to maintenance temperature Tmc. This setting will be cancelled at the check-out and
will be replaced by the Tm value.
-At Guest’s entrance in the room, the temperature is set at confort temperature Tc and it is maintained until the Guest operates on
the temperature adjust control.
-The Fan-Coil speed automatic control is on until the Guest operated on it. The control is set on manual mode for all the Guest’s stay in the
room.
-The Guest can adjust the room temperature up the Tmax and Tmin limit determined by the handling PC. In particular circumstance, this
setting can be changed room by room: at check-out they will be set at standards levels.
TECHNA reset
srl. via
51 -set
16155
GENOVA
ITALY
-Through handling PC it is possible to automatically
theCassanello
temperature
by the
Guest, -after
a freely set time (equal for all
♦tel. +39-0106121129
♦ fax
+39-0106120670 ♦Internet:http://www.techna.it ♦e-mail:[email protected]♦
♦
rooms), and replace
it with the Tc confort
temperature.
TECHNA srl. Cassanello street,51 - 16155 GENOVA - ITALY
♦tel. +39-0106121129 ♦ fax +39-0106120670 ♦Internet:http://www.techna.it ♦e-mail:[email protected]♦
♦
P.IVA 03756940106 CCIA GENOVA :2060/1999 REA:376935
CONNECTORS AND CABLES FEATURES
MODULAR TELEPHONE PLUG
HO-SY USE:
-RS485BUS: TELEPHONE PLUG 4/4 SHIELDED OR UNSHIELDED
-ELTBUS : TELEPHONE PLUG 8/8 SHIELDED
CABLE TYPE FOR ELT BUS
SCREENED PLUG 8/8
TVK0087
GENERALITA'
SY-HOTEL© impiega la rete di distribuzione televisiva per la diffusione di qualunque tipo di
informazione sia essa analogica che digitale. Il grande vantaggio di SY-HOTEL© e' che puo' utilizzare i
normali impianti televisivi esistenti nelle strutture alberghiere e, in caso di nuove realizzazioni
impiantistiche, la rete televisiva puo' essere realizzata secondo gli standards convenzionali.
Il sistema ,nella sua globalita', puo' attualmente offrire i seguenti servizi:
TV DIFFUSION
Ingegnerizzazione delle reti di distribuzione televisiva
SOUND DIFFUSION
Diffusione sonora nelle camere
Diffusione sonora nelle aree comuni
VIDEO DIFFUSION
Distribuzione di programmi registrati su videocassette o CD per lettori DVD
PAY TV
Estensione del servizio VIDEO DIFFUSION con addebito al Cliente del tempo di visione
dei programmi offerti.
INFO TV ©
Invio di informazioni di carettere generale sullo schermo dell'apparecchio TV di camera.
Le informazioni sono comuni a tutti i Clienti.
Come si nota dalla fig. 1 tutte le applicazioni offerte dal SY-HOTEL confluiscono nella centrale
televisiva.
La completa modularita' del sistema consente ogni ampliamento sia all'interno del singolo
servizio(es. aumento dei canali sound) sia nella espansione dei servizi offerti (es. aggiungere ad un
sistema sound un sistema video o modificare un sistema video in un sistema PAY TV).
Tutte le centrali sono assemblate in armadi modulari metallici secondo lo standard 19",da un
minimo di 18 UNITA' ad un massimo di 42. Grossi complessi sono realizzati affiancando armadi da 32
unita'.Gli armadi sono completi di unita' di ventilazione forzata.
SY-HOTEL funziona con qualunque tipo di centrale televisiva esistente ma e' preferibile che la
stessa sia del tipo moderno ovvero"CANALIZZATO.
TECHNA
SCHEMA SISTEMA SY-HOTEL
TECHNA srl. via Cassanello 51 - 16155 GENOVA - ITALY
♦tel. +39-0106121129 ♦ fax +39-0106120670 ♦Internet:http://www.techna.it ♦e-mail:[email protected]♦
P.IVA 03756940106 CCIA GENOVA :2060/1999 REA:376935
2
TECHNA
TV SYSTEM
Il servizio TV DIFFUSION prevede l'ingegnerizzazione della installazione televisiva.
