Socomec Sicon UPS
Transcript
Socomec Sicon UPS
Bienvenue INCONTRO TECNICO LA CONTINUITA’ DELL’ALIMENTAZIONE ELETTRICA: CORRELAZIONI TRA GRUPPI ELETTROGENI E GRUPPI STATICI DI CONTINUITA’UPS Mercoledì 11 Maggio 2005 Presso: Castel San Pietro - BO Golf club “LE FONTI” Viale Terme, 1800 Bienvenue SOCOMEC SICON UPS PROFILO AZIENDALE Un gruppo, dueBienvenue divisioni Siti produttiviBienvenue Interruttori industriali sede 1 personale sede 2 personale 12 000 m2 342 13 000 m2 334 UPS Benfeld FRA (sede 3) personale Villaverla ITA personale Processi produttivi certificati 13 000 m2 401 14 000 m2 238 Due divisioni Bienvenue UPS Interruttori industriali Sistemi UPS Monofase da 300 a 120 kVA Trifase da 4,5 a 800 kVA Stazioni di Energia (SE) Raddrizzatori e SE in c.c. da 7,5 a 6000 A Inverter e SE in c.a. da 1,5 a 18 kVA Sezionamento BT Interruttori e sezionatori (con o senza fusibili) Commutatori di potenza Controllo – Gestione & protezione elettrica Strumenti multimisura Conteggio e gestione d’energia Controllo e protezione delle reti Sistemi di trasferimento del carico MTC. Gamma monofase da 50 a 270 A e trifase da 30 a 4 800 A IT-Switch da 16 a 32 A Compensatori di armoniche Gamma da 15 a 90 kVA Sistemi di distribuzione di potenza Armadi vuoti o attrezzati Centraline di rifasamento Accessori di montaggio - cablaggio Crescita costante Bienvenue 192 189 190 169 138 108 Fatturato (MILIONI Euro) 1998 1999 2000 2001 2002 2003 Una presenza mondiale Bienvenue 1 700 persone ripartite in: - 15 filiali nel mondo - 7 siti industriali (3 in Francia, 2 in Italia, 1 in Tunisia, 1 in India) Filiali Distributori Una ricerca e sviluppo all’avanguardia Bienvenue , - . /,#/ 0 ! + * *! "# ( () % ! &'! "# $ ! $! ) %/" Premio Frost &Bienvenue Sullivan Il riconoscimento Frost & Sullivan 2003 per “l’eccellenza nell’attenzione al cliente nel mercato degli UPS” è assegnato al Gruppo Socomec. Bienvenue DefinizioniBienvenue !" # $ # # % $ &'(' Struttura di un UPS Bienvenue Ingresso Rete Alimentazione Raddrizzatore e/o Caricabatterie Batterie Inverter Ingresso Rete Soccorso Il neutro è passante By-Pass statico By-Pass manuale UPS tipo “VFI-SS-111” secondo EN62040-3 Tre tipologie : IEC 62040-3 Bienvenue LIVELLO PARALLELO DI PROTEZIONE RIDONDANTE / COSTO - STS “off-line” “line-interactive” “on-line” Parallelo: Ridondante o di potenza Bienvenue PARALLELO DI RIDONDANZA Il guasto UPS carico su UPS PARALLELO DI POTENZA Guasto UPS carico in rete Parallelo: modulare o centralizzato Bienvenue MODULARE: Sistemi ridondanti 1+1 (i by-pass sopportano al massimo la corrente del singolo UPS) CENTRALIZZATO: Oltre sistemi ridondanti 1+1 Paralelli di potenza (il by-pass sopprta la corrente dell’intero impianto) (alta capactà di corto circuito) Bienvenue DIMENSIONAMENTO UPS Bienvenue • Occorre conoscere la somma vettoriale delle potenze dei carichi (STOT e fdpTOT); • La distorsione armonica di tensione dell’UPS è funzione del fattore di cresta del carico (C.F.UPS>C.F.CARICHI @ THDv); • Il sovraccarico UPS da batteria deve “reggere” il sovraccarico tipico del carico (in tempo e in potenza); • L’autonomia da batteria deve essere calcolata per la potenza