Questo servizio prevede:
a)- elaborazione del progetto esecutivo
b)-rilievo dei segnali televisivi ricevibili in loco
c)-fornitura di tutti i cavi coassiali
d)-fornitura di tutti i componenti passivi per la realizzazione della rete di
distribuzione(prese,partitori)
e)-fornitura delle antenne televisive normali e del relativo sostegno.
f)-fornitura n.1 parabola tipo OFFSET in vetroresina da ml. 1,20 completa di n. 2
convertitori
g)-fornitura di una centrale televisiva del tipo modulare espandibile,assemblata in armadio
rack 19" e così composta:
-n.10 filtri di canale del tipo attivo dotati di CAG (controllo automatico del guadagno)
-n. 10 ricevitori per emittenti da satellite del tipo professionale con possibilita' di
selezionare ogni parametro video ed audio relativo all'emittente ricevuta.
-n.1 finale UHF (470-860 Mhz) da 1,7 Volt di uscita
-n.1 finale VHF (40-300 Mhz) da 1 Volt di uscita
-n-1 gruppo di alimentazione con ventilazione forzata
-n.1 monitor a colori da 10"
h)-collaudo finale
Engineering impianto Genova-Nervi
TECHNA srl. via Cassanello 51 - 16155 GENOVA - ITALY
♦tel. +39-0106121129 ♦ fax +39-0106120670 ♦Internet:http://www.techna.it ♦e-mail:[email protected]♦
P.IVA 03756940106 CCIA GENOVA :2060/1999 REA:376935
3
TECHNA
SOUND DIFFUSION
Il servizio SOUND DIFFUSION viene realizzato utilizzando come fonti sonore le seguenti apparecchiature:
-ricevitori radio AM/FM
-Lettori Compact Disc o lettori DAT
-Lettori a cassette
-ricevitori radio per emissioni da satellite
Rispetto ai tradizionali sistemi di sonorizzazione (cavo dedicato,filodiffusione ) il nostro sistema offre i seguenti
vantaggi:
1-minori costi di installazione
2-possibilita' di installazione senza opere murarie o con
opere ridotte al minmo
3-distribuzione fino a 16 canali audio
4-possibilita' di inviare messaggi vocali alle singole
camere
La diffusione del suono avviene normalmente in monofonia ma su richiesta puo' essere realizzata in versione
stereofonica. I canali trasmessi sono normalmente cinque; il sistema parte da un minimo di uno ad un massimo di sedici
Come si vede in Fig. 3 ,la centrale di sonorizzazione viene utilizzata per la diffusione del suono sia nelle camere che nelle aree
comuni
La sonorizzazione nella camera avverra' tramite l'apparecchio televisivo o la tradizionale "Testa Letto".
A)- CENTRALE DI SONORIZZAZIONE
La centrale di sonorizzazione viene fornita di serie
composta da :
-n.4 ricevitori radio AM/FM del tipo
a sintonia digitale PLL
-n.1 lettore Compact Disc con
caricatore da 5 dischi con
funzione di autoripetizione
-n.1 pannello di elaborazione audio
per la regolazione automatica
dei livelli di uscita audio
-n.1 titolatrice a colori
-n.1 pannello monitor audio
-n.1 gruppo di generazione per
cinque canali televisivi
La centrale viene fornita di connettori coassiali
per un rapido allacciamento del cavo di
collegamento alla centrale TV ed alla antenna FM
che
viene
fornita
di
corredo
(antenna
omnidirezionale).
Per l'approntamento della centrale occorre
conoscere i canali televisivi occupati nell'esistente
impianto in modo da allocare nello spettro VHF-UHF
i nuovi canali SOUND DIFFUSION.