ATTIVA del carico. CARICHI Bienvenue PARTICOLARI • In ambiente informatico: FAX, STAMPANTI, FOTOCOPATRICI • In ambiente industriale: MOTORI • Nell’emergenza: LAMAPDE • ... CARICHI CON CORRENTE PULSANTE UNIDIREZIONALE •… CARICHI DISTOCENTI MONOFASI COLLEGATI A STELLA MOTORI (spunto all’avvio) Bienvenue dY: 425 A Y: -226 A Durata spunto 100ms Corrente di spunto 9xIn 21 > > 1) Ch 1: 2) Ch 2: T T 2 1> > 1) Ch 1: 2) Ch 2: 200 Volt 100 ms 100 A 100 ms Corrente sinusoidale 200 Volt 10 ms 100 A 10 ms In figura 1 è riportato l’oscillogramma della tensione stellata (in blu) e della corrente sulla rispettiva fase (in rosso) durante la fase di avviamento di un motore asincrono trifase a rotore avvolto da 7kW; Il motore è utlizzato come pompa per il sollevamento di acqua. La corrente di avviamento è sfasata in ritardo rispetto alla tensione,ha forma sinusoidale ed ha un valore nei primi cicli molto elevato MOTORI Bienvenue Sovradimesionamento IUPS(NOM)> (9/ ) IMOT(NOM) per DIGYS EVO 3/3 da 10kVA a 30kVA Durata sovraccarico 10 minuti (t<30°C) 1 minuti (t<30°C) 2 minuti (t>30°C) 10 sec (t>30°C) 1.25 1.5 Nel caso gli avviamenti siano frequenti e contemporanei tra più motori =1; MOTORI Bienvenue Soluzioni: •Sovradimensionare UPS (tutti i motori in marcia + lo spunto del numero massimo di motori che possono accendersi contemporaneamente) • Usare a monte del motore un avviatore con rampa di avvio e bassa corrente di spunto •Inibire l’avvio del motore se rete non presente ( segnalare ai sistemi uP o PLC di non avviare il motore) MOTORI Bienvenue Ritorni di energia • L’UPS non riesce a recuperare “grandi” energie sulle batterie • Non esistono soluzioni applicabili sull’UPS • Usare resistenze di frenatura sull’azionamento o allungare le rampe di decelerazione compatibilmente con l’applicazione LAMPADEBienvenue A SCARICA T T T 1> 2> 1> 1) Ch 1: 2) Ch 2: 200 mVolt 10 ms 100 Volt 10 ms Zoom (phi= 90°) 1) Ch 1: 200 mVolt 200 ms Corrente di spunto=1.8 Inom per 600ms LAMPADEBienvenue A SCARICA Corrente di spunto=1.8 Inom per 600ms • 600ms è considerato dall’UPS come un sovraccarico • Considerare la “sovraccaricabilità” dell’ UPS ed il fattore di contemporaneità • Un UPS con una sovraccarico tipico dovrebbe essere sovradimensionamento del +30% - +40% Bienvenue Armoniche di Bienvenue corrente: problemi • DISTORSIONE DELLA TENSIONE • SURRISCALDAMENTO DEI TRASFORMATORI • SURRISCALDAMENTO DEI CAVI • DIMINUZIONE DEL FATTORE DI POTENZA • INTERVENTO INOPPORTUNO DELLE PROTEZIONI RADDRIZZATORE A 6 IMPULSI Bienvenue • Three phase SCR rectifier (6 pulse) High input THD > 30 % Power factor 0.8 to 0.85 High efficiency Harmonic spectrum 40% 30% 28 % 20% 10% Input current 8% 7% 5% 4,7 % H7 H11 H17 H19 0% H5 RADDRIZZATORE A 12 IMPULSI Bienvenue • Dodecaphase SCR rectifier (12 pulse) Input THD 10 to 12 % Power transformer required Reduced floor space = cost Power factor 0.85 Harmonic spectrum 30% 20% 10% 9% 6% 3,4 % 2,4 % Input current 0% H11 H13 H23 H25 CORREZIONE “DELTA” Bienvenue Line interactive technology (eg Delta conversion) Alimentation primaire THD from 2% to >12% load & supply conditions dependent. Power factor dependent on load