B)-SONORIZZAZIONE CAMERE
La sonorizzazione della camera puo' avvenire in due modi distinti:
1-sonorizzazione TV
Il normale apparecchio televisivo funge da diffusore audio. Non occorrera' fare altro che sintonizzarlo sul canale SOUND
DIFFUSION : comparira' l'immagine di un orologio ed il programma musicale associato. Il Cliente selezionera' i canali
SOUND con il normale telecomando in dotazione con l'apparecchio televisivo.Tramite la presa SCART dell'apparecchio TV
sara' possibile sonorizzare anche il locale bagno tramite l'utilizzo di un altoparlante amplificato che puo' essere fornito
nelle seguenti versioni:
TECHNA srl. via Cassanello 51 - 16155 GENOVA - ITALY
♦tel. +39-0106121129 ♦ fax +39-0106120670 ♦Internet:http://www.techna.it ♦e-mail:[email protected]♦
P.IVA 03756940106 CCIA GENOVA :2060/1999 REA:376935
4
TECHNA
a)-altoparlante da incasso a soffitto con regolazione del volume fissa o regolabile UP/DOWN
b)-unita' elettronica completa di altoparlante montata su pannello in alluminio completo di scatola da incasso con
regolazione del volume fissa o regolabile UP/DOWN
c)-unita' elettronica ed altoparlante montata su cestello a sei unita' delle serie elettriche civili
(TICINO,AVE,SIEMENS,LEGRAND) con vulume fisso preregolabile internamente
Gli altoparlanti impiegati sono del tipo con membrana anigroscopica.
2-sonorizzazione con Testa Letto
Il diffusore audio e' in questo caso la classica apparecchiatura Testa Letto collegata con la presa televisiva della camera e
con la rete elettrica.
L'altoparlante posto nella Testa Letto puo' essere sostituito con uno esterno collocato a soffitto
(in altri luoghi) per una migliore resa acustica.
La Testa Letto viene fornita di serie cosi' composta:
a)-versione STANDARD
-piastra in alluminio verniciato e serigrafata (e' compreso il logo HOTEL) completa di scatola da incasso.
-tasto ON/OFF
-indicatore luminoso numerico del canale
selezionato (massimo 16)
-tasti aumento e diminuzione volume
-tasto selezione canali
(avanzamento/retrocessione)
-altoparlante
-alimentatore separato completo di scatola
da incasso
b)
versione LIVING
-cestello LIVING 3 posti completo di mascherina in
alluminio verniciato e serigrafato
-indicatore digitale del canale prescelto
-tasti ON/OFF,volume,selezione canale
-alimentatore ed unita' elettroniche su scatola da incasso
separata dal cestello LIVING
B)-SONORIZZAZIONE AREE COMUNI
La centrale SOUND DIFFUSION puo' essere realizzata con l'estensione alla sonorizzazione delle aree comuni ovvero hall,
reception,ristorante,corridoi,ascensori,ecc
La centrale consente la parzializzazione delle aree comuni in sei zone ,o multipli di sei,ovvero ogni zona puo' essere
comandata indipendentemente dalle altre consentendo cosi' l'invio di annunci localizzati o programmi diversi da quelli delle
altre zone.
Ogni altoparlante e' corredato da un amplificatore miniatura da 6 watt montato direttamente sullo stesso.
Il collegamento delle zone con la centrale e’ realizzato con cavo tripolare o con cavo coassiale come per le camere.
Il cavo coassiale e' quello appartenente alla rete di distribuzione televisiva.
Con l'utilizzo di una unita' di amplificazione locale e' possibile rendere autonoma una zona per la diffusione di un
programma musicale,generato localmente, o per rinforzo voce .Pertanto,senza l'impiego di amplificatori portatili o casse
acustiche aggiuntive,e' possibile realizzare una piccola conferenza e sonorizzare un ambiente inserendo semplicemente un
microfono o una fonte musicale direttamente nella unita' di amplificazione.
TECHNA srl. via Cassanello 51 - 16155 GENOVA - ITALY
♦tel. +39-0106121129 ♦ fax +39-0106120670 ♦Internet:http://www.techna.it ♦e-mail:[email protected]♦
P.IVA 03756940106 CCIA GENOVA :2060/1999 REA:376935
5
TECHNA
unita’ rinforzo voce
Quando viene utilizzata la rete televisiva, per ogni zona comune occorre una unita' locale tipo "Testa Letto " living ove
sono presenti i soli comandi volume e selezione programmi.
La zona viene abilitata tramite il cavo coassiale.
In entrambe le versioni,cavo tripolare o cavo coassiale,e' possibile per ogni zona ottenere i seguenti servizi:
-annuncio generale
-annuncio nella singola zona
-selezione programma indipendente per ogni zona
Una base microfonica consente di inviare in generale, o in una zona
L'annuncio viene preceduto dal classico DIN-DON.
particolare,eventuali messaggi o annunci.
VIDEO DIFFUSION
Il servizio VIDEO DIFFUSION viene realizzato utilizzando come fonti i videoregistratori o i lettori di dischi ottici.
I videoregistrtori impiegati sono del tipo a tre o quattro testine DA e dotati di una testina per la pulizia automatica o
manuale delle unita' di lettura nastro.
La centrale VIDEO DIFFUSION viene fornita assemblata in armadio rack 19", predisposto per n.2 fonti video e cosi'
composta:
-n.1 monitor a colori da 14"
-n.1 videoregistratore VHS
-n.1 pannello di controllo e comando contenente:
-timer digitale per la partenza in automatico del videoregistratore
-processore audio per il controllo automatico del volume
-processore video per il controllo del funzionamento del VCR
-n.1 titolatrice a colori
-n.1 gruppo di generazione canale televisivo composto da due modulatori A/V e relativo
alimentatore
La centrale VIDEO DIFFUSION opera nel seguente modo:
Un timer digitale provvede a determinare gli orari di funzionamento del VCR. All'orario prestabilito, il Timer, determina la
partenza del VCR; se dopo qualche secondo non e' presente alcun segnale video,ll processore video provvede ad interrompere il
funzionamento e a generare una nota di allarme. Lo stesso processore provvede ,a termine del programma,a far riavvolgere il
nastro della cassetta e a far ripartire il.VCR se il Timer e' ancora attivo.
Quando il VCR e' inattivo o guasto, il processore video provvede as inserire un duplicato della
immagine creata dalla titolatrice la quale puo' contenere qualunque tipo di informazione sulle 20
pagine a disposizione.
La macchina VIDEO DIFFUSION genera sempre un canale per la titolatrice ed uno per ogni
videoregistratore.
TECHNA srl. via Cassanello 51 - 16155 GENOVA - ITALY
♦tel. +39-0106121129 ♦ fax +39-0106120670 ♦Internet:http://www.techna.it ♦e-mail:[email protected]♦
P.IVA 03756940106 CCIA GENOVA :2060/1999 REA:376935
6
TECHNA
PAY TV
Il nostro sistema PAY-TV si basa sull’utilizzo di una scheda elettronica da installare in ogni camera e su di una centrale per
la generazione dei programmi collegata all’impianto televisivo esistente tramite un cavo coassiale.
La scheda elettronica consente di rilevare quando l’apparecchio televisivo viene sintonizzato su uno dei canali PAY.
Tale rilevazione è utilizzata per l’addebito del servizio all’ospite a seconda delle varie soluzioni impiantistiche adottate
SCHEDA PAY-TV
L’ospite si renderà conto di essere in un programma pay per il fatto che, selezionando con il telecomando tv i vari
programmi ,ne compariranno alcuni con la scritta PAY-TV posizionata in uno degli angoli dello schermo televisivo.
In casi particolari o su richiesta dell’Ospite è possibile oscurare la visione dei programmi PAY nella singola camera.
Sono stati sviluppati due distinti sistemi PAY-TV:
1-gestione automatizzata ON LINE e collegata con il sistema HO-SY:
in questo caso gli addebiti sono effettuati automaticamente dal PC gestionale collegato con tutte
le unità elettroniche di camera
2-gestione automatizzata con MEMORY-KEY:
in questo caso una chiave elettronica memorizza il tempo di utilizzo del servizio :la successiva
lettura al chek-out (tramite PC dedicato)determina l’addebito da effettuare all’Ospite.