conditions & supply conditions. No frequency correction. Limited protection against over-voltage. Can be affected by load high short circuit current. Charge FILTRI PASSIVI Bienvenue Three phase rectifier + Passive LC filter Typical THD 6 to 10 %, only tuned at nominal load. Filtering effectiveness is load dependent, drops with load rate. More space requirements. Resonance & over-capacitive risks. Filter overloading risk, by utility harmonics. H5 filter FILTRI ATTIVI Bienvenue SCR Three phase rectifier + Active Filter Input THD 3% to 5%, Additional Hardware = lower system reliability, Lower efficiency, High cost, Filter shall be rated at ≈ 1/3 of rectifier nominal current Higher extra losses eg. 30 Amps active filter ≈ 1,5 to 2 kW losses RADDRIZZATORE IGBT Bienvenue • PWM IGBT three phase rectifier bridge U I U I I CONFRONTO RADDRIZZATORI Bienvenue % THDi 30 Raddrizzatore Boost 25 20 15 6 p. + filtro LC 12 impulsi 10 5 0 Raddriz. IGBT 0,3 Pn 0,5 Pn Pn UPS IN PARALLELO Bienvenue Phase shifted rectifiers results depending on nb of shifted units distortion increases when unit(s) stop(s) poor Power Factor costly solution extra floor space requirements (transformer) UPS UPS UPS Bienvenue BATTERIE Bienvenue • Per il calcolo dell’autonomia occorre conoscere la potenza ATTIVA del carico. • La potenza apparente o peggio quella “informatica” non permettono il calcolo corretto dell’autonomia. • L’autonomia dipende dalla tensione di fine scarica (typ=1.7V/el) e dalla temperatura (typ=20°C). •Il tempo di ricarica dipende dalla corrente di ricarica min 5-6% C10 (20 ore ca.), max 20% C10 (5 ore ca.). •Attenzione alla “profondità” della scarica VTA ATTESA Bienvenue Classificazione EUROBAT •3-5 anni •6-9 anni •10-12 anni •>12 anni BATTERIE (calcolo autonomia) Bienvenue Stringhe in parallelo: 2 Batterie in serie (ogni stringa): 34 Tipo batteria: SWL750 Potenza del carico: 12000W Rendimento UPS a 12000W: 0,906 Temp. Amb.: 20 °C (lambda= 0,005) Potenza richiesta carico Prichiesta(1 batt) = ---------------------------------------------------- = 193,923W (32.3 W/el) (Num batterie X Num Stringhe X Rendimento) Autonomia (interpolazione tabella batteria a 1,70 V/el) = 64' VENTILAZIONE BATTERIE Bienvenue Batterie stazionarie: Sicurezza (EN50272-2) Formula per calcolo ventilazione locali batterie: scopo mantenere la concentrazione di idrogeno <4% Q: flusso d’aria minimo per mantenere una corretta ventilazione Q (m3/h) = 0,05 x n x Ig x C x 10-³ n: numero di elementi (celle) Ig: corrente di ricarica [mA/Ah] C: capacità (Pb:1.8V /20°C) Ventilazione naturale (raccomandata) o forzata A (cm2) = 28 x Q (2 aperture ingresso e uscita per varia supposta 0.1 m3/s) Bienvenue SOVRACORRENTI - Ingresso Bienvenue INGRESSI SEPARATI INGRESSO SINGOLO SOVRACORRENTI - Ingresso Bienvenue La taglia viene consigliata dal costruttore •Preferire UPS a bassa distorsione armonica in ingresso Casi patricolari: • UPS 3/1 La corrente di by-pass è il triplo della corrente del raddrizzatore: dimensionare la protezione sulla corrente di by-pass • UPS 3/3 e carichi Non Lineari monofasi La corrente sul neutro (150Hz) può raggiungere 2.2 volte la corrente di fase: dimensionare la protezione sulla corrente del neutro SOVRACORRENTI - Uscita Bienvenue Due correnti di corto circuito: • con rete presente (15-20In) • in assenza rete • Da BATTERIA: 2-3In • Da GRUPPO EL: ZGE>3xZtrasf Usare il criterio del caso peggiore (cortocircuito da inverter) Non interviene MAI: • E’ in serie con l’inverter • E’ in serie con la protezione di by-pass SELETTIVITA ’ Bienvenue I2tMCB-2 I2tSCR =11000 A2s I2tMCB-2 A2s I2tMCB-3 I2tUPS = 22.05 A2s I2tMCB-3 A2s Icc-inv= 21A Selettività a valle tra una sorgente a potenza limitata e distribuione di interruttori magnetotermici. Selettività da by-pass e da batteria Icc-line= 6000A PROTEZIONE DIFFERENZIALE Bienvenue • I filtri EMI di ingresso dell’UPS impongono di sovradiemsionare il differenziale di ingresso. • Deve essere garantita la selettività tra differenziale di ingresso (“S”) e differenziali della distribuzione in uscita (“g”) come in un normale impianto di distribuzione (“S” ritardato di almeno 0.6s o IdS >3Idg, “g” non ritardato) [CEI 64-8/5, sistema TT]. • Nel sistema IT (o in isola) può intervenire intempestivamente. •Il differenziale di ingresso deve essere sensibile alle correnti a valore medio diverso da zero CONTATTI INDIRETTI Bienvenue- Ingresso id id id Il neutro del raddrizzatore e del by-pass sono accomunati all’interno dell’UPS CONTATTI INDIRETTI Bienvenue- Ingresso Σ I≠ 0 •Utilizzare un unico differenziale •Disaccoppiare i neutri CONTATTI INDIRETTI Bienvenue- Ingresso id Per UPS in PARALLELO I neutri delle due UPS sono accomunati CONTATTIBienvenue INDIRETTI - Uscita Nel caso di interruttori differenziali sia a monte che a valle dell’UPS bisogna prestare attenzione alla corretta selettività id id id id id id Funzionamento dell’UPS in isola Bienvenue Funzionamento in isola Bienvenue FUNZIONAMENTO IN ISOLA con controllo dell’isolamento FUNZIONAMENTO IN ISOLA con trasformatore di isolamento FUNZIONAMENTO IN ISOLA con connessione neutro-terra Neutro USARE PROTEZIONI TRIPOLARI (SE POSSIBILE) [TN-C] RITORNI DI ENERGIA Bienvenue Direttiva ENEL DK 5600 • Nel caso in cui il cliente sia dotato di gruppi statici di continuità per servizi non interrompibili di un certo rilievo, e quindi non di tipo mobile monofase <= 6 kW, si deve evitare che tali apparecchiature possano fornire, anche transitoriamente, energia alla rete ENEL. La separazione di tali apparecchiature dalla rete deve essere garantita, oltre che dal dispositivo statico anche da un dispositivo capace di assicurare una separazione metallica rispondente alle norme CEI 64-8, CEI EN 500911/1 e CEI EN 60947-4-1. La richiusura automatica o manuale di tale sezionamento deve essere possibile solo dopo la ripresa del servizio sulla rete ENEL. RITORNI DI ENERGIA Bienvenue uP RITORNI DI TENSIONE Bienvenue uP ESD Bienvenue Bienvenue ! ! ! INTEGRAZIONE CON « GE » Bienvenue INTEGRAZIONE CON « GE » Bienvenue •Il raddrizzatore dell’UPS assorbe una corrente distorta: in funzione del valore di distorsione occorre sovradimensionare il gruppo elettrogeno a monte : Pge=kxPUPS Dove k può variare da 1.2 a 2 e oltre. •Per grosse potenze (>100kVA) il GE può soffrire la presa di carico a gradino