La centrale puo’ generare programmi televisivi
provenienti
da
qualunque
fonte
audio-video
(VCR,ricevitori
TV
satellite,
Laser-disc,emittenti
televisive terrestri).
In tutte le versioni è presente una titolatrice a colori con
la quale è possibile dare informazioni di qualunque natura
ai propri Ospiti.
Questa titolatrice è inviata su un proprio canale
televisivo, indipendente dai programmi PAY, e
normalmente viene memorizzata (sull’apparecchio TV )
immediatamente prima di questi ultimi in modo da
avvisare l’Ospite come utilizzare gli stessi programmi .
La centrale consente la gestione completamente
automatica dell’invio dei filmati
e la gestione e’
realizzata tramite il PC fornito in dotazione: nella
versione con videoregistratori occorrera’ solamente
inserire le videocassette.
Avremo quindi riproduzione continua dello stesso
film,riproduzione singola ad orari definiti e riproduzione
multipla.
La centralina di controllo VCR provvede ad inserire il
codice PAY e la scritta PAY-TV sul filmato in corso: è
possibile disattivare tale scritta e codice se si intende
mandare in onda un programma senza addebito.
Ogni qualvolta il filmato termina la centralina di
controllo VCR provvede a far riavvolgere il nastro e a
posizionare il VCR in attesa della successiva partenza
stabilita.
In caso di blocco del nastro in riproduzione ,la
centralina VCR provvede a sostituire l’immagine con
quella generata dalla titolatrice in dotazione e a produrre
un segnale acustico di allarme. La scritta PAY-TV ed il
codice PAY sono automaticamente rimossi.
La scritta PAY-TV è posizionabile a piacere su
qualunque posizione dello schermo ed è possibile
aggiungere anche il titolo del programma in corso.
TECHNA srl. via Cassanello 51 - 16155 GENOVA - ITALY
♦tel. +39-0106121129 ♦ fax +39-0106120670 ♦Internet:http://www.techna.it ♦e-mail:[email protected]♦
P.IVA 03756940106 CCIA GENOVA :2060/1999 REA:376935
7
TECHNA
Le funzioni delle singole apparecchiature costituenti la centrale sono le seguenti :
1-MONITOR TV COLOR : consente la visione del programmi in corso tramite
il selettore CHANNEL del monitor audio.
2-MONITOR AUDIO: consente la visione ,sul monitor video, e l’ascolto dei
programmi in corso tramite il seletttore CHANNEL.
3-VCR CONTROLLER : provvede a controllare le funzioni del VCR (PLAYSTOP,REW) ,a verificare la presenza del filmato a generare la nota di
allarme in caso di guasti e ad immettere in linea, in assenza di
programma o in caso di guasto ,l’immagine generata dalla titolatrice.
Dalla stessa unita’ è possibile effettuare le seguenti operazioni
manuali:
a)-visione sul monitor video del filmato senza mandarlo in onda
b)-selezionare il timer digitale o la partenza manuale
c)-resettare il tempo di attesa tra uno stop e il successivo START.
Questo tempo fisso di circa 5 minuti serve a far riavvolgere
qualunque tipo di v ideocassetta.
d)-selezionare la visione PAY o la visione FREE
e)-genera il codice PAY da inviare unitamente al programma sul cavo
coassiale della rete televisiva,per la identificazione da parte delle
unità elettroniche di camera
4-VCR1 - VCR 2 : fonti video (standard registratori a 4 testine DA)
5-CONTROLLER: interfaccia digitale con il PC gestionale
6-TITOLATRICE: titolatrice a colori
7-MODULATORI A/V : modulatori PLL programmabili su tutto lo spettro
VHF/UHF
8-FILTRI DI USCITA ED ALIMENTAZIONE: filtri RF per i modulatori ed
alimentatore 24 Vcc per tutta la sezione RF.
INFO TV
INFO TV e' un servizio specifico per
l'invio
di
qualunque
tipo
di
informazione al Cliente in camera
direttamente
sullo
schermo
televisivo.
Si basa essenzialmente su due
sistemi:
1-possibilita' di accedere,da parte
del Cliente, direttamente al tipo di
informazione che interessa.
2-consultazione di TUTTE le
informazioni inviate senza possibilita'
di scelta alcuna.
Il primo sistema viene realizzato
mediante il display installato nella
camera e collegato con il sistema HOSY,mentre il secondo utilizza una
comune titolatrice a colori (fornita in
diversi modelli a seconda delle
prestazioni).
TECHNA srl. via Cassanello 51 - 16155 GENOVA - ITALY
♦tel. +39-0106121129 ♦ fax +39-0106120670 ♦Internet:http://www.techna.it ♦e-mail:[email protected]♦
P.IVA 03756940106 CCIA GENOVA :2060/1999 REA:376935
8
SYSTEM DESCRIPTION
A car parking automation system has an exact aim: making the entrance and exit
operations as most quick and efficient as possible.
Some system options besides ensuring a quick and effective way of payment, they also
help the client in the parking space search.
This system is based on rechargeable chip-cards use, which can include other
information (issue date, serial number, uses amount, etc.) and they can be used for
parallel enterprises (parking bar, underground/bus tickets machine, automatic car
washing, etc.).
The system base elements are the following:
Access terminal: Clients with chip-card entrance and also clients without chip-card
entrance, who will receive an admission ticket with bar-code containing the entry
information.
Optionally, the client can receive a ticket containing all the temporal entry data.
Payment unit/Recharging: with this system the client can recharge his chip-card and
also pay the ticket/bar code received at the entrance if he is out of chip-card. In this
case he can choose to pay only the parking used, the bar code ticket is returned to him
and this will enable him to the exit bar, or he can buy a deduction card using it for the
exit (with the parking amount deduction) and for other future parkings.
Exit terminal: Bar opening with the chip-card insertion used at the entry (with
deduction of the parking amount) and also with the bar-code ticket insertion used at the
entry and for the payment.
This system can operate also with payment of the period really used: only the client
with chip-card can pay the parking used minutes, not the whole hours, making in this
way a more satisfied user (and an incentive to use the card, that is a client capital in
the car- parkingkeeper hands).
In this case the deducted time wil be considered in minutes from the entry moment
(card inserted in the entry terminal) until the exit moment (card inserted in the exit
terminal) eliminating in this way the idle period between the payment end the exit.
TECHNA
OPTIONS
- Closed-circuit monitoring system: the car parking operation and its parameters can
be monitored and radio-controlled by telephone from a remote control station.
- Occupation: it is possible to determine exactly the free parking spaces: coils
inserted in the floor of each car parking space indicate exactly how many and which
spaces are free.
- Parking space search: with this option the system identifies the free space
closer to the entry and drives the client to the assigned space through light guides on
the ceiling or on the floor.
- Availability: In a car parking integrated system, remote numbered boardings,
connected by telephone, direct the potential clients to the closer free car parking.
- Free car parking remote indication: A special service can inform with a vocal
message on the mobile phone of the client who made the request, of the car parking
space availability within the city or in the single car parking.
- Regular clients booking: a regular registered client can book a parking
space: the system will book the space in any way, considering it as a taken
space (eventually in a particular area, protected by a bar). The client will
obviously pay for the space even if he doesnt’ take it for the necessary time.
This operation can be made by
- GSM mobile phone with SMS, indicating the foreseen entry and stay time.
The system will book a parking space with turn-over stoppage with a foreseen
algorithm to be defined). If the client doesn’t arrive within the foreseen stay
time, the car parking system will free the space (making it available for other
clients) charging only the booked stay time: if the space is effectively taken,
the system will charge it as from the booking time until the releasing time.
TECHNA srl. via Cassanello 51 - 16155 GENOVA - ITALY
♦tel. +39-0106121129 ♦ fax +39-0106120670 ♦Internet:http://www.techna.it ♦e-mail:[email protected]♦
P.IVA 03756940106 CCIA GENOVA :2060/1999 REA:376